Loading...
HomeMy WebLinkAbout2025-755-E-AMS-Sasser Companies-SHSC ASI 001 Reno Revised 01/24 1 [Departmental Use Only] TITLE SHSC Health Reno FY 2025-2026 NORTH CAROLINA CONSTRUCTION AGREEMENT UNDER $250,000.00 ORANGE COUNTY THIS CONSTRUCTION AGREEMENT (hereinafter called “Agreement”), made as of the 5th day of December, 2025, by and between Sasser Companies, LLC, (hereinafter called the “Contractor”), and Orange County, a political subdivision of the State of North Carolina, (hereinafter called the “County,” “Orange County,” or “Owner”). W I T N E S S E T H: That the Contractor and the Owner, for the consideration herein named, agree as follows: 1. CONTRACT DOCUMENTS; PRIORITY The Contract Documents consist of this Agreement, the Request for Proposals, Proposal, Construction Drawings, and Written Specifications. The Contract Documents form the Contract. In the event of any inconsistency between or among the Contract Documents the Contract Documents shall be interpreted in the following order of priority: a. This Agreement. b. Designer Approved Bulletins and Field Orders. c. Request for Proposals and addenda thereto. d. Proposal. 2. SCOPE OF WORK The Contractor shall furnish and deliver all of the materials, and perform all of the work required by this Agreement within the time period stipulated in a written Notice-to-Proceed to be executed by the Contractor and Owner and in accordance with the following enumerated documents, which are made a part hereof as if fully contained herein: a. Construction Drawings prepared by Smith Sinnett Architecture (Sheet AIA G710-2017 Architect's Supplemental Instructions Package, ASI Number 001 dated 10/13/2025) b. Written specifications prepared by the project engineer. c. Sasser Companies, LLC proposal dated November 20, 2025 which fully describes the work to be performed. Such work will hereafter be called the “Work”. d. Related documents listed under Section 1 above. 3. TERM AND SCHEDULING a. The Contractor agrees to commence work pursuant to the written Notice to Proceed. Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Revised 01/24 2 b. The Contractor agrees to complete substantially all Work by January 31, 2026. c. Time is of the essence with respect to all dates specified in the Contract Documents as Completion Dates. d. The Contractor shall perform the Work in the time, manner, and form required by the Contract Documents and as stipulated in a written Notice-to-Proceed to be executed by the Contractor and Owner. e. It is expressly understood that the Owner will employ other contractors to perform work as a part of the Project whose work will be performed simultaneously and sequentially with the performance of the Work by the Contractor. It shall be necessary for the Contractor to coordinate its activities with such other contractors, particularly with respect to access to work areas, storage of materials and other common facilities. f. Should the Owner determine that the Contractor is behind schedule Owner may require, at no additional cost to the Owner, the Contractor to expedite and accelerate its efforts, including providing additional resources and working overtime, as necessary, to perform the Work in accordance with the approved project schedule. 4. STANDARD OF CARE a. The Contractor shall exercise reasonable care and diligence in performing the Work in accordance with the highest generally accepted standards of this type of Contractor practice throughout the United States and in accordance with applicable federal, state and local laws and regulations applicable to the performance of these services. Contractor is solely responsible for the professional quality, accuracy and timely completion and submission of all work. b. The Contractor shall not load or permit any part of the Work to be loaded with a weight that will endanger its safety, intended performance or configuration. c. Contractor shall be responsible for all errors or omissions caused by its employees, agents, contractors, or assigns in the performance of the Agreement. Contractor shall correct any and all errors, omissions, discrepancies, ambiguities, mistakes or conflicts at no additional cost to the Owner. d. Contractor is an independent contractor of Owner. Any and all employees of the Contractor engaged by the Contractor in the performance of any work or services required of the Contractor under this Agreement, shall be considered employees or agents of the Contractor only and not of the Owner, and any and all claims that may or might arise under any workers compensation or other law or contract on behalf of said employees while so engaged shall be the sole obligation and responsibility of the Contractor. e. If activities related to the performance of this Agreement require specific licenses, certifications, or related credentials Contractor represents that it or its employees, agents and subcontractors engaged in such activities possess such licenses, certifications, or credentials and that such licenses certifications, or credentials are current, active, and not in a state of suspension or revocation. Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Revised 01/24 3 f. The Contractor is responsible for all physical damage to owned or rented machinery, tools, equipment, forms, and other items owned, rented or used by the Contractor and Subcontractor(s) in the performance of the Work including all of Owner’s property in Contractor’s care, custody, or control, and all such property while it is in transit. g. The Contractor is solely responsible for obtaining all permits necessary to complete the Work in compliance with all local, state, and federal laws. 5. PAYMENT & TAXES a. The Owner hereby agrees to pay to the Contractor for the faithful performance of this Agreement and the Contractor hereby agrees to perform all of the Work for a sum not-to- exceed Twenty-Eight Thousand, Nine Hundred Dollars ($28,900.00). Not later than the fifth (5th) day of each calendar month the Contractor shall submit to the Owner’s Representative, generally the architect if an architect is retained on the Work, a Request for Payment for work done during the previous calendar month. i. The Request for Payment shall be in form of a standardized invoice or AIA Document G702-703 appropriately addressed to Owner’s Representative at PO Box 8181, Hillsborough, NC 27278 and shall show substantially the value of work done during the previous calendar month. ii. The amount due for payment shall be ninety-five percent (95%) of the value of work completed since the last Request for Payment and this amount shall be paid by the Owner on or before the last business day of the month. Owner shall retain five percent (5%). 1. Upon Owner’s Representative’s certification that ninety percent (90%) of the Work has been satisfactorily completed retainage may be discontinued. Retainage may be discontinued, at Owner’s Discretion, so long as work continues to be completed satisfactorily and on schedule. iii. Final payment shall not be due to the Contractor until thirty (30) days after one hundred percent (100%) of the Work, including punch list work, has been satisfactorily (as determined by the County) completed and an appropriate affidavit as required in Section 7(c) below has been received by Owner. b. Should Owner reasonably determine that Contractor has failed to perform the Work related to a Request for Payment, Owner, at its discretion may provide the Contractor ten (10) days to cure the breach. Owner may withhold the accompanying payment without penalty until such time as Contractor cures the breach. i. Should Contractor or its representatives fail to cure the breach within ten (10) days, or fail to reasonably agree to such modified schedule, Owner may immediately terminate this Agreement in writing, without penalty or incurring further obligation to Contractor. ii. This section shall not be interpreted to limit the definition of breach to the failure to perform the Work related to a Request for Payment. c. The Contractor has included in the Contract Price and shall pay all taxes assessed by any authority on the Work or the labor and materials used therein. It shall be the Contractor's responsibility to furnish the Owner documentary evidence showing the materials used and sales and use tax paid by the Contractor and each of its subcontractors. Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Revised 01/24 4 6. INSURANCE AND BONDS a. Minimum requirements – Contractor shall obtain, at its sole expense, Commercial General Liability Insurance, Automobile Insurance, Workers’ Compensation Insurance, and any additional insurance as may be required by Owner’s Risk Manager as such insurance requirements are described in the Orange County Risk Transfer Policy and Orange County Minimum Insurance Coverage Requirements (each document is incorporated herein by reference and may be viewed at http://www.orangecountync.gov/departments/purchasing_division/contracts.php). If Owner’s Risk Manager determines additional insurance coverage is required such additional insurance shall be designated here NA (if no additional insurance required mark N/A as being not applicable). Contractor shall not commence construction work until such insurance is in effect and certification thereof has been received by the Owner's Risk Manager. b. Performance Bonds – Contractor shall furnish bonds covering the faithful performance of the Contract and payment of all obligations arising under any of the Contract Documents or related in any way to the Work. Contractor shall immediately furnish a copy of such bonds to any requesting person who appears to be a potential beneficiary of bonds covering payment obligations arising under any of the Contract Documents. This subsection 6(b) applies only to Contracts of fifty thousand dollars ($50,000.00) or more where the total cost for the project is three hundred thousand dollars ($300,000.00) or more. 7. INDEMNITY a. To the extent authorized by North Carolina law the Contractor shall indemnify, without limitation, and hold harmless to the maximum extent permitted by law the Owner and its agents and employees from and against any and all claims, damages, losses and expenses, including attorney's fees, arising out of or resulting from the performance or nonperformance of the Work, provided that any such claim, damages, loss or expense (A) is attributable to bodily injury, sickness, disease or death or injury to, or destruction of, property, including the loss of use resulting therefrom; and (B) is caused in whole or in part by any breach of any provision of the Agreement or by any negligent or wrongful act or omission of the Contractor, any Subcontractor, or supplier of the Contractor, anyone directly or indirectly employed by any of them or anyone for whose acts any of them may be liable. The indemnification obligation under this paragraph shall not be limited in any way by any limitation of the amount or type of damages, compensation or benefits payable by or for the Contractor or any subcontractor under workers' compensation acts, disability benefits acts or other employee benefit acts. It is the intent of this section that the Contractor shall indemnify the County to the maximum extent allowed by law. b. The Contractor shall indemnify and hold harmless Owner from any lien of whatever type through the purchase of appropriate bonds and insurance as designated in Section 6 above. In the event any such lien is filed against Owner’s property Contractor shall, through such bonds and insurance or at Contractors expense, defend Owner against all such claims of lien. Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Revised 01/24 5 c. Upon completion of the Work the Contractor shall execute an affidavit stating there are no unpaid debts for any work that has been done or materials that have been furnished to the project prior to and as of the date of substantial completion and further stating that Contractor shall indemnify, save and protect Owner and Owner’s lender, if any, harmless from and against any and all claims, liabilities, losses, damages, causes of action, and expenses (including court costs and reasonable attorney’s fees related thereto) arising out of, in connection with, or resulting from any such debts and liens. Such indemnification shall be in a form and substance acceptable to Owner. d. By executing this Agreement Contractor agrees to abide by and be bound by the indemnification provisions herein. 8. DISPUTE RESOLUTION AND GOVERNING LAW a. Any dispute with respect to any provision of, or the performance or non-performance of, this Agreement shall be subject to the Dispute Resolution Rules and Procedures for Orange County Design, Building Construction, Renovation, and Repair Projects. The policy is incorporated herein by reference and may be viewed at http://www.orangecountync.gov/departments/purchasing_division/contracts.php). b. The laws of the State of North Carolina shall apply to the interpretation and enforcement of this Agreement. Any and all suits or actions to enforce, interpret or seek damages with respect to any provision of, or the performance or nonperformance of, this Agreement or the Contract shall be brought in the General Court of Justice of North Carolina sitting in Orange County, North Carolina and it is agreed by the parties that no other court shall have jurisdiction or venue with respect to such suits or actions. c. Notice of any claim by Owner or Contractor must be initiated by written notice to the other Party within thirty (30) days of the occurrence of the event giving rise to the claim or within thirty (30) days of the discovery of the event or condition giving rise to the claim, whichever is later. i. Should any claim be made, regardless of whether such claim is made by Owner or Contractor, Contractor shall continue to faithfully and diligently perform the Work in such a manner as to meet all scheduled timelines. Any failure to faithfully and diligently perform the Work may be deemed, by the Owner, a breach of the Contract. ii. If a claim is made such claim shall be made to the initial decision maker, if applicable, who may request more supporting data, reject the claim in whole or in part, approve the claim in whole or in part or advise the parties the claim is unable to be resolved. iii. If a claim is made by the Owner the Owner may, but is not obligated to, notify the surety. 9. NON–APPROPRIATION a. Contractor acknowledges that Owner is a governmental entity, and the validity of this Agreement is based upon the availability of public funding under the authority of its statutory mandate. Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Revised 01/24 6 b. In the event that public funds are unavailable or not appropriated for the performance of Owner’s obligations under this Agreement, then this Agreement shall automatically expire without penalty to Owner immediately upon written notice to Contractor of the unavailability or non-appropriation of public funds. It is expressly agreed that Owner shall not activate this non-appropriation provision for its convenience or to circumvent the requirements of this Agreement. c. In the event of a change in the Owner’s statutory authority, mandate or mandated functions, by state or federal legislative or regulatory action, which adversely affects Owner’s authority to continue its obligations under this Agreement, then this Agreement shall automatically terminate without penalty to Owner upon written notice to Contractor of such limitation or change in Owner’s legal authority. 10. NOTICES Any notice required by this Agreement shall be in writing and delivered by certified or registered mail, return receipt requested to the following: Owner: Contractor: Orange County Sasser Companies, LLC Attn: A. Barnes Attn: Angelo Bartis P.O. Box 8181 PO Box 10 Hillsborough, NC 27278 Whitsett, NC 27377 11. MISCELLANEOUS a. Duties and Obligations imposed by the Contract Documents shall be in addition to any Duties and Obligations imposed by state, federal or local law, rules, regulations and ordinances. b. No act or failure to act by the Owner or Contractor shall constitute a waiver of any right or duty granted them under the Contract Documents, nor shall any act or failure to act constitute any approval except as specifically agreed in writing. c. The Work shall be tested and inspected as required by the Contract Documents and as required by law. Unless prohibited by law the costs of all such tests and inspections related to state and federal codes such as ADA, Administrative, Electrical, Plumbing, Mechanical and Building Codes shall be borne by the Contractor. The costs for material and structural testing shall be conducted by an independent third party at the expense of the Owner. Delays related to any of the aforementioned tests and inspections shall not be grounds for delaying the completion of the work. If any such tests and inspections reveal deficiencies in the Work such that the Work does not comply with terms or requirements of the Contract Documents and the requirements of any code or law the Contractor is solely responsible for the cost of bringing such deficiencies into compliance with the terms of the Contract Documents and any code or law. d. Should the Architect, if an architect is retained for the project involving the Work, or Owner reject any portion of the Work for failing to comply with the Contract Documents Contractor shall immediately, at Contractor’s expense, correct the Work. Any such rejection may be made before or after substantial completion. If applicable, any additional Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Revised 01/24 7 expense borne by the Architect under this section shall be paid at Contractor’s expense. e. The Contractor shall not assign any portion of this Agreement nor subcontract the Work in its entirety without the prior written consent of the Owner. f. By executing this Agreement Contractor affirms that Contractor and any subcontractors of Contractor are and shall remain in compliance with Article 2 of Chapter 64 of the North Carolina General Statutes. g. By executing this Agreement Contractor certifies that Contractor has not been identified, and has not utilized the services of any agent or subcontractor identified, on the list created by the State Treasurer pursuant to G.S. 147-86.58. h. By executing this Agreement Contractor certifies that Contractor has not been identified, and has not utilized the services of any agent or subcontractor identified, on the list created by the State Treasurer pursuant to G.S. 147-86.81. i. The County has designated (Angel Barnes) to act as the County's representative with respect to the Work and shall have the authority to render decisions within guidelines established by the County Manager or the County Board of Commissioners and shall be available during working hours as often as may be reasonably required to render decisions and to furnish information. j. Contractor shall at all times remain in compliance with all applicable local, state, and federal laws, rules, and regulations including but not limited to all state and federal non- discrimination laws, policies, rules, and regulations and the Orange County Non- Discrimination Policy and Orange County Living Wage Policy (each Orange County policy is incorporated herein by reference and may be viewed at http://www.orangecountync.gov/departments/purchasing_division/contracts.php). Any violation of the Orange County Non-Discrimination Policy is a breach of this Agreement and County may immediately terminate this Agreement without further obligation on the part of the County. This paragraph is not intended to limit and does not limit the definition of breach to discrimination. k. This Agreement together with any amendments or modifications may be executed electronically. All electronic signatures affixed hereto evidence the consent of the Parties to utilize electronic signatures and intent of the Parties to comply with Article 11A and Article 40 of North Carolina General Statute Chapter 66. l. In the event of a breach by Contractor Owner has sole authority to determine the reasonableness of Contractor’s actions to remedy such breach or complete the performance of its obligations. m. Upon request of the Owner, the Contractor shall submit to County all relevant documentation, including but not limited to, job cost records, to support its claims for final compensation and if such request is made final compensation shall not be due until all relevant documentation is received, reviewed, and approved by Owner. Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Revised 01/24 8 n. There are no third-party beneficiaries of this Agreement and nothing in this Agreement, express or implied, is intended to confer on any person other than the parties hereto (and their respective successors, heirs and permitted assigns), any rights, remedies, or obligations. 12. CONSEQUENTIAL AND LIQUIDATED DAMAGES a. Owner and Contractor mutually waive any claim against each other for consequential damages. Consequential Damages include: i. Damages incurred by Owner for loss of use, income, financing, or business. ii. Damages incurred by Contractor for office expenses, including personnel, loss of financing, profit, income, business, damage to reputation, or any other non-direct damages. b. Liquidated damages shall be in accord with the Contract Documents. If the Contract Documents do not otherwise address liquidated damages, such damages shall be in the amount of five hundred dollars ($500.00) per day. 13. TERMINATION OR SUSPENSION a. The Owner may, without cause, order the Contractor to terminate, suspend, delay or interrupt the Work in whole or in part for such period of time as the Owner may determine. i. If Owner issues a written order to delay, suspend, or interrupt the Work, and such order is not due to or as a result of any fault on the part of the Contractor or any subcontractor, the Contractor may recover a per diem amount of five hundred dollars ($500.00) per day with a not-to-exceed limit of ten thousand dollars ($10,000.00). ii. In the event of termination by the Owner under this Agre ement, the Contractor shall be entitled to receive its reasonable and documented direct costs incurred prior to the date Owner mails the notice of termination, including the cost of materials purchased for the Work, but only if such purchases cannot be canceled, or materials returned, or which material cannot reasonably be used by the Contractor on other work, and the cost of closing down the work in a safe and efficient manner. iii. If Owner elects to suspend or terminate the contract pursuant to subparagraphs 13.a.i. or 13 a.ii. the sole remedy available to the Contractor are those listed in said subparagraphs and Contractor is not entitled to any right to further claims for any amount owed or disputed or for payment of damages alleged to have been sustained as a result of Owner’s order to delay, suspend, or interrupt the Work. b. The Owner may, with cause, order the Contractor to suspend, delay or interrupt the Work in whole or in part for such period of time as the cause remains. i. If Owner issues a written order to delay, suspend, or interrupt the Work, and such order is due to or as a result of any fault on the part of th e Contractor or any subcontractor, the Owner may reduce payment at a per diem amount of five Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Revised 01/24 9 hundred dollars ($500.00) per day for the full duration of the delay, suspension, or interruption. c. Contractor may terminate the Contract if, at the Owner’s written direction, the Work is stopped for thirty (30) consecutive days through no act or fault of the Contractor, their agents or employees, or a subcontractor or their agents or employees or any other person performing work pursuant to the Contract Documents. Contractor may terminate the Contract if a Court or other Public authority having jurisdiction enters a lawful order that requires all work to be stopped and such stoppage lasts for thirty (30) consecutive days. d. Either party may terminate this Agreement upon notice to the other party that obligations pursuant to this Agreement are made impossible due to declarations of emergency by Orange County or by North Carolina due to events directly impacting Orange County. Both parties shall remain responsible for all payment and performance due up to the receipt of such notice, but shall have no further obligation or responsibility beyond that date provided the terminating party has taken all reasonable steps to complete the performance of its obligations. 14. ENTIRE AGREEMENT All of the documents listed, referenced or described in this Agreement, the written Notice-to- Proceed, together with Modifications made or issued in accordance herewith are the Contract Documents, and the work, labor, materials and completed construction required by the Contract Documents and all parts thereof is the Work. The Contract Documents constitute the entire agreement b etween Owner and Contractor. This Agreement may be amended only by written instrument signed by both parties. Modifications may be evidenced by facsimile signatures. If any provision of the Agreement shall be declared invalid or unenforceable, the remainder of the Agreement shall continue in full force and effect. IN WITNESS WHEREOF, the Parties hereto have executed this Agreement as of the day and date first above written wholly or in a number of counterparts each of which shall, without proof or accounting for other counterparts, be deemed an original contract. ORANGE COUNTY CONTRACTOR ____________________________________ ________________________________________ Signature Signature County Manager ________________________________________ Printed Name and Title Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A 11/25/2025 Project ExecutiveAngelo Bartis 12/23/2025 Revised 01/24 10 ORANGE COUNTY—INTERNAL USE ONLY ______________________________________________________________________________ Finance Information Vendor Name: Sasser Companies, LLC Vendor Contact Person: Angelo Bartis (abartis@sasser247.com) Phone: 336.833.6333 Address: PO Box 10 City Whitsett State: NC Zip: 27377 Department: AMS Amount: 28,900.00 Purpose: SHSC ASI 001 Reno Budget Code(s): 61370035-892000-30012 Vendor # 65006 Vendor Status with NCSOS: Current - Active Vendor is a BOCC consultant: Yes No Contract Details Contract Type: New Amendment (Original Contract: ) (Most Recent Amendment ) Effective Date 12/5/2025 End Date 1/31/2026 Notice Date (Notice Purpose ) Award Approved by Board (Agenda Date: ); Made or Administered by AMS Signature Authority - BOCC Express Delegation (Agenda Date: ) - Policy 9.4: Under $5,000; Service Under $90,000; Construction Under $250,000 - Budget Policy Section XV (Capital Improvement Project: 30012) Bidding Informal Bidding ($30k-$90k); Formal RFP ($90k+); Other (<$30k); Exception(# ) Department Affirmation This agreement is approved as to technical form and content and I as Department Director affirmatively state work on this project has not been initiated prior to execution of the agreement ; OR This agreement is approved as to technical form and content . Services related to this agreement have already begun or been completed. Description of the nature of the emergency condition that was addressed: Department Director’s Signature ________________________________________ Date: ________ Information Technologies This agreement has been reviewed and is approved as to information technology content an d specifications: Office of the Chief Information Officer___________________________________ Date: ________ Inapplicable because no hardware/software purchases or related services Risk Management This agreement is approved for sufficiency of insurance standards, specifications, and requirements: Office of the Risk Management Officer___________________________________ Date: _________ Financial Services This instrument has been pre-audited in the manner required by the Local Government Budget and Fiscal Control Act: Office of the Chief Financial Officer ____________________________________ Date: _________ Legal Services This agreement is approved as to legal form and sufficiency: Office of the County Attorney __________________________________________Date: ________ Clerk to the Board All Docusign contracts must be copied to the Clerk upon completion: occlerkdocs@orangecountync.gov The following signature block is for hard copies only and is not required for Docusign contracts: Received for record retention: Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A 11/27/2025 12/1/2025 12/1/2025 12/22/2025 Revised 01/24 11 Office of the Clerk to the Board __________________________________________Date:_________ Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Phone: (336) 449-1144 PO Box 10, Whitsett, NC 27377 Fax: (336) 449-1151 www.SASSER247.com PROPOSAL 11/20/25 Orange County Southern Building 2501 Homestead Rd Chapel Hill Re: Office Upfit Angel Barnes, Sasser Companies will provide labor and materials for the Southern Building office upfit per our on-site visit with Jim Breakey of Orange County. We will remove a wall in space(420 A-B) to make one big room. The walls will be repaired and painted, new flooring, rework the ceiling and electrical! Room (431) will get a new wall to split the one big room into (2) smaller rooms. We will rework the ceiling, build a new wall and paint, new flooring and electrical! Let me know if you have any questions. Cost: $ 28,900.00 (Note: security wiring and fire alarm wiring will be Owner) Many Thanks, Angie Bartis Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A 10-13-2025 Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett / 2024008 Hillsborough, NC Orange County Asset Management Services ASI 01 1 ASI 01 ISSUE DATE: September 10th, 2025 PROJECT: Southern Human Services Health Clinic Chapel Hill, NC OWNER: Orange County 131 Margaret Lane Hillsborough, NC 27278 ARCHITECT: Smith Sinnett Architecture, P.A. 4600 Lake Boone Trail, Suite 205 Raleigh, North Carolina 27607 This ASI shall modify the contract for the above-referenced project. All General, Supplementary and Special Conditions, etc., as originally specified or as modified below shall apply to these items. General 1. N/A Drawings 1. Replaced, CVR in lieu of G0-01: MEP consultant added to design professionals, Index of Drawings updated to include new sheets, updated NC Existing Building Code Decision Diagram. 2. Revised G0-02: Code Summary revised for Level II Alteration requirements. 3. Added G1-01: Life Safety Plan added to drawing set per Level II Alteration requirements. 4. Added A1-02: Enlarged Demo and New Work Floor Plans, and Enlarged Demo and New Work Reflected Ceiling Plans for Interview 420A, Interview 420B, and Medical Records 431. 5. Revised A7-02: LVT replacement scope expanded to include Medical Records 431, Clerical 433, and Finance 434, per owner request. Flooring installation direction changed in Fin. Int. 432. Flooring installation symbol added for clarity in exam room wing. Flooring legend updated for clarity. 4. Added M0-00, M1-01, M1-02: Mechanical Demo and New Work plans, details, and schedules added to address additional scope. 5. Added E0-00, E1-01, E1-02: Electrical Demo and New Work plans, details, and schedules added to address additional scope. Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett / 2024008 Hillsborough, NC Orange County Asset Management Services ASI 01 2 Specifications 1. Added: 092900 Gypsum Board 2. Added: 095123 Acoustical Tile Ceilings 3. Added: Division 23 Heating, Ventilating, and Air Conditioning 4. Added: Division 26 Electrical End of ASI 01 Attached: Drawings: CVR G0-02 G1-01 A1-02 A7-02 M0-00 M1-01 M1-02 E0-00 E1-01 E1-02 Specifications: 092900 Gypsum Board 095123 Acoustical Tile Ceilings 230512 Electrical Work 230529 Hangers and Supports for HVAC Piping and Equipment 230553 Identification for HVAC Piping and Equipment 230593 Testing, Adjusting, and Balancing for HVAC 230713 Duct Insulation 233100 HVAC Ducts and Casings 233300 Air Duct Accessories 233700 Air Outlets and Inlets 260505 Electrical Demolition 260519 Power Conductors and Cables 260529 Hangers and Supports for Electrical Systems 260533.13 Conduit for Electrical Systems 260533.16 Boxes and Cabinets 260553 Identification for Electrical Systems 260923 Lighting Control Devices 262726 Wiring Devices 265100 Interior and Exterior Lighting Other: N/A Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A EXAM406EXAM407EXAM408NURSEPRACTITIONER410EXAM413EXAM414STER415MEDICALSUPPLIES416PHARM.417CORRIDOR109INT.420DINT.420CINT.420AT.B. / INT.420FMED. REC. A431AFIN. INT.432OFFICE426OFFICE425OFFICE424OFFICE111OFFICE110LIBRARY108OFFICE427OFFICE428TOILET418TOILET419CLINIC MGR.401BLOOD DRAWING402LAB411LAB TECH.409HEALTH ED.OFFICE404HIV403AREA NOT IN SCOPEAREA NOT IN SCOPEAREA NOT IN SCOPEHEALTH ED.SUPPORT412INT.420EPATIENT ED.405LOBBY400SUPPORT430CORRIDOR133T1T1T1T1T1T1T1T1T1T1T1T1T1T1T1T1CLERICAL433T1T1T1T1T1T1MED. REC. B431BFINANCE434333333333333333RESILIENT TRANSITION STRIP -JOHNSONITE SLT-XX-C, LOCATE UNDER DOOR, TYPEXISTING CARPETLVT-1 ; TERMINATE UNDER TRANSITIONCONC FLOOR SLAB11FLOORING LEGENDREMOVE EXISTING CARPET AND RUBBER BASE. REPLACE WITH NEW LVT -1 AND RB-1. HATCH INDICATES FLOORING INSTALLATION DIRECTION.NEW CHAIR RAIL (CR-1), 29-35" A.F.F.INDICATES OPEN KNEE SPACE, CONTINUE FLOORING UNDER COUNTERTOPLVT-1MANUFACTURER: TBDPRODUCT: TBDCOLOR: TO BE SELECTED BY OWNERCONTACT: TBDRB-1MANUFACTURER: JOHNSONITEPRODUCT: TRAD. DURACOVE 4"COLOR: GREY 48CONTACT: STEPHANIE HARRIS, 910-710-3900STEPHANIE.HARRIS@TARKETT.COMALL PRODUCTS DESCRIPED BELOW ARE BASIS OF DESIGN. REFER TO PROJECT SPECIFICATIONS FOR ACCEPTABLE ALTERNATES.CR-1MANUFACTURER: INPROPRODUCT: 1600 SERIES WALL GUARDCOLOR: CASTLE 0256LVT TO CPT TRANSITION STRIP, REFER TO T1REMOVE EXISTING VINYL FLOORING AND RUBBER BASE. REPLACE WITH NEW LVT -1 AND RB-1, REFER TO SYMBOL FOR FLOORING INSTALLATION DIRECTION./2A7-02FLOORING INSTALLATION DIRECTION33This drawing and the design shown is the property of Smith Sinnett Architecture, P.A. the reproduction or use of this property without the written consent of the Architect is prohibited. Any infringement of the ownership rights will be subject to legal action. All copies of this drawing must be returned to the Architect at the completion of the contract.Smith Sinnett Architecture, P.A. 2025THIS DRAWING IS FORMATTED TO BE PRINTED ON A 30" X 42" SHEETDRAWN BY:CHECKED BY:DESCRIPTIONDATEIDT 919 781 85824600 Lake Boone TrailSuite 205Raleigh, NC 27607info@smithsinnett.comITB 367-OC5452C:\Users\drew\Documents\2020072 SHSC-Health Department_dwilgus@smithsinnett.com.rvt10/13/2025 12:02:14 PMA7-02ORANGE COUNTY HELATH DEPARTMENT IMPROVEMENTSFLOORING PLANAND DETAILSSOUTHERN HUMAN SERVICES HEALTH CLINIC202400809 OCT 20252501 Homestead Rd, Chapel Hill, NC. 27516CONSTRUCTION DOCUMENTNBDWREGISTEREDARCHITECTURALCORPORATIONNORTHCAROLINAARCHITECTU,PARALEIGH50172CERT. NO.RESINETTNSMIHT3/16" = 1'-0"A7-021FLOORING PLAN3" = 1'-0"A7-022T1- LVT TO CPT THRESHOLD DETAIL01'8'16'4'1 04/18/2025 ADDENDUM 13 10/9/2025 ASI 01Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A SYMBOL DESCRIPTION SUPPLY DUCT RETURN DUCT BALANCING DAMPER OUTSIDE AIR INTAKE DUCT SMOKE DETECTOR MOTORIZED DAMPER, PARALLEL BLADE FOR SHUT-OFF, OPPOSED BLADE FOR MODULATING, 24V ACTUATOR. R R C C T# TEMPERATURE SENSOR. LABEL INDICATES UNIT CONTROLLED. REFRIGERANT PIPING CONDENSATE PIPING _ x _ _ x _ _ x _ MD MANUAL BALANCING DAMPER, OPPOSED BLADE, DOUBLE FLANGED. PROVIDE FACTORY SLEEVE, AND MANUAL HAND QUADRANT WITH INSULATION EXTENSION. AIR PERFORMANCE TESTED IN ACCORDANCE WITH AMCA. LEAKAGE CLASS 1, 8 CFM/SF AT 4 in w.g. VD FIRE DAMPER. 1.5 HOUR FOR 1 HR AND 2HR CONSTRUCTION, 3 HOUR FOR 3 HR CONSTRUCTION. TYPE B WITH BLADES OUT OF AIR STREAM. UL 555 LISTED. PROVIDE FACTORY SLEEVE. PROVIDE MULTI-SECTION ASSEMBLY AS REQUIRED FOR DUCT DIMENSIONS. PROVIDE THIN-LINE MODEL OR OUT OF WALL MODEL WHERE APPROPRIATE. FD SD POINT OF DISCONNECTION / DEMOLITION POINT OF CONNECTION PROVIDE TAPERED TAKE-OFF WITH ADJUSTABLE VOLUME DAMPER, AIR DISTRIBUTING GRID, OR RADIUS TAKE-OFF WITH STRAIGHTENING VANES AT TAKE-OFF. NOTE: TAPERED TAKE-OFF BUTTERFLY DAMPER WITH LOCKING QUADRANT TAPERED TAKE-OFF WITH ADJUSTABLE VOLUME CONTROL DAMPER CEILING GRID SUPPLY AIR DIFFUSER FLEXIBLE RUNOUT (5 LINEAR FT. MAX., UNLESS OTHERWISE NOTED.) BRANCH DUCT EXTERNALLY INSULATE ROUND SHEET METAL RUNOUT RECTANGULAR DUCT SUPPLY AND INSTALL AN INSULATED METAL ELBOW WHERE DUCT CONNECTS TO DIFFUSER. REINFORCEMENT MAY BE USED FOR ATTACHMENT IF IT QUALIFIES FOR BOTH DUTIES. DO NOT EXCEED LOAD RATINGS FOR METHOD USED. FROM SMACNA DUCT STANDARDS TRAPEZE HANGERS 1. 2. NOTES: ROUND DUCT SUPPORTSTRAP HANGERS HANGERS FOR STACKED DUCT 3" 12" 1" MINIMUM MAXIMUM SPACING ROD NUTS ANGLES ALTERNATE LOCATION HANGER STRAP SLING - AVOID DISRUPTION OF INSULATION LOAD RATED FASTENERS (TYPICAL) BAND OF SAME SIZE AS HANGER STRAP HANGER RODS OR STRAPS BAND SCREWS (TYPICAL) HANGER STRAP ROD STRAP OR ANGLE SIZE BOLT(S) FOR LOAD CAULK FLANGE & SECURE TO WALL & DUCT FLANGE SHALL EXTEND TO THE ENTIRE PERIMETER OF THE DUCT (PLAN VIEW)This drawing and the design shown is the property of Smith Sinnett Architecture, P.A. the reproduction or use of this property without the written consent of the Architect is prohibited. Any infringement of the ownership rights will be subject to legal action. All copies of this drawing must be returned to the Architect at the completion of the contract.Smith Sinnett Architecture, P.A. 2025THIS DRAWING IS FORMATTED TO BE PRINTED ON A 30" X 42" SHEETDRAWN BY: CHECKED BY: DESCRIPTIONDATEID T 919 781 8582 4600 Lake Boone Trail Suite 205 Raleigh, NC 27607 info@smithsinnett.com ITB 367-OC5452C:\Users\dlowry\OneDrive - Progressive Design Collaborative, Ltd\Documents\25027 Orange County Southern Health_MEP_R24_dlowryPDCBIM.rvt10/3/2025 8:59:58 AMM0.00ORANGE COUNTY HELATH DEPARTMENT IMPROVEMENTSLEAD SHEETSOUTHERN HUMAN SERVICES HEALTH CLINIC2024008 03 OCT 20252501 Homestead Rd, Chapel Hill, NC. 27516CONSTRUCTION DOCUMENTJAV JTB 1. THE CONTRACT DOCUMENTS ARE COMPLIMENTARY AND WHAT IS REQUIRED BY ONE SHALL BE AS BINDING AS IF REQUIRED BY ALL. IN THE CASE OF A CONFLICT, DISAGREEMENT, OR AMBIGUITY, PROVIDE THE BETTER QUALITY. IN THE CASE OF A CONFLICT, DISAGREEMENT, OR AMBIGUITY, PROVIDE THE GREATER QUANTITY OF WORK. 2. COORDINATE ALL WORK WITH THAT OF THE OTHER DISCIPLINES PRIOR TO THE INSTALLATION OF ANY PIPING, DUCTWORK, OR EQUIPMENT. 3. PERFORM A COMPLETE REVIEW OF THE CONTRACT DOCUMENTS PRIOR TO INSTALLATION OF THE MECHANICAL SYSTEMS AND REVIEW ANY CONFLICTS WITH THE ENGINEER. 4. DURING THE CONSTRUCTION PROCESS, PROTECT ALL EQUIPMENT, DEVICES, DUCTWORK, PIPING, AND APPURTENANCES FROM DIRT, DEBRIS, AND RAIN. STORE IN A COVERED LOCATION OFF OF THE FLOOR AND ABOVE STANDING WATER. ITEMS FOUND LYING IN STANDING WATER ON THE JOB SITE WILL NOT BE ACCEPTED FOR INSTALLATION. 5. ENSURE THAT ITEMS TO BE FURNISHED OR PROVIDED WILL FIT IN THE SPACE AVAILABLE. MAKE NECESSARY FIELD MEASUREMENTS TO ASCERTAIN SPACE REQUIREMENTS, INCLUDING THOSE FOR CONNECTIONS, AND PROVIDE SUCH SIZES AND SHAPES OF EQUIPMENT THAT ARE THE TRUE INTENT AND MEANING OF THE CONTRACT DOCUMENTS. PROVIDE THE ENGINEER WITH SCALED COORDINATION DRAWINGS OF ALL MECHANICAL SPACES AND ABOVE CEILING INSTALLATIONS. 6. LOCATE ALL EQUIPMENT TO PROVIDE MAXIMUM SPACE FOR MAINTENANCE AND SERVICE. 7. PROVIDE ALL ELECTRICAL AND CONTROL CONNECTIONS TO THE EQUIPMENT PROVIDED. REFER TO THE ELECTRICAL DRAWINGS FOR LOCATIONS OF JUNCTION BOXES, DISCONNECTS, CIRCUIT BREAKERS (PANELBOARDS). TYPE, SIZE, AND NUMBER OF CONDUCTORS AND CONDUITS TO EQUIPMENT SHALL BE EQUIVALENT TO THE CONDUCTORS AND CONDUITS PROVIDED BY DIVISION 26. IN CASE OF MECHANICAL EQUIPMENT CONNECTION TO A CIRCUIT BREAKER, THE NUMBER AND SIZE OF THE CONDUCTORS AND CONDUITS SHALL CONFORM TO THE LATEST NATIONAL ELECTRICAL CODE REGULATIONS. ALL MOTOR STARTERS, SWITCHES, CONTROL DEVICES, ETC., PROVIDED BY DIVISION 23 SHALL BE RECESSED IN THE WALLS, EXCEPT WHEN THESE ITEMS ARE LOCATED IN MECHANICAL SPACES. PROVIDE A NAMEPLATE FOR ALL EQUIPMENT, SWITCHES, CONTROL DEVICES, ETC. REFER TO THE GENERAL PROVISIONS SECTION OF THE DIVISION 23 SPECIFICATIONS. 8. PROVIDE ALL SUPPORT DEVICES NECESSARY FOR THE WORK. COORDINATE ALL LOCATIONS WITH OTHER DISCIPLINES PRIOR TO INSTALLATION. 9. REFER TO THE ARCHITECTURAL DRAWINGS FOR FLOOR PLAN DIMENSIONS AND ELEVATIONS. DO NOT SCALE THESE DRAWINGS. 10. PROVIDE ALL PENETRATIONS PERTAINING TO THE WORK THROUGH THE ROOF, WALLS, AND FLOORS. PROVIDE THE WATERPROOFING AROUND THE OPENINGS. 11. FIRE SEAL ALL FLOOR AND FIRE WALL PIPE AND CONDUIT PENETRATIONS WITH A UL APPROVED METHOD. 12. PROVIDE ALL CUTTING AND PATCHING OF FLOORS AND WALLS FOR THE WORK UNLESS OTHERWISE INDICATED. 13. ALL WALL AND FLOOR PENETRATIONS SHALL BE SEALED. SEAL ALL RATED FLOOR AND WALL PENETRATIONS WITH A UL APPROVED METHOD. FOR NON-RATE WALLS AND FLOORS, THE ANNULAR SPACE SHALL BE PACKED WITH MINERAL WOOL, OR ANOTHER SUITABLE NON-COMBUSTIBLE MATERIAL, AND CAULKED AIR RIGHT. 14. DUCT DIMENSIONS SHOWN ARE INSIDE CLEAR UNLESS OTHERWISE INDICATED. 15. PROVIDE FLEXIBLE DUCT CONNECTORS AT SUPPLY, RETURN, AND EXHAUST DUCTWORK CONNECTIONS TO ALL AIR HANDLING UNITS AND FANS. 16. PROVIDE SHEET METAL COLLAR AT ALL LOCATIONS WHERE DUCTS PENETRATE WALLS. COLLARS SHALL BE OF A GAGE EQUIVALENT TO THE DUCTWORK. 17. ALL ACCESS DOORS IN THE DUCTWORK SHALL BE LOCATED TO EASILY ACCESS FIRE DAMPERS. COORDINATE CEILING ACCESS PANEL LOCATIONS WITH ALL OTHER DISCIPLINES. ALL ACCESS DOORS IN DUCTWORK FOR FIRE DAMPERS, DUCT- MOUNTED COILS, CONTROL DAMPERS, HUMIDIFIERS, DUCT SMOKE DETECTORS, AND OTHER DEVICES SHALL CONFORM TO THE FOLLOWING SCHEDULE: DUCT WIDTH ACCESS DOOR SIZE UP TO 17" WIDE 16"x12" (OR AS LARGE AS POSSIBLE) 18" TO 22" 16"x16" 22" AND LARGER 18"x18" 18. PROVIDE BALANCING DAMPERS IN ALL LOW PRESSURE DUCTS FOR SYSTEM BALANCING. 19. PROVIDE ADJUSTABLE CONTROL DEFLECTION DEVICES AT ALL BRANCH DUCT TAKE-OFFS. 20. ALL ELBOWS IN DUCTWORK SHALL BE 1-1/2W RADIUS ELBOWS, UNLESS INDICATED OTHERWISE. WHERE RECTANGULAR ELBOWS ARE INDICATED, INSTALL DOUBLE WIDTH TURNING VANES. 21. ALL DUCT LAYOUT AND LOCATIONS INDICATED ARE DIAGRAMMATIC. VISIT THE SITE, BECOME FAMILIAR WITH THE EXISTING CONDITIONS, AND COORDINATE THE DUCT LAYOUT WITH ALL DISCIPLINES PRIOR TO INSTALLATION. 22. SUPPORT ALL DUCTWORK, PIPING, EQUIPMENT, AND APPURTENANCES FROM THE BUILDING STRUCTURE AND NOT THE ROOF DECK. 23. INSULATE ALL SUPPLY DIFFUSERS AND DUCTED RETURN DIFFUSERS WITH 2" - 1# R.6 DUCT WRAP. CUT DIFFUSERS SO THERE IS A FOLDED 2" LAP ON ALL FOUR SIDES. TAPE WITH FSK TAPE WHERE INSULATED FLEX MEETS DUCT INSULATION, AND SO THERE ARE NO RAW EDGES OF FIBERGLASS. 24. DO NOT INSTALL DUCTWORK OVER ANY ELECTRICAL PANEL OR SWITCHGEAR. 25. ZIP TIES WILL NOT BE PERMITTED FOR USE AS CABLE SUPPORTS. WHERE NOT REQUIRED TO BE INSTALLED IN RACEWAY BY THE SPECIFICATION, PROVIDE J-HOOK SUPPORTS AND BRIDLE RINGS. CABLE SHALL BE INDEPENDENTLY SUPPORTED AND SHALL NOT BE SUPPORTED OF THE WORK OF OTHER TRADES. SYMBOL LEGENDABBREVIATIONSGENERAL NOTES MECHANICAL SUMMARY MECHANICAL SYSTEMS, SERVICE SYSTEMS AND EQUIPMENT CODE 2018 NC ENERGY CODE: PRESCRIPTIVE ___X___ PERFORMANCE _______ ASHRAE 90.1-2013: PRESCRIPTIVE _______ PERFORMANCE _______ ADDITIONAL PRESCRIPTIVE COMPLIANCE: _____ 506.2.1 MORE EFFICIENT MECHANICAL EQUIPMENT __X__ 506.2.2 REDUCED LIGHTING POWER DENSITY _____ 506.2.3 ENERGY RECOVERY VENTILATION SYSTEMS _____ 506.2.4 HIGHER EFFICIENCY SERVICE WATER HEATING _____ 506.2.5 ON-SITE SUPPLY OF RENEWABLE ENERGY _____ 506.2.6 AUTOMATIC DAYLIGHTING CONTROLS THERMAL ZONE: 3A WINTER DRY BULB: 19.6 DEGREES F SUMMER DRY BULB: 95.0 DEGREES F SUMMER WET BULB: 75.5 DEGREES F SUMMER HR/MCDB: 134.2 / 82.7 DEGREES F INTERIOR DESIGN CONDITIONS WINTER DRY BULB: 70 DEGREES F SUMMER DRY BULB: 75 DEGREES F RELATIVE HUMIDITY: 55 % BUILDING HEATING LOAD: 3,261 MBH BUILDING COOLING LOAD: 299.1 TONS MECHANICAL SPACING CONDITIONING SYSTEM UNITARY DESCRIPTION OF UNIT: REFER TO SCHEDULE ON DRAWINGS HEATING EFFICIENCY: REFER TO SCHEDULE ON DRAWINGS COOLING EFFICIENCY: REFER TO SCHEDULE ON DRAWINGS SIZE CATEGORY OF UNIT: REFER TO SCHEDULE ON DRAWINGS BOILER: TOTAL BOILER OUTPUT. IF OVERSIZED, STATE REASON. 3,790 MBH CHILLER: TOTAL CHILLER CAPACITY. IF OVERSIZED, STATE REASON. 335.2 TONS REFER TO EQUIPMENT SCHEDULES FOR UNIT EFFICIENCIES. DESIGNER STATEMENT: TO THE BEST OF MY KNOWLEDGE AND BELIEF, THE DESIGN OF THIS BUILDING COMPLIES WITH THE MECHANICAL SYSTEMS, SERVICE SYSTEMS AND EQUIPMENT REQUIREMENTS OF THE NORTH CAROLINA STATE ENERGY CODE MECHANICAL ABBREVIATIONS ACCU AIR COOLED CONDENSING UNIT ACU AIR CONDITIONING UNIT AD ACCESS DOOR AF AIR FILTER AFF ABOVE FINISHED FLOOR AHU AIR HANDLING UNIT ALUM ALUMINUM AMP AMPERE AP ACCESS PANEL ARCH ARCHITECTURAL AVG AVERAGE CC AIR COLLED CONDENSER B BOILER B.I. BLACK IRON BB BASEBOARD RADIATION BDD BACKDRAFT DAMPER BHP BRAKE HORSEPOWER BO BLANK OFF BTU BRITISH THERMAL UNIT BTUH BRITISH THERMAL UNITS PER HOUR CA COMPRESSED AIR CAP CAPACITY CAU COMPRESSED AIR CC COOLING COIL CFM CUBIC FEET PER MINUTE CH CHILLER CI CAST IRON CL CENTER LINE CO CARBON MONOXIDE CO CLEAN OUT CONC CONCRETE CT COOLI NG TOWER CU CONDENSING UNIT CUH CABINET UNIT HEATER CV CONSTANT VOLUME CY CYCLE DB DRY BULB TEMPERATURE DELF DEFLECTION DIFF DIFFUSER DN DOWN DWG DRAWING DX DIRECT EXPANSION EA EACH EAT ENTERING AIR TEMPERATURE EF EXHAUST FAN EFF EFFICIENCY EHC ELECTRIC HEAT COIL ESP EXTERNAL STATIC PRESSURE ET EXPANSION TANK EUH ELECTRIC UNIT HEATER EWT ENTERING WATER TEMPERATURE EXH EXHAUST F.D. FLOOR DRAIN FA FREE AREA FCU FAN COIL UNIT FD FIRE DAMPER FLEX FLEXIBLE FM FLOW METER FP FAN POWERED BOX FPM FEET PER MINUTE FT FEET FT2 SQUARE FEET FT3 CUBIC FEET °F DEGREES FARENHEIT GA GAUGE GC GENERAL CONTRACTOR GE GENERAL EXHAUST GPM GALLONS PER MINUTE GR GRILLE *H ENTHAPLY DIFFERENCE HC HEATING COIL HORIZ HORIZONTAL HP HORSEPOWER HR HOUR HU HUMIDIFIER HVAC HEATING VENTILATION & AIR CONDITIONING HX HEAT EXCHANGER MECHANICAL ABBREVIATIONS HZ HERTZ IF INJECTION FAN IN INCHES INSUL INSULATION ISDL ISOLATION KE KITCHEN EXHAUST KW KILOWATT LAT LEAVING AIR TEMPERATURE LBS POUNDS LF LINEAR FEET LLC LIQUID LEVEL CONTROLLER LWT LEAVING WATER TEMPERATURE MAT MIXED AIR TEMPERATURE MAX MAXIMUM MIN MINIMUM N.C. NORMALLY CLOSED N.O. NORMALLY OPEN NC NOISE CRITERIA NIC NOT IN CONTRACT NK NECK NPSH NET POSITIVE SUCTION HEAT NTS NOT TO SCALE OA OUTSIDE AIR OAI OUTSIDE AIR INTAKE OBD OPPOSED BLADE DAMPER OD OUTSIDE DAMPER OV OUTLET VELOCITY P PUMP PD PRESSURE DROP PH PHASE PRESS PRESSURE PRV PRESSURE REDUCING VALVE PSIG POUNDS PER SQUARE INCH ΔP PRESSURE DIFFERENTIAL RA RETURN AIR REFRIG REFRIGERANT REG REGISTER RET RETURN RF RELIEF / RETURN FAN RH RELATIVE HUMIDITY RM ROOM RO REVERSE OSMOSIS RPM REVOLUTIONS PER MINUTE RTU ROOFTOP UNIT SA SUPPLY AIR SD SMOKE DAMPER SF SUPPLY FAN SM SHEET METAL SP STATIC PRESSURE SQ. FT. SQUARE FEET SS STAINLESS STEEL ST SOUND TRAP T TANK TC TEMPERATURE CONTROL TE TOILET EXHAUST TG TRANSFER GRILLE TSP TOTAL STATIC PRESSURE TYP TYPICAL ΔT TEMPERATURE DIFFERENTIAL UH UNIT HEATER V VOLTAGE VAV VARIABLE AIR VOLUME VD VOLUME DAMPER VEL VELOCITY VFD VARIABLE FREQUENCY DRIVE VIB VIBRATION W WATT WB WET BULB TEMPERATURE WC WATER COLUMN WMS WIRE MESH SCREEN WP WORKING PRESSURE SHEET INDEX - MECHANICAL Sheet Number Sheet Name Current Revision Current Revision Date M0.00 LEAD SHEET M1.01 DEMOLITION PLAN M1.02 DUCT AND PIPING PLAN AIR DISTRIBUTION SCHEDULE MARK MANUFACTURER MODEL PURPOSE FACE SIZE INLET SIZE REMARKS B <varies> <varies> <varies> <varies> <varies> <varies> S PRICE APDDR RETURN 24x24 8 <varies> GENERAL NOTES: A. EQUIVALENTS BY TITUS, KRUEGER, TUTTLE AND BAILEY, NAILOR, OR AS LISTED IN SPECIFICATIONS B. PROVIDE VOLUME DAMPERS AT TAKE-OFF FOR EACH GRILLE C. ALL AIR DISTRIBUTION DEVICES SHALL BE ALUMINUM D. THE PRICE MODELS SCHEDULED HERE ARE BASIS OF DESIGN, INCLUDING GENERATED NOISE. PROPOSED SUBSTITUTIONS WILL BE JUDGED BY THOSE CRITERIA ALSO REMARKS: 1. PROVIDE WITH OFF-WHITE ENAMEL FINISH 2. PROVIDE WITH TRIM TO MATCH CEILING TYPE. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR CEILINGS. PROVIDE PLASTER FRAME IN HARD CEILINGS. 3. PROVIDE DIFFUSER/GRILLE WITH ROUND NECK OR PROVIDE SQUARE TO ROUND TRANSITION 4. ALL CEILING MOUNTED RETURN GRILLES SHALL BE FULL FACED. NO LAY-IN PANELS ALLOWED NOT TO SCALE DETAIL -SUPPLY, RETURN & EXHAUST AIR TAKE-OFF2 NOT TO SCALE DETAIL -TYPICAL DUCT HANGERS3 NOT TO SCALE DETAIL -NON-RATED DUCT PENETRATION4 10/03/2025 Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A 5 7 10.1 J K 4 6 F H BLOOD DRAWING 402 INT. 420A INT. 420C CORRIDOR 133 INT. 420D INT. 420E T.B. / INT. 420F CORRIDOR 109 HIV 403 EXAM 413 EXAM 414 STER 415 MEDICAL SUPPLIES 416 PHARM. 417 LIBRARY 108 OFFICE 110 OFFICE 111OFFICE 424 OFFICE 425 OFFICE 426 OFFICE 427 OFFICE 428 MED. REC. 431 FIN. INT. 432 CLINIC MGR. 401 TOILET 419 TOILET 418 LAB 411 HEALTH ED. OFFICE 404 LAB TECH. 409 INT. 420B PATIENT ED. 405 LOBBY 400 SUPPORT 430 CLERICAL 433 SUPPORT 429 CLERICAL 434 45x1430x1430x1422x14 18x12 10x10 14x12 8x88x8 38x14 VAV-1-27 VAV-1-3595 75 75 95 75 75 95 75 495 495 495 170 170 165 165 275 275 T 1-27 T 1-35 1 1 1 This drawing and the design shown is the property of Smith Sinnett Architecture, P.A. the reproduction or use of this property without the written consent of the Architect is prohibited. Any infringement of the ownership rights will be subject to legal action. All copies of this drawing must be returned to the Architect at the completion of the contract.Smith Sinnett Architecture, P.A. 2025THIS DRAWING IS FORMATTED TO BE PRINTED ON A 30" X 42" SHEETDRAWN BY: CHECKED BY: DESCRIPTIONDATEID T 919 781 8582 4600 Lake Boone Trail Suite 205 Raleigh, NC 27607 info@smithsinnett.com ITB 367-OC5452C:\Users\dlowry\OneDrive - Progressive Design Collaborative, Ltd\Documents\25027 Orange County Southern Health_MEP_R24_dlowryPDCBIM.rvt10/3/2025 8:59:59 AMM1.01ORANGE COUNTY HELATH DEPARTMENT IMPROVEMENTSDEMOLITION PLANSOUTHERN HUMAN SERVICES HEALTH CLINIC2024008 03 OCT 20252501 Homestead Rd, Chapel Hill, NC. 27516CONSTRUCTION DOCUMENTJAV JTB 0 2' 4' 8' 1/4" = 1'-0" DEMOLITION PLAN1 KEYNOTES: 1. DISCONNECT BRANCH DUCT AND REMOVE DOWNSTREAM FLEX DUCT AND DIFFUSER/GRILLE. GENERAL NOTES: A. WHERE EXISTING EQUIPMENT, DUCT, AND PIPING IS BEING REMOVED, REMOVE ALL EXISTING HANGERS, RODS, AND SUPPORTING HARDWARE. B. PATCH AND PAINT ALL SURFACES AND FINISHES IMPACTED BY THE WORK. 10/03/2025 Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A 5 7 10.1 J K 4 6 F H PHARM. 417 MEDICAL SUPPLIES 416 INT. 420A HIV 403 EXAM 413 EXAM 414 STER 415 CORRIDOR 109 LIBRARY 108 OFFICE 110 OFFICE 111 OFFICE 424OFFICE 425 OFFICE 426 OFFICE 427 OFFICE 428 MED. REC. 431 FIN. INT. 432 T.B. / INT. 420F INT. 420D INT. 420C CLINIC MGR. 401 TOILET 419 TOILET 418 LAB 411 BLOOD DRAWING 402 HEALTH ED. OFFICE 404 LAB TECH. 409 CORRIDOR 133 INT. 420E PATIENT ED. 405 LOBBY 400 SUPPORT 430 CLERICAL 433 SUPPORT 429 CLERICAL 434 38x14 VAV-1-35 VAV-1-27 495 75 495 75 95 495165 170 170 165 75 T 1-35 T 1-27 S 135 S 140 B 140 B 13510x8 8ø 8ø 1 1 1 B 170 S 170 This drawing and the design shown is the property of Smith Sinnett Architecture, P.A. the reproduction or use of this property without the written consent of the Architect is prohibited. Any infringement of the ownership rights will be subject to legal action. All copies of this drawing must be returned to the Architect at the completion of the contract.Smith Sinnett Architecture, P.A. 2025THIS DRAWING IS FORMATTED TO BE PRINTED ON A 30" X 42" SHEETDRAWN BY: CHECKED BY: DESCRIPTIONDATEID T 919 781 8582 4600 Lake Boone Trail Suite 205 Raleigh, NC 27607 info@smithsinnett.com ITB 367-OC5452C:\Users\dlowry\OneDrive - Progressive Design Collaborative, Ltd\Documents\25027 Orange County Southern Health_MEP_R24_dlowryPDCBIM.rvt10/3/2025 9:00:01 AMM1.02ORANGE COUNTY HELATH DEPARTMENT IMPROVEMENTSDUCT AND PIPING PLAN SOUTHERN HUMAN SERVICES HEALTH CLINIC2024008 03 OCT 20252501 Homestead Rd, Chapel Hill, NC. 27516CONSTRUCTION DOCUMENTJAV JTB 0 2' 4' 8' 1/4" = 1'-0" DUCTWORK AND PIPING PLAN1 KEYNOTES:GENERAL NOTES: A. ALL EXTERIOR SUPPORT HARDWARE SHALL BE HOT-DIP GALVANIZED. B. TAB SHALL RE-BALANCE AFFECTED VAV BOXES AND RETURN GRILLES. 1. COORDINATE DIFFUSER/GRILLE LOCATION IN CEILING GRID WITH EXISTING CONDITIONS AND ARCHITECTURAL DRAWINGS. 10/03/2025 Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A ABBREVIATIONS ABBREV. A AC A/C ADA AFF AFG AIC AL ANSI ATSC ATS A/V AWG BAS BFC C CB CCTV CKT CT CU D DB DC DL DISC E ECB EWC EX FUT FA FACP FATC FDR GAA GAP GEN GEC GFI GFCI GFEP GFP GND GRS HH HOA HP IEEE IG KCMIL KV KVA KW KWH LC LS LSIG MAX MCB MCC MDP MIN MH MLO MTS N/A NC NEC NEMA N or NEUT NFPA NIC NO O/H P PA PB PC PH PT RC RSC SEC SPD SW SWBD SWGR TC TEMP TGB TGMB TTB TV TYP. U/C U/G UGE UL UON UPS V VFD WG WP XFER XFMR DEFINITION AMPS, AMPERE, AMPERAGE ABOVE COUNTER ALTERNATING CURRENT AMERICANS WITH DISABILITIES ACT ABOVE FINISHED FLOOR ABOVE FINISHED GRADE AMPERE INTERRUPTING CURRENT ALUMINUM AMERICAN NATIONAL STANDARD INSTITUTE AUTOMATIC TRANSFER SWITCH CONTROL AUTOMATIC TRANSFER SWITCH AUDIO/VISUAL AMERICAN WIRE GAUGE BUILDING AUOTMATION SYSTEM BELOW FINISHED CEILING CONDUIT CIRCUIT BREAKER CLOSED CIRCUIT TELEVISION CIRCUIT CURRENT TRANSFORMER COPPER DIMMING OR DIMMER DISTRIBUTION BOARD DIRECT CURRENT DAY-LIGHTING DISCONNECT SWITCH EMERGENCY ENCLOSED CIRCUIT BREAKER ELECTRIC WATER COOLER EXISTING FUTURE FIRE ALARM FIRE ALARM CONTROL PANEL FIRE ALARM TERMINAL CABINET FEEDER GENERATOR ALARM ANNUNCIATOR GENERATOR ALARM PANEL GENERATOR GROUNDING ELECTRODE CONDUCTOR GROUND FAULT INTERRUPTER GROUND FAULT CIRCUIT INTERRUPTER GROUND FAULT EQUIPMENT PROTECTION GROUND FAULT PROTECTION GROUND GALVANIZED RIGID STEEL HAND HOLE HAND-OFF AUTOMATIC HORSEPOWER INSTITUE OF ELECTRICAL AND ELECTRONICS ENGINEERS ISOLATED GROUND THOUSAND CIRCULAR MILS KILOVOLT KILOVOLT AMPS KILOWATT KILOWATT HOURS LIGHTING CONTACTOR LOUD SPEAKER LONG TIME, SHORT TIME, INSTANTANEOUS AND GROUND FAULT PROTECTION MAXIMUM MAIN CIRCUIT BREAKER MOTOR CONTROL CENTER MAIN DISTRIBUTION PANEL MINIMUM MAN HOLE MAIN LUGS ONLY MANUAL TRANSFER SWITCH NOT APPLICABLE NORMALLY CLOSED NATIONAL ELECTRIC CODE NATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATION NEUTRAL NATIONAL FIRE PROTECTION ASSOCIATION NOT IN CONTRACT NORMALLY OPEN OVER HEAD POLE PUBLIC ADDRESS PULL BOX PHOTOCELL PHASE POTENTIAL TRANSFORMER POTENTIAL TRANSFORMER RECEPTACLE CONTACTOR RIGID STEEL CONDUIT SECURITY SURGE PROTECTIVE DEVICE SWITCH SWITCHBOARD SWITCHGEAR TIME CLOCK TEMPORARY TECHNOLOGY GROUND BAR TECHNOLOGY MAIN GROUND BAR TELEPHONE TERMINAL BOARD TELEVISION TYPICAL UNDER COUNTER UNDERGROUND UNDERGROUND ELECTRIC UNDERWRITERS' LABORATORIES UNLESS OTHERWISE NOTED UNINTERRUPTABLE POWER SUPPLY VOLTS, VOLTAGE VARIABLE FREQUENCY DRIVE WIRE GUARD WEATHERPROOF TRANSFER TRANSFORMER GENERAL NOTES A. THE ELECTRICAL CONTRACTOR SHALL COORDINATE ANY AND ALL WORK WITH OTHER TRADES INVOLVED IN THE PROJECT, PRIOR TO THE INSTALLATION OF HIS EQUIPMENT SO AS TO AVOID CONFLICTS DURING CONSTRUCTION AND ALLOW FOR OPTIMUM MAINTENANCE AND WORKING SPACE. B. ALL WORK AND MATERIAL SHALL BE PROVIDED IN ACCORDANCE WITH STATE, LOCAL AND NATIONAL CODES AND ORDINANCES. C. EACH CONTRACTOR SHALL PROVIDE HIS OWN SUPPORT OF ALL DEVICES AND EQUIPMENT PROVIDED BY HIM AND SHALL SUPPORT SUCH EQUIPMENT PER APPROVED GOVERNING CODES OR PER APPROVAL OF THE ENGINEER. UNACCEPTABLE WORKMANSHIP OR MATERIALS SHALL BE REPLACED AT THE REQUEST OF THE ENGINEER AT THE CONTRACTOR'S EXPENSE. D. ALL WIRE AND CONDUIT SIZES ARE BASED ON 75°C THHN OR THWN WIRE UNLESS OTHERWISE NOTED. E. WHERE ELECTRICAL EQUIPMENT PENETRATES EXTERIOR WALLS OR THE ROOF, THEY SHALL BE PROPERLY SEALED WITH METHODS APPROVED BY THE ENGINEER. SUBMIT DETAIL OF PROPOSED SEALING METHODS. F. CONDUCTORS FOR BRANCH CIRCUITS SHALL BE SIZED TO PREVENT VOLTAGE DROP EXCEEDING 3% AT THE FARTHEST OUTLET OF POWER, HEATING AND LIGHTING LOADS, OR ANY COMBINATION OF SUCH LOADS. THE MAXIMUM TOTAL VOLTAGE DROP ON BOTH FEEDERS AND BRANCH CIRCUITS TO THE FARTHEST OUTLET SHALL NOT EXCEED 5%. 1. WHERE THE CONDUCTOR LENGTH FROM THE PANEL TO THE FIRST OUTLET ON A 120V CIRCUIT EXCEED 50'-0" THE BRANCH CIRCUIT CONDUCTORS FROM THE PANEL TO THE FIRST OUTLET SHALL NOT BE SMALLER THAN #10AWG. INCREASE THE BRANCH CIRCUIT CONDUCTOR SIZE AN ADDITIONAL WIRE SIZE FOR EACH ADDITIONAL 125' FOR THE ENTIRE CIRCUIT. THE GROUND CONDUCTOR SIZE SHALL BE INCREASED PROPORTIONALLY TO THE INCREASED PHASE CONDUCTORS AS PER NEC 2020 250.122 (B). 2. WHERE THE CONDUCTOR LENGTH FROM THE PANEL TO THE FIRST OUTLET ON A 277V CIRCUIT EXCEEDS 125'-0", THE BRANCH CIRCUIT CONDUCTORS FROM THE PANEL TO THE FIRST OUTLET SHALL NOT BE SMALLER THAN #10 AWG. CONDUCTOR SIZE OF REMAINING BRANCH CIRCUIT SHALL INCREASE AS NEEDED TO MEET ABOVE VOLTAGE DROP LIMITATIONS. THE GROUND CONDUCTOR SIZE SHALL BE INCREASED PROPORTIONALLY TO THE INCREASED PHASE CONDUCTORS AS PER NEC 2020 250.122(B). G. ELECTRICAL CONTRACTOR SHALL VISIT SITE PRIOR TO BID. METHOD OF COMPLIANCE: ELECTRICAL SYSTEM AND EQUIPMENT PRESCRIPTIVE__X__ PERFORMANCE_____ LIGHTING SCHEDULE Total wattage per fixture - Varies - See Fixture Schedule Number of ballasts in fixture - See Specifications. Ballast type used in the fixture - See Specifications. Number of lamps in fixture - See Fixture Schedule. Lamp type required in fixture - See Fixture Schedule. To the best of my knowledge and belief, the design of this building complies with the electrical system and equipment requirements of the 2018 North Carolina State Building Code, Energy Conservation Code. DESIGNER STATEMENT: ___ 406.6 Provision of Dedicated Outdoor HVAC Air System ___ 406.5 On-Site Supply of Renewable Energy ___ 406.4 Enhanced Lighting Controls ___ 406.3 Reduced Lighting Power Density ___ 406.2 More Efficient HVAC Performance ADDITIONAL PRESCRIPTIVE COMPLIANCE Total exterior wattage specified versus allowed: N/A watts versus N/A watts Total interior wattage specified versus allowed: 133 watts versus 301 watts ENERGY CODE: PRESCRIPTIVE_____ PERFORMANCE_____ASHRAE 90.1: ___ 406.7 High Efficiency Service Water Heating X LOAD SUMMARY (-0.05) KVA NEGLIBLE LOAD AFFECTING BUILDING SERVICE (-0.03) KVA TOTAL DIVERSITYCONNECTED KVA DEMAND KVA 0 x 1.0 0 x 0.5{ } (-0.18) (0.05) 0.13 0.07 0 LIGHTING REMOVED RECEPTACLES REMOVED LIGHTING ADDED RECEPTACLES ADDED (-0.23) (-0.05) 0.16 0.07 0 x1.25 x1.0 x1.25 SYMBOL LEGEND QUADRUPLEX GROUNDING TYPE RECEPTACLES IN A DOUBLE GANG BOX. MOUNT AT 16" AFF TO BOTTOM OF OUTLET UNLESS OTHERWISE NOTED. DESCRIPTION REMARKS LUMINAIRE - LETTER DESIGNATES TYPE NIGHT LIGHT / EMERGENCY LIGHT FIXTURE - LETTER DESIGNATES TYPE DUPLEX GROUNDING TYPE RECEPTACLE - AT 16" ABOVE FINISHED FLOOR TO BOTTOM OF OUTLET, UNLESS OTHERWISE NOTED DUPLEX RECEPTACLE - GROUND FAULT INTERRUPTION TYPE -INSTALL AT 16" ABOVE FINISHED FLOOR TO BOTTOM OF OUTLET, UNLESS OTHERWISE NOTED. SEE FIXTURE SCHEDULE SEE FIXTURE SCHEDULE HUBBELL 5362-X WITH 97101 COVER HUBBELL GF-5362-X WITH STAINLESS STEEL S26 WALLPLATE HUBBELL 5362-X WITH 97101 COVER DATA OUTLET - REFER TO PLANS AND SCHEDULES. # INDICATES QUANTITY OF DROPS AT EACH OUTLET. WERE NO NUMBER IS INDICATED, PROVIDE A MINIMUM OF TWO DATA DROPS. SYMBOL GFI # DUAL TECHNOLOGY WALL SWITCH SENSOR - COVERAGE: MAJOR MOTION 35'x30', MINOR MOTION 20'x15'. TIME DELAYS OF NO LESS THAN 15 MINUTES. MOUNT AT +48" TO TOP OF OUTLET BOX. INSTALL AS PER MANUFACTURER'S INSTRUCTIONS. OR WATTSTOPPER DSW-301 OR APPROVED EQUAL BY P&S OR LEVITON.OS D D3 3 SLIDE TYPE DIMMER SWITCH WITH ON/OFF FOR 0-10V LED AS NEEDED. VERIFY WITH FIXTURE PROVIDER FOR COMPATIBLE SWITCH TYPES. 3-WAY SWITCH - INSTALL AT 48" ABOVE FINISHED FLOOR TO TOP OF OUTLET. SWITCH COLOR SELECTED BY ARCHITECT. SINGLE POLE TOGGLE SWITCH - 48" ABOVE FINISHED FLOOR TO TOP OF OUTLET, UNLESS OTHERWISE NOTED. OR 3-WAY SLIDE TYPE DIMMER SWITCH WITH ON/OFF FOR 0-10V LED AS NEEDED. VERIFY WITH FIXTURE PROVIDER FOR COMPATIBLE SWITCH TYPES. 120/208 VOLT PANELBOARD WITH NEUTRAL AND GROUND BUS ACCESSORIES. SURGE PROTECTIVE DEVICESPD J WIRING AND CONDUIT INSTALLED CONCEALED IN WALL SPACE OR ABOVE FINISHED CEILING HOME RUN CIRCUIT TO PANELBOARD - NUMBER OF ARROWS INDICATES NUMBER OF CIRCUITS JUNCTION BOX WITH REMOVABLE COVER - SIZE PER NATIONAL ELECTRICAL CODE UNSWITCHED WIRING AND CONDUIT LEG ON LIGHTING PLANS. UNDER FLOOR WIRING AND CONDUIT ON POWER PLANS. UNDER GROUND WIRING AND CONDUIT ON SITE PLANS. DISCONNECT SWITCH, HEAVY DUTY 277/480 VOLT PANELBOARD WITH NEUTRAL AND GROUND BUS ACCESSORIES. EXISTING CEILING MOUNTED LIGHT FIXTURE TO BE REMOVED EXISTING LIGHT SWITCH TO BE REMOVED EXISTING DUPLEX RECEPTACLE TO BE REMOVED S FIRE ALARM STROBE - WALL MOUNTED SHEET INDEX - ELECTRICAL Sheet Number Sheet Name Current Revision Current Revision Date E0.00 ELECTRICAL LEAD SHEET E1.01 ENLARGED PLANS E1.02 SCHEDULES & DETAILS This drawing and the design shown is the property of Smith Sinnett Architecture, P.A. the reproduction or use of this property without the written consent of the Architect is prohibited. Any infringement of the ownership rights will be subject to legal action. All copies of this drawing must be returned to the Architect at the completion of the contract.Smith Sinnett Architecture, P.A. 2025THIS DRAWING IS FORMATTED TO BE PRINTED ON A 30" X 42" SHEETDRAWN BY: CHECKED BY: DESCRIPTIONDATEID T 919 781 8582 4600 Lake Boone Trail Suite 205 Raleigh, NC 27607 info@smithsinnett.com ITB 367-OC5452C:\Users\dlowry\OneDrive - Progressive Design Collaborative, Ltd\Documents\25027 Orange County Southern Health_MEP_R24_dlowryPDCBIM.rvt10/3/2025 9:00:01 AME0.00ORANGE COUNTY HELATH DEPARTMENT IMPROVEMENTSELECTRICAL LEAD SHEETSOUTHERN HUMAN SERVICES HEALTH CLINIC2024008 03 OCT 20252501 Homestead Rd, Chapel Hill, NC. 27516CONSTRUCTION DOCUMENTTMC JTB 10/03/2025 Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A SSSSOS SE1.01 2 Sim CORRIDOR 133 INT. 420D INT. 420C INT. 420E T.B. / INT. 420F CORRIDOR 109 FIN. INT. 432 CLERICAL 433 INT. 420A 4 5 4 5 OS OS AE AE A AE 7 7 7 6 6 D 1 1 3 1 2 3 3 OS 2 This drawing and the design shown is the property of Smith Sinnett Architecture, P.A. the reproduction or use of this property without the written consent of the Architect is prohibited. Any infringement of the ownership rights will be subject to legal action. All copies of this drawing must be returned to the Architect at the completion of the contract.Smith Sinnett Architecture, P.A. 2025THIS DRAWING IS FORMATTED TO BE PRINTED ON A 30" X 42" SHEETDRAWN BY: CHECKED BY: DESCRIPTIONDATEID T 919 781 8582 4600 Lake Boone Trail Suite 205 Raleigh, NC 27607 info@smithsinnett.com ITB 367-OC5452C:\Users\dlowry\OneDrive - Progressive Design Collaborative, Ltd\Documents\25027 Orange County Southern Health_MEP_R24_dlowryPDCBIM.rvt10/3/2025 9:00:03 AME1.01ORANGE COUNTY HELATH DEPARTMENT IMPROVEMENTSENLARGED PLANSSOUTHERN HUMAN SERVICES HEALTH CLINIC2024008 03 OCT 20252501 Homestead Rd, Chapel Hill, NC. 27516CONSTRUCTION DOCUMENTTMC JTB GENERAL NOTES: A. REFER TO ELECTRICAL LEAD SHEET E0.00 FOR SYMBOLS, ABBREVIATIONS AND NOTES. B. THE ELECTRICAL CONTRACTOR SHALL COORDINATE ANY AND ALL WORK WITH OWNER, PRIOR TO INSTALLATION OF THE NEW EQUIPMENT, SO TO AVOID CONFLICTS DURING CONSTRUCTION AND TO ALLOW FOR OPTIMUM MAINTENANCE AND WORKING SPACE. C. CONDUIT/WIRE ROUTING SHOWN IS FOR INFORMATIONAL PURPOSES ONLY, FOR THE CLARIFICATION OF SCOPE. EXACT EXISTING ROUTING OR NEW INSTALLATION SHALL BE FIELD VERIFIED. NEW WORK KEYNOTES: 4. CONNECT NEW RECEPTACLES TO EXISTING RECEPTACLE CIRCUIT THIS AREA. 5. PROVIDE NEW DATA DEVICE. COORDINATE CAT-6 CONNECTION WITH OWNER. 6. PROVIDE NEW FIRE ALARM STROBE COMPATIBLE WITH EXISTING FIRE ALARM SYSTEM. VERIFY PROPER OPERATION WITH SYSTEM. 7. PROVIDE NEW LIGHT FIXTURE AND CONNECT TO EXISTING LIGHTING CIRCUIT. PROVIDE AND REWORK SWITCHING CONTROL AS INDICATED. 0 4' 8'16' 3/32" = 1'-0" REFERENCE PLAN1 DEMOLITION KEYNOTES: 1. DISCONNECT AND REMOVE LIGHT FIXTURES. SECURE CIRCUITRY FOR REUSE. 2. DISCONNECT AND REMOVE LIGHT SWITCH. 3. DISCONNECT AND REMOVE RECEPTACLES, ENSURE OTHER DEVICES SAME CIRCUIT REMAIN FUNCTIONAL. 0 2' 4' 8' 1/4" = 1'-0" ENLARGED POWER & DATA PLAN2 0 2' 4' 8' 1/4" = 1'-0" ENLARGED LIGHTING & FIRE ALARM PLAN3 0 2' 4' 8' 1/4" = 1'-0" ENLARGED DEMOLITION PLAN4 10/03/2025 Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A ANSI/UL1479 (ASTM E814)CAN/ULC S115 F Ratings —1 and 2 Hr (See Items 1 and 3) F Ratings — 1 and 2 Hr (See Items 1 and 3) T Rating — 0 Hr FT Rating — 0 Hr L Rating at Ambient — Less Than 1 CFM/sq ft FH Ratings —1 and 2 Hr (See Items 1 and 3) L Rating at 400 F — Less Than 1 CFM/sq ft FTH Rating — 0 Hr L Rating at Ambient — Less Than 1 CFM/sq ft L Rating at 400 F — Less Than 1 CFM/sq ft System No. W-L-1054 C R Classified by Underwriters Laboratories, Inc. to UL 1479 and CAN/ULC-S115 US 1. Wall Assembly — The 1 or 2 hr fire-rated gypsum wallboard/stud wall assembly shall be constructed of the materials and in the manner specified in the individual U300 or U400 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall include the following construction features: A. Studs — Wall framing may consist of either wood studs or steel channel studs. Wood studs to consist of nom 2 by 4 in. (51 by 102 mm) lumber spaced 16 in. (406 mm) OC. Steel studs to be min 2-1/2 in. (64 mm) wide and spaced max 24 in. (610 mm) OC. When steel studs are used and the diam of opening exceeds the width of stud cavity, the opening shall be framed on all sides using lengths of steel stud installed between the vertical studs and screw-attached to the steel studs at each end. The framed opening in the wall shall be 4 to 6 in. (102 to 152 mm) wider and 4 to 6 in. (102 to 152 mm) higher than the diam of the penetrating item such that, when the penetrating item is installed in the opening, a 2 to 3 in. (51 to 76 mm) clearance is present between the penetrating item and the framing on all four sides. B. Gypsum Board* — 5/8 in. (16 mm) thick, 4 ft (122 cm) wide with square or tapered edges. The gypsum board type, thickness, number of layers, fastener type and sheet orientation shall be as specified in the individual U300 or U400 Series Design in the UL Fire Resistance Directory. Max diam of opening is 32-1/4 in. (819 mm) for steel stud walls. Max diam of opening is 14-1/2 in. (368 mm) for wood stud walls. The F and FH Ratings of the firestop system are equal to the fire rating of the wall assembly. 2. Through-Penetrants — One metallic pipe, conduit or tubing to be installed either concentrically or eccentrically within the firestop system. The annular space shall be min 0 in. to max 2-1/4 in. (57 mm). Pipe may be installed with continuous point contact. Pipe, conduit or tubing to be rigidly supported on both sides of wall assembly. The following types and sizes of metallic pipes, conduits or tubing may be used: A. Steel Pipe — Nom 30 in. (762 mm) diam (or smaller) Schedule 10 (or heavier) steel pipe. B. Iron Pipe — Nom 30 in. (762 mm) diam (or smaller) cast or ductile iron pipe. C.Conduit — Nom 4 in. (102 mm) diam (or smaller) steel electrical metallic tubing or 6 in. (152 mm) . diam steel conduit. D.Copper Tubing — Nom 6 in. (152 mm) diam (or smaller) Type L (or heavier) copper tubing. E. Copper Pipe — Nom 6 in. (152 mm) diam (or smaller) regular (or heavier) copper pipe. 3. Fill, Void or Cavity Material* — Sealant — Min 5/8 in. (16 mm) thickness of fill material applied within the annulus, flush with both surfaces of wall. At the point or continuous contact locations between pipe and wall, a min 1/2 in. (13 mm) diam bead of fill material shall be applied at the pipe wall interface on both surfaces of wall. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — FS-One Sealant or FS-ONE MAX Intumescent Sealant *Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively. SECTION A-A A A 1A 3 2 1B JUNCTION BOX ATTACHED TO STRUCTURE BRANCH CIRCUIT CONDUIT (1/2" EMT) FOR EACH FIXTURE, PROVIDE TWO STEEL WIRE SUPPORTS TO STRUCTURE, ONE WIRE AT EACH CORNER OF THE FIXTURE, THEN SCREW FIXTURE TO THE MAIN RUNNERS OF THE LAY-IN CEILING TRACK, AT THE FOUR CORNERS, WITH SHEET METAL SCREWS. A. 6 FEET LENGTH OF FLEXIBLE CONDUIT TO ALLOW FOR RELOCATION. INCLUDE GROUND WIRE. ALL CONDUCTORS #12 AWG COPPER, MAXIMUM OF THREE(3) FLEXIBLE RUNS PER JUNCTION BOX. LAY-IN TYPE TROFFER GRID TYPE INVERTED "T" CEILING ACOUSTICAL PANEL BRANCH CIRCUIT CONDUIT 4" SQUARE DEVICE BOX BOX DEVICE COVER WITH RAISED RING OF PROPER DEPTH AND TYPE FOR WALL CONSTRUCTION. RING TO FINISH FLUSH WITH WALL. DEVICE TRIM PLATE 1 #12 AWG SOLID COPPER GREEN INSULATED JUMPER TO DEVICE GROUNDING SCREW 1 #12 AWG SOLID COPPER GREEN INSULATED JUMPER TO BOX BONDING SCREW MAKE CIRCUIT JOINT WITH TWIST-ON CONNECTOR AND CONNECT TO DEVICE WITH SINGLE LEADS ANY 24VDC CEILING/WALL SENSOR WATTSTOPPER WT1105 ULTRASONIC OCCUPANCY SENSOR 1100 SQ. FT. 360°, TWO SIDED COVERAGE LIGHTING CIRCUIT Wall Hot N White Black Switch Red White (Neutral) Red BlueBlackRedPOWER PACK LIGHTING LOAD OCCUPANCY SENSORS WITHOUT ISOLATED RELAY WIRING DIAGRAM (EQUALS: HUBBELL, SENSOR SWITCH) GENERAL NOTES: OCCUPANCY SENSOR SINGLE LEVEL WIRING DIAGRAM (EQUALS: WATTSTOPPER, HUBBELL, SENSOR SWITCH) ANY 24VDC WALL SWITCH/SENSOR Ground Green Green/YellowGround Line Black Red (Load) Neutral LIGHTING LOAD DSW-100 DUAL TECHNOLOGY WALL SWITCH SENSOR 35' x 30' PIR MAJOR MOTION ULTRASONIC 20' x 20' 20' x 15' PIR MINOR MOTION ULTRASONIC 15' x 15' ( )OS WATTSTOPPER WT2255 ULTRASONIC OCCUPANCY SENSOR 90 LINEAR FT. 360°, TWO SIDED COVERAGE WATTSTOPPER WT605 ULTRASONIC OCCUPANCY SENSOR 600 SQ. FT. 180°, ONE SIDED COVERAGE WATTSTOPPER DT305 DUAL TECHNOLOGY OCCUPANCY SENSOR 1100 SQ. FT. 360°, TWO SIDED COVERAGE WATTSTOPPER WPIR PASSIVE IFRARED OCCUPANCY SENSOR 300 SQ. FT. 360° COVERAGE A. ALL SENSOR LOCATIONS ARE APPROXIMATE. REFER TO MANUFACTURER'S INSTALLATION INSTRUCTIONS PRIOR TO INSTALLATION. B. ULTRASONIC CEILING MOUNTED SENSORS SHALL NOT BE LOCATED WITHIN 6'-0" OF SUPPLY/RETURN GRILLES. C. CONTRACTOR IS RESPONSIBLE FOR PROPER SENSITIVITY AND TIME DELAY SETTINGS, VERIFICATION OF MANUFACTURER'S RECOMMENDED PLACEMENT AND FIELD VERIFICATION OF CIRCUITS WITH RESPECT TO POWER PACK PLACEMENT. D. CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFICATION OF REQUIRED NUMBER OF POWER PACKS. POWER PACKS SHALL BE INSTALLED IN A 4" SQUARE JUNCTION BOX. E. ONE POWER PACK IS REQUIRED FOR EACH CIRCUIT THAT IS TO BE CONTROLLED. F. MAXIMUM NUMBER OF SENSORS THAT CAN BE WIRED IN PARALLEL TO A SINGLE POWER PACK IS DEPENDENT ON SENSOR MODEL. (SEE INDIVIDUAL DATA SHEETS FOR mA CONSUMPTION.) G. SENSOR LAYOUT DRAWINGS AND PRODUCT DATA SHEETS ARE REQUIRED AS PART OF SHOP DRAWING SUBMITTALS. H. ALL OCCUPANCY SENSOR WIRING SHALL BE WIRED IN ACCORDANCE WITH MANUFACTURERS INSTALLATION INSTRUCTIONS. I. REFER TO SPECIFICATION 260923. J. ALL EXPOSED WIRING SHALL BE PLENUM RATED. K. ALL WALL MOUNT STYLE SENSORS SHALL BE THE SWIVEL TYPE SO THAT IT ALLOWS FOR ADJUSTMENT. NON-SWIVEL SENSORS SHALL NOT BE ACCEPTABLE. LP-2 LP-2 NEATLY HAND WRITTEN CIRCUIT IDENTIFIER OR SYSTEM CONDUCTORS CONTAINED WITHIN COLOR CODE JUNCTION BOX COVER WITH PAINT COLORS AS INDICATED IN SPECIFICATIONS FOR SYSTEM CONTAINED WITHINNOTE: CONTRACTOR SHALL IDENTIFY JUNCTION BOX COVERS WITH ONE OF THE TWO METHODS SHOWN ABOVE, BUT NOT BOTH. ALL JUNCTION BOX COVERS SHALL BE CONSISTENTLY IDENTIFIED ACROSS THE ENTIRE PROJECT. JUNCTION BOX LABELING FIRE ALARM DEVICE MOUNTING COORDINATE WITH LOCAL AHJ PRIOR TO ROUGH-IN HORN/STROBE NFPA 72 AND ADA DEVICE INSTALLATION REQUIREMENTS 3'-0" MINIMUM ANNUNCIATOR MANUAL PULL STATION 5'-0" MAXIMUM 0'-4" MINIMUM SMOKE/ HEAT MOUNT ON A BOX APPROVED DETECTOR 96" MAXIMUM TOP OF DEVICE 80" MINIMUM BOTTOM OF DEVICE 5'-6" FLOOR FINISHED CONTROL PANEL HORN/ STROBE AIR SUPPLY DIFFUSER OR RETURN AIR OPENING GRAPHIC CONDUIT & VISUAL DEVICES MOUNT AUDIBLE 0'-4" MINIMUM, SMOKE/ HEAT DETECTOR HORN BOXES. ON APPROVED 3'-8" (3'-6" MINIMUM, 4'-0" MAXIMUM) HINGED SIDE 1'-0" MAXIMUMSTROBEDATA OUTLET DATA OUTLET 18" FINISHED CEILING A. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING CONDUIT SLEEVES AS NEEDED TO ACCOMMODATE NEW WIRING. CABLING SHALL HAVE 2' OF SERVICE LOOP ABOVE CEILINGS. RJ-45 GENERAL NOTES: SINGLE GANG OUTLET BOX U.O.N. 3/4" CONDUIT STUBBED 12" ABOVE FINISHED CEILING. CAT-6 CABLE TO NEAREST PATCH PANEL A 24"'W X 1.9"D X 48"L RECESSED UNV LITHONIA # STAK-2X4-4000LM-80CRI-35K- COL-MIN10-ZT-MVOLT COOPER, EATON RECESSED 2' X 4' LED, 0-10V, 10% DIMMING, 80 CRI 3500K LED 4028 LUMENS 33.3W AE 24"'W X 1.9"D X 48"L RECESSED UNV LITHONIA # STAK-2X4-4000LM-80CRI-35K- COL-MIN10-ZT-MVOLT-E10W COOPER, EATON RECESSED 2' X 4' LED, 0-10V, 10% DIMMING, 80 CRI, WITH 10 WATT, 90 MINUTE EMERGENCY BATTERY 3500K LED 4028 LUMENS 33.3W MARK SIZE MOUNTING VOLT MANUFACTURER AND MODEL NO.EQUALS DESCRIPTION LAMP WATTS MTG. HGT. LIGHTING FIXTURE SCHEDULE This drawing and the design shown is the property of Smith Sinnett Architecture, P.A. the reproduction or use of this property without the written consent of the Architect is prohibited. Any infringement of the ownership rights will be subject to legal action. All copies of this drawing must be returned to the Architect at the completion of the contract.Smith Sinnett Architecture, P.A. 2025THIS DRAWING IS FORMATTED TO BE PRINTED ON A 30" X 42" SHEETDRAWN BY: CHECKED BY: DESCRIPTIONDATEID T 919 781 8582 4600 Lake Boone Trail Suite 205 Raleigh, NC 27607 info@smithsinnett.com ITB 367-OC5452C:\Users\dlowry\OneDrive - Progressive Design Collaborative, Ltd\Documents\25027 Orange County Southern Health_MEP_R24_dlowryPDCBIM.rvt10/3/2025 9:00:03 AME1.02ORANGE COUNTY HELATH DEPARTMENT IMPROVEMENTSSCHEDULES & DETAILSSOUTHERN HUMAN SERVICES HEALTH CLINIC2024008 03 OCT 20252501 Homestead Rd, Chapel Hill, NC. 27516CONSTRUCTION DOCUMENTTMC JTB NOT TO SCALE 1 OR 2 HR PENETRATION1NOT TO SCALE LAY-IN FIXTURE MOUNTING3 NOT TO SCALE RECEPTACLE GROUNDING4 NOT TO SCALE OCCUPANCY SENSOR WIRING DIAGRAMS2 NOT TO SCALE JUNCTION BOX LABELING5 NOT TO SCALE F/A DEVICE MOUNTING6 NOT TO SCALE DETAIL -DATA DISPLAY OUTLET7 10/03/2025 Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett / 2024008 Hillsborough, NC Orange County Asset Management Services GYPSUM BOARD 09 29 00 - 1 SECTION 09 29 00 - GYPSUM BOARD PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section. 1.2 SUMMARY A. This Section includes the following: 1. Interior gypsum board 2. Cement board panels. 3. Interior wall and ceiling framing B. Related Sections include the following: 1. Division 06 Section "Rough Carpentry" for wood framing and furring that supports gypsum board. 2. Division 07 Section "Thermal Insulation" for insulation and vapor retarders installed in assemblies that incorporate gypsum board. 3. Division 09 Section "Tiling" for cementitious backer units installed as substrates for ceramic tile. 1.3 SUBMITTALS A. Product Data: For each type of product indicated. B. Delegated-Design Submittal: For framing systems indicated to comply with performance requirements and design criteria, including analysis data signed and sealed by the qualified professional engineer responsible for their preparation. 1. Specify stud sizes, spacing, bracing, and fastening conditions required for each wall type. Provide a plan indicating location of wall type. 2. Include design calculations. 1.4 QUALITY ASSURANCE A. Fire-Resistance-Rated Assemblies: For fire-resistance-rated assemblies, provide materials and construction identical to those tested in assembly indicated according to ASTM E 119 by an independent testing agency. B. Fire-Test-Response Characteristics: Where fire-resistance-rated gypsum board assemblies are indicated, provide gypsum board assemblies that comply with the following requirements: 1. Fire-Resistance Ratings: As indicated by GA File Numbers in GA-600 "Fire Resistance Design Manual" or design designations in UL "Fire Resistance Directory" or in the listing of another testing and inspecting agency acceptable to authorities having jurisdiction. 2. Gypsum board assemblies indicated are identical to assemblies tested for fire resistance according to ASTM E 119 by an independent testing and inspecting agency acceptable to authorities having jurisdiction. 3. Deflection and Firestop Track: Top runner provided in fire-resistance-rated assemblies indicated is labeled and listed by UL, Warnock Hersey, or another testing and inspecting agency acceptable to authorities having jurisdiction. Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett / 2024008 Hillsborough, NC Orange County Asset Management Services GYPSUM BOARD 09 29 00 - 2 C.Above-Ceiling Observation: Architect will conduct an above-ceiling observation prior to installation of gypsum board ceilings and report any deficiencies in the Work observed. Do not proceed with installation of gypsum board to ceiling support framing until deficiencies have been corrected. 1. Notify Architect one week in advance of the date and the time when the Project, or part of the Project, will be ready for an above-ceiling observation. 1.5 STORAGE AND HANDLING A. Store materials inside under cover and keep them dry and protected against damage from weather, condensation, direct sunlight, construction traffic, and other causes. Stack panels flat to prevent sagging. 1.6 PROJECT CONDITIONS A. Environmental Limitations: Comply with ASTM C 840 requirements or gypsum board manufacturer’s written recommendations, whichever are more stringent. B. Do not install interior products until installation areas are enclosed and conditioned. C. Do not install panels that are wet, those that are moisture damaged, and those that are mold damaged. 1. Indications that panels are wet or moisture damaged include, but are not limited to, discoloration, sagging, or irregular shape. 2. Indications that panels are mold damaged include, but are not limited to, fuzzy or splotchy surface contamination and discoloration. PART 2 - PRODUCTS 2.1 PANELS, GENERAL A. Size: Provide in maximum lengths and widths available that will minimize joints in each area and that correspond with support system indicated. 2.2 STEEL FRAMING AND FURRING A. Available Manufacturers: Subject to compliance with requirements, manufacturers offering products that may be incorporated in the Work include, but are not limited to, the following: 1. Steel Framing and Furring: a. Clark Steel Framing, Inc. b. Consolidated Systems, Inc. c. Dale Industries, Inc. d. Dietrich Industries, Inc. e. Marino/Ware (formerly Marino Industries Corp.). f. National Gypsum Co.; Gold Bond Building Products Division. g. Unimast, Inc. B. Steel Framing Components for Suspended and Furred Ceilings: 1. General: Provide components complying with ASTM C 754 for conditions indicated. 2. Wire Ties: ASTM A 641, Class 1 zinc coating, soft temper, 0.062 inch thick. 3. Wire Hangers: ASTM A 641, Class 1 zinc coating, soft temper, 0.162-inch diameter. 4. Channels: Cold-rolled steel, 0.0598-inch minimum thickness of base (uncoated) metal and 7/16- inch- wide flanges, and as follows: a. Carrying Channels: 1-1/2 inches deep, 475 lb/1000 feet, unless otherwise indicated. b. Furring Channels: 3/4 inch deep, 300 lb/1000 feet, unless otherwise indicated. Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett / 2024008 Hillsborough, NC Orange County Asset Management Services GYPSUM BOARD 09 29 00 - 3 c. Finish: ASTM A 653, G 60 hot-dip galvanized coating for framing for exterior soffits and where indicated. 5. Steel Rigid Furring Channels: ASTM C 645, hat shaped, depth of 7/8 inch, and minimum thickness of base (uncoated) metal as follows: a. Thickness: Min. 0.0179 inch, unless otherwise indicated. b. Protective Coating: ASTM A 653, G 40 hot-dip galvanized coating. C. Steel Framing for Walls and Partitions: 1. General: Provide steel framing members complying with the following requirements: a. Protective Coating: ASTM A 653, G 40 hot-dip galvanized coating. 2. Steel Studs and Runners: ASTM C 645, with flange edges of studs bent back 90 degrees and doubled over to form 3/16-inch- wide minimum lip (return), and complying with the following requirements for minimum thickness of base (uncoated) metal and for depth: a. Thickness: minimum 30 mil. b. Depth: 3-5/8 inches, unless otherwise indicated. Provide 1-1/2", 2-1/2", 6", 8" and other sizes indicated on drawings. 3. Steel Rigid Furring Channels: ASTM C 645, hat shaped, depth and minimum thickness of base (uncoated) metal as follows: a. Thickness: min. 0.0179 inch, unless otherwise indicated. b. Depth: 7/8 inch. 4. Fasteners for Metal Framing: Provide fasteners of type, material, size, corrosion resistance, holding power, and other properties required to fasten steel framing and furring members securely to substrates involved; complying with the recommendations of gypsum board manufacturers for applications indicated. 5. Delegated Design; Steel framing for Walls and Partitions: Systems to comply with performance requirements and design criteria below: a. Deflection: L/120 b. Load: 7.5 psf. c. Limiting Height: As indicated on drawings. Design to include all framing combinations indicated or implied on the drawings. Include all Composite wall and bracing conditions indicated. Design to be sealed by an engineer licensed to practice in the project jurisdiction. 2.3 INTERIOR GYPSUM BOARD A. General: Complying with ASTM C 36/C 36M or ASTM C 1396/C 1396M, as applicable to type of gypsum board indicated and whichever is more stringent. Provide gypsum board of types indicated in maximum lengths available that will minimize end-to-end butt joints in each area indicated to receive gypsum board application. 1. Widths: Provide gypsum board in widths of 48 inches. 2. Available Manufacturers: Subject to compliance with requirements, manufacturers offering products that may be incorporated into the Work include, but are not limited to, the following: 3. Manufacturers: Subject to compliance with requirements, provide products by one of the following: a. American Gypsum Co. b. BPB America Inc. c. G-P Gypsum. d. Lafarge North America Inc. e. National Gypsum Company. f. PABCO Gypsum. g. Temple. h. USG Corporation. 4. Core: 5/8 inch. 5. Long Edges: Tapered. Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett / 2024008 Hillsborough, NC Orange County Asset Management Services GYPSUM BOARD 09 29 00 - 4 B. Regular Type: 1. Thickness: 5/8 inch. 2. Long Edges: Tapered. C. Type C: 1. Thickness: As required by fire-resistance-rated assembly indicated on Drawings. 2. Long Edges: Tapered D. Type X: 1. Thickness: 5/8 inch. 2. Long Edges: Tapered. 3. Core: 5/8 inch, 4. Long Edges: Tapered 2.4 CEMENT BOARD PANELS A. Cementitious Backer Units: ANSI A118.9. 1. Available Products: Subject to compliance with requirements, products that may be incorporated into the Work include, but are not limited to, the following: 2. Products: Subject to compliance with requirements, provide one of the following: a. Custom Building Products; Wonderboard. b. FinPan, Inc.; Util-A-Crete Concrete Backer Board. c. USG Corporation; DUROCK Cement Board. 3. Thickness: As indicated on Drawings. 2.5 TRIM ACCESSORIES A. Interior Trim: ASTM C 1047. 1. Material: Galvanized or aluminum-coated steel sheet or rolled zinc. 2. Shapes: a. Cornerbead on outside corners. b. L-Bead: L-shaped; exposed long flange receives joint compound. Use L-bead unless otherwise indicated. Provide at all locations where gypsum board abuts dissimilar materials. c. Expansion (control) joint. B. Exterior Trim: ASTM C 1047. 1. Material: Hot-dip galvanized steel sheet, plastic, or rolled zinc. 2. Shapes: a. Cornerbead. 2.6 JOINT TREATMENT MATERIALS A. General: Comply with ASTM C 475/C 475M. B. Joint Tape: 1. Interior Gypsum Wallboard: Paper. 2. Glass-Mat Gypsum Sheathing Board: 10-by-10 glass mesh. 3. Tile Backing Panels: As recommended by panel manufacturer. C. Joint Compound for Interior Gypsum Wallboard (EXCEPT SHOWER ROOMS): For each coat use formulation that is compatible with other compounds applied on previous or for successive coats. 1. Prefilling: At open joints, rounded or beveled panel edges, and damaged surface areas, use setting-type taping compound. 2. Embedding and First Coat: For embedding tape and first coat on joints, fasteners, and trim flanges, use drying-type, all-purpose compound. Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett / 2024008 Hillsborough, NC Orange County Asset Management Services GYPSUM BOARD 09 29 00 - 5 a. Use setting-type compound for installing paper-faced metal trim accessories. 3. Fill Coat: For second coat, use drying-type, all-purpose compound. 4. Finish Coat: For third coat, use drying-type, all-purpose compound. 5. Skim Coat: For final coat of Level 5 finish, use drying-type, all-purpose compound. D. Joint Compound for Shower Room Applications: 1. Shower Room Ceilings: Use setting-type taping compound and setting-type, sandable topping compound. E. Joint Compound for Cementitious Backer Units panels: 1. Cementitious Backer Units: As recommended by backer unit manufacturer. 2.7 AUXILIARY MATERIALS A. General: Provide auxiliary materials that comply with referenced installation standards and manufacturer’s written recommendations. B. Steel Drill Screws: ASTM C 1002, unless otherwise indicated. 1. Use screws complying with ASTM C 954 for fastening panels to steel members from 0.033 to 0.112 inch thick. 2. For fastening cementitious backer units, use screws of type and size recommended by panel manufacturer. C. Acoustical Sealant: As specified in Division 07 Section "Joint Sealants." 1. Acoustical Sealant for Exposed and Concealed Joints: Manufacturer’s standard nonsag, paintable, nonstaining latex sealant complying with ASTM C 834 and the following requirements: a. Product is effective in reducing airborne sound transmission through perimeter joints and openings in building construction as demonstrated by testing representative assemblies according to ASTM E 90. 2. Available Products: Subject to compliance with requirements, acoustical sealants that may be incorporated in the Work include, but are not limited to, the following: a. Acoustical Sealant for Exposed and Concealed Joints: 1) PL Acoustical Sealant; ChemRex, Inc.; Contech Brands. 2) AC-20 FTR Acoustical and Insulation Sealant; Pecora Corp. 3) SHEETROCK Acoustical Sealant; United States Gypsum Co. D. Thermal Insulation and Sound Attenuation Blankets: As specified in Division 07 Section "Thermal Insulation." E. Vapor Retarder: As specified in Division 07 Section "Thermal Insulation." PART 3 - EXECUTION 3.1 EXAMINATION A. Examine areas and substrates, with Installer present, and including welded hollow-metal frames and framing, for compliance with requirements and other conditions affecting performance. B. Examine panels before installation. Reject panels that are wet, moisture damaged, and mold damaged. C. Proceed with installation only after unsatisfactory conditions have been corrected. 3.2 INSTALLING STEEL FRAMING GENERAL A. Steel Framing Installation Standard: Install steel framing to comply with ASTM C 754 and with ASTM C 840 requirements that apply to framing installation. B. Install supplementary framing, blocking, and bracing at terminations in gypsum board assemblies to support fixtures, equipment services, heavy trim, grab bars, toilet accessories, furnishings, or similar Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett / 2024008 Hillsborough, NC Orange County Asset Management Services GYPSUM BOARD 09 29 00 - 6 construction. Comply with details indicated and with recommendations of gypsum board manufacturer or, if none available, with United States Gypsum Co.’s "Gypsum Construction Handbook." C. Do not bridge building control and expansion joints with steel framing or furring members. Independently frame both sides of joints with framing or furring members as indicated. 3.3 INSTALLING STEEL FRAMING FOR SUSPENDED AND FURRED CEILINGS A. Suspend ceiling hangers from building structural members and as follows: 1. Install hangers plumb and free from contact with insulation or other objects within ceiling plenum that are not part of supporting structural or ceiling suspension system. Splay hangers only where required to miss obstructions and offset resulting horizontal forces by bracing, countersplaying, or other equally effective means. 2. Where width of ducts and other construction within ceiling plenum produces hanger spacings that interfere with the location of hangers required to support standard suspension system members, install supplemental suspension members and hangers in form of trapezes or equivalent devices. Size supplemental suspension members and hangers to support ceiling loads within performance limits established by referenced standards. 3. Secure wire hangers by looping and wire-tying, either directly to structures or to inserts, eye screws, or other devices and fasteners that are secure and appropriate for substrate, and in a manner that will not cause them to deteriorate or otherwise fail. 4. Secure flat, angle, and rod hangers to structure, including intermediate framing members, by attaching to inserts, eye screws, or other devices and fasteners that are secure and appropriate for structure as well as for type of hanger involved, and in a manner that will not cause them to deteriorate or otherwise fail. 5. Do not attach hangers to steel roof deck. Attach hangers to structural members. 6. Do not connect or suspend steel framing from ducts, pipes, or conduit. B. Sway-brace suspended steel framing with hangers used for support. C. Install suspended steel framing components in sizes and at spacings indicated, but not less than that required by the referenced steel framing installation standard. 1. Wire Hangers: 48 inches o.c. 2. Carrying Channels (Main Runners): 48 inches o.c. 3. Furring Channels (Furring Members): 16 inches o.c. D. Installation Tolerances: Install steel framing components for suspended ceilings so that cross-furring or grid suspension members are level to within 1/8 inch in 12 feet as measured both lengthwise on each member and transversely between parallel members. E. Wire-tie or clip furring members to main runners and to other structural supports as indicated. 3.4 INSTALLING STEEL FRAMING FOR WALLS AND PARTITIONS A. Install runners (tracks) at floors, ceilings, and structural walls and columns where gypsum board stud assemblies abut other construction. 1. Where studs are installed directly against exterior walls, install asphalt felt strips or foam gaskets between studs and wall. B. Installation Tolerances: Install each steel framing and furring member so that fastening surfaces do not vary more than 1/8 inch from the plane formed by the faces of adjacent framing. C. Extend partition framing full height to structural supports or substrates above suspended ceilings, except where partitions are indicated to terminate at suspended ceilings. Continue framing over frames for doors and openings and frame around ducts penetrating partitions above ceiling to provide support for gypsum board. 1. Cut studs ‰ inch short of full height to provide perimeter relief. 2. For STC-rated and fire-resistance-rated partitions that extend to the underside of floor/roof slabs and decks or other continuous solid structural surfaces to obtain ratings, install framing around structural and other members extending below floor/roof slabs and decks, as needed, to support Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett / 2024008 Hillsborough, NC Orange County Asset Management Services GYPSUM BOARD 09 29 00 - 7 gypsum board closures needed to make partitions continuous from floor to underside of solid structure. D. Install steel studs and furring in sizes and at spacings indicated. 1. Single-Layer Construction: Space studs 16 inches o.c., unless otherwise indicated. 2. Multilayer Construction: Space studs 16 inches o.c., unless otherwise indicated. E. Install steel studs so flanges point in the same direction and leading edge or end of each gypsum board panel can be attached to open (unsupported) edges of stud flanges first. F. Frame door openings to comply with GA-219, and with applicable published recommendations of gypsum board manufacturer, unless otherwise indicated. Attach vertical studs at jambs with screws either directly to frames or to jamb anchor clips on door frames; install runner track section (for cripple studs) at head and secure to jamb studs. 1. Install double 20-gage studs at each jamb, unless otherwise indicated. 2. Install cripple studs at head adjacent to each jamb stud, with a minimum ‰-inch clearance from jamb stud to allow for installation of control joint. G. Frame openings other than door openings to comply with details indicated or, if none indicated, as required for door openings. Install framing below sills of openings to match framing required above door heads. 3.5 APPLYING AND FINISHING PANELS, GENERAL A. Comply with ASTM C 840. B. Install ceiling panels across framing to minimize the number of abutting end joints and to avoid abutting end joints in central area of each ceiling. Stagger abutting end joints of adjacent panels not less than one framing member. C. Install sound-attenuation blankets, where indicated, prior to installing gypsum panels unless blankets are readily installed after panels have been installed on one side. D. Attach gypsum panels to steel studs so leading edge or end of each panel is attached to open (unsupported) edges of stud flanges first. E. Attach gypsum panels to framing provided at openings and cutouts. F. Install panels with face side out. Butt panels together for a light contact at edges and ends with not more than 1/16 inch of open space between panels. Do not force into place. G. Locate edge and end joints over supports, except in ceiling applications where intermediate supports or gypsum board back-blocking is provided behind end joints. Do not place tapered edges against cut edges or ends. Stagger vertical joints on opposite sides of partitions. Do not make joints other than control joints at corners of framed openings. H. Form control and expansion joints with space between edges of adjoining gypsum panels. I. Cover both faces of support framing with gypsum panels in concealed spaces (above ceilings, etc.), except in chases braced internally. 1. Unless concealed application is indicated or required for sound, fire, air, or smoke ratings, coverage may be accomplished with scraps of not less than 8 sq. ft. in area. 2. Fit gypsum panels around ducts, pipes, and conduits. 3. Where partitions intersect structural members projecting below underside of floor/roof slabs and decks, cut gypsum panels to fit profile formed by structural members; allow 1/4- to 3/8-inch- wide joints to install sealant. J. Isolate perimeter of gypsum board applied to non-load-bearing partitions at structural abutments, except floors. Provide 1/4- to 1/2-inch- wide spaces at these locations, and trim edges with edge trim where edges of panels are exposed. Seal joints between edges and abutting structural surfaces with acoustical sealant. K. Attachment to Steel Framing: Attach panels so leading edge or end of each panel is attached to open (unsupported) edges of stud flanges first. L. Space fasteners in gypsum panels according to referenced gypsum board application and finishing standard and manufacturer’s recommendations. 1. Space screws a maximum of 12 inches o.c. for vertical applications. Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett / 2024008 Hillsborough, NC Orange County Asset Management Services GYPSUM BOARD 09 29 00 - 8 3.6 APPLYING INTERIOR GYPSUM BOARD A. Install interior gypsum board in the following locations: 1. Regular Type: As indicated on Drawings. 2. Type X: Install in Shower Rooms. 3. Type C: Where required for specific fire-resistance-rated assembly indicated. B. Single-Layer Application: 1. On ceilings, apply gypsum panels before wall/partition board application to greatest extent possible and at right angles to framing, unless otherwise indicated. 2. On partitions/walls, apply gypsum panels vertically (parallel to framing), unless otherwise indicated or required by fire-resistance-rated assembly, and minimize end joints. a. Stagger abutting end joints not less than one framing member in alternate courses of panels. 3. On Z-furring members, apply gypsum panels vertically (parallel to framing) with no end joints. Locate edge joints over furring members. 4. Fastening Methods: Apply gypsum panels to supports with steel drill screws. 3.7 APPLYING CEMENTITIOUS BACKER PANELS A. Cementitious Backer Units: ANSI A108.11, at locations indicated. 3.8 INSTALLING TRIM ACCESSORIES A. General: For trim with back flanges intended for fasteners, attach to framing with same fasteners used for panels. Otherwise, attach trim according to manufacturer’s written instructions. B. Exterior Trim: Install in the following locations: 1. Cornerbead: Use at outside corners. 3.9 FINISHING GYPSUM BOARD A. General: Treat gypsum board joints, interior angles, edge trim, control joints, penetrations, fastener heads, surface defects, and elsewhere as required to prepare gypsum board surfaces for decoration. Promptly remove residual joint compound from adjacent surfaces. B. Prefill open joints, rounded or beveled edges, and damaged surface areas. C. Apply joint tape over gypsum board joints, except those with trim having flanges not intended for tape. D. Gypsum Board Finish Levels: Finish panels to levels indicated below and according to ASTM C 840: 1. Level 1: Ceiling plenum areas, concealed areas, and where indicated. 2. Level 5: Gypsum board surfaces, unless otherwise indicated a. Primer and its application to surfaces are specified in other Division 09 Sections. 3. Level 5: Provide at all Projection and Magnetic Wall Paint Areas. E. Glass-Mat Gypsum Sheathing Board: Finish according to manufacturer’s written instructions for use as exposed soffit board. F. Cementitious Backer Units: Finish according to manufacturer’s written instructions. G. Use the following joint compound combination as applicable to the finish levels specified: 1. Embedding and First Coat: Ready-mixed, drying-type, all-purpose or taping compound. Fill (Second) Coat: Ready-mixed, drying-type, all-purpose or topping compound. Finish (Third) Coat: Ready-mixed, drying-type, all-purpose or topping compound. H. For Level 4 gypsum board finish, embed tape in joint compound and apply first, fill (second), and finish (third) coats of joint compound over joints, angles, fastener heads, and accessories. Touch up and sand between coats and after last coat as needed to produce a surface free of visual defects and ready for decoration. Install Level 5 finish in Corridors. 1. Where Level 1 gypsum board finish is indicated, embed tape in joint compound. Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett / 2024008 Hillsborough, NC Orange County Asset Management Services GYPSUM BOARD 09 29 00 - 9 3.10 PROTECTION A. Protect installed products from damage from weather, condensation, direct sunlight, construction, and other causes during remainder of the construction period. B. Remove and replace panels that are wet, moisture damaged, and mold damaged. 1. Indications that panels are wet or moisture damaged include, but are not limited to, discoloration, sagging, or irregular shape. 2. Indications that panels are mold damaged include, but are not limited to, fuzzy or splotchy surface contamination and discoloration. END OF SECTION 09 29 00 Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett / 2024008 Hillsborough, NC Orange County Asset Management Services GYPSUM BOARD 09 29 00 - 10 Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett / 2024008 Hillsborough, NC Orange County Asset Management Services ACOUSTICAL TILE CEILINGS 09 51 23 - 1 SECTION 09 51 23 - ACOUSTICAL TILE CEILINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section. 1.2 SUMMARY A. This Section includes acoustical tiles for ceilings and the following: 1. 2x2 Acoustical Tile Lay-in Ceiling 2. Suspended ceiling grid B. Products furnished, but not installed under this Section, include anchors, clips, and other ceiling attachment devices to be cast in concrete at ceilings. C. Related Section: 1. Division 01 Section Allowances for additional quantities 2. Division 01 Section Unit Prices 1.3 DEFINITIONS A. AC: Articulation Class. B. CAC: Ceiling Attenuation Class. C. LR: Light-Reflectance coefficient. D. NRC: Noise Reduction Coefficient. 1.4 SUBMITTALS A. Product Data: For each type of product indicated. B. Coordination Drawings: Reflected ceiling plans, drawn to scale, on which the following items are shown and coordinated with each other, based on input from installers of the items involved: 1. Ceiling suspension system members. 2. Method of attaching hangers to building structure. C. Samples for Initial Selection: For components with factory-applied color finishes. D. Product Test Reports: Based on evaluation of comprehensive tests performed by a qualified testing agency, for each acoustical tile ceiling. E. Maintenance Data: For finishes to include in maintenance manuals. F. Certificates: Submit certificates from manufacturers of acoustical ceiling units and suspension systems attesting that their products comply with specification requirements. 1.5 QUALITY ASSURANCE A. Source Limitations: 1. Acoustical Ceiling Tile: Obtain each type through one source from a single manufacturer. 2. Suspension System: Obtain each type through one source from a single manufacturer. B. Fire-Test-Response Characteristics: Provide acoustical tile ceilings that comply with the following requirements: Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett / 2024008 Hillsborough, NC Orange County Asset Management Services ACOUSTICAL TILE CEILINGS 09 51 23 - 2 1. Surface-Burning Characteristics: Provide acoustical tiles with the following surface-burning characteristics complying with ASTM E 1264 for Class A materials as determined by testing identical products per ASTM E 84: a. Smoke-Developed Index: 450 or less. C. Seismic Standard: Provide acoustical tile ceilings designed and installed to withstand the effects of earthquake motions according to the following: a. CISCA’s Recommendations for Acoustical Ceilings: Comply with CISCA’s "Recommendations for Direct-Hung Acoustical Tile and Lay-in Panel Ceilings--Seismic Zones 0-2." 1.6 DELIVERY, STORAGE, AND HANDLING A. Deliver acoustical tiles, suspension system components, and accessories to Project site in original, unopened packages and store them in a fully enclosed, conditioned space where they will be protected against damage from moisture, humidity, temperature extremes, direct sunlight, surface contamination, and other causes. B. Before installing acoustical tiles, permit them to reach room temperature and a stabilized moisture content. C. Handle acoustical tiles carefully to avoid chipping edges or damaging units in any way. 1.7 PROJECT CONDITIONS A. Environmental Limitations: Do not install acoustical tile ceilings until spaces are enclosed and weatherproof, wet work in spaces is complete and dry, work above ceilings is complete, and ambient temperature and humidity conditions are maintained at the levels indicated for Project when occupied for its intended use. 1. Pressurized Plenums: Operate ventilation system for not less than 48 hours before beginning acoustical tile ceiling installation. 1.8 COORDINATION A. Coordinate layout and installation of acoustical tiles and suspension system with other construction that penetrates ceilings or is supported by them, including light fixtures, HVAC equipment, fire-suppression system, and partition assemblies. 1.9 EXTRA MATERIALS A. Furnish extra materials described below that match products installed and that are packaged with protective covering for storage and identified with labels describing contents. 1. Acoustical Ceiling Units: Full-size tiles equal to 2.0 percent of quantity installed. 2. Suspension System Components: Quantity of each concealed grid and exposed component equal to 2.0 percent of quantity installed. Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett / 2024008 Hillsborough, NC Orange County Asset Management Services ACOUSTICAL TILE CEILINGS 09 51 23 - 3 PART 2 - PRODUCTS 2.1 ACOUSTICAL TILES, GENERAL A. Acoustical Tile Standard: Provide manufacturer’s standard tiles of configuration indicated that comply with ASTM E 1264 classifications as designated by types, patterns, acoustical ratings, and light reflectances, unless otherwise indicated. B. Acoustical Tile Colors and Patterns: Match appearance characteristics indicated for each product type. 1. Where appearance characteristics of acoustical tiles are indicated by referencing pattern designations in ASTM E 1264 and not manufacturers’ proprietary product designations, provide products selected by Architect from each manufacturer’s full range that comply with requirements indicated for type, pattern, color, light reflectance, acoustical performance, edge detail, and size. C. Sound Attenuation Performance: Provide acoustical ceiling units with ratings for ceiling sound transmission class (STC) of range indicated as determined according to AMA 1-II "Ceiling Sound Transmission Test by Two-Room Method" with ceilings continuous at partitions and supported by a metal suspension system of type appropriate for ceiling unit of configuration indicated (concealed for tile, exposed for panels). D. Broad Spectrum Antimicrobial Fungicide and Bactericide Treatment: Provide acoustical tiles treated with manufacturer’s standard antimicrobial formulation that inhibits fungus, mold, mildew, and gram-positive and gram- negative bacteria and showing no mold, mildew, or bacterial growth when tested according to ASTM D 3273 and evaluated according to ASTM D 3274 or ASTM G 21. 2.2 ACOUSTICAL TILES FOR ACOUSTICAL TILE CEILING A. Refer to drawings for locations of ceiling finish. B. Basis-of-Design Product (as listed below): Subject to compliance with requirements, provide Armstrong product as specified or a comparable product by one of the following: 1. Armstrong World Industries, Inc. 2. CertainTeed 3. USG Interiors, Inc C. Armstrong 704 Cortega to Match Existing Ceiling Tile. 1. Color: White. 2. LR: Not less than 0.80. 3. NRC: Not less than 0.50. 4. CAC: Not less than 33. 5. Edge/Joint Detail: Square Edge 6. Thickness: min. 15/16 inch. 7. Modular Size: 24 by 24 inches. 8. 15 Year No-Sag Resistance: Provide 15 year no-sag warranty. 2.3 METAL SUSPENSION SYSTEMS, GENERAL A. Metal Suspension System Standard: Provide manufacturer’s standard metal suspension systems of types, structural classifications, and finishes indicated that comply with applicable requirements in ASTM C 635. B. Finishes and Colors, General: Comply with NAAMM’s "Metal Finishes Manual for Architectural and Metal Products" for recommendations for applying and designating finishes. Provide manufacturer’s standard factory- applied finish for type of system indicated. C. Wire Hangers, Braces, and Ties: Provide wires complying with the following requirements: 1. Galvanized, Carbon-Steel Wire: ASTM A 641/A 641M, Class 1 zinc coating, soft temper. Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett / 2024008 Hillsborough, NC Orange County Asset Management Services ACOUSTICAL TILE CEILINGS 09 51 23 - 4 2. Size: Select wire diameter so its stress at 3 times hanger design load (ASTM C 635, Table 1, "Direct Hung" ) will be less than yield stress of wire, but provide not less than 12 gauge diameter wire. D. Hanger Rods: Mild steel, zinc coated or protected with rust-inhibitive paint. E. Angle Hangers: Angles with legs not less than 7/8 inch wide; formed with 0.04-inch- thick, galvanized steel sheet complying with ASTM A 653/A 653M, G90 coating designation; with bolted connections and 5/16-inch- diameter bolts. F. Seismic Struts: Manufacturer’s standard compression struts designed to accommodate lateral forces. G. Seismic Clips: Manufacturer’s standard seismic clips designed and spaced to secure acoustical tiles in-place. 2.4 METAL SUSPENSION SYSTEM FOR ACOUSTICAL TILE CEILING A. Available Products: Subject to compliance with requirements, products that may be incorporated into the Work include, but are not limited to, the following: B. Products: Subject to compliance with requirements, provide one of the following: 1. Armstrong World Industries, Inc. 2. USG Interiors, Inc. 3. Chicago Metallic 4. CertainTeed C. Intermediate Duty, Direct-Hung, Double-Web, Suspension System: Main and cross runners roll formed from and capped with cold-rolled steel sheet, prepainted, electrolytically zinc coated, or hot-dip galvanized according to ASTM A 653/A 653M, G30 coating designation. 1. Structural Classification: Intermediate-duty system. 2. Access: Upward and end or side pivoted, with initial access openings of size indicated below and located throughout ceiling within each module formed by main and cross runners, with additional access available by progressively removing remaining acoustical tiles. D. Indirect-Hung, Fire-Rated Suspension System: Main and cross runners roll formed from cold-rolled steel sheet with 15/16 wide exposed faces on structural members, prepainted, electrolytically zinc coated, or hot-dip galvanized according to ASTM A 653/A 653M, G30 coating designation. 1. Structural Classification: Intermediate-duty system. 2. Carrying Channels: Cold-rolled steel, 0.059850-inch- minimum base (uncoated) metal thickness, not less than 3/16-inch- wide flanges by 1-1/2-inch- deep steel channels, 475 lb/1000 feet, with rust-inhibitive paint finish. 3. Access: Where access is indicated, provide special cross runners or split splines to allow for removal of acoustical units in indicated access areas. Identify access tile with manufacturer’s standard unobtrusive markers for each access unit. 2.5 METAL EDGE MOLDINGS AND TRIM A. Products: Subject to compliance with requirements, provide one of the following: 1. Armstrong World Industries, Inc. 2. Chicago Metallic Corporation 3. USG Interiors, Inc. B. Roll-Formed, Sheet-Metal Edge Moldings and Trim: Type and profile indicated or, if not indicated, manufacturer’s standard moldings for edges and penetrations that comply with seismic design requirements; formed from sheet metal of same material, finish, and color as that used for exposed flanges of suspension system runners. 1. Provide manufacturer’s standard edge moldings that fit acoustical tile edge details and suspension systems indicated and that match width and configuration of exposed runners, unless otherwise indicated. 2. For circular penetrations of ceiling, provide edge moldings fabricated to diameter required to fit penetration exactly. Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett / 2024008 Hillsborough, NC Orange County Asset Management Services ACOUSTICAL TILE CEILINGS 09 51 23 - 5 2.6 ACOUSTICAL SEALANT A. Available Products: Subject to compliance with requirements, products that may be incorporated into the Work include, but are not limited to, the following: B. Products: Subject to compliance with requirements, provide one of the following: 1. Acoustical Sealant for Exposed and Concealed Joints: a. Pecora Corporation; AC-20 FTR Acoustical and Insulation Sealant. b. USG Corporation; SHEETROCK Acoustical Sealant. 2. Acoustical Sealant for Concealed Joints: a. OSI Sealants, Inc.; Pro-Series SC-175 Rubber Base Sound Sealant. b. Pecora Corporation; BA-98. c. Tremco, Inc.; Tremco Acoustical Sealant. C. Acoustical Sealant for Exposed and Concealed Joints: Manufacturer’s standard nonsag, paintable, nonstaining latex sealant, with a VOC content of 250 g/L or less when calculated according to 40 CFR 59, Subpart D (EPA Method 24), complying with ASTM C 834 and effective in reducing airborne sound transmission through perimeter joints and openings in building construction as demonstrated by testing representative assemblies according to ASTM E 90. D. Acoustical Sealant for Concealed Joints: Manufacturer’s standard nondrying, nonhardening, nonskinning, nonstaining, gunnable, synthetic-rubber sealant, with a VOC content of 250 g/L or less when calculated according to 40 CFR 59, Subpart D (EPA Method 24), recommended for sealing interior concealed joints to reduce airborne sound transmission. 2.7 MISCELLANEOUS MATERIALS A. Hold-Down Clips for Non-Fire-Rated Ceilings: For interior ceilings composed of lay-in panels weighting less than 1 lb per sq.ft., provide hold-down clips spaced 2’-0" o.c. on all cross tees. PART 3 - EXECUTION 3.1 EXAMINATION A. Examine substrates, areas, and conditions, including structural framing and substrates to which acoustical tile ceilings attach or abut, with Installer present, for compliance with requirements specified in this and other Sections that affect ceiling installation and anchorage and with requirements for installation tolerances and other conditions affecting performance of acoustical tile ceilings. 1. Proceed with installation only after unsatisfactory conditions have been corrected. 3.2 PREPARATION A. Testing Substrates: Before installing adhesively applied tiles on wet-placed substrates such as cast-in-place concrete or plaster, test and verify that moisture level is below tile manufacturer’s recommended limits. B. Measure each ceiling area and establish layout of acoustical tiles to balance border widths at opposite edges of each ceiling. Avoid using less-than-half-width tiles at borders, and comply with layout shown on reflected ceiling plans. 3.3 INSTALLATION, SUSPENDED ACOUSTICAL TILE CEILINGS A. General: Install acoustical tile ceilings to comply with ASTM C 636 and seismic design requirements indicated, per manufacturer’s written instructions and CISCA’s "Ceiling Systems Handbook." Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett / 2024008 Hillsborough, NC Orange County Asset Management Services ACOUSTICAL TILE CEILINGS 09 51 23 - 6 B. Suspend ceiling hangers from building’s structural members and as follows: 1. Install hangers plumb and free from contact with insulation or other objects within ceiling plenum that are not part of supporting structure or of ceiling suspension system. 2. Splay hangers only where required to miss obstructions; offset resulting horizontal forces by bracing, countersplaying, or other equally effective means. 3. Splay hangers only where required and, if permitted with fire-resistance-rated ceilings, to miss obstructions; offset resulting horizontal forces by bracing, countersplaying, or other equally effective means. 4. Where width of ducts and other construction within ceiling plenum produces hanger spacings that interfere with location of hangers at spacings required to support standard suspension system members, install supplemental suspension members and hangers in form of trapezes or equivalent devices. 5. Secure wire hangers to ceiling suspension members and to supports above with a minimum of three tight turns. Connect hangers directly either to structures or to inserts, eye screws, or other devices that are secure and appropriate for substrate and that will not deteriorate or otherwise fail due to age, corrosion, or elevated temperatures. 6. Do not support ceilings directly from permanent metal forms or floor deck. Fasten hangers to cast-in-place hanger inserts, postinstalled mechanical or adhesive anchors, or power-actuated fasteners that extend through forms into concrete. 7. When steel framing does not permit installation of hanger wires at spacing required, install carrying channels or other supplemental support for attachment of hanger wires. 8. Do not attach hangers to steel deck tabs. 9. Do not attach hangers to steel roof deck. Attach hangers to structural members. 10. Space hangers not more than 48 inches o.c. along each member supported directly from hangers, unless otherwise indicated; provide hangers not more than 8 inches from ends of each member. 11. Size supplemental suspension members and hangers to support ceiling loads within performance limits established by referenced standards and publications. C. Secure bracing wires to ceiling suspension members and to supports with a minimum of four tight turns. Suspend bracing from building’s structural members as required for hangers, without attaching to permanent metal forms, steel deck, or steel deck tabs. Fasten bracing wires into concrete with cast-in-place or postinstalled anchors. D. Install edge moldings and trim of type indicated at perimeter of acoustical tile ceiling area and where necessary to conceal edges of acoustical tiles. 1. Apply acoustical sealant in a continuous ribbon concealed on back of vertical legs of moldings before they are installed. 2. Screw attach moldings to substrate at intervals not more than 16 inches o.c. and not more than 3 inches from ends, leveling with ceiling suspension system to a tolerance of 1/8 inch in 12 feet. Miter corners accurately and connect securely. 3. Do not use exposed fasteners, including pop rivets, on moldings and trim. E. Install suspension system runners so they are square and securely interlocked with one another. Remove and replace dented, bent, or kinked members. F. Arrange directionally patterned acoustical tiles as follows: 1. Install tiles with pattern running in one direction parallel to long axis of space. 3.4 CLEANING A. Clean exposed surfaces of acoustical tile ceilings, including trim and edge moldings. Comply with manufacturer’s written instructions for cleaning and touchup of minor finish damage. Remove and replace tiles and other ceiling components that cannot be successfully cleaned and repaired to permanently eliminate evidence of damage. END OF SECTION 09 51 23 Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett / 2024008 Hillsborough, NC Orange County Asset Management Services ACOUSTICAL TILE CEILINGS 09 51 23 - 7 Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett / 2024008 Hillsborough, NC Orange County Asset Management Services ACOUSTICAL TILE CEILINGS 09 51 23 - 8 Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A TABLE OF CONTENTS DIVISION 23 - HEATING, VENTILATING, AND AIR-CONDITIONING (HVAC) 23 05 12 ELECTRICAL WORK 1 23 05 29 HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT 5 23 05 53 IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT 3 23 05 93 TESTING, ADJUSTING, AND BALANCING FOR HVAC 7 23 07 13 DUCT INSULATION 5 23 31 00 HVAC DUCTS AND CASINGS 7 23 33 00 AIR DUCT ACCESSORIES 5 23 37 00 AIR OUTLETS AND INLETS 3 DIVISION 26 - ELECTRICAL 26 05 05 ELECTRICAL DEMOLITION 2 26 05 19 POWER CONDUCTORS AND CABLES 6 26 05 29 HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS 2 26 05 33.13 CONDUIT FOR ELECTRICAL SYSTEMS 6 26 05 33.16 BOXES AND CABINETS 3 26 05 53 IDENTIFICATION FOR ELECTRICAL SYSTEMS 3 26 09 23 LIGHTING CONTROL DEVICES 5 26 27 26 WIRING DEVICES 4 26 51 00 INTERIOR AND EXTERIOR LIGHTING 6 10/03/2025 10/03/2025 Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services ELECTRICAL WORK 23 05 12 - 1 SECTION 23 05 12 ELECTRICAL WORK PART 1 GENERAL 1.01 DIVISION OF WORK A This Contractor shall be responsible for the final electrical and the entire control connections and wiring to all equipment installed as part of his contract. B Contractor shall review the electrical plans,where applicable,to establish points of connection and the extent of his electrical work to be provided in his contract. C Unless otherwise noted,this Contractor shall wire from his equipment to disconnect switches,junction boxes,or panelboard circuit breakers as provided by the Electrical Contractor or as required by the existing conditions. D All power and control wiring shall be in conduits. Refer to electrical specifications for conduit and conduit fittings. E All electrical work shall be performed by a licensed electrician. F All electrical work shall be in accordance with the State Building Code and all its supplements,the latest edition of the National Electrical Code and the electrical specifications. PART 2 PRODUCT 2.01 GENERAL REQUIREMENTS A All motor starters,disconnects,switches,relays,conduits,conductors,etc.that are required for a complete electrical power and/or control system shall conform to the requirements set forth by NEC. B Refer to the plans for the type,size and electrical characteristics of the starters,disconnects,switches,relays, conductor and conduits. C All conductors and conduits shall be sized as noted on the plans or As required per NEC. D All individual motor starters for mechanical equipment (i.e.,fans,pumps,etc.)shall be furnished and installed under Division 23. E All relays,actuators,timers,seven-day clocks,alternators,pressure,vacuum,float,flow,pneumatic-electric, and electric-pneumatic switches,aquastats,freezestats,line and low voltage thermostats,thermals,remote selector switches,remote push-button stations,emergency break-glass stations,interlocking,disconnect switches beyond termination point,and other appurtenances associated with equipment under Division 23 shall be furnished,installed and wired under Division 23. PART 3 EXECUTION 3.01 GENERAL REQUIREMENTS A All motor starters,disconnects,and switches shall be installed on or as close to the equipment they are serving as possible,or where shown on the plans. B Electrical connection to equipment subject to vibration which develops objectionable noises shall be made from the conduit system with short lengths of flexible "Liquid-Tite"conduit.Connection to other equipment shall be made with rigid conduit. C Conduits shall be run in a concealed space such as wall cavities,ceiling cavities,etc.except in the mechanical rooms where conduit may be run exposed. END OF SECTION 23 05 12 23 05 12 Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT 23 05 29 - 1 SECTION 23 05 29 HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT PART 1 GENERAL 1.01 SECTION INCLUDES A Support and attachment components. 1.02 REFERENCE STANDARDS A ASTM A123/A123M -Standard Specification for Zinc (Hot-Dip Galvanized)Coatings on Iron and Steel Products;2024. B ASTM A153/A153M -Standard Specification for Zinc Coating (Hot-Dip)on Iron and Steel Hardware; 2023. C ASTM A181/A181M -Standard Specification for Carbon Steel Forgings,for General-Purpose Piping;2023. D ASTM A36/A36M -Standard Specification for Carbon Structural Steel;2019. E ASTM A47/A47M -Standard Specification for Ferritic Malleable Iron Castings;1999,with Editorial Revision (2022). F ASTM A283/A283M -Standard Specification for Low and Intermediate Tensile Strength Carbon Steel Plates;2024. G ASTM A395/A395M -Standard Specification for Ferritic Ductile Iron Pressure-Retaining Castings for Use at Elevated Temperatures;1999 (Reapproved 2022). H ASTM A653/A653M -Standard Specification for Steel Sheet,Zinc-Coated (Galvanized)or Zinc-Iron Alloy- Coated (Galvannealed)by the Hot-Dip Process;2023. I ASTM B633 -Standard Specification for Electrodeposited Coatings of Zinc on Iron and Steel;2023. J ASTM E84 -Standard Test Method for Surface Burning Characteristics of Building Materials;2018b. K FM (AG)-FM Approval Guide;Current Edition. L MFMA-4 -Metal Framing Standards Publication;2004. M MSS SP-58 -Pipe Hangers and Supports -Materials,Design,Manufacture,Selection,Application,and Installation;2025. N UL (DIR)-Online Certifications Directory;Current Edition. O UL 723 -Standard for Test for Surface Burning Characteristics of Building Materials;Current Edition, Including All Revisions. 1.03 ADMINISTRATIVE REQUIREMENTS A Coordination: 1.Coordinate sizes and arrangement of supports and bases with the actual equipment and components to be installed. 2.Coordinate the work with other trades to provide additional framing and materials required for installation. 3.Coordinate compatibility of support and attachment components with mounting surfaces at the installed locations. 4.Coordinate the arrangement of supports with ductwork,piping,equipment and other potential conflicts installed under other sections or by others. 5.Notify Engineer of any conflicts with or deviations from Contract Documents.Obtain direction before proceeding with work. B Sequencing: 1.Do not install products on or provide attachment to concrete surfaces until concrete has fully cured. 1.04 SUBMITTALS A Product Data: Provide manufacturer's standard catalog pages and data sheets for ​channel (strut)framing systems and thermal insulated pipe supports​. B Shop Drawings: Include details for fabricated hangers and supports where materials or methods other than those indicated are proposed for substitution. Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT 23 05 29 - 2 1.Application of protective inserts,saddles,and shields at pipe hangers for each type of insulation and hanger. C Evaluation Reports: For products specified as requiring evaluation and recognition by ICC Evaluation Service,LLC (ICC-ES),provide current ICC-ES evaluation reports upon request. D Manufacturer's Instructions: Indicate application conditions and limitations of use stipulated by product testing agency. Include instructions for storage,handling,protection,examination,preparation,and installation of product. 1.05 QUALITY ASSURANCE A Comply with applicable building code. B Review the Structural Drawings for limitations as to type of hangers to be used on various structural members. C Installer Qualifications for Powder-Actuated Fasteners (when specified): Certified by fastener system manufacturer with current operator's license. D Product Listing Organization Qualifications: An organization recognized by OSHA as a Nationally Recognized Testing Laboratory (NRTL)and acceptable to authorities having jurisdiction. 1.06 DELIVERY,STORAGE,AND HANDLING A Receive,inspect,handle,and store products in accordance with manufacturer's instructions. PART 2 PRODUCTS 2.01 MANUFACTURERS A B-Line B Elgen Manufacturing Company,Inc C Thomas &Betts Corporation D Unistrut,a brand of Atkore International Inc 2.02 SUPPORT AND ATTACHMENT COMPONENTS A General Requirements: 1.Provide all required hangers,supports,anchors,fasteners,fittings,accessories,and hardware as necessary for the complete installation of plumbing work. 2.Provide products listed,classified,and labeled as suitable for the purpose intended,where applicable. 3.Where support and attachment component types and sizes are not indicated,select in accordance with manufacturer's application criteria as required for the load to be supported​with a minimum safety factor of 2​.Include consideration for vibration,equipment operation,and shock loads where applicable. 4.Do not use wire,chain,perforated pipe strap,or wood for permanent supports unless specifically indicated or permitted. 5.Steel Components: Use corrosion resistant materials suitable for the environment where installed. a.Indoor Dry Locations: Use zinc-plated steel or approved equivalent unless otherwise indicated. b.Outdoor and Damp or Wet Indoor Locations: Use ​galvanized steel or stainless steel​unless otherwise indicated. c.Zinc-Plated Steel: Electroplated in accordance with ASTM B633. d.Galvanized Steel: Hot-dip galvanized after fabrication in accordance with ASTM A123/A123M or ASTM A153/A153M. B Prefabricated Trapeze-Framed Metal Strut Systems: 1.MFMA-4 compliant,pre-fabricated,MSS SP-58 type 59 continuous-slot metal strut channel with associated tracks,fittings,and related accessories. 2.Strut Channel or Bracket Material: a.Indoor Dry Locations:Use ​​zinc-plated steel or galvanized steel​​. b.Outdoor and Damp or Wet Indoor Locations: Use galvanized steel. 3.Accessories: Provide ​bracket covers,clamps,conduit clamps,fire-retarding brackets,j-hooks, protectors,and vibration dampeners​. Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT 23 05 29 - 3 C Strut Channels: 1.ASTM A653/A653M​galvanized steel bracket with clamps for surface mounting of piping or equipment support. 2.Channel or Bracket Kits: Include rods,brackets,end-fixed fittings,covers,clips,and other related hardware required to complete sectional trapeze section for piping or other support. D Channel Nuts: 1.Provide ​carbon steel​channel nut with ​galvanized steel,stainless steel,or zinc​finish and ​regular​spring. E Hanger Rods: 1.Minimum Size,Unless Otherwise Indicated or Required: a.Equipment Supports: 1/2 inch diameter. b.Piping up to 1 inch: 1/4 inch diameter. c.Trapeze Support for Multiple Pipes: 3/8 inch diameter. F Steel Cable: 1.Manufacturers: a.Ductmate Industries,Inc,a DMI Company;Clutcher Cable Hanging System​ b.Elgen Manufacturing Company,Inc c.Gripple d.Source Limitations: Furnish hardware,fittings,and accessories from single manufacturer. G Cable Hanging System Kits: 1.Manufacturers: a.B-Line,a brand of Eaton Corporation b.Ductmate Industries,Inc c.Gripple,Inc​ d.Source Limitations: Furnish hardware,fittings,and accessories from single manufacturer. 2.Provide cable-wire in bulk or precut lengths with respective cable hangers as required to hold minimum weight of ​240 lb​. H Thermal Insulated Pipe Supports: 1.Manufacturers: a.Buckaroos,Inc​ 2.General Requirements: a.Insulated pipe supports to be provided at hanger,support,and guide locations on pipe requiring insulation or additional support. b.Surface Burning Characteristics: Flame spread index/smoke developed index of 5/30,maximum, when tested in accordance with ASTM E84 or UL 723. c.Pipe supports to be provided for nominally sized,1/2 to 30 inch iron pipes. d.Insulation inserts to consist of ​​calcium silicate​​insulation surrounded by a ​​360 degree,​​​​galvanized steel ​​jacketing. 3.Pipe insulation protection shields to be provided at the hanger points and guide locations on pipes requiring insulation as indicated on drawings. I Pipe Supports: 1.Material: ASTM A395/A395M ductile iron,ASTM A36/A36M carbon steel,ASTM A47/A47M malleable iron,ASTM A181/A181M forged steel,or ASTM A283/A283M steel. 2.Liquid Temperatures Up To 122 degrees F: a.Overhead Support: MSS SP-58 Types 1,3 through 12. b.Support From Below: MSS SP-58 Types 35 through 38. 3.Operating Temperatures from ​122 to 446 degrees F​: a.Overhead Support: MSS SP-58 Type 1 or 3 through 12,with appropriate saddle of MSS SP-58 Type 40 for insulated pipe. Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT 23 05 29 - 4 b.Roller Support: MSS SP-58 Types 41 or 43 through 46,with appropriate saddle of MSS SP-58 Type 39 for insulated pipe. c.Sliding Support: MSS SP-58 Types 35 through 38. J Pipe Stanchions: 1.Material: Malleable iron,ASTM A47/A47M;or carbon steel,ASTM A36/A36M. 2.Provide coated or plated saddles to isolate steel hangers from dissimilar metal tube or pipe. 3.For pipe runs,use stanchions of same type and material where vertical adjustment is required for stationary pipe. K Beam Clamps: 1.MSS SP-58 types 19 through 23,25 or 27 through 30 based on required load. 2.Beam C-Clamp: MSS SP-58 type 23,​malleable iron and steel​with ​zinc​finish. 3.Small or Junior Beam Clamp: MSS SP-58 type 19,malleable iron with ​zinc​finish. For inverted usage provide manufacturer listed size(s). 4.Wide Mouth Beam Clamp: MSS SP-58 type 19,malleable iron with zinc or galvanized finish. 5.Centerload Beam Clamp with Extension Piece: MSS SP-58 type 30,malleable iron with galvanized finish. 6.FM (AG)and UL (DIR)Approved Beam Clamp: MSS SP-58 type 19,​plated finish​, 7.Provide clamps with hardened steel cup-point set screws and lock-nuts for anchoring in place. 8.Material: ASTM A395/A395M ductile iron,ASTM A36/A36M carbon steel,ASTM A47/A47M malleable iron,ASTM A181/A181M forged steel,or ASTM A283/A283M steel. L Riser Clamps: 1.For insulated pipe runs,provide two bolt-type clamps designed for installation under insulation. 2.MSS SP-58 type 1 or 8, 3.Medium Split Horizontal Pipe Clamp:MSS SP-58​​type 4 4.Copper Tube Pipe Clamp:MSS SP-58 type 8,copper-plated. 5.UL (DIR)listed: Pipe sizes 1/2 to 8 inch. M U-Bolts: 1.MSS SP-58 Type 24,​zinc-coated carbon steel​u-bolt for pipe support or anchoring. N Insulation Clamps: 1.Two bolt-type clamps designed for installation under insulation. 2.Material:​Carbon steel​with ​galvanized steel or zinc​finish. O Pipe Hangers: 1.Split Ring Hangers: a.Provide ​hinged split ring and yoke roller​hanger with ​zinc or copper plated​finish. b.Material: ASTM A47/A47M malleable iron or ASTM A36/A36M carbon steel. c.Provide hanger rod and nuts of the same type and material for a given pipe run. d.Provide coated or plated hangers to isolate steel hangers from dissimilar metal tube or pipe. 2.Clevis Hangers,Adjustable: a.Copper Tube:MSS SP-58 Type 1,copper-plated. b.Standard-Duty:MSS SP-58​Type 1 c.UL (DIR)listed: Pipe sizes 2-1/2 to 8 inch. d.FM (AG)listed: Pipe sizes 2-1/2 to 8 inch. P Intermediate Pipe Guides: 1.Pipe Diameter 6 inch and Smaller: Provide minimum clearance of 0.16 inch. 2.Pipe Sizes 8 inch: 0.625 inch U-bolt with double nuts providing minimum clearance of 0.28 inch. 3.Pipe Size 10 inch: 0.75 inch U-bolt. 4.Pipe Sizes 12 to 16 inch: 0.875 inch U-bolt. 5.Pipe Sizes 18 to 30 inch: 1 inch U-bolt. 6.Use pipe clamps with oversize pipe sleeve that provides clearance around pipe. Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT 23 05 29 - 5 Q Pipe Alignment Guides: 1.Pipe Sizes 8 inch and Smaller: Spider or sleeve type. 2.Pipe Sizes 10 inch and Larger: Roller type. R Dielectric Barriers: Provide between metallic supports and metallic piping and associated items of dissimilar type;acceptable dielectric barriers include rubber or plastic sheets or coatings attached securely to pipe or item. S Anchors and Fasteners: 1.Unless otherwise indicated and where not otherwise restricted,use the anchor and fastener types indicated for the specified applications. 2.Concrete: Use preset concrete inserts,expansion anchors,or screw anchors. 3.Solid or Grout-Filled Masonry: Use expansion anchors or screw anchors. 4.Hollow Stud Walls: Use toggle bolts. 5.Steel: Use beam-ceiling clamps,beam clamps,machine bolts,or welded threaded studs. 6.Sheet Metal: Use sheet metal screws. 7.Preset Concrete Inserts: Continuous metal channel (strut)and spot inserts specifically designed to be cast in concrete ceilings,walls,and floors. a.Comply with MFMA-4. b.Channel Material: Use galvanized steel. c.Manufacturer: Same as manufacturer of metal channel (strut)framing system. PART 3 EXECUTION 3.01 INSTALLATION A Install products in accordance with manufacturer's instructions. B Install anchors and fasteners in accordance with ICC Evaluation Services,LLC (ICC-ES)evaluation report conditions of use where applicable. C Provide independent support from building structure. Do not provide support from piping,ductwork, conduit,or other systems. D Unless specifically indicated or approved by Architect,do not provide support from suspended ceiling support system or ceiling grid. E Unless specifically indicated or approved by Architect,do not provide support from roof deck. F Do not penetrate or otherwise notch or cut structural members without approval of Structural Engineer. G Provide thermal insulated pipe supports complete with hangers and accessories. Install thermal insulated pipe supports during the installation of the piping system. H Equipment Support and Attachment: 1.Use metal fabricated supports or supports assembled from metal channel (strut)to support equipment as required. 2.Use metal channel (strut)secured to studs to support equipment surface-mounted on hollow stud walls when wall strength is not sufficient to resist pull-out. 3.Use metal channel (strut)to support surface-mounted equipment in wet or damp locations to provide space between equipment and mounting surface. 4.Securely fasten floor-mounted equipment. Do not install equipment such that it relies on its own weight for support. I Preset Concrete Inserts: Use manufacturer-provided closure strips to inhibit concrete seepage during concrete pour. J Secure fasteners according to manufacturer's recommended torque settings. K Remove temporary supports. END OF SECTION 23 05 29 Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT 23 05 53 - 1 SECTION 23 05 53 IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT PART 1 GENERAL 1.01 SECTION INCLUDES A Nameplates. B Tags. C Stencils. D Pipe markers. 1.02 REFERENCE STANDARDS A ASTM D709 -Standard Specification for Laminated Thermosetting Materials;2017. 1.03 SUBMITTALS A List: Submit list of wording,symbols,letter size,and color coding for mechanical identification. B Chart and Schedule: Submit valve chart and schedule,including valve tag number,location,function,and valve manufacturer's name and model number. C Product Data: Provide manufacturers catalog literature for each product required. D Manufacturer's Installation Instructions: Indicate special procedures,and installation. PART 2 PRODUCTS 2.01 IDENTIFICATION APPLICATIONS A Air Handling Units: Nameplates. B Air Terminal Units: Nameplates. C Automatic Controls: Tags. Key to control schematic. D Control Panels: Nameplates. E Dampers: Ceiling tacks,where located above lay-in ceiling. F Ductwork: Stencilled painting. G Heat Transfer Equipment: Nameplates. H Instrumentation: Tags. I Major Control Components: Nameplates. J Piping: ​Stencilled painting​. K Relays: Tags. L Small-sized Equipment: Tags. M Thermostats: Nameplates. 2.02 NAMEPLATES A Manufacturers: 1.Advanced Graphic Engraving,LLC 2.Brimar Industries,Inc 3.Craftmark Pipe Markers 4.Kolbi Pipe Marker Co 5.Seton Identification Products,a Tricor Direct Company 6.Or Approved Equal B Letter Color: Black. C Letter Height: 1/4 inch. D Background Color: White. E Phenolic: Conform to ASTM D709. 2.03 TAGS A Manufacturers: 1.Advanced Graphic Engraving 2.Brady Corporation 3.Brimar Industries,Inc 4.Craftmark Pipe Markers Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT 23 05 53 - 2 5.Kolbi Pipe Marker Co 6.Seton Identification Products,a Tricor Company 7.Or Approved Equal B Metal Tags: Aluminum with stamped letters;tag size minimum 1-1/2 inch diameter with smooth edges.Use metal tags in return air plenums. C Valve Tag Chart: Typewritten letter size list in anodized aluminum frame. 2.04 STENCILS A Manufacturers: 1.Brady Corporation 2.Craftmark Pipe Markers 3.Kolbi Pipe Marker Co 4.Seton Identification Products,a Tricor Company 5.Or Approved Equal B Stencils: With clean cut symbols and letters of following size: 1.3/4 to 1-1/4 inch Outside Diameter of Insulation or Pipe: 8 inch long color field,1/2 inch high letters. 2.1-1/2 to 2 inch Outside Diameter of Insulation or Pipe: 8 inch long color field,3/4 inch high letters. 3.2-1/2 to 6 inch Outside Diameter of Insulation or Pipe: 12 inch long color field,1-1/4 inch high letters. 4.8 to 10 inch Outside Diameter of Insulation or Pipe: 24 inch long color field,2-1/2 inch high letters. 5.Over 10 inch Outside Diameter of Insulation or Pipe: 32 inch long color field,3-1/2 inch high letters. 6.Ductwork and Equipment: 2-1/2 inch high letters. 7.Stencil Paint: Semi-gloss enamel,colors conforming to ASME A13.1. 2.05 CEILING GRID LABELS A Label each device or valve above the ceiling and label the ceiling grid below each.Indicate the type of device or valve and its associated service (e.g.“Shutoff Valve –HW”,“VAV-21”). B Provide custom printed labels for each device,either vinyl or polypropylene,suitable for indoor /outdoor applications.Use portable printer equal to Brady HandiMark Portable Industrial Labeling System. C Labels shall be no more than 1-inch in height.Lettering shall be minimum 18-point font.Lettering shall be black on white tape. D Provide a list of devices and valves labeled with the identical information in the O&M Manuals. E Submit samples of markings on three different devices for approval of the Owner and Engineer. F Ceiling grid markers shall be the color listed below: 1.Electrical -Pull Box/Disconnects/Future -Neon Red 2.Mechanical Equipment/Fan/Dampers,etc.-Neon Yellow PART 3 EXECUTION 3.01 PREPARATION A Degrease and clean surfaces to receive adhesive for identification materials. 3.02 INSTALLATION A Install nameplates with corrosive-resistant mechanical fasteners,or adhesive. Apply with sufficient adhesive to ensure permanent adhesion and seal with clear lacquer. B Install tags with corrosion resistant chain. C All piping and duct shall be labeled at least once in EVERY room.Piping and ductwork shall be labeled every 15 ft and at every change of direction. D Install ductwork with stencilled painting. Identify with air handling unit identification number and area served. Identify service (supply,return,exhaust,outside air,etc.) Locate identification at air handling unit, at each side of penetration of structure or enclosure,and at each obstruction. E Provide ceiling grid labels to locate valves or dampers above lay-in panel ceilings. Locate in corner of panel closest to equipment. F Identify thermostats or temperature sensors relating to air handling units or valves with labels. G Identify valves in main and branch piping with valve labels. Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT 23 05 53 - 3 H Tag automatic controls,instruments,and relays.Key to control schematic. I Identify pumps with plastic nameplates indicating pump number,system served,GPM,and feet of head. J Provide ceiling track markers to locate valves or dampers above T-bar type panel ceilings.Locate in corner of panel closest to equipment.Markers shall be installed prior to request for above ceiling inspection. 3.03 SCHEDULE A Standard Color Identification for Mechanical Piping (all labels shall be provided with flow arrows): 1.Hot Water Supply/Return HWS/HWR Black Lettering 2.Condensate Drain COND Black Lettering B Standard Color Identification for Ductwork (all labels shall be provided with flow arrows): 1.Supply Air SUPPLY Black Lettering 2.Return RETURN Black Lettering 3.Outside Air OUTSIDE AIR Black Lettering 4.General Exhaust EXHAUST Black Lettering END OF SECTION 23 05 53 Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services TESTING,ADJUSTING,AND BALANCING FOR HVAC 23 05 93 - 1 SECTION 23 05 93 TESTING,ADJUSTING,AND BALANCING FOR HVAC PART 1 GENERAL 1.01 SECTION INCLUDES A Testing,adjustment,and balancing of air systems. B Measurement of final operating condition of HVAC systems. 1.02 REFERENCE STANDARDS A AABC (NSTSB)-AABC National Standards for Total System Balance,7th Edition;2016. B ASHRAE Std 111 -Measurement,Testing,Adjusting,and Balancing of Building HVAC Systems;2024. C NEBB (TAB)-Procedural Standards for Testing Adjusting and Balancing of Environmental Systems;2015, with Errata (2017). 1.03 SUBMITTALS A TAB Plan: Submit a written plan indicating the testing,adjusting,and balancing standard to be followed and the specific approach for each system and component. 1.Submit to Architect. B Include at least the following in the plan: 1.Indicate standard to be followed (AABC or NEBB) 2.List of all ​airflow​ and efficiency measurements to be performed and a description of specific test procedures,parameters,formulas to be used. 3.Copy of field checkout sheets and logs to be used,listing each piece of equipment to be tested, adjusted and balanced with the data cells to be gathered for each. 4.Identification and types of measurement instruments to be used and their most recent calibration date. 5.Discussion of what notations and markings will be made on the duct and piping drawings during the process. 6.Final test report forms to be used. 7.Detailed step-by-step procedures for TAB work for each system and issue,including: a.Terminal flow calibration (for each terminal type). b.Diffuser proportioning. c.Branch/submain proportioning. d.Total flow calculations. e.Rechecking. f.Diversity issues. 8.Details of how TOTAL flow will be determined;for example: a.Air: Sum of terminal flows via control system calibrated readings or via hood readings of all terminals,supply (SA)and return air (RA)pitot traverse,SA or RA flow stations. 9.Specific procedures that will ensure that systems are operating at the lowest possible pressures and methods to verify this. 10.Methods for making coil or other system plant capacity measurements,if specified. 11.Time schedule for TAB work to be done in phases (by floor,etc.). 12.Description of TAB work for areas to be built out later,if any. 13.Procedures for formal deficiency reports,including scope,frequency and distribution. C Control System Coordination Reports: Communicate in writing to the controls installer all setpoint and parameter changes made or problems and discrepancies identified during TAB that affect,or could affect, the control system setup and operation. D Final Report: Indicate deficiencies in systems that would prevent proper testing,adjusting,and balancing of systems and equipment to achieve specified performance. 1.Revise TAB plan to reflect actual procedures and submit as part of final report. 2.Submit draft copies of report for review prior to final acceptance of Project. Provide final copies for Architect and for inclusion in operating and maintenance manuals. Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services TESTING,ADJUSTING,AND BALANCING FOR HVAC 23 05 93 - 2 3.Provide final reports in ​soft cover,letter size,3-ring​binder manuals,complete with index page and indexing tabs,with cover identification at front and side.Include set of reduced drawings with air outlets and equipment identified to correspond with data sheets,and indicating thermostat locations. The Final Report shall be placed in and become a part of the Maintenance and Operations Manuals (4 copies). 4.Include actual instrument list,with manufacturer name,serial number,and date of calibration. 5.Form of Test Reports: Where the TAB standard being followed recommends a report format use that; otherwise,follow ASHRAE Std 111. 6.Units of Measure: Report data in I-P (inch-pound)units only. 7.Include the following on the title page of each report: a.Name of Testing,Adjusting,and Balancing Agency. b.Address of Testing,Adjusting,and Balancing Agency. c.Telephone number of Testing,Adjusting,and Balancing Agency. d.Also include a certification sheet containing the seal and name,address,telephone number,and signature of the Certified Test and Balance Engineer.Include in this division a listing of the instruments used for the procedures along with proof of calibration. E Project Record Documents: Record actual locations of flow measuring stations and balancing valves and rough setting. 1.04 QUALITY ASSURANCE A The TAB agency shall be a subcontractor of the General Contractor (or Construction Manager)and shall report directly to and be paid by the General Contractor. B The TAB agency shall be either a certified member of AABC or NEBB to perform TAB service for HVAC, water balancing and vibrations and sound testing of equipment.The certification shall be maintained for the entire duration of duties specified herein. C Any agency that has been the subject of disciplinary action by either the AABC or NEBB within the five years preceding Contract Award shall not be eligible to perform any work related to the TAB.All work performed in this Section and in other related Sections by the TAB agency shall be considered invalid if the TAB agency loses its certification prior to Contract completion,and the successor agency’s review shows unsatisfactory work performed by the predecessor agency. D TAB Specialist:The TAB specialist shall be either a member of AABC or an experienced technician of the Agency certified by NEBB.The certification shall be maintained for the entire duration of duties specified herein.If,for any reason,the Specialist loses subject certification during this period,the General Contractor shall immediately notify the Engineer and submit another TAB Specialist for approval.Any individual that has been the subject of disciplinary action by either the AABC or NEBB within the five years preceding Contract Award shall not be eligible to perform any duties related to the HVAC systems,including TAB.All work specified in this Section and in other related Sections performed by the TAB specialist shall be considered invalid if the TAB Specialist loses its certification prior to Contract completion and must be performed by an approved successor. E TAB Specialist shall be identified by the General Contractor within 60 days after the notice to proceed.The TAB specialist will be coordinating,scheduling and reporting all TAB work and related activities and will provide necessary information as required by the Resident Engineer.The responsibilities would specifically include: 1.Shall directly supervise all TAB work. 2.Shall sign the TAB reports that bear the seal of the TAB standard.The reports shall be accompanied by report forms and schematic drawings required by the TAB standard,AABC,TABB or NEBB. 3.Would follow all TAB work through its satisfactory completion. 4.Shall provide final markings of settings of all HVAC adjustment devices. 5.Permanently mark location of duct test ports. Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services TESTING,ADJUSTING,AND BALANCING FOR HVAC 23 05 93 - 3 6.Shall document critical paths from the fan or pump.These critical paths are ones in which are 100% open from the fan or pump to the terminal device.This will show the least amount of restriction is being imposed on the system by the TAB firm. F All TAB technicians performing actual TAB work shall be experienced and must have done satisfactory work on a minimum of 3 projects comparable in size and complexity to this project.Qualifications must be certified by the TAB agency in writing.The lead technician shall be certified by AABC or NEBB 1.05 WARRANTY A National Project Performance Guarantee: Provide a guarantee AABC or NEBB will assist in completing requirements of the Contract Documents if TAB firm fails to comply with the Contract Documents. Guarantee includes the following provisions: 1.The certified TAB firm has tested and balanced systems according to the Contract Documents. 2.Systems are balanced to optimum performance capabilities within design and installation limits. 3.Warranty Period: Five (5)years. PART 2 PRODUCTS 2.01 PLUGS A Provide plastic plugs to seal holes drilled in ductwork for test purposes. 2.02 INSULATION REPAIR MATERIAL A Refer to individual insulation sections for repair of insulation removed or damaged during TAB work. PART 3 EXECUTION 3.01 GENERAL REQUIREMENTS A Perform total system balance in accordance with one of the following: 1.AABC (NSTSB),AABC National Standards for Total System Balance. B Begin work after completion of systems to be tested,adjusted,or balanced and complete work prior to Substantial Completion of the project. C Where HVAC systems and/or components interface with life safety systems,including fire and smoke detection,alarm,and control,coordinate scheduling and testing and inspection procedures with the authorities having jurisdiction. D TAB Agency Qualifications: 1.Company specializing in the testing,adjusting,and balancing of systems specified in this section. 2.Having minimum of three years documented experience. 3.Certified by one of the following: a.AABC,Associated Air Balance Council: www.aabc.com/#sle;upon completion submit AABC National Performance Guaranty. b.NEBB,National Environmental Balancing Bureau: www.nebb.org/#sle. E TAB Supervisor and Technician Qualifications: Certified by same organization as TAB agency. F For each air handling system,provide a graphical static pressure profile indicating the pressure drop across each component of the air handling unit (filter,coils,dampers,wheel,etc). 3.02 EXAMINATION A Verify that systems are complete and operable before commencing work. Ensure the following conditions: 1.Systems are started and operating in a safe and normal condition. 2.Temperature control systems are installed complete and operable. 3.Proper thermal overload protection is in place for electrical equipment. 4.Final filters are clean and in place. If required,install temporary media in addition to final filters. 5.Duct systems are clean of debris. 6.Fans are rotating correctly. 7.Fire and volume dampers are in place and open. 8.Air coil fins are cleaned and combed. 9.Access doors are closed and duct end caps are in place. 10.Air outlets are installed and connected. Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services TESTING,ADJUSTING,AND BALANCING FOR HVAC 23 05 93 - 4 11.Duct system leakage is minimized. B Submit field reports. Report defects and deficiencies that will or could prevent proper system balance. C Beginning of work means acceptance of existing conditions. 3.03 PREPARATION A Hold a pre-balancing meeting at least one week prior to starting TAB work. 1.Require attendance by all installers whose work will be tested,adjusted,or balanced. B Obtain design drawings and specifications and become thoroughly acquainted with the design intent. C Obtain copies of approved shop drawings of all air handling equipment,outlets (supply,return,and exhaust) and temperature control diagrams. D Compare design to installed equipment and field installations. E Walk the system to determine variations of installation from design. F Check filters for cleanliness. G Lubricate all motors and bearings. 3.04 ADJUSTMENT TOLERANCES A Air Systems Tolerances Systems -Air Tolerances of Drawing Design Remarks Air Handling Units,Fans (Supply,Return,Exhaust)-5%to +10%Systems with Filters must be tested at dirty conditions Outdoor Air 100%to 110%To obtain this accuracy requires ductwork be traversed Terminal Units +/-5% Calibrate all boxes at minimum of two points.Single point calibration is not acceptable. Diffusers and Grilles +/-10%If design is less than 100 CFM, tolerance can be +/-10 CFM Pressurized Rooms -Positive Supply +100-105% Exhaust or Return 100- 95% Room offset tolerance to design 100% to +110% Pressurized rooms -Negative Supply 95%to 100% Exhaust or Return 100% to 105% Room offset tolerance to design 100% to 105% 3.05 RECORDING AND ADJUSTING A Field Logs: Maintain written logs including: 1.Running log of events and issues. 2.Discrepancies,deficient or uncompleted work by others. 3.Contract interpretation requests. 4.Lists of completed tests. B Ensure recorded data represents actual measured or observed conditions. C Use only those instruments which have the maximum field measuring accuracy and are best suited to the function being measured. D Apply instrument as recommended by the manufacturer. E When averaging values,take a sufficient quantity of readings that will result in a repeatability error of less than 5 percent.When measuring a single point,repeat readings until 2 consecutive identical values are obtained. F Permanently mark settings of valves,dampers,and other adjustment devices allowing settings to be restored. Set and lock memory stops. Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services TESTING,ADJUSTING,AND BALANCING FOR HVAC 23 05 93 - 5 G Mark on drawings the locations where traverse and other critical measurements were taken and cross reference the location in the final report. H After adjustment,take measurements to verify balance has not been disrupted or that such disruption has been rectified. I Leave systems in proper working order,replacing belt guards,closing access doors,closing doors to electrical switch boxes,and restoring thermostats to specified settings. J Seal ducts and piping,and test for and repair leaks. K Seal insulation to re-establish integrity of vapor barrier. L Retest,adjust,and balance systems subsequent to significant system modifications and resubmit test results. 3.06 AIR SYSTEM PROCEDURE A Adjust air handling and distribution systems to provide required or design supply,return,and exhaust air quantities at site altitude. B Test,adjust,and balance the air systems before the hydronic systems. C Make air quantity measurements in ducts by Pitot tube traverse of entire cross sectional area of duct. D Measure air quantities at air inlets and outlets. E Adjust distribution system to obtain uniform space temperatures free from objectionable drafts and noise. This includes adjusting the deflection of all diffuser and grilles. F Use volume control devices to regulate air quantities only to extent that adjustments do not create objectionable air motion or sound levels.Effect volume control by duct internal devices such as dampers and splitters. G Vary total system air quantities by adjustment of fan speeds. Provide drive changes required. Vary branch air quantities by damper regulation. H Measure static air pressure conditions on air supply units,including filter and coil pressure drops,and total pressure across the fan.Make allowances for 50 percent loading of filters. 1.Artificially load filters by partially blanking to produce static pressure air drop of filter manufacturer's recommeneded "dirty"pressure drop. I Coordinate with Controls Contractor on adjusting static pressure setpoints of VAV systems and differential pressure setpoints of VFD controlled pumps. J Adjust outside air automatic dampers,outside air,return air,and exhaust dampers for design conditions. K Measure temperature conditions across outside air,return air,and exhaust dampers to check leakage. L Where modulating dampers are provided,take measurements and balance at extreme conditions.Balance variable volume systems at maximum air flow rate,full cooling,and at minimum air flow rate,full heating. M For variable air volume system powered units set volume controller to air flow setting indicated. Confirm connections properly made and confirm proper operation for automatic variable air volume temperature control. N Single-duct,dual-duct,and fan-powered VAV boxes shall be calibrated using a multi-point calibration approach.Single-point calibration will not be acceptable. 1.Check and readjust ATU flow rates as necessary to meet design criteria.Balance air distribution from ATU on full cooling maximum scheduled cubic meters per minute (cubic feet per minute).Reset room thermostats and check ATU operation from maximum to minimum cooling,to the heating mode,and back to cooling.Record and report the heating coil leaving air temperature when the ATU is in the maximum heating mode. O The TAB report shall indicate the critical VAV box and how the static pressure set point was estalished. 3.07 CRITICAL FLOW PATH A Provide a documented critical path for all fluid flows.There shall be at least one terminal device that can be traced back to the fan or pump where there is no damper or valves that are less than 100%open. 3.08 DEMONSTRATION A Training Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services TESTING,ADJUSTING,AND BALANCING FOR HVAC 23 05 93 - 6 1.Train the Owner's maintenance personnel on troubleshooting procedures and testing,adjusting,and balancing procedures.Provide four (4)hours on site training.Review with the Owner's personnel the information contained in the Operating and Maintenance Data specified in Division 1 and Section 23 01 00. 2.Schedule training with the Owner through the Engineer with at least 7 days prior notice. 3.09 SCOPE A Test,adjust,and balance the following: 1.Air Coils. 2.Fans. 3.Air Filters. 4.Air Terminal Units. 5.Air Inlets and Outlets. B This Section does NOT include: 1.Testing boilers and pressure vessels for compliance with safety codes. 2.Specifications for materials for patching mechanical systems. 3.Specifications for materials and installation of adjusting and balancing;refer to the respective system sections for materials and installation requirements. 4.Requirements and procedures for piping and ductwork systems leakage tests. 3.10 MINIMUM DATA TO BE REPORTED A Electric Motors: 1.Manufacturer. 2.Model/Frame. 3.HP/BHP. 4.Phase,voltage,amperage;nameplate,actual,no load. 5.RPM. 6.Service factor. 7.Starter size,rating,heater elements. 8.Sheave Make/Size/Bore. B V-Belt Drives: 1.Identification/location. 2.Required driven RPM. 3.Driven sheave,diameter and RPM. 4.Belt,size and quantity. 5.Motor sheave diameter and RPM. 6.Center to center distance,maximum,minimum,and actual. C Heating Coils: 1.Identification/number. 2.Location. 3.Manufacturer. 4.Air flow,design and actual. 5.Water flow,design and actual. 6.Water pressure drop,design and actual. 7.Entering water temperature,design and actual. 8.Leaving water temperature,design and actual. 9.Entering air temperature,design and actual. 10.Leaving air temperature,design and actual. 11.Air pressure drop,design and actual. D Air Moving Equipment: 1.Location. Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services TESTING,ADJUSTING,AND BALANCING FOR HVAC 23 05 93 - 7 2.Manufacturer. 3.Model number. 4.Air flow,specified and actual. 5.Return air flow,specified and actual. 6.Outside air flow,specified and actual. 7.Total static pressure (total external),specified and actual. 8.Inlet pressure. 9.Discharge pressure. 10.Fan RPM. E Exhaust Fans: 1.Location. 2.Manufacturer. 3.Model number. 4.Air flow,specified and actual. 5.Total static pressure (total external),specified and actual. 6.Inlet pressure. 7.Discharge pressure. 8.Fan RPM. F Duct Traverses: 1.System zone/branch. 2.Duct size. 3.Design air flow. 4.Test velocity. 5.Test air flow. 6.Duct static pressure. 7.Air temperature. G Terminal Unit Data: 1.Manufacturer. 2.Type,constant,variable,single,dual duct. 3.Identification/number. 4.Location. 5.Model number. 6.Size. 7.Minimum design air flow. 8.Maximum design air flow. 9.Maximum actual air flow. 10.Inlet static pressure. H Air Distribution Tests: 1.Air terminal number. 2.Room number/location. 3.Terminal type. 4.Terminal size. 5.Design air flow. 6.Test (final)air flow. 7.Percent of design air flow. END OF SECTION 23 05 93 Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services DUCT INSULATION 23 07 13 - 1 SECTION 23 07 13 DUCT INSULATION PART 1 GENERAL 1.01 SECTION INCLUDES A Duct insulation. B Jacketing and accessories. 1.02 REFERENCE STANDARDS A ASTM B209/B209M -Standard Specification for Aluminum and Aluminum-Alloy Sheet and Plate;2021a. B ASTM C518 -Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus;2021. C ASTM C553 -Standard Specification for Mineral Fiber Blanket Thermal Insulation for Commercial and Industrial Applications;2024. D ASTM C612 -Standard Specification for Mineral Fiber Block and Board Thermal Insulation;2014 (Reapproved 2019). E ASTM E84 -Standard Test Method for Surface Burning Characteristics of Building Materials;2018b. F ASTM E96/E96M -Standard Test Methods for Gravimetric Determination of Water Vapor Transmission Rate of Materials;2024a. G UL 723 -Standard for Test for Surface Burning Characteristics of Building Materials;Current Edition, Including All Revisions. 1.03 SUBMITTALS A Product Data:Provide product description,thermal characteristics,list of materials and thickness for each service,and locations.Include the following information: 1.Schedule indicating insulation type,thickness,and location for each service 2.Density 3.Compressive Strength 4."k"value at 75 deg F 5.Nominal "R"value 6.Flame spread rating B Manufacturer's Instructions: Indicate installation procedures necessary to ensure acceptable workmanship and that installation standards will be achieved. 1.04 QUALITY ASSURANCE A Manufacturer Qualifications: Company specializing in manufacturing products of the type specified in this section with not less than three years of documented experience. B Applicator Qualifications: Company specializing in performing the type of work specified in this section​, documented experience​​and approved by manufacturer​. C Before installing insulation,build mockups for each type of insulation and finish listed below to demonstrate quality of insulation application and finishes. Build mockups in the location indicated or,if not indicated,as directed by Owner. Use materials indicated for the completed Work. Mockups shall include piping insulation,ductwork insulation and equipment insulation. D All the ductwork and piping in pump rooms,mechanical rooms and equipment rooms including areas without ceilings is to be considered as exposed piping or ductwork.This also includes penthouses,interstitial spaces,and crawl spaces,where applicable. 1.05 DELIVERY,STORAGE,AND HANDLING A Accept materials on site in original factory packaging,labelled with manufacturer's identification,including product density and thickness. B Protect insulation from weather and construction traffic,dirt,water,chemical,and mechanical damage,by storing in original wrapping. Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services DUCT INSULATION 23 07 13 - 2 1.06 FIELD CONDITIONS A Maintain ambient temperatures and conditions required by manufacturers of adhesives,mastics,and insulation cements. B Maintain temperature during and after installation for minimum period of 24 hours. C Insulation shall not be installed until all testing and inspection of pipe,duct,vessel,etc.has been completed and approved by Engineer/Owner’s representative. PART 2 PRODUCTS 2.01 REGULATORY REQUIREMENTS A Surface Burning Characteristics: Flame spread index/Smoke developed index of 25/50,maximum,when tested in accordance with ASTM E84,UL 723,ASTM E84,or UL 723.These ratings must be as tested on composite of insulation,jacket or facing,and adhesive.Components such as adhesives,mastics,and cements must meet the same individual ratings as minimum requirements. 2.02 GLASS FIBER,FLEXIBLE A Manufacturer: 1.CertainTeed Corporation​​ 2.Johns Manville​​ 3.Knauf Insulation​​ 4.Owens Corning Corporation​​ 5.Or Approved Equal B Insulation: ASTM C553;flexible,noncombustible blanket. 1.K value: 0.36 at 75 degrees F,when tested in accordance with ASTM C518. 2.Maximum Service Temperature: 1,200 degrees F. 3.Maximum Water Vapor Absorption: 5.0 percent by weight. C Vapor Barrier Jacket: 1.Kraft paper with glass fiber yarn and bonded to aluminized film. 2.Moisture Vapor Permeability: 0.02 perm inch,when tested in accordance with ASTM E96/E96M. 3.Secure with pressure-sensitive tape. D Vapor Barrier Tape: 1.Kraft paper reinforced with glass fiber yarn and bonded to aluminized film,with pressure-sensitive rubber-based adhesive. E Indoor Vapor Barrier Mastic: 1.Manufacturers: a.Childers CP-35 b.Hardcast Seal-Tack AF F Tie Wire: Annealed steel,16 gauge,0.0508 inch diameter. 2.03 GLASS FIBER,RIGID A Manufacturer: 1.CertainTeed Corporation 2.Johns Manville​​ 3.Knauf Insulation​​ 4.Owens Corning Corporation​​ 5.Or Approved Equal B Insulation: ASTM C612;rigid,noncombustible. 1.K Value: 0.24 at 75 degrees F,when tested in accordance with ASTM C518. 2.Maximum Service Temperature: 450 degrees F. 3.Maximum Water Vapor Absorption: 5.0 percent. 4.Maximum Density: 8.0 pcf. C Vapor Barrier Jacket: 1.Kraft paper with glass fiber yarn and bonded to aluminized film. Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services DUCT INSULATION 23 07 13 - 3 2.Moisture Vapor Permeability: 0.02 perm inch,when tested in accordance with ASTM E96/E96M. 3.Secure with pressure-sensitive tape. D Vapor Barrier Tape: 1.Manufacturers: a.3M b.Polyguard c.Shurtape 2.Kraft paper reinforced with glass fiber yarn and bonded to aluminized film,with pressure-sensitive rubber-based adhesive. E Protective Coating: 1.Manufacturers: a.Design Polymerics;DP 2510 Water Based,Low VOC,Duct Liner Protective Coating​: F Indoor Vapor Barrier Finish: 1.Cloth: Untreated;9 oz/sq yd weight,glass fabric. 2.Vinyl emulsion type acrylic,compatible with insulation,​white​color. 2.04 POLYISOCYANURATE INSULATION BOARD A Manufacturer: 1.Dyplast 2.Rmax 3.Johns Manville 4.Or Approved Equal B Insulation: 1.Flat Foam Insulation with Heavy Duty Fiber-Reinforced Facers:closed-cell polyisocyanurate foam core laminated to extra durable heavy duty fiber-reinforced facers on both sides;conforming to ASTM C 1289,Type II,Class 2. 2.Blowing Agent:Zero ODP,3rd generation. 3.Thickness 2.00 inch,R Value 11.4,flute spanability 4-3/8 inches 4.25/450 flame/smoke spread rating C Vapor Barrier Jacket: 1.Asphalt Bitumen:ASTM D 312,Type III,or Type IV. D Vapor Barrier Tape: 1.Kraft paper reinforced with glass fiber yarn and bonded to aluminized film,with pressure sensitive rubber based adhesive. 2.05 JACKETING AND ACCESSORIES A Canvas Jacket: UL listed 6 oz/sq yd plain weave cotton fabric treated with dilute fire-retardant lagging adhesive. 1.Lagging Adhesive: a.Manufacturers: 1)Design Polymerics;DP 3050 Water Based,Zero VOC,Premium Quality,Lagging Adhesive,and Vapor Retarder 2)Childers CP-35 b.Compatible with insulation. B Mineral Fiber (Outdoor)Jacket: Asphalt impregnated and coated sheet,50 lb/square. C Aluminum Jacket: 1.Comply with ASTM B209/B209M,Temper H14,minimum thickness of 0.016 inch with factory- applied polyethylene and kraft paper moisture barrier on the inside surface. 2.Thickness: 0.016 inch sheet. 3.Finish: ​Embossed​. 4.Joining: Longitudinal slip joints and 2 inch laps. Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services DUCT INSULATION 23 07 13 - 4 5.Fittings: 0.016 inch thick die-shaped fitting covers with factory-attached protective liner. 6.Metal Jacket Bands: 3/8 inch wide;0.015 inch thick aluminum. PART 3 EXECUTION 3.01 EXAMINATION A Test ductwork for design pressure prior to applying insulation materials. B Verify that surfaces are clean,foreign material removed,and dry. 3.02 INSTALLATION A Install in accordance with manufacturer's instructions. B Insulate all supply diffusers and ducted return grilles with 2"R6 Duct Wrap.Cut diffusers so there is a folder 2"lap on all four sides.Take with FSK tape where insulated flex meets duct insulation so there are no raw edges of fiberglass. C Install multiple layers of insulation with longitudinal and end seams staggered. D Install insulation with least number of joints practical. E Insulated Ducts Conveying Air Below Ambient Temperature: 1.Insulation on all pipes or ducts conveying air or liquids below the ambient temperature is required to have a continuous vapor barrier.On all insulation with a vapor barrier,seal the joints,duct wrap seams, vapor retarder (ASJ)film seams and penetrations in insulation at hangers,supports,anchors,and other projections with a vapor-barrier coating/mastic as specified in the individual insulation sections. 2.For insulation application where vapor barriers are indicated,extend insulation on anchor legs from point of attachment to supported item to point of attachment to structure.Taper and seal ends at attachment to structure with vapor-barrier coating/mastic. 3.Install insert materials and install insulation to tightly join the insert.Seal insulation to insulation inserts with adhesive or sealing compound recommended by insulation material manufacturer. 4.Cover inserts with jacket material matching adjacent pipe insulation.Install shields over jacket, arranged to protect jacket from tear or puncture by hanger,support,and shield. 5.Continue insulation through walls,sleeves,hangers,and other duct penetrations. F Ducts Exposed in Mechanical Equipment Rooms or Finished Spaces​​: Provide rigid fiberglass board insulation and finish with ​canvas jacket sized for finish painting​. G Exterior Applications: Provide rigid polyisocyanurate board insulation with vapor barrier jacket. Provide rigid polyiso board insulation and cover with ​with calked aluminum jacket with seams located on bottom side of horizontal duct section​. H Duct Wrap Insulation Application: 1.Secure insulation with vapor barrier with wires and seal jacket joints with vapor barrier adhesive or tape to match jacket. 2.Install without sag on underside of duct. Use adhesive or mechanical fasteners where necessary to prevent sagging. Lift duct off trapeze hangers and insert spacers.Spacers shall be heavy density insulation board material.Refer to MICA 8th edition Plate 3-640. 3.Seal vapor barrier penetrations by mechanical fasteners with vapor barrier adhesive. 4.Stop and point insulation around access doors and damper operators to allow operation without disturbing wrapping. 3.03 SCHEDULES A All supply,outside air,and return air ductwork shall be completely insulated,unless otherwise noted on the plans.Insulation shall completely cover flexible connections.Insulation shall be minimum 2.5 inch thick or the thickness required to meet the R-values below. B All insulation within the building envelope,except in the attic (where applicable),shall have a minimum R- value of 6.0 based on installed thickness.Any insulation wrap or board installed outside the building envelope or in an attic,shall have a minimum R-value of 8.0 based on installed thickness. C All exhaust duct associated with any unit having energy recovery (enthlpay wheel,enthalpy plate,run around loop,etc.)shall be insulated to R6.0 inside the building and R8.0 outside the building. Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services DUCT INSULATION 23 07 13 - 5 D Exhaust and Relief Ducts Within 10 ft of Exterior Openings or Building Envelope Penetrations:minimum R- value of 6.0 based on installed thickness. END OF SECTION 23 07 13 Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services HVAC DUCTS AND CASINGS 23 31 00 - 1 SECTION 23 31 00 HVAC DUCTS AND CASINGS PART 1 GENERAL 1.01 SECTION INCLUDES A Metal ducts. B Flexible ducts. 1.02 REFERENCE STANDARDS A ASHRAE (FUND)-ASHRAE Handbook -Fundamentals;Most Recent Edition Cited by Referring Code or Reference Standard. B ASTM A36/A36M -Standard Specification for Carbon Structural Steel;2019. C ASTM A653/A653M -Standard Specification for Steel Sheet,Zinc-Coated (Galvanized)or Zinc-Iron Alloy- Coated (Galvannealed)by the Hot-Dip Process;2023. D ASTM E84 -Standard Test Method for Surface Burning Characteristics of Building Materials;2018b. E NFPA 90A -Standard for the Installation of Air-Conditioning and Ventilating Systems;2024. F SMACNA (DCS)-HVAC Duct Construction Standards Metal and Flexible;2020. G SMACNA (LEAK)-HVAC Air Duct Leakage Test Manual;2012. H UL 181 -Standard for Factory-Made Air Ducts and Air Connectors;current edition,including all revisions. 1.03 SUBMITTALS A Product Data: Provide data for duct materials and duct connections. B Shop Drawings: Indicate duct fittings,particulars such as gages,sizes,welds,and configuration prior to start of work for ​all​systems. 1.Clearly indicate which fittings shall be used on the project:elbows,wyes,takeoffs,transitions,offsets, etc. C Test Reports: Indicate pressure tests performed.Include date,section tested,test pressure,and leakage rate per appropriate seal class,following SMACNA (LEAK). 1.04 QUALITY ASSURANCE A Manufacturer Qualifications: Company specializing in manufacturing the type of products specified in this section,with minimum three years of documented experience,and approved by manufacturer. B Galvanizing thickness and country of origin must be clearly stenciled on each duct section.At the discretion of the Engineer,sheet metal gauges and reinforcing may be randomly checked to verify all duct construction is in compliance. C Ductwork and fittings must have a computer generated label affixed to each section detailing the duct dimensions,sheet metal gauge,intermediate and joint reinforcement size,and the transverse connector brand and classification. 1.05 FIELD CONDITIONS A Do not install duct sealants when temperatures are less than those recommended by sealant manufacturers. B Maintain temperatures within acceptable range during and after installation of duct sealants. C If ductwork is stored on site,elevate duct above floors and maintain protection on ends. PART 2 PRODUCTS 2.01 GENERAL REQUIREMENTS A Provide​​​​ductwork,fittings,hangers,supports,and appurtenances in accordance with ​NFPA 90A and SMACNA (DCS)​guidelines unless stated otherwise​​. B Duct Sealing and Leakage in accordance with Static Pressure Class: 1.Low Pressure Service: Up to 2 in-wc: a.Seal: Class C,apply to seal off transverse joints. b.Leakage: 1)Rectangular:Class 16 2)Round:Class 8 2.Medium Pressure Service:4 in-wc and above Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services HVAC DUCTS AND CASINGS 23 31 00 - 2 a.Seal:Class A,apply sealing of transverse joints,longitudinal seams,and duct wall penetrations. b.Leakage: 1)Rectangular:Class 4 2)Round:Class 2 C Duct Fabrication Requirements: 1.Duct and Fitting Fabrication and Support: SMACNA (DCS)including specifics for continuously welded round and oval duct fittings. 2.Use reinforced and sealed sheet-metal materials at recommended gauges for indicated operating pressures or pressure class. 3.Construct tees,bends,and elbows with radius of not less than 1-1/2 times width of duct on centerline. Where not possible and where rectangular elbows must be used,provide airfoil turning vanes of perforated metal with glass fiber insulation. 4.Provide turning vanes of perforated metal with glass fiber insulation when acoustical lining is indicated. 5.Increase duct sizes gradually,not exceeding 15 degrees divergence wherever possible;maximum 30 degrees divergence upstream of equipment and 45 degrees convergence downstream. 6.Provide turning vanes of perforated metal with glass fiber insulation when an acoustical lining is required. 7.Where ducts are connected to exterior wall louvers and duct outlet is smaller than louver frame, provide blank-out panels sealing louver area around duct.Use same material as duct,painted black on exterior side;seal to louver frame and duct. D Duct transverse joints and reinforcement materials,including angle ring flanges and stiffeners,shall be of the same material as the duct. E Low Pressure Supply: 2 inch w.g.pressure class,galvanized steel. F Medium and High Pressure Supply: 6 inch w.g.pressure class,galvanized steel. G Return and Relief: -2 inch w.g.pressure class,galvanized steel. H General Exhaust: -2 inch w.g.pressure class,galvanized steel. I Transfer Air and Sound Boots: ​​1 inch w.g.​​pressure class​​​​. 2.02 MATERIALS A Galvanized Steel for Ducts: Hot-dipped galvanized steel sheet,ASTM A653/A653M FS Type B,with ​​G90/Z275​​coating. B "Paint Grip"Finish or Mill Phosphatized Steel (Exposed Ductwork): 1.Galvanized G90 steel shall be put through a phosphate bath and have a layer of Chromate applied and dried leaving it ready to accept paint.This shall be done at the mill.The process produces a dull gray colored finish. C Joint Sealers and Sealants: Non-hardening,water resistant,mildew and mold resistant. 1.Manufacturers: a.Childers b.Ductmate c.Durodyne d.Foster e.Hardcast f.McGill Airseal g.Sheet Metal Connectors,Inc. h.Or Approved Equal 2.Flexible,water-based,adhesive sealant designed for use in all pressure duct systems. After curing,it shall be resistant to ultraviolet light and shall prevent the entry of water,air,and moisture into the duct system. Sealer shall be UL 723 and UL 181B-M listed and meet NFPA requirements for Class 1 ductwork.VOC shall be <75 g/l. Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services HVAC DUCTS AND CASINGS 23 31 00 - 3 3.Neoprene gasket must be closed cell rubber based sealing tape and must pass UL 94 HF-1. 4.Butyl rubber gasket which complies with UL 723,Mil-C 18969B and TTS-S-001657.This material,in addition to the above,shall not contain vegetable oils,fish oils,or any other type vehicle that will support fungal and/or bacterial growth. 5.Surface Burning Characteristics: Flame spread index of zero and smoke developed index of zero, when tested in accordance with ASTM E84. D Hanger Rod: ASTM A36/A36M;steel,galvanized;threaded both ends,threaded one end,or continuously threaded. E Cable Suspension System: 1.Suspension system shall be Gripple Hang-Fast as manufactured and supplied by Gripple,Inc.,or Ductmate "Clutcher"cable hanging system. 2.Suspension system shall be load rated and verified by SMACNA Testing and Research Institute to be in compliance with SMACNA Standards. 3.All suspension systems shall used galvanized hardware. 2.03 DUCTWORK FABRICATION A Fabricate and support in accordance with SMACNA (DCS)and as indicated. 1.Internal tie rods or bracing are not allowed for ductwork 36"and below.Tie rods shall be 1/2",3/4", 1",1-1/4"or 1-1/2"galvanized rods with bolt assembly consisting of rubber washer and friction anchored threaded insert similar to Ductmate Easyrod or PPI Condu-Lock. 2.Internal tie rods are not allowed for ductwork in chase and other non-accessible locations. B Where the size for a duct segment is not indicated,the duct segment size shall be equal to the largest duct segment to which it is connected.Transition to smaller size shall occur on the side of the fitting where smaller size is indicated. C No variation of duct configuration or size permitted except by written permission. Size round duct installed in place of rectangular ducts in accordance with ASHRAE (FUND)Handbook -Fundamentals. D Construct T's,bends,and elbows with radius of not less than 1-1/2 times width of duct on centerline. Where not possible and where rectangular elbows must be used,provide air foil turning vanes of perforated metal with glass fiber insulation. E Increase duct sizes gradually,not exceeding 15 degrees divergence wherever possible;maximum 30 degrees divergence upstream of equipment and 45 degrees convergence downstream. F Fabricate continuously welded round and oval duct fittings in accordance with SMACNA (DCS). G Where ducts are connected to exterior wall louvers and duct outlet is smaller than louver frame,provide blank-out panels sealing louver area around duct. Use same material as duct,painted black on exterior side; seal to louver frame and duct. 2.04 HANGERS AND SUPPORTS A Refer to the Structural Drawings and Details for the limitations and applications of each type of hanger and weight when attaching to bar joists,trusses,or other building Structural elements.The Contractor shall be responsible for providing additional miscellaneous steel,unistrut,and other components to span multiple joists as required by the Structural Drawings to distribute concentrated loads. B Unless otherwise indicated,use straps or Z bar hangers with 3/8”rods to support rectangular ducts 48”wide and smaller and trapeze hangers with rods or angles to support rectangular ducts over 48”wide. 1.Use trapeze hangers to support externally insulated ductwork with weight bearing inserts. C For round ducts 24"diameter or smaller,use single hanger. 1.Cable Suspension System may be used up to 16"diameter 2.Round Duct Strap Bracket by Ductmate Industries may be used up to 24"diameter. D For round ducts over 24"diameter,use 2 hangers with half round trapeze. E For round ducts over 25”diameter or larger,use 2 minimum 3/8”rods with trapeze. F The following upper attachments,upper attachment devices,lower hanger attachments,hanger devices, and/or hanger attachments are not allowed except where specifically indicated: Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services HVAC DUCTS AND CASINGS 23 31 00 - 4 1.Hook or loop. 2.Nailed pin fasteners. 3.Expansion nails without washers. 4.Powder charged or mechanically driven fasteners (forced entry anchors). 5.Beam or "C"clamps without retaining clips or friction clamps (provide retaining clips 6.for "C"clamps). 7.Friction clamps for ductwork over 12". 8.Non-factory manufactured upper attachments for metal pan deck including wire coil and double circle (Items 16 and 17 of Fig 4-3 of SMACNA HVAC Duct Construction Standards 95). 9.Wire hanger. 10.Trapeze hangers supported by wires or straps. 11.Rods,straps or welded studs directly attached to metal deck. 12.Drilled hole with attachment to structural steel. 13.Lag screw expansion anchor. 14.Rivets. G Supporting devices shall be standard products of manufacturers having published load ratings. H Unless drawings indicate the required framing,provide angle iron framing around roof opening where duct penetrates through roof decking,to maintain roof decking structural integrity in accordance with roof decking manufacturer's recommendations. This is not required for concrete decking. For concrete decking, consult with Structural Engineer for location and size of opening prior to execution of Work. I For welded ducts,soldered ducts or ducts with water tight joints,do not use supports utilizing screws or other penetrations into ductwork. J All hangers and supports shall be fully galvanized. 2.05 METAL DUCTS A Material Requirements: 1.Galvanized Steel: Hot-dipped galvanized steel sheet,ASTM A653/A653M FS Type B,with ​G90/Z275​coating. B Spiral Ducts: Round spiral lockseam duct with galvanized steel outer wall."Paint grip"finish if exposed to view. 1.Manufacture in accordance with SMACNA (DCS). 2.Manufacturers: a.EHG,a DMI Company​​ b.GSI,a DMI Company​​ c.Linx Industries,Inc,a DMI Company d.MKT Metal Manufacturing e.Or Approved Equal 2.06 FLEXIBLE DUCTS A Flexible Air Ducts: 1.UL 181,Class 0,interlocking spiral of aluminum foil. 2.Insulation: Fiberglass insulation with ​aluminized​vapor barrier film. 3.Pressure Rating: 8 in-wc positive or negative. 4.Maximum Velocity: 5,000 fpm. 5.Temperature Range: Minus 20 to 250 degrees F. 2.07 LONGITUDINAL SEAM: A Rectangular Duct: 1.Unless otherwise indicated,use Pittsburgh lock seam construction. 2.Seal longitudinal seams with approved sealant or provide pre-sealed from factory with encapsulated mastic. Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services HVAC DUCTS AND CASINGS 23 31 00 - 5 3.Button punch snap lock construction (SMACNA L-2)is not allowed except for ductwork that is both low pressure (2”WG or lower pressure class)and 18”and smaller duct width. 4.Button punch snap lock construction is not allowed for ductwork in chases and areas above inaccessible ceilings. 5.Button punch snaplock construction is not allowed on exhaust ductwork or aluminum ductwork B Round and Oval Duct 1.Unless otherwise indicated,longitudinal seams shall be in accordance with SMACNA HVAC Duct Construction Standards with the following exceptions: a.Snaplock seams are not allowed. b.SMACNA seam types RL-3,6A,6B,7,and 8 shown in Figure 3-2 are not allowed,except for 2" w.g.class round ducts 16"or less in diameter. 2.08 RECTANGULAR TRANSVERSE JOINT CONNECTORS: A Slide-on Transverse Joint Connectors: 1.Duct constructed using engineered slide-on connector systems must be submitted and conform to manufacturer’s published duct construction standards and guidelines for joint classification,sheet metal gauge,intermediate and joint reinforcement size and spacing,unless otherwise specified. 2.Manufacturer of engineered connector system must have certified independent performance testing for leakage,deflection and seismic stability. 3.All components of the engineered system must be clearly embossed with the manufacturer’s name, model number or identifying marking. 4.Butyl rubber gasket must be applied per the manufacturer’s instructions on all connections except for breakaway connections.Closed Cell Neoprene gasket must be applied per the manufacturer’s instructions on all breakaway connections.No substitution of connector system components or gaskets is permitted. 5.All duct installed using engineered connectors must adhere to the manufacturer’s published assembly and installation guidelines for all standard,breakaway,roof-top or specialty connections unless otherwise specified. B Formed-on Flanges: 1.Lockformers TDC or Engles TDF may be used in accordance with T-25 flanges of SMACNA HVAC Duct Construction Standards,provided that corner pieces with bolts are used. If TDF/TDC flanges are damaged,replace the damaged joint(s)by straightening and reinforcing with minimum 1-1/2 x 1-1/2 x 1/4 angle at each side of transverse joint PART 3 EXECUTION 3.01 INSTALLATION A Install,support,and seal ducts in accordance with SMACNA (DCS). B During construction,provide temporary closures of metal or taped polyethylene on open ductwork to prevent construction dust from entering the ductwork system. C All "paint grip"or mill phosphatized ductwork shall be cleaned and treated and prepped per SSPC/NACE Standard SP-1 prior to application of paint. D Install ductwork parallel to building walls and ceilings and at such heights not to obstruct any portion of window,doorway,stairway,or passageway. Install ductwork to allow adequate access and service space for equipment and access clearances for cable tray/j-hooks.Refer to drawings and/or manufacturer's recommendations Install vertical ductwork plumb. Make allowances for beams,pipes or other obstructions in building construction and for work of other contractors. Check plans showing work of other trades and consult with Engineer in event of any interference. E Where interferences develop in the field,offset or reroute ductwork as required to clear such interferences. Do not divide duct and do not route any other utilities such as piping or conduit through duct. In all cases, consult drawings for exact location of space allocated for duct,ceiling heights,door and window openings, Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services HVAC DUCTS AND CASINGS 23 31 00 - 6 or other architectural details before fabricating or installing duct. Consult Designer where conflicts arise between ductwork and other utilities which cannot be resolved by relocating duct. F Where offsets in ductwork are required,contractor to use standard 30,45 or 90-degree elbows. Where space constraints do not allow for the use of standard elbows for offsets,use of angled offsets as depicted by SMACNA Figure 2-7 (Angled Offset Type 1)may be used with maximum angle of offset not to exceed 15 degrees maximum.Offsets Type 2 and 3 in SMACNA Figure 2-7 shall not be allowed. G Rectangular Duct Elbows: 1.Rectangular Duct:Unless specific type is indicated,provide radius elbows with splitter vanes with minimum centerline radius to width or diameter ratio of 1.5 a.1.5 radius elbows with full splitter vanes as follows: 1)One vane for duct width 2-12" 2)Two vanes for duct width 13-20" 3)Three vanes for duct width 21"-36" 4)Four vanes for duct width 38"and larger 5)Fabricate vanes in accordance with SMACNA. b.Rectangular throat elbows with turning vanes where 1.5 radius elbows do not fit. c.Rectangular throat/radius heel elbows or rectangular elbows without turning vanes shall not be used. H Round and Oval Duct Elbows: 1.Unless specific type is indicated,use radius elbows with centerline radius to diameter ratio of 1.5. ONLY where1.5 radius elbows do not fit,1.0 radius elbows may be used if approved by the Engineer. I Construct ductwork so that interior surfaces are smooth. Internal duct hangers and internal bracing are not allowed. Refer to above for internal tie rods. J Support coils,filters,air terminals,dampers,sound attenuating devices,or other devices installed in duct systems with angles or channels and make all connections to such equipment including equipment furnished by others. Secure frames with gaskets,nuts,bolts and washers. K Flexible ducts shall not exceed 5 feet in length.Bends,kinks,and sagging of flexible duct will not be accepted.The maximum permitted sag is 1/2"per foot of support spacing. L Install outside air intake duct to pitch down at minimum 1”per 20 ft toward intake louver or plenum and to drain to outside of building. Solder or seal seams to form watertight joints. M Install exhaust air duct to pitch down at minimum 1”per 20 ft toward exhaust louver. N Where 2 different metal ducts meet,install joint in such a manner that metal ducts do not contact each other by using proper gasket seal or compound. O Flexible Ducts: Connect to metal ducts with adhesive plus sheet metal screws. 1.Flexible ducts are not allowed for special exhaust systems,such as laboratory exhaust,vehicle exhaust, etc. 2.Splicing of flexible duct will not be allowed. 3.Flexible ducts shall not pass through any partition,wall,floor,or ceiling. P Duct sizes indicated are precise inside dimensions.For lined ducts,maintain sizes inside lining. Q Provide openings in ductwork as indicated to accommodate thermometers and controllers.Provide pilot tube openings as indicated for testing of systems,complete with metal can with spring device or screw to insure against air leakage.For openings,insulate ductwork and install insulation material inside a metal ring. R Locate ducts with sufficient space around equipment to allow normal operating and maintenance activities. S All exposed ductwork to be painted shall be mill bonderized or "paint grip."The contractor shall thoroughly clean all ductwork surfaces to be free from oils,grease,lubricants,and other contaminants prior to application of paint.Follow T Paint interior of metal ducts that are visible through registers and grilles and that do not have duct liner. Apply one coat of flat,black,latex paint over a compatible galvanized steel primer. U Use double nuts and lock washers on threaded rod supports. Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services HVAC DUCTS AND CASINGS 23 31 00 - 7 V Connect terminal units to supply ducts with hard duct. Maintain minimum three (3)feet or three (3)duct diameters (whichever is greater)of straight duct prior to inlet of box.Connecting flex duct to the inlets of terminal units will NOT be acceptable. W Provide minimum 5 ft of straight duct on outlet side of VAV boxes before first tap. X All trapeze hanger rods shall be cut to within 1"of the bottom nut. END OF SECTION 23 31 00 Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services AIR DUCT ACCESSORIES 23 33 00 - 1 SECTION 23 33 00 AIR DUCT ACCESSORIES PART 1 GENERAL 1.01 SECTION INCLUDES A Backdraft dampers -metal. B Duct access doors. C Duct test holes. D Flexible duct connectors. E Volume control dampers. F Miscellaneous Products: 1.Internal strut end plugs. 2.Duct opening closure film. 1.02 REFERENCE STANDARDS A NFPA 90A -Standard for the Installation of Air-Conditioning and Ventilating Systems;2024. B SMACNA (DCS)-HVAC Duct Construction Standards Metal and Flexible;2020. 1.03 SUBMITTALS A Product Data: Provide for shop-fabricated assemblies including volume control dampers,duct access doors, duct test holes,and hardware used.Include electrical characteristics and connection requirements. B Manufacturer's Installation Instructions: Provide instructions for ​fire dampers and combination fire and smoke dampers​. C Project Record Drawings: Record actual locations of access doors and test holes. D Maintenance Materials: Furnish the following for Owner's use in maintenance of project. 1.Extra Fusible Links: One of each type and size. 1.04 QUALITY ASSURANCE A Manufacturer Qualifications: Company specializing in manufacturing the type of products specified in this section,with minimum ​five​years of​documented​experience. B Products Requiring Electrical Connection: Listed and classified by Underwriters Laboratories Inc.as suitable for the purpose specified and indicated. C All dampers shall be certified to bear the AMCA Certified Ratings Program seal for Air Performance, Efficiency,and Air Leakage. 1.05 DELIVERY,STORAGE,AND HANDLING A Protect dampers from damage to operating linkages and blades. B Storage:Store materials in a dry area indoor,protected from physical damage and in accordance with manufacturer's instructions. PART 2 PRODUCTS 2.01 AIR TURNING DEVICES/EXTRACTORS A Manufacturers: 1.Carlisle HVAC Products​​ 2.Elgen Manufacturing,Inc​​ 3.Krueger-HVAC,Division of Air System Components 4.Ruskin Company 5.Titus HVAC,a brand of Johnson Controls​​ 6.Or Approved Equal B Multi-blade device with blades aligned in short dimension;steel construction;with individually adjustable blades,mounting straps. 2.02 DUCT AIR TURNING VANES A Provide factory manufactured turning vanes in each elbow where inside radius is less than the width of the duct,and in all square or rectangular elbows. Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services AIR DUCT ACCESSORIES 23 33 00 - 2 B Turning vane assemblies shall be adequately supported and affixed to prevent rattling,breakaway,and shall not deform.Assemblies longer than 12 inches shall be double wall. C Turning vanes in negative pressure ductwork with pressure rating above 2 inches shall be installed in accordance with SMACNA Industrial Duct Construction Standard. D Turning vanes shall match the duct material construction. E Rectangular Throat Elbow Truning Vanes (Vane Runner Length up to 18"and Vane Length up to 36") 1.Provide single blade type vanes having 2"radius and 1-1/2"spacing,24 gauge minimum. Construct vanes in accordance with SMACNA HVAC Duct Construction Standards. 2.If duct size changes in mitered elbow,use single blade type vanes with trailing edge extension. F Rectangular Throat Elbow Truning Vanes (Vane Runner Length up to 18"and Vane Length up to 36"): 1.Use double wall airfoil type with smoothly-rounded entry nose and extended trailing edge on 2.4" center spacing. 2.Vanes shall be equal to HEP (High Efficiency Profile)vanes as manufactured by Aero/Dyne Co. G Radius Elbow Splitter Vanes: 1.Splitter vanes for radius elbows shall be extended entire length of fitting and constructed in accordance with SMACNA HVAC Duct Construction Standards. H Manufacturers: 1.Aero Dyne 2.Ductmate,Inc. 3.Sheet Metal Connectors,Inc. 4.Duro-Dyne 5.DynAir Inc. 6.Or Approved Equal 2.03 WIRE MESH SCREENS A Screen assemblies shall be removable. B Mesh:1/2 inch square pattern,1/16 inch galvanized wire,interwoven,welded at wire intersections and to the frame to prevent rattles. C Frames:Minimum of 1 inch by 1 inch by 1/8 inch galvanized steel angles for duct sizes through 24 inches, 1-1/2 inch by 1-1/2 inch by 3/16 inch for duct sizes between 25 inches and 48 inches,and 2 inches by 2 inches for ducts larger than 48 inches continuous around perimeter of screen.Provide intermediate supports to limit screen deflection to 1/16 inch at maximum design airflow. 2.04 FLEXIBLE DUCT 90°ELBOW SUPPORT A Manufacturers: 1.Build Right Products 2.Hart and Cooley 3.Thermaflex 4.Or Approved Equal B Pre-manufactured support to form any brand flexible duct into a smooth 90 degree elbow. 1.One size shall fit 4"to 16"flexible ducts 2.No additional tools shall be required for installation 3.UL listed for use in Return Air Plenums 2.05 DUCT ACCESS DOORS A Manufacturers: 1.Acudor Products Inc,a Division of Nelson Industrial Inc​​ 2.Ductmate Industries,Inc,a DMI Company​​ 3.Durodyne 4.Elgen Manufacturing​​ 5.Nailor Industries Inc​​ 6.Ruskin Company​​ Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services AIR DUCT ACCESSORIES 23 33 00 - 3 7.SEMCO LLC​​ 8.Or Approved Equal B Fabrication: Rigid and close fitting of galvanized steel with sealing gaskets and quick-fastening locking devices.For insulated ducts,install minimum 1-inch thick insulation with sheet metal cover. 1.Up to 18 inches Square: Provide two hinges and two sash locks. 2.Up to 24 by 48 inches: Three hinges and two compression latches with outside and inside handles. C Access doors with sheet metal screw fasteners are not acceptable. D Provide access doors of adequate size to allow easy access to the equipment that will require maintenance. Provide insulated or acoustically lined doors to prevent condensation where applicable. E Manufacturer shall provide a neoprene gasket around perimeter of access door for airtight seal. F Systems 2"w.g.or less shall use a hinged,cam,or hinged &cam square framed access door. G Systems 3"w.g.and above shall use a sandwich type access door.Construct doors in accordance with Figure 7-3 of the 2005 SMACNA Manual,"HVAC Duct Construction Standards,Metal &Flexible,"Third Edition. Doors shall be rated for +/-10"w.g. 2.06 DUCT TEST HOLES A Temporary Test Holes: Cut or drill in ducts as required.Cap with neat patches,neoprene plugs,threaded plugs,or threaded or twist-on metal caps. B Permanent Test Holes: Factory fabricated,air tight flanged fittings with screw cap. Provide extended neck fittings to clear insulation. 2.07 VOLUME CONTROL DAMPERS A Manufacturers: 1.MKT Metal Manufacturing​​ 2.Nailor Industries Inc​​ 3.NCA,a brand of Metal Industries Inc​​ 4.Ruskin Company​​: 5.United Enertech​​ 6.Greenheck 7.Pottorff 8.Johnson Controls 9.Air Balance,Inc. 10.Or Approved Equal B Fabricate in accordance with SMACNA (DCS)and as indicated. C Round Control Damper -1 in w.g.and below: 1.Velocity:Up to 2,000 fpm 2.Temperature:180°F 3.Construction: a.Frame Material -Galvanized Steel b.Frame Thickness:20 gauge c.Blade Material:Galvanized Steel d.Axle Bearings:Bronze​​ e.Axle Material:Plated Steel f.Operaror:3/8 inch sq.locking manual quandrant. 1)On insulated ducts,provide 2 inch standoff bracket g.Manufacturers: 1)Greenheck MBDR-50 2)Ruskin 3)Nailor D Round Control Damper -4 in w.g.and below: 1.Velocity:Up to 3,000 fpm Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services AIR DUCT ACCESSORIES 23 33 00 - 4 2.Temperature:180°F 3.Leakage:4 cfm/ft2 @ 1 in.wg 4.Construction: a.Frame Material -Galvanized Steel b.Frame Thickness:20 gauge c.Blade Material:Galvanized Steel d.Blade seal:Silicone e.Axle Bearings:Bronze​​ f.Axle Material:Plated Steel g.Operaror:3/8 inch sq.locking manual quandrant. 1)On insulated ducts,provide 2 inch standoff bracket 5.Manufacturers: a.Greenheck VCDR-53 b.Ruskin c.Nailor E Rectangular Multi-Blade Balancing Dampers:2 in w.g.and below 1.Pressure:Up to 4 in w.g. 2.Velocity:2,000 fpm 3.Temperature:180°F 4.Construction: a.Frame Material -​​Galvanized Steel​​ b.Frame Thickness:16 gauge c.Blade Material:Galvanized Steel d.Blade Thickness:16 gauge e.Blade Type:3V f.Blade Operation:Opposed g.Axle Bearings:Synthetic sleeve type h.Axle Material:​​Plated Steel​​ i.Operaror:1/2 inch locking manual quandrant,1-1/2 inch long standoff bracket j.Extension Pin:1/2 inch diagonal glass reinforced polymer extends 3-1/2 inch beyond frame 5.Manufacturers: a.Greenheck MBD-15 b.Ruskin c.Nailor F Quadrants: 1.Provide locking,indicating quadrant regulators on single and multi-blade dampers. 2.On insulated ducts mount quadrant regulators on stand-off mounting brackets,bases,or adapters. 3.Where rod lengths exceed 30 inches provide regulator at both ends. 2.08 MISCELLANEOUS PRODUCTS A Internal Strut End Plugs: Combination end-mounting and sealing plugs for metal conduit used as internal reinforcement struts for metal ducts;plug crimped inside conduit with outside gasketed washer seal. B Duct Opening Closure Film: Mold-resistant,self-adhesive film to keep debris out of ducts during construction. 1.Thickness: 2 mils. 2.High tack water based adhesive. 3.UV stable light blue color. 4.Elongation Before Break: 325 percent,minimum. 5.Manufacturers: a.Carlisle HVAC Products​;Dynair Duct Protection Film​ Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services AIR DUCT ACCESSORIES 23 33 00 - 5 b.Surface Shields c.Trimaco d.Ductmate ProGuard e.Or Approved Equal PART 3 EXECUTION 3.01 INSTALLATION A Install accessories in accordance with manufacturer's instructions,NFPA 90A,and follow SMACNA (DCS). See Section 23 31 00 for duct construction and pressure class. B Provide a pre-manufactured support at each diffuser to turn the flex duct into a 90°elbow. C Contractor shall identify balancing dampers above the ceiling by either spray painting them bright orange or hanging an orange flag from the damper handle.If hanging a flag in a return air plenum,material shall comply with fire and smoke spread ratings for plenum use. D All balancing dampers shall be installed maximum 30"above the lay-in ceiling. E Provide duct access doors for inspection and cleaning before and after filters,coils,fans,automatic dampers, at fire dampers,combination fire and smoke dampers,and elsewhere as indicated.​​​​Provide minimum ​​12 by 12 inch​​size for hand access, size for shoulder access,and as indicated. Provide ​​8 by 8 inch​​for balancing dampers only. Review locations prior to fabrication. F Provide duct test holes where indicated and required for testing and balancing purposes. G Provide balancing dampers at points on supply,return,and exhaust systems where branches are taken from larger ducts as required for air balancing.Install minimum two duct widths from duct take-off. H Provide balancing dampers on duct take-off to diffusers,grilles,and registers,regardless of whether dampers are specified as part of the diffuser,grille,or register assembly. END OF SECTION 23 33 00 Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services AIR OUTLETS AND INLETS 23 37 00 - 1 SECTION 23 37 00 AIR OUTLETS AND INLETS PART 1 GENERAL 1.01 SECTION INCLUDES A Diffusers: B Registers/grilles: 1.Ceiling-mounted,exhaust and return register/grilles. 2.Ceiling-mounted,supply register/grilles. 3.Wall-mounted,supply register/grilles. 4.Wall-mounted,exhaust and return register/grilles. 1.02 REFERENCE STANDARDS A AMCA 550 -Test Method for High Velocity Wind Driven Rain Resistant Louvers;2022. B ASHRAE Std 70 -Method of Testing the Performance of Air Outlets and Air Inlets;2023. C SMACNA (ASMM)-Architectural Sheet Metal Manual;2012. 1.03 SUBMITTALS A Product Data: Provide data for equipment required for this project.Review outlets and inlets as to size, finish,and type of mounting prior to submission.Submit schedule of outlets and inlets showing type,size, location,application,and noise level. B Provide performance data for each inlet and outlet model and size variation,indicating CFM range,throw data,noise data,and pressure drop. 1.04 QUALITY ASSURANCE A Test and rate air outlet and inlet performance in accordance with ASHRAE Std 70. B Louver shall comply with AMCA 540 and AMCA 550. C Louvers licensed to bear AMCA Certified Ratings Seal.Ratings based on tests and procedures performed in accordance with AMCA 500-L,AMCA 511 and AMCA 540 and comply with AMCA Certified Ratings Program.AMCA Certified Ratings Seal applies to air performance and water penetration ratings. D Manufacturer Qualifications:Company specializing in manufacturing the type of products specified in this section,with minimum ​three​years of​documented​experience. PART 2 PRODUCTS 2.01 MANUFACTURERS A Carnes,a division of Carnes Company Inc​​ B Krueger​​ C Metalaire,a brand of Metal Industries Inc​​:www.metalaire.com/#sle. D Nailor E Price Industries​​ F Ruskin Company​​ G Titus​​ H Tuttle and Bailey​​ I Or Approved Equal 2.02 SQUARE CONE DIFFUSERS A Type:Provide ​square,adjustable pattern,stamped,multi-core​diffuser to discharge air in ​four way​pattern​​. B Connections: Round. C Frame:Provide ​surface mount and inverted T-bar​type.​In plaster ceilings,provide plaster frame and ceiling frame.​ D Fabrication:​Aluminum​with ​baked enamel​finish. E Color: As indicated. 2.03 SQUARE PLAQUE DIFFUSERS A Type:Provide ​aluminum​square plaque ceiling diffusers of sizes and mounting types designated by the Drawings and air distribution schedule. Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services AIR OUTLETS AND INLETS 23 37 00 - 2 B An inner plaque assembly shall be incorporated and shall drop no more than ¼inch below the ceiling plane to assure proper air distribution performance. C The inner plaque assembly shall be completely removable from the room side to allow for full access to any dampers or other ductwork components located near the diffuser neck. D The diffuser shall integrate with all duct sizes shown on the plans without affecting the face size and appearance of the unit. E The face panel shall have smooth edges and rounded corners to blend with the back cone. F Frame:Provide ​surface mount and inverted T-bar​type.In plaster ceilings,provide plaster frame and ceiling frame. G The ceiling module size shall be as indicated on the Drawings. 2.04 WALL SUPPLY REGISTERS/GRILLES A Type:Streamlined and individually adjustable blades,​3/4 inch​minimum depth,​3/4 inch​maximum spacing with spring or other device to set blades,​vertical​face,​double​deflection. B Frame: 1-1/4 inch margin with countersunk screw mounting and gasket. C Fabrication: Steel with 20 gauge,0.0359 inch minimum frames and 22 gauge,0.0299 inch minimum blades, steel and aluminum with 20 gauge,0.0359 inch minimum frame,or aluminum extrusions,with factory baked enamel finish. D Color: As indicated. E Damper: Integral,gang-operated opposed blade type with removable key operator,operable from face. 2.05 WALL EXHAUST AND RETURN REGISTERS/GRILLES A Type: Streamlined blades,3/4 inch minimum depth,3/4 inch maximum spacing,with spring or other device to set blades,vertical face. B Frame: 1-1/4 inch margin with countersunk screw mounting. C Fabrication: Steel frames and blades,with factory baked enamel finish. D Color: As indicated on the drawings. E Damper: Integral,gang-operated,opposed blade type with removable key operator,operable from face. 2.06 DRYER VENT A Manufacturers 1.Seiho 2.Or Approved Equal B Heavy duty aluminum construction with flapper backdraft damper C Size:4"or 6"as scheduled or indicated on Drawings D Finish:Anodized PART 3 EXECUTION 3.01 INSTALLATION A Install in accordance with manufacturer's instructions. B Comply with SMACNA (ASMM)for flashing/counter-flashing of roof penetrations and supports for roof curbs and roof mounted equipment. C Check location of outlets and inlets and make necessary adjustments in position to comply with architectural features,symmetry,and lighting arrangement. D Install diffusers to ductwork with air tight connection. E Provide balancing dampers on duct take-off to diffusers and grilles and registers,despite whether dampers are specified as part of diffuser,or grille and register assembly. F Paint ductwork visible behind air outlets and inlets matte black,see Section 09 91 23. G Inspect areas to receive louvers.Notify the Architect of conditions that would adversely affect the installation or subsequent utilization of the louvers.Do not proceed with installation until unsatisfactory conditions are corrected. H Install louvers plumb,level,and in alignment with adjacent work. Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services AIR OUTLETS AND INLETS 23 37 00 - 3 I The supporting structure shall be designed to accommodate the point loads transferred by the louvers when subject to the design wind loads.Coordinate with the General Contractor and Framing Contractor. END OF SECTION 23 37 00 Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services ELECTRICAL DEMOLITION 26 05 05 - 1 SECTION 26 05 05 ELECTRICAL DEMOLITION PART 1 GENERAL 1.01 SECTION INCLUDES A Electrical demolition. PART 2 PRODUCTS 2.01 MATERIALS AND EQUIPMENT A Materials and equipment for patching and extending work. PART 3 EXECUTION 3.01 EXAMINATION A Verify field measurements and circuiting arrangements are as indicated. B Report discrepancies to Architect before disturbing existing installation. 3.02 PREPARATION A Disconnect electrical systems in walls,floors,and ceilings to be removed. B Coordinate utility service outages with utility company. C Provide temporary wiring and connections to maintain existing systems in service during construction. When work must be performed on energized equipment or circuits,use personnel experienced in such operations. D Existing Electrical Service: Maintain existing system in service until new system is complete and ready for service. Disable system only to make switchovers and connections. Minimize outage duration. 1.Obtain permission from Owner at least 48 hours before de-energizing system. E Fire alarm system shall be maintained to all occupied portions of the building. 1.Notify Owner and Fire Marshall a least 48 hours before partially or completely disabling system. 2.If the Fire alarm system cannot be maintained in the occupied portion of the building contractor shall provide a fire watch in accordance with NFPA 72 and local authority requirements. 3.03 DEMOLITION AND EXTENSION OF EXISTING ELECTRICAL WORK A Perform work for removal and disposal of equipment and materials containing toxic substances regulated under the Federal Toxic Substances Control Act (TSCA)in accordance with applicable federal,state,and local regulations.Lamps are to be disposed of in accordance with NC G.S.130A -310.60.Applicable equipment and materials include,but are not limited to: 1.PCB-containing electrical equipment,including transformers,capacitors,and switches. 2.PCB-and DEHP-containing lighting ballasts. 3.Mercury-containing lamps and tubes,including fluorescent lamps,high intensity discharge (HID),arc lamps,ultra-violet,high pressure sodium,mercury vapor,ignitron tubes,neon,and incandescent. B Remove,relocate,and extend existing installations to accommodate new construction. C Remove abandoned wiring to source of supply. D Remove exposed abandoned conduit,including abandoned conduit above accessible ceiling finishes. Where conduit cannot be removed from floors or walls,cut conduit flush with walls and floors,and patch surfaces. E Disconnect abandoned outlets and remove devices. Remove abandoned outlets if conduit servicing them is abandoned and removed. Provide blank cover for abandoned outlets that are not removed. F Repair adjacent construction and finishes damaged during demolition and extension work. G Maintain access to existing electrical installations that remain active. Modify installation or provide access panel as appropriate. H Remove all devices from walls or ceilings shown to be removed on the Architectural drawings wether shown on the electrical demolition plans or not. I Where existing downstream devices are to remain,extend existing branch circuit conduit and conductors to maintain service. Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services ELECTRICAL DEMOLITION 26 05 05 - 2 3.04 CLEANING AND REPAIR A Clean and repair existing materials and equipment that remain or that are to be reused. END OF SECTION 26 05 05 Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services POWER CONDUCTORS AND CABLES 26 05 19 - 1 SECTION 26 05 19 POWER CONDUCTORS AND CABLES PART 1 GENERAL 1.01 SECTION INCLUDES A Single conductor building wire. B Wiring connectors. C Electrical tape. D Oxide inhibiting compound. E Wire pulling lubricant. 1.02 REFERENCE STANDARDS A ASTM B3 -Standard Specification for Soft or Annealed Copper Wire;2013 (Reapproved 2024). B ASTM B8 -Standard Specification for Concentric-Lay-Stranded Copper Conductors,Hard,Medium-Hard, or Soft;2023. C ASTM B33 -Standard Specification for Tin-Coated Soft or Annealed Copper Wire for Electrical Purposes; 2010,with Editorial Revision (2020). D ASTM B787/B787M -Standard Specification for 19 Wire Combination Unilay-Stranded Copper Conductors for Subsequent Insulation;2004 (Reapproved 2020). E NFPA 70 -National Electrical Code;National Fire Protection Association,Including All Applicable Amendments and Supplements;2023. 1.03 SUBMITTALS A Product Data: Provide manufacturer's standard catalog pages and data sheets for conductors and cables, including detailed information on materials,construction,ratings,listings,and available sizes, configurations,and stranding. B Field Quality Control Test Reports. C Manufacturer's Installation Instructions: Indicate application conditions and limitations of use stipulated by product testing agency.Include instructions for storage,handling,protection,examination,preparation,and installation of product. D Project Record Documents: Record actual installed circuiting arrangements.Record actual routing of exterior below grade conduit and associated hand holes or man holes.. E Maintenance Materials: Furnish the following for Owner's use in maintenance of project. 1.04 QUALITY ASSURANCE A Comply with requirements of NFPA 70. B Manufacturer Qualifications: Company specializing in manufacturing the products specified in this section with minimum five years documented experience. C Product Listing Organization Qualifications: Third party agencies shall be amongst those accredited by the NCBCC (North Carolina Building Code Council)to label Electrical and Mechanical Equipment. 1.05 DELIVERY,STORAGE,AND HANDLING A Receive,inspect,handle,and store conductors and cables in accordance with manufacturer's instructions. 1.06 FIELD CONDITIONS A Do not install or otherwise handle thermoplastic-insulated conductors at temperatures lower than 14 degrees F,unless otherwise permitted by manufacturer's instructions.When installation below this temperature is unavoidable,notify Architect and obtain direction before proceeding with work. PART 2 PRODUCTS 2.01 CONDUCTOR AND CABLE APPLICATIONS A Do not use conductors and cables for applications other than as permitted by NFPA 70 and product listing. B Provide single conductor building wire installed in suitable raceway unless otherwise indicated,permitted,or required. C Nonmetallic-sheathed cable is not permitted. D Service entrance cable is not permitted. Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services POWER CONDUCTORS AND CABLES 26 05 19 - 2 2.02 CONDUCTOR AND CABLE GENERAL REQUIREMENTS A Provide products that comply with requirements of NFPA 70. B Provide products listed,classified,and labeled as suitable for the purpose intended. C All conductors shall be labeled two feet on centers indicating size,type,voltage,rating,and manufacturer's name. D Provide new conductors and cables manufactured not more than one year prior to installation. E Unless specifically indicated to be excluded,provide all required conduit,boxes,wiring,connectors,etc.as required for a complete operating system. F Comply with NEMA WC 70. G Conductor Material: 1.Provide copper conductors except where aluminum conductors are specifically indicated.Substitution of aluminum conductors for copper is not permitted. Conductor sizes indicated are based on copper unless specifically indicated as aluminum. Conductors designated with the abbreviation "AL"indicate aluminum. 2.Copper Conductors: Soft drawn annealed,98 percent conductivity,uncoated copper conductors. 3.Aluminum Conductors (only where specifically indicated or permitted for substitution): AA-8000 series aluminum alloy conductors. H Minimum Conductor Size:12 AWG. I Maximum Conductor Size:500 kcmil J Conductors for branch circuits shall be sized to prevent a voltage drop exceeding three percent (3%)at the farthest outlet of power,heating and lighting loads,or any combination of such loads. The maximum total voltage drop on both feeders and branch circuits to the farthest outlet shall not exceed five percent (5%). 1.Where the conductor length from the panel to the first outlet on a 120 volt circuit exceeds 50 feet,the branch circuit conductors from the panel to the first outlet shall not be smaller than #10 AWG. Increase the branch circuit conductor size an additional wire size for reach 100’of additional length of the entire circuit. The ground conductor size shall be increased proportionately to the increase in the phase conductors per 2020 NEC 250.122(B). K Conductor Color Coding: 1.Color code conductors as indicated unless otherwise required by the authority having jurisdiction. Maintain consistent color coding throughout project. 2.Color Coding Method: a.Conductors #10 AWG and smaller shall be factory color coded. b.Conductors #3 and larger shall be factory color coded on the entire length. 3.Color Code: a.480Y/277 V,3 Phase,4 Wire System: 1)Phase A: Brown. 2)Phase B: Orange. 3)Phase C: Yellow. 4)Neutral/Grounded: Gray. b.208Y/120 V,3 Phase,4 Wire System: 1)Phase A: Black. 2)Phase B: Red. 3)Phase C: Blue. 4)Neutral/Grounded: White. c.Equipment Ground,All Systems: Green. d.0 -10V Dimming conductors:Violet and Grey 2.03 BUILDING WIRE A Approved Manufacturers as listed below or approved equal: 1.Copper or Aluminum Building Wire: Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services POWER CONDUCTORS AND CABLES 26 05 19 - 3 a.Triangle b.Okonite c.Houston Wire and Cable d.or approved equal B Description: Single conductor insulated wire. C Conductor Stranding: 1.Feeders and Branch Circuits: a.Size 10 AWG and Smaller: Solid. b.Size 8 AWG and Larger: Class B Stranded. D Insulation Voltage Rating: 600 V. E Insulation: 1.Copper Building Wire: Type THHN/THWN or XHHW-2. 2.Conductors routed on roofs or other exterior surface where raceway is exposed to direct sunlight shall be type XHHW-2 insulation. 3.Aluminum Building Wire (only where specifically indicated or permitted for substitution): Type XHHW-2. 2.04 WIRING CONNECTORS A Description: Wiring connectors appropriate for the application,suitable for use with the conductors to be connected,and listed as complying with UL 486A-486B or UL 486C as applicable. B Connectors for Grounding and Bonding: Comply with Section 26 05 26. C Wiring Connectors for Splices and Taps: 1.Splices or taps shall not be allowed for feeder conductors unless specifically noted on plans. 2.Where a splice or tap for feeder conductors is noted on the plans,connectors shall be Blackburn insulated multi-tap or approved equal. 3.Splices in branch circuit conductors shall be allowed in accessible junction boxes,troughs,or gutters. a.Copper Conductors #10 AWG and smaller: Use twist-on insulated spring connectors. b.Copper Conductors #8 AWG and larger: Use mechanical connectors with gum rubber tape or friction tape.Solderless mechanical connectors with UL listed insulating covers may be used at contractor's option. 4.Use of split bolts is not allowed. 5."Sta-kon"or other permanent type crimp connectors shall not be used for branch circuit connections. D Wiring Connectors for Terminations: 1.Provide terminal lugs for connecting conductors to equipment furnished with terminations designed for terminal lugs. 2.Provide compression adapters for connecting conductors to equipment furnished with mechanical lugs when only compression connectors are specified. 3.Where over-sized conductors are larger than the equipment terminations can accommodate,provide connectors suitable for reducing to appropriate size,but not less than required for the rating of the overcurrent protective device. E Twist-on Insulated Spring Connectors: Rated 600 V,221 degrees F for standard applications and 302 degrees F for high temperature applications;pre-filled with sealant and listed as complying with UL 486D for damp and wet locations. 2.05 ACCESSORIES A Electrical Tape: 1.Vinyl Color Coding Electrical Tape: Integrally colored to match color code indicated;listed as complying with UL 510;minimum thickness of 7 mil;resistant to abrasion,corrosion,and sunlight; suitable for continuous temperature environment up to 221 degrees F. a.Product: Okonite 2000 or approved equal. Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services POWER CONDUCTORS AND CABLES 26 05 19 - 4 2.Vinyl Insulating Electrical Tape: Complying with ASTM D3005 and listed as complying with UL 510;minimum thickness of 7 mil;resistant to abrasion,corrosion,and sunlight;conformable for application down to 0 degrees F and suitable for continuous temperature environment up to 221 degrees F. B Oxide Inhibiting Compound: Listed;suitable for use with the conductors or cables to be installed. C Wire Pulling Lubricant: Listed;suitable for use with the conductors or cables to be installed and suitable for use at the installation temperature. PART 3 EXECUTION 3.01 EXAMINATION A Verify that interior of building has been protected from weather. B Verify that work likely to damage wire and cable has been completed. C Verify that raceways,boxes,and equipment enclosures are installed and are properly sized to accommodate conductors and cables in accordance with NFPA 70. D Verify that field measurements are as indicated. E Verify that conditions are satisfactory for installation prior to starting work. 3.02 PREPARATION A Clean raceways thoroughly to remove foreign materials before installing conductors and cables. 3.03 INSTALLATION A Circuiting Requirements: 1.Circuit routing indicated is diagrammatic. 2.Maintain separation of Class 1,Class 2,and Class 3 remote-control,signaling,and power-limited circuits in accordance with NFPA 70. 3.0 -10V lighting dimming conductors may not be routed in the same raceway with line voltage conductors. 4.Maintain separation of wiring for emergency systems in accordance with NFPA 70. 5.Common Neutrals: Unless otherwise indicated,sharing of neutral/grounded conductors among up to three single phase branch circuits of different phases installed in the same raceway is not permitted. Provide dedicated neutral/grounded conductor for each individual branch circuit. 6.A dedicated green equipment grounding conductor shall be provided for all raceways containing branch circuit or feeder conductors.Equipment ground conductor shall be sized in accordance with the NEC. B Install products in accordance with manufacturer's instructions. C Install conductors and cable in a neat and workmanlike manner.Neatly train and lace wiring inside boxes, equipment,and panelboards. D Installation in Raceway: 1.Tape ends of conductors and cables to prevent infiltration of moisture and other contaminants. 2.Pull all conductors and cables together into raceway at same time. 3.Do not damage conductors and cables or exceed manufacturer's recommended maximum pulling tension and sidewall pressure. 4.Use suitable wire pulling lubricant for conductors #4 AWG or larger,except when lubricant is not recommended by the manufacturer. E Paralleled Conductors: Install conductors of the same length and terminate in the same manner. F Secure and support conductors and cables in accordance with NFPA 70 using suitable supports and methods approved by the authority having jurisdiction. Provide independent support from building structure. Do not provide support from raceways,piping,ductwork,or other systems. G Install conductors with a minimum of 12 inches of slack at each outlet. H Neatly train conductors inside boxes,wireways,panelboards and other equipment enclosures.Condcutors shall not be laced or bundled to avoid overheating. Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services POWER CONDUCTORS AND CABLES 26 05 19 - 5 I Group or otherwise identify neutral/grounded conductors with associated ungrounded conductors inside enclosures in accordance with NFPA 70. J Make wiring connections using specified wiring connectors. 1.Remove appropriate amount of conductor insulation for making connections without cutting,nicking or damaging conductors. 2.Do not remove conductor strands to facilitate insertion into connector. 3.Clean contact surfaces on conductors and connectors to suitable remove corrosion,oxides,and other contaminates.Do not use wire brush on plated connector surfaces. 4.Connections for Aluminum Conductors: Fill connectors with oxide inhibiting compound where not pre-filled by manufacturer. K Insulate ends of spare conductors using vinyl insulating electrical tape. L Unless specifically indicated to be excluded,provide final connections to all equipment and devices, including those furnished by others,as required for a complete operating system. 3.04 FIELD QUALITY CONTROL A All tests shall be completely documented indicating time of day,date,temperature and all pertinent test information.All required documentation shall be submitted to the Engineer prior to,and as a prerequisite for, final acceptance of the project.All test results shall be included in the Owner's operation and maintenance manual. B Inspect and test in accordance with NETA ATS,Section 7.3.2. 1.Perform each of the following visual and electrical tests: a.Compare cable data with drawings and specifications to ensure compliance with contract documents. b.Inspect exposed sections of conductor and cable for physical damage and correct connection according to the single-line diagram. c.Test bolted connections for high resistance using one of the following: 1)A low-resistance ohmmeter. 2)Calibrated torque wrench. d.Inspect compression-applied connectors for correct cable match and indentation. e.Inspect for correct identification. f.Inspect cable jacket and condition. g.Continuity test on each conductor and cable. h.Uniform resistance of parallel conductors. C Insulation resistance test is required for all feeder conductors prior to energizing feeders,sub-feeders,or service entrance conductors. 1.All current carrying feeder phase conductors and neutrals shall be tested as installed,and before connections are made,for insulation resistance and accidental grounds. This shall be done with a 500 volt insulation resistance tester. In the procedures listed below shall be followed: a.Minimum readings shall be one million (1,000,000)or more ohms for #6 AWG wire and smaller, 250,000 ohms or more for #4 AWG wire or larger,between conducts and between conductor and the grounding conductor. b.After all fixtures,devices and equipment are installed and all connections completed to each panel,the Contractor shall disconnect the neutral feeder conductor from the neutral bar and take a insulation resistance reading between the neutral bar and the grounded enclosure. If this reading is less than 250,000 ohms,the Contractor shall disconnect the branch circuit neutral wires from this neutral bar. He shall then test each one separately to the panel and until the low readings are found. The Contractor shall correct troubles,reconnect and retest until at 250,000 ohms from the neutral bar to the grounded panel can be achieved with only the neutral feeder disconnected. Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services POWER CONDUCTORS AND CABLES 26 05 19 - 6 c.The Contractor shall send a letter to the Engineer certifying that the above has been done and tabulating the insulation resistance readings for each panel. This shall be done at least four (4) days prior to final inspection. d.At final inspection,The Contractor shall furnish a insulation resistance tester and show the Engineer’s representatives that the panels comply with the above requirements. He shall also furnish a hook-on type ammeter and voltmeter to take current and voltage readings as directed by the representatives. e.Results of the test shall be made available to the engineer at the required pre-energization walk through. 2.Disconnect surge protective devices (SPDs)prior to performing any high potential testing.Replace SPDs damaged by performing high potential testing with SPDs connected. D Correct deficiencies and replace damaged or defective conductors and cables and re-test as indicated above. Contractor shall submit new test results to the Engineer to demonstrate the deficiency has been corrected. END OF SECTION 26 05 19 Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS 26 05 29 - 1 SECTION 26 05 29 HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS PART 1 GENERAL 1.01 SECTION INCLUDES A Support and attachment requirements and components for equipment,conduit,cable,boxes,and other electrical work. 1.02 RELATED REQUIREMENTS A Section 26 05 33.13 -Conduit for Electrical Systems: Additional support and attachment requirements for conduits. B Section 26 05 36 -Cable Trays for Electrical Systems: Additional support and attachment requirements for cable tray. C Section 26 05 33.16 - Boxes and Cabinets: Additional support and attachment requirements for boxes. 1.03 REFERENCE STANDARDS A NFPA 70 -National Electrical Code;Most Recent Edition Adopted by Authority Having Jurisdiction, Including All Applicable Amendments and Supplements. 1.04 ADMINISTRATIVE REQUIREMENTS A Coordination: B Sequencing: 1.05 SUBMITTALS A Product Data: Provide manufacturer's standard catalog pages and data sheets for channel (strut)framing systems,non-penetrating rooftop supports,and post-installed concrete and masonry anchors. B Manufacturer's Instructions: Indicate application conditions and limitations of use stipulated by product testing agency. Include instructions for storage,handling,protection,examination,preparation,and installation of product. 1.06 QUALITY ASSURANCE 1.07 DELIVERY,STORAGE,AND HANDLING A Receive,inspect,handle,and store products in accordance with manufacturer's instructions. PART 2 PRODUCTS 2.01 SUPPORT AND ATTACHMENT COMPONENTS A General Requirements: 1.Provide all required hangers,supports,anchors,fasteners,fittings,accessories,and hardware as necessary for the complete installation of electrical work. 2.Provide products listed,classified,and labeled as suitable for the purpose intended,where applicable. 3.Where support and attachment component types and sizes are not indicated,select in accordance with manufacturer's application criteria as required for the load to be supported​​.Include consideration for vibration,equipment operation,and shock loads where applicable. 4.Do not use products for applications other than as permitted by NFPA 70 and product listing. B Conduit and Cable Supports: Straps,clamps,etc.suitable for the conduit or cable to be supported. 1.Conduit Straps: One-hole or two-hole type;steel or malleable iron. 2.Conduit Clamps: Bolted type unless otherwise indicated. C Anchors and Fasteners: 1.Concrete: Use preset concrete inserts,expansion anchors,or screw anchors. 2.Solid or Grout-Filled Masonry: Use expansion anchors or screw anchors. 3.Hollow Masonry: Use toggle bolts. 4.Hollow Stud Walls: Use toggle bolts. 5.Steel: Use beam clamps,machine bolts,or welded threaded studs. 6.Sheet Metal: Use sheet metal screws,bolts,or bolts. 7.Wood: Use wood screws. 8.Plastic and lead anchors are not permitted. Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS 26 05 29 - 2 9.Powder-actuated fasteners are not permitted. PART 3 EXECUTION 3.01 EXAMINATION A Verify that field measurements are as indicated. B Verify that mounting surfaces are ready to receive support and attachment components. C Verify that conditions are satisfactory for installation prior to starting work. 3.02 INSTALLATION A Install products in accordance with manufacturer's instructions. B Perform work in accordance with NECA 1 (general workmanship). C Provide independent support from building structure.Do not provide support from piping,ductwork,or other systems. D Do not provide support from suspended ceiling support system or ceiling grid. E Unless specifically indicated or approved by Architect,do not provide support from roof deck. F Do not penetrate or otherwise notch or cut structural members without approval of Structural Engineer. G Equipment Support and Attachment: 1.Securely fasten floor-mounted equipment.Do not install equipment such that it relies on its own weight for support. H Conduits installed on the interior of exterior building walls shall be spaced off the wall surface a minimum of 1/4 inch using "clamp-backs"or strut. I Remove temporary supports. 3.03 FIELD QUALITY CONTROL A Inspect support and attachment components for damage and defects. B Repair cuts and abrasions in galvanized finishes using zinc-rich paint recommended by manufacturer. Replace components that exhibit signs of corrosion. C Correct deficiencies and replace damaged or defective support and attachment components. END OF SECTION 26 05 29 Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services CONDUIT FOR ELECTRICAL SYSTEMS 26 05 33.13 - 1 SECTION 26 05 33.13 CONDUIT FOR ELECTRICAL SYSTEMS PART 1 GENERAL 1.01 SECTION INCLUDES A Galvanized steel rigid metal conduit (RMC). B PVC-coated galvanized steel rigid metal conduit (RMC). C Flexible metal conduit (FMC). D Liquidtight flexible metal conduit (LFMC). E Electrical metallic tubing (EMT). F Conduit fittings. G Accessories. 1.02 REFERENCE STANDARDS A ANSI C80.1 -American National Standard for Electrical Rigid Steel Conduit (ERSC);2020. B ANSI C80.3 -American National Standard for Electrical Metallic Tubing --Steel (EMT-S);2020. C ASTM B633 -Standard Specification for Electrodeposited Coatings of Zinc on Iron and Steel;2023. D ASTM A153/A153M -Standard Specification for Zinc Coating (Hot-Dip)on Iron and Steel Hardware; 2023. E ASTM A123/A123M -Standard Specification for Zinc (Hot-Dip Galvanized)Coatings on Iron and Steel Products;2024. F NECA 101 -Standard for Installing Steel Conduits (Rigid,IMC,EMT);2020. G NECA 111 -Standard for Installing Nonmetallic Raceways (RNC,ENT,LFNC);2025. H NFPA 70 -National Electrical Code;Most Recent Edition Adopted by Authority Having Jurisdiction, Including All Applicable Amendments and Supplements. 1.03 ADMINISTRATIVE REQUIREMENTS A Coordination: 1.Coordinate minimum sizes of conduits with the actual conductors to be installed,including adjustments for conductor sizes increased for voltage drop. 2.Coordinate the arrangement of conduits with structural members,ductwork,piping,equipment and other potential conflicts installed under other sections or by others. 3.Verify exact conduit termination locations required for boxes,enclosures,and equipment installed under other sections or by others. 4.Coordinate the work with other trades to provide roof penetrations that preserve the integrity of the roofing system and do not void the roof warranty. 5.Notify Architect of any conflicts with or deviations from Contract Documents.Obtain direction before proceeding with work. B Sequencing: 1.Do not begin installation of conductors and cables until installation of conduit is complete between outlet,junction and splicing points. 1.04 SUBMITTALS A Product Data: Provide manufacturer's standard catalog pages and data sheets for conduits and fittings. B Project Record Documents: Record actual routing for conduits installed underground exterior to the building envelope. 1.05 QUALITY ASSURANCE A Conduit shall be delivered to the project site in bundles of full length pipes,each length marked with the trademark of the manufacturer and the Underwriters'Laboratories,Inc.stamp. Each conduit length shall be straight,true and free from scales,blisters,burrs and other imperfections. 1.Product Listing Organization Qualifications: Third party agencies shall be amongst those accredited by the NCBCC (North Carolina Building Code Council)to label Electrical and Mechanical Equipment. Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services CONDUIT FOR ELECTRICAL SYSTEMS 26 05 33.13 - 2 1.06 DELIVERY,STORAGE,AND HANDLING A Receive,inspect,handle,and store conduit and fittings in accordance with manufacturer's instructions. PART 2 PRODUCTS 2.01 CONDUIT APPLICATIONS A Do not use conduit and associated fittings for applications other than as permitted by NFPA 70 and product listing. B Unless otherwise indicated and where not otherwise restricted,use the conduit types indicated for the specified applications. C Indoors: Finished spaces (not subject to physical damage) 1.Raceway shall be routed concealed in interior portions of furred spaces,ceilings,and cavities,unless other than concrete or solid plaster where possible. 2.Raceways 2 inch or less shall be allowed to be EMT conduit. 3.All raceways concealed in exterior walls shall be rigid galvanized steel conduit. 4.All raceways larger than 2 inch shall be rigid galvanized conduit. 5.Where surface mounted conduit is required in finished spaces,contractor shall utilize surface metal raceway wire mold. 6.Where there is a transition between RGS in a wall to EMT above ceiling,it shall be made at a junction box above accessible ceiling. 7.Interior,Damp or Wet Locations: Use galvanized steel rigid metal conduit. D Stub Ups 1.All feeder stub ups shall transition below grade from PVC to rigid a minimum of 3 feet horizontally from stub up location. 2.All branch circuit stub ups,where exposed or in non-CMU walls,shall transition to rigid galvanized steel at 90 degree elbow. 3.Schedule 40 rigid polyvinyl (PVC)stub ups are only allowed where conduits come up in CMU walls or the bottom of floor mounted equipment. E Unfinished spaces subject to damage (Electrical,Mechanical etc.) 1.All conduit in unfinished spaces shall rigid galvanized steel.Conduit is not considered subject to damage when installed at least 10 feet above finished floor or tight to structure. 2.Conduits are not required to transition to transition to rigid galvanized steel where they are routed down into panelboards or other wall mounted equipment. F Exposed,Interior finished spaces: Use surface metal raceway as identified on the drawings. 1.Surface metal raceway shall be manufactured by Wiremold or approved equal. 2.A separate equipment ground conductor shall be run in the surface metal raceway. G Connection to vibrating equipment shall be made with flexible metal conduit or liquid tight flexible metal conduit depending on the environment installed. H Connections to Luminaires Above Accessible Ceilings: Use flexible metal conduit shall be allowed. 1.Maximum Length: 6 feet. I Connections to Vibrating Equipment: 1.Dry Locations: Use flexible metal conduit. 2.Damp,Wet,or Corrosive Locations: Use liquidtight flexible metal conduit. 3.Maximum Length: 6 feet unless otherwise indicated. 4.Vibrating equipment includes,but is not limited to: a.Transformers. b.Motors. c.Generators. 2.02 CONDUIT REQUIREMENTS Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services CONDUIT FOR ELECTRICAL SYSTEMS 26 05 33.13 - 3 A Existing Work: Where existing conduits are indicated to be reused,they may be reused only where they comply with specified requirements,are free from corrosion,and integrity is verified by pulling a mandrel through them. B Provide all conduit,fittings,supports,and accessories required for a complete raceway system. C Provide products listed,classified,and labeled as suitable for the purpose intended. D Minimum Conduit Size,Unless Otherwise Indicated: 1.Interior: 3/4 inch (21 mm)trade size. 2.Flexible Connections to Luminaires: ​1/2 inch (13 mm)​trade size. 3.Exterior: 1 inch (27 mm)trade size. 2.03 PVC-COATED GALVANIZED STEEL RIGID METAL CONDUIT (RMC) A Manufacturers: 1.Allied Tube &Conduit. 2.Republic Conduit. 3.Wheatland Tube Company. 4.or approved equal. B Description: NFPA 70,Type RMC galvanized steel rigid metal conduit with external polyvinyl chloride (PVC)coating complying with NEMA RN 1 and listed and labeled as complying with UL 6. C Exterior Coating: Polyvinyl chloride (PVC),nominal thickness of 40 mil. D PVC-Coated Fittings: 1.Manufacturer: Same as manufacturer of PVC-coated conduit to be installed. 2.Non-Hazardous Locations: Use fittings listed and labeled as complying with UL 514B. 3.Exterior Coating: Polyvinyl chloride (PVC),minimum thickness of 40 mil. 2.04 FLEXIBLE METAL CONDUIT AND LIQUIDTIGHT FLEXIBLE METAL CONDUIT (FMC LFMC) A Manufacturers: 1.Allied Tube &Conduit. 2.Republic Conduit. 3.Wheatland Tube Company. 4.or approved equal. B Description: NFPA 70,Type FMC standard wall steel flexible metal conduit listed and labeled as complying with UL 1,and listed for use in classified firestop systems to be used. C Description: NFPA 70,Type LFMC polyvinyl chloride (PVC)jacketed steel flexible metal conduit listed and labeled as complying with UL 360. D Spiral strip construction shall allow the conduit to bend up to four times its internal radius. E Fittings shall be compression type with insulated throats and listed for use with conduit specified. 2.05 ELECTRICAL METALLIC TUBING (EMT) A Manufacturers: 1.Allied Tube &Conduit. 2.Republic Conduit. 3.Wheatland Tube Company. 4.or approved equal. B Description: NFPA 70,Type EMT cold-rolled steel electrical metallic tubing with zinc coating on the inside and protected on the inside by a zinc,enamel or equivalent corrosion-resistant coating complying with ANSI C80.3 and listed and labeled as complying with UL 797. C Fittings: 1.Description: Fittings complying with NEMA FB 1 and listed and labeled as complying with UL 514B. 2.Material: Use steel or malleable iron. 3.Connectors and Couplings: Use hexagonal compression (gland)type. a.Do not use indenter type connectors and couplings. b.Do not use set-screw type connectors and couplings. Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services CONDUIT FOR ELECTRICAL SYSTEMS 26 05 33.13 - 4 2.06 ACCESSORIES A Corrosion Protection Tape: PVC-based,minimum thickness of 20 mil. B Conduit Joint Compound: Corrosion-resistant,electrically conductive;suitable for use with the conduit to be installed. C Solvent Cement for PVC Conduit and Fittings: As recommended by manufacturer of conduit and fittings to be installed. D Pull Strings:Use nylon cord with average breaking strength of not less than 200 pound-force. PART 3 EXECUTION 3.01 EXAMINATION A Verify that field measurements are as indicated. B Verify that mounting surfaces are ready to receive conduits. C Verify that conditions are satisfactory for installation prior to starting work. 3.02 INSTALLATION A Install products in accordance with manufacturer's instructions. B Install conduit in a neat and workmanlike manner tight against walls,columns or ceilings. C The conduit shall bend cold 90 degrees about a radius equal to ten (10)times its own diameter without signs of flaw or fracture in either pipe or protective coverings. All bends and offsets shall be made on a forming tool to prevent the conduit or its coating from being damaged in the bending. D Install galvanized steel rigid metal conduit (RMC)in accordance with NECA 101. E Install PVC-coated galvanized steel rigid metal conduit (RMC)using only tools approved by the manufacturer. F Install rigid polyvinyl chloride (PVC)conduit in accordance with NECA 111. G Conduit Routing: 1.Unless dimensioned,conduit routing indicated is diagrammatic. 2.Conceal all conduits unless specifically indicated to be exposed. 3.Conduits in the following areas may be exposed,unless otherwise indicated: a.Electrical rooms. b.Mechanical equipment rooms. 4.Arrange conduit to maintain maximum headroom,clearances,and access. 5.Arrange conduit to provide no more than the equivalent of four 90 degree bends between pull points. 6.Arrange conduit to provide no more than 100 feet between pull points. 7.In every instance,conduit shall be installed in such a manner that the conductors may readily and easily be drawn or pulled in without strain or damage to the insulation;and,also,so that defective conductors may be readily and easily withdrawn and replaced by new conductors. Long radius bends and a sufficient number of approved pull and junction boxes shall be approved for this purpose,and as may be directed by the Engineer. All conduit shall be securely supported and grounded. 8.Arrange conduit to prevent moisture traps.Provide drain fittings at low points and at sealing fittings where moisture may collect. 9.Where conduits join any couplings or threaded fittings,the ends shall be made watertight. 10.Maintain minimum clearance of 12 inches between conduits and hot surfaces.This includes,but is not limited to: H Conduit Support: 1.Provide all required hangers,supports,anchors,fasteners,fittings,accessories,and hardware as necessary for the complete installation of electrical work. 2.Secure and support conduits in accordance with NFPA 70 and Section 26 05 29 using suitable supports and methods approved by the authority having jurisdiction. 3.Provide independent support from building structure.Do not provide support from piping,ductwork, or other systems. Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services CONDUIT FOR ELECTRICAL SYSTEMS 26 05 33.13 - 5 4.Installation Above Suspended Ceilings: Do not provide support from ceiling support system.Do not provide support from ceiling grid or allow conduits to lay on ceiling tiles. 5.Use conduit strap to support single surface-mounted conduit. a.Use clamp back spacer with conduit strap for damp and wet locations to provide space between conduit and mounting surface. 6.Use metal channel (strut)with accessory conduit clamps to support multiple parallel surface-mounted conduits. 7.Use conduit clamp to support single conduit from beam clamp or threaded rod. 8.Use trapeze hangers assembled from threaded rods and metal channel (strut)with accessory conduit clamps to support multiple parallel suspended conduits. 9.Steel Components: Use corrosion resistant materials suitable for the environment where installed. a.Indoor Dry Locations: Use zinc-plated steel or approved equivalent unless otherwise indicated. b.Outdoor and Damp or Wet Indoor Locations: Use galvanized steel,stainless steel,or approved equivalent unless otherwise indicated. c.Zinc-Plated Steel: Electroplated in accordance with ASTM B633. d.Galvanized Steel: Hot-dip galvanized after fabrication in accordance with ASTM A123/A123M or ASTM A153/A153M. 10.Metal Channel (Strut)Framing Systems: Factory-fabricated continuous-slot metal channel (strut)and associated fittings,accessories,and hardware required for field-assembly of supports. a.Minimum Channel Thickness: Steel sheet,12 gage,0.1046 inch. b.Minimum Channel Dimensions: 1-5/8 inch width by 13/16 inch height. I Connections and Terminations: 1.Use approved zinc-rich paint or conduit joint compound on field-cut threads of galvanized steel conduits prior to making connections. 2.Where two threaded conduits must be joined and neither can be rotated,use three-piece couplings or split couplings.Do not use running threads. 3.Use suitable adapters where required to transition from one type of conduit to another. 4.Terminate threaded conduits in boxes and enclosures using threaded hubs or double lock nuts for dry locations and raintight hubs for wet locations. 5.Provide insulating bushings or insulated throats at all conduit terminations to protect conductors. 6.Secure joints and connections to provide maximum mechanical strength and electrical continuity. 7.Condulet fittings shall not be used in lieu of pull boxes. J Penetrations: 1.Do not penetrate or otherwise notch or cut structural members,including footings and grade beams. 2.Make penetrations perpendicular to surfaces unless otherwise indicated. 3.Where conduits penetrate waterproof membrane,seal as required to maintain integrity of membrane. a.All raceway penetrating exterior walls or other water proof membranes shall slope away from the building with a minimum slope of 4"over 100 feet. 4.Make penetrations for roof-mounted equipment within associated equipment openings and curbs where possible to minimize roofing system penetrations.Where penetrations are necessary,seal as required to preserve integrity of roofing system and maintain roof warranty. 5.Install firestopping to preserve fire resistance rating of partitions and other elements.Refer to penetration details on plans. 6.Where conduits cross building expansion joints or pass between areas with a temperature difference of 14 degrees C,provide expansion fittings on all raceway. K Conduit Movement Provisions: Where conduits are subject to movement,provide expansion and expansion/deflection fittings to prevent damage to enclosed conductors or connected equipment.This includes,but is not limited to: 1.Where conduits cross structural joints intended for expansion,contraction,or deflection. Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services CONDUIT FOR ELECTRICAL SYSTEMS 26 05 33.13 - 6 2.Where conduits are subject to earth movement by settlement or frost. L Condensation Prevention: Where conduits cross barriers between areas of potential substantial temperature differential,provide sealing fitting or approved sealing compound at an accessible point near the penetration to prevent condensation.This includes,but is not limited to: 1.Where conduits pass from outdoors into conditioned interior spaces. 2.Where conduits pass from unconditioned interior spaces into conditioned interior spaces. M Provide 200 pound tensile strength pull string in all empty conduits and in conduits where conductors and cables are to be installed by others.Leave minimum slack of 12 inches at each end.All empty conduits shall terminate in a junction box. N All ducts shall be sealed at terminations,using sealing compound and plugs,as required to withstand 15 psi minimum hydrostatic pressure. 3.03 FIELD QUALITY CONTROL A Repair cuts and abrasions in galvanized finishes using zinc-rich paint recommended by manufacturer. Replace components that exhibit signs of corrosion. B Where coating of PVC-coated galvanized steel rigid metal conduit (RMC)contains cuts or abrasions,repair in accordance with manufacturer's instructions. C Correct deficiencies and replace damaged or defective conduits. 3.04 CLEANING A Clean interior of conduits to remove moisture and foreign matter. 3.05 PROTECTION A Immediately after installation of conduit,use suitable manufactured plugs to provide protection from entry of moisture and foreign material and do not remove until ready for installation of conductors. END OF SECTION 26 05 33.13 Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services BOXES AND CABINETS 26 05 33.16 - 1 SECTION 26 05 33.16 BOXES AND CABINETS PART 1 GENERAL 1.01 SECTION INCLUDES A Outlet and device boxes up to 100 cubic inches,including those used as junction and pull boxes. B Cabinets and enclosures,including junction and pull boxes larger than 100 cubic inches. 1.02 REFERENCE STANDARDS A NEMA EN 10250 -Enclosures for Electrical Equipment (1000 Volts Maximum);2024. B NFPA 70 -National Electrical Code;Most Recent Edition Adopted by Authority Having Jurisdiction, Including All Applicable Amendments and Supplements. 1.03 ADMINISTRATIVE REQUIREMENTS A Coordination: 1.Coordinate the work with other trades to avoid placement of ductwork,piping,equipment,or other potential obstructions within the dedicated equipment spaces and working clearances for electrical equipment required by NFPA 70. 2.Coordinate arrangement of electrical equipment with the dimensions and clearance requirements of the actual equipment to be installed. 3.Coordinate minimum sizes of boxes with the actual installed arrangement of conductors,clamps, support fittings,and devices,calculated according to NFPA 70. 4.Coordinate minimum sizes of pull boxes with the actual installed arrangement of connected conduits, calculated according to NFPA 70. 5.Coordinate the placement of boxes with millwork,furniture,devices,equipment,etc.installed under other sections or by others. 6.Coordinate the work with other trades to preserve insulation integrity. 7.Coordinate the work with other trades to provide walls suitable for installation of flush-mounted boxes where indicated. 8.Notify Architect of any conflicts with or deviations from Contract Documents.Obtain direction before proceeding with work. 1.04 SUBMITTALS A Product Data: Provide manufacturer's standard catalog pages and data sheets for outlet and device boxes, junction and pull boxes,cabinets and enclosures,and floor boxes. B Project Record Documents: Record actual locations for outlet and device boxes,cabinets and enclosures, and floor boxes. 1.05 QUALITY ASSURANCE A Product Listing Organization Qualifications: Third party agencies shall be amongst those accredited by the NCBCC (North Carolina Building Code Council)to label Electrical and Mechanical Equipment. 1.06 DELIVERY,STORAGE,AND HANDLING A Receive,inspect,handle,and store products in accordance with manufacturer's instructions. PART 2 PRODUCTS 2.01 BOXES A General Requirements: 1.The Electrical Contractor shall provide junction boxes,pull boxes,cable,support boxes,and wiring troughs as required by NEC and as otherwise indicated in the Drawings. 2.Do not use boxes and associated accessories for applications other than as permitted by NFPA 70 and product listing. 3.Provide all boxes,fittings,supports,and accessories required for a complete raceway system and to accommodate devices and equipment to be installed. 4.Provide products listed,classified,and labeled as suitable for the purpose intended. Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services BOXES AND CABINETS 26 05 33.16 - 2 5.Where box size is not indicated,size to comply with NFPA 70 but not less than applicable minimum size requirements specified. 6.Provide grounding terminals within boxes where equipment grounding conductors terminate. 7.Each outlet designated on the plans shall be provided with an outlet box. 8.In general,outlets shall be installed at the heights indicated. The Contractor shall examine the plans of and coordinate with all other trades to assure mounting heights are correct for the intended purpose. Assure that all mounting heights comply with the latest version of ADA. Outlets installed at incorrect heights shall be relocated to the correct elevation at the Contractor's expense. B Outlet and Device Boxes Up to 100 cubic inches,Including Those Used as Junction and Pull Boxes: 1.Use sheet-steel boxes for dry locations unless otherwise indicated or required. 2.Use cast iron boxes or cast aluminum boxes for damp or wet locations unless otherwise indicated or required;furnish with compatible weatherproof gasketed covers. 3.Outlet boxes shall be 4"square,2 1/8"deep unless otherwise noted. 4.Use suitable concrete type boxes where flush-mounted in concrete. 5.Use suitable masonry type boxes where flush-mounted in masonry walls. 6.Do not use "through-wall"boxes designed for access from both sides of wall. 7.Sheet-Steel Boxes: Comply with NEMA OS 1,and list and label as complying with UL 514A. 8.Cast Metal Boxes: Comply with NEMA FB 1,and list and label as complying with UL 514A;furnish with threaded hubs. 9.Junction boxes larger than 4"square shall be galvanized and without pre-formed knockouts. 10.Boxes for Supporting Luminaires and Ceiling Fans: Listed as suitable for the type and weight of load to be supported;furnished with fixture stud to accommodate mounting of luminaire where required. 11.Boxes for Ganged Devices: Use multigang boxes of single-piece construction.Do not use field- connected gangable boxes. 12.Manufacturers Recessed: a.Steel City Electric Company b.Metropolitan c.B &C d.or approved equal. 13.Manufacturers Surface: a.Crouse-Hinds b.Appleton c.Rayco d.or approved equal. C Cabinets and Enclosures,Including Junction and Pull Boxes Larger Than 100 cubic inches: 1.Comply with NEMA EN 10250,and list and label as complying with UL 50 and UL 50E,or UL 508A. 2.NEMA EN 10250 Environment Type,Unless Otherwise Indicated: 3.Junction and Pull Boxes Larger Than 100 cubic inches: a.Provide screw-cover or hinged-cover enclosures unless otherwise indicated. b.Boxes 12"square and Larger: Provide hinged-cover enclosures with quick access latches. 4.Cabinets and Hinged-Cover Enclosures,Other Than Junction and Pull Boxes: a.Provide lockable hinged covers,all locks keyed alike unless otherwise indicated. 5.Manufacturers Surface: a.Cooper. b.Hoffman. c.Hubbell Incorporated. d.or approved equal.. Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services BOXES AND CABINETS 26 05 33.16 - 3 PART 3 EXECUTION 3.01 EXAMINATION A Verify that field measurements are as indicated. B Verify that mounting surfaces are ready to receive boxes. C Verify that conditions are satisfactory for installation prior to starting work. 3.02 INSTALLATION A Install products in accordance with manufacturer's instructions. B Perform work in a neat and workmanlike manner. C Arrange equipment to provide maximum clearances. D Unless otherwise indicated,provide separate boxes for line voltage and low voltage systems. E Flush-mount boxes in finished areas unless specifically indicated to be surface-mounted. F Box Locations: 1.Locate boxes in accessible locations. 2.Locate boxes so that wall plates do not span different building finishes. 3.Locate boxes so that wall plates do not cross masonry joints. 4.Unless otherwise indicated,where multiple outlet boxes are installed at the same location at different mounting heights,install along a common vertical center line. 5.Do not install flush-mounted boxes on opposite sides of walls back-to-back.Provide minimum 6 inches horizontal separation unless otherwise indicated. 6.Fire Resistance Rated Walls: Install flush-mounted boxes such that the required fire resistance will not be reduced. G Box Supports: 1.Secure and support boxes in accordance with NFPA 70 and Section 26 05 29 using suitable supports and methods approved by the authority having jurisdiction. H Install boxes plumb and level. I Flush-Mounted Boxes: 1.Install boxes in noncombustible materials such as concrete,tile,gypsum,plaster,etc.so that front edge of box or associated raised cover is not set back from finished surface more than 1/4 inch or does not project beyond finished surface. 2.Install boxes in combustible materials such as wood so that front edge of box or associated raised cover is flush with finished surface. 3.Repair rough openings around boxes in noncombustible materials such as concrete,tile,gypsum, plaster,etc.so that there are no gaps or open spaces greater than 1/8 inch at the edge of the box. J Install boxes as required to preserve insulation integrity. K Metallic Floor Boxes: Install box level at the proper elevation to be flush with finished floor. L Boxes in damp or wet locations shall be provided with gaskets and covers. M Install permanent barrier between ganged wiring devices when voltage difference between adjacent devices exceeds 300 V. N Close unused box openings. O Install blank wall plates on junction boxes and on outlet boxes with no devices or equipment installed or designated for future use. 3.03 CLEANING A Clean interior of boxes to remove dirt,debris,plaster and other foreign material. 3.04 PROTECTION A Immediately after installation,protect boxes from entry of moisture and foreign material until ready for installation of conductors. END OF SECTION 26 05 33.16 Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services IDENTIFICATION FOR ELECTRICAL SYSTEMS 26 05 53 - 1 SECTION 26 05 53 IDENTIFICATION FOR ELECTRICAL SYSTEMS PART 1 GENERAL 1.01 SECTION INCLUDES A Electrical identification requirements. B Identification nameplates and labels. C Wire and cable markers. D Warning signs and labels. 1.02 ADMINISTRATIVE REQUIREMENTS A Coordination: 1.Verify final designations for equipment,systems,and components to be identified prior to fabrication of identification products. B Sequencing: 1.Do not conceal items to be identified,in locations such as above suspended ceilings,until identification products have been installed. 2.Do not install identification products until final surface finishes and painting are complete. 1.03 SUBMITTALS A Product Data: Provide manufacturer's standard catalog pages and data sheets for each product. B Shop Drawings: Provide schedule of items to be identified indicating proposed designations,materials, legends,and formats. 1.04 FIELD CONDITIONS A Do not install adhesive products when ambient temperature is lower than recommended by manufacturer. PART 2 PRODUCTS 2.01 IDENTIFICATION REQUIREMENTS A Identification for Equipment: 1.Use identification nameplate to identify each piece of electrical distribution and control equipment and associated sections,compartments,and components. 2.Available Fault Current Documentation: Use identification label to identify the available fault current and date calculations were performed at locations requiring documentation by NFPA 70 including but not limited to the following. a.Service equipment. B Identification for Conductors and Cables: 1.Color Coding for Power Conductors 600 V and Less: Comply with Section 26 05 19. 2.Identification for Communications Conductors and Cables: Comply with Section 27 10 00. C Identification for Boxes: 1.Use color coded boxes to identify specified systems. a.Color-Coded Boxes: Field-painted per the same color coding as identified in this section for the system contained within. b.Fire alarm junction boxes shall be painted on all sides including the box cover. 2.For boxes concealed above accessible ceilings or exposed in mechanical or electrical rooms use neatly handwritten text using indelible marker to identify circuits enclosed. 3.For exposed boxes in public areas,use only type written labels. D Identification for Devices: 1.Wiring Device and Wallplate Finishes: Comply with Section 26 27 26. 2.Use identification label to identify fire alarm system devices. 3.For devices concealed above suspended ceilings,provide additional identification on ceiling tile below device location. 4.Use identification label to identify receptacles protected by upstream GFI protection,where permitted. E Color Coding Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services IDENTIFICATION FOR ELECTRICAL SYSTEMS 26 05 53 - 2 1.Phenolic Nameplates and associated conduit and boxes shall be identified with the following color scheme.Note:For existing buildings the contractor shall field verify the existing building standard and revise the color scheme to match the existing field conditions.Failure to match existing conditions will result in the contractor correcting the mislabeled equipment at his expense. a.Blue surface white core -120/208V equipment. b.Black surface white core -277/480V equipment. c.Bright red surface white core -fire alarm equipment. d.Dark red (burgundy)surface white core -security equipment. e.Green surface white core -emergency systems. f.Orange surface white core -telephone systems. g.Brown surface white core -data systems. h.White surface black core -paging systems. i.Purple surface white core -TV systems. 2.02 IDENTIFICATION NAMEPLATES AND LABELS A Identification Nameplates: 1.Materials: a.Indoor Clean,Dry Locations: Use plastic nameplates. b.Outdoor Locations: Use plastic nameplates suitable for exterior use. 2.Plastic Nameplates: Two-layer or three-layer laminated electrically non-conductive phenolic with beveled edges;minimum thickness of 1/16 inch;engraved text. 3.Mounting Holes for Mechanical Fasteners: Two,centered on sides for sizes up to 1 inch high;Four, located at corners for larger sizes. 4.Nameplates shall be secured with self tapping stainless steel screws;if screws have sharp ends they shall be protected,otherwise rivets shall be used. B Identification Labels: 1.Materials: Use self-adhesive laminated plastic labels;UV,chemical,water,heat,and abrasion resistant. a.Use only for indoor locations. 2.Text: Use factory pre-printed or machine-printed text.Do not use handwritten text. C Format for Equipment Identification: 1.Minimum Size: 1 inch by 2.5 inches. 2.Text:All capitalized unless otherwise indicated. 3.Minimum Text Height: a.Equipment Designation: 1/2 inch. b.Exception: Provide minimum text height of 1 inch for equipment located more than 10 feet above floor or working platform. D Wiring device circuit labels. 1.All wiring devices (receptacles and switches)shall be labeled with the circuit serving the device.Label shall be a typed adhesive label affixed to the front of the wiring device face plate.Label shall have black text on clear background. 2.03 WARNING SIGNS AND LABELS A Comply with ANSI Z535.2 or ANSI Z535.4 as applicable. B Warning Signs: 1.Materials: C Warning Labels: 1.Materials: Use factory pre-printed or machine-printed self-adhesive polyester or self-adhesive vinyl labels;UV,chemical,water,heat,and abrasion resistant;produced using materials recognized to UL 969. Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services IDENTIFICATION FOR ELECTRICAL SYSTEMS 26 05 53 - 3 2.Machine-Printed Labels: Use thermal transfer process printing machines and accessories recommended by label manufacturer. PART 3 EXECUTION 3.01 PREPARATION A Clean surfaces to receive adhesive products according to manufacturer's instructions. 3.02 INSTALLATION A Install products in accordance with manufacturer's instructions. B Install identification products to be plainly visible for examination,adjustment,servicing,and maintenance. C Install identification products centered,level,and parallel with lines of item being identified. D Secure nameplates to exterior surfaces of enclosures using stainless steel screws. E Install self-adhesive labels and markers to achieve maximum adhesion,with no bubbles or wrinkles and edges properly sealed. F Install underground warning tape above buried lines with one tape per trench at six to eight inches below finished grade. G Secure rigid signs using stainless steel screws. H Mark all handwritten text,where permitted,to be neat and legible. 3.03 FIELD QUALITY CONTROL A Replace self-adhesive labels and markers that exhibit bubbles,wrinkles,curling or other signs of improper adhesion. END OF SECTION 26 05 53 Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services LIGHTING CONTROL DEVICES 26 09 23 - 1 SECTION 26 09 23 LIGHTING CONTROL DEVICES PART 1 GENERAL 1.01 SECTION INCLUDES A Occupancy sensors. 1.02 REFERENCE STANDARDS A NFPA 70 -National Electrical Code;Most Recent Edition Adopted by Authority Having Jurisdiction, Including All Applicable Amendments and Supplements. 1.03 ADMINISTRATIVE REQUIREMENTS A Coordination: 1.Coordinate the placement of wall switch occupancy sensors with actual installed door swings. 2.Coordinate the placement of occupancy sensors with millwork,furniture,equipment or other potential obstructions to motion detection coverage installed under other sections or by others. 3.Notify Architect of any conflicts or deviations from Contract Documents to obtain direction prior to proceeding with work. B Sequencing: 1.Do not install lighting control devices until final surface finishes and painting are complete. 1.04 SUBMITTALS A Product Data: Include ratings,configurations,standard wiring diagrams,dimensions,colors,service condition requirements,and installed features. 1.Occupancy Sensors: Include detailed motion detection coverage range diagrams. B Shop Drawings: 1.Occupancy Sensors: Provide lighting plan indicating location,model number,and orientation of each occupancy sensor and associated system component. C Field Quality Control Reports. D Manufacturer's Installation Instructions: Include application conditions and limitations of use stipulated by product testing agency.Include instructions for storage,handling,protection,examination,preparation,and installation of product. E Operation and Maintenance Data: Include detailed information on device programming and setup. F Maintenance Materials: Furnish the following for Owner's use in maintenance of project. G Project Record Documents: Record actual installed locations and settings for lighting control devices. 1.05 QUALITY ASSURANCE A Comply with requirements of NFPA 70. B Maintain at the project site a copy of each referenced document that prescribes execution requirements. C Product Listing Organization Qualifications: Third party agencies shall be amongst those accredited by the NCBCC (North Carolina Building Code Council)to label Electrical and Mechanical Equipment. 1.06 DELIVERY,STORAGE,AND PROTECTION A Store products in a clean,dry space in original manufacturer's packaging in accordance with manufacturer's written instructions until ready for installation. 1.07 FIELD CONDITIONS A Maintain field conditions within manufacturer's required service conditions during and after installation. 1.08 WARRANTY A Provide five year manufacturer warranty for all occupancy sensors. PART 2 PRODUCTS 2.01 LIGHTING CONTROL DEVICES - GENERAL REQUIREMENTS A Provide products listed,classified,and labeled as suitable for the purpose intended. B Unless specifically indicated to be excluded,provide all required conduit,wiring,connectors,hardware, components,accessories,etc.as required for a complete operating system. Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services LIGHTING CONTROL DEVICES 26 09 23 - 2 2.02 OCCUPANCY SENSORS A Manufacturers: 1.Lutron Electronics Company,Inc. 2.Sensor Switch Inc. 3.WattStopper. 4.Approved Equal. 5.Source Limitations: Furnish products produced by a single manufacturer and obtained from a single supplier. B All Occupancy Sensors: 1.Description: Factory-assembled commercial specification grade devices for indoor use capable of sensing both major motion,such as walking,and minor motion,such as small desktop level movements,according to published coverage areas,for automatic control of load indicated. 2.Sensor Technology: a.Passive Infrared (PIR)Occupancy Sensors: Designed to detect occupancy by sensing movement of thermal energy between zones. b.Ultrasonic Occupancy Sensors: Designed to detect occupancy by sensing frequency shifts in emitted and reflected inaudible sound waves. c.Passive Infrared/Ultrasonic Dual Technology Occupancy Sensors: Designed to detect occupancy using a combination of both passive infrared and ultrasonic technologies. 3.Provide LED to visually indicate motion detection. 4.Operation: Unless otherwise indicated,occupancy sensor to turn load on when occupant presence is detected and to turn load off when no occupant presence is detected during an adjustable turn-off delay time interval. 5.Dual Technology Occupancy Sensors: Field configurable turn-on and hold-on activation with settings for activation by either or both sensing technologies. 6.Passive Infrared Lens Field of View: Field customizable by addition of factory masking material, adjustment of integral blinders,or similar means to block motion detection in selected areas. 7.Turn-Off Delay: Field adjustable,with time delay settings up to 30 minutes. 8.Sensitivity: Field adjustable. 9.Adaptive Technology: Field selectable;capable of self-adjusting sensitivity and time delay according to conditions. 10.Isolated Relay for Low Voltage Occupancy Sensors: SPDT dry contacts,for interface with HVAC systems. C Wall Switch Occupancy Sensors: 1.All Wall Switch Occupancy Sensors: a.Description: Occupancy sensors designed for installation in standard wall box at standard wall switch mounting height with a field of view of 180 degrees,integrated manual control capability, and no leakage current to load in off mode. b.Unless otherwise indicated or required to control the load indicated on drawings,provide line voltage units with self-contained relay. c.Where indicated,provide two-circuit units for control of two separate lighting loads,with separate manual controls and separately programmable operation for each load. d.Finish: Match finishes specified for wiring devices in Section 26 27 26,unless otherwise indicated. 2.Dual Technology wall switch occupancy sensors: Capable of detecting motion within an area of 35 x 30 foot area for major motion and a 20 x 15 foot area for minor motion. a.Products: 1)Single Button:Wattstopper DW-100. 2)Two Button:Wattstopper DW-200. Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services LIGHTING CONTROL DEVICES 26 09 23 - 3 3)or approved equal. D Ceiling Mounted Occupancy Sensors: 1.All Ceiling Mounted Occupancy Sensors: a.Description: Low profile occupancy sensors designed for ceiling installation. b.Unless otherwise indicated or required to control the load indicated on drawings,provide low voltage units,for use with separate compatible accessory power packs. c.Provide field selectable setting for disabling LED motion detector visual indicator. d.Occupancy sensor to be field selectable as either manual-on/automatic-off or automatic on/off. e.Finish: White unless otherwise indicated. 2.Passive Infrared (PIR)Ceiling Mounted Occupancy Sensors: a.Standard Range Sensors: Capable of detecting motion within an area of 500 square feet coverage at a mounting height of 8 feet,with a field of view of 360 degrees. 1)Products: (a)Wattstopper CI-200-1. (b)Approved Equal. b.Extended Range Sensors: Capable of detecting motion within an area of 2,000 square feet coverage at a mounting height of 15 feet,with a field of view of 360 degrees. 1)Products: (a)Wattstopper CX-100. (b)or approved equal. 3.Ultrasonic Ceiling Mounted Occupancy Sensors: a.Extended Range Sensors: Capable of detecting motion within an area of 1,100 square feet coverage at a mounting height of 12 feet,with a field of view of 360 degrees. 1)Products: (a)Room Sensors:Wattstopper WT1100. (b)Corridor Sensor with 90 linear feet of coverage Wattstopper WT 2250. (c)or approved equal. 4.Passive Infrared/Ultrasonic Dual Technology Ceiling Mounted Occupancy Sensors: a.Extended Range Sensors: Capable of detecting motion within an area of 1,000 square feet coverage 9 feet,with a field of view of 360 degrees. 1)Products: (a)Wattstopper DT-300. E Directional Occupancy Sensors: 1.All Directional Occupancy Sensors: Designed for wall or ceiling mounting,with integral swivel for field adjustment of motion detection coverage. a.Unless otherwise indicated or required to control the load indicated on drawings,provide low voltage units,for use with separate compatible accessory power packs. b.Provide field selectable setting for disabling LED motion detector visual indicator. c.Finish: White unless otherwise indicated. 2.Passive Infrared (PIR)Directional Occupancy Sensors: 3.Passive Infrared/Ultrasonic Dual Technology Directional Occupancy Sensors: Capable of detecting motion within a distance of 40 feet at a mounting height of 10 feet. a.Products: 1)Wattstopper CX-100. 2)Wattstopper DT-200. 3)or approved equal. F Power Packs for Low Voltage Occupancy Sensors: 1.Description: Plenum rated,self-contained low voltage class 2 transformer and relay compatible with specified low voltage occupancy sensors for switching of line voltage loads. Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services LIGHTING CONTROL DEVICES 26 09 23 - 4 2.Provide quantity and configuration of power and slave packs with all associated wiring and accessories as required to control the load indicated on drawings. 3.Input Supply Voltage: Dual rated for 120/277 V ac. 4.Power packs shall be capable of fitting in a standard 4"square junction box. 5.Load Rating: As required to control the load indicated on drawings. 6.Provide isolated relay for interface with HVAC units. PART 3 EXECUTION 3.01 EXAMINATION A Verify that field measurements are as indicated. B Verify that outlet boxes are installed in proper locations and at proper mounting heights and are properly sized to accommodate devices and conductors in accordance with NFPA 70. C Verify that openings for outlet boxes are neatly cut and will be completely covered by devices or wall plates. D Verify that final surface finishes are complete,including painting. E Verify that branch circuit wiring installation is completed,tested,and ready for connection to lighting control devices. F Verify that the service voltage and ratings of lighting control devices are appropriate for the service voltage and load requirements at the location to be installed. G Verify that conditions are satisfactory for installation prior to starting work. 3.02 PREPARATION A Provide extension rings to bring outlet boxes flush with finished surface. B Clean dirt,debris,plaster,and other foreign materials from outlet boxes. 3.03 INSTALLATION A Perform work in a neat and workmanlike manner in accordance. B Coordinate locations of outlet boxes provided under Section 26 05 33.16 as required for installation of lighting control devices provided under this section. 1.Mounting Heights: Unless otherwise indicated,as follows: a.Wall Switch Occupancy Sensors: 48 inches above finished floor. 2.Orient outlet boxes for vertical installation of lighting control devices unless otherwise indicated. C Install lighting control devices in accordance with manufacturer's instructions. D Unless otherwise indicated,connect lighting control device grounding terminal or conductor to branch circuit equipment grounding conductor and to outlet box with bonding jumper. E Install lighting control devices plumb and level,and held securely in place. F Where required and not furnished with lighting control device,provide wall plate in accordance with Section 26 27 26. G Provide required supports in accordance with Section 26 05 29. H Where applicable,install lighting control devices and associated wall plates to fit completely flush to mounting surface with no gaps and rough opening completely covered without strain on wall plate.Repair or reinstall improperly installed outlet boxes or improperly sized rough openings. I Occupancy Sensor Locations: 1.Location Adjustments: Locations indicated are diagrammatic and only intended to indicate which rooms or areas require devices.Provide quantity and locations as required for complete coverage of respective room or area based on manufacturer's recommendations for installed devices. 2.Locate ultrasonic and dual technology passive infrared/ultrasonic occupancy sensors a minimum of 6 feet from air supply ducts or other sources of heavy air flow and as per manufacturer's recommendations,in order to minimize false triggers. J Unless otherwise indicated,install power packs for lighting control devices above accessible ceiling near the sensor location. K Unless otherwise indicated,install switches on load side of power packs so that switch does not turn off power pack. Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services LIGHTING CONTROL DEVICES 26 09 23 - 5 3.04 FIELD QUALITY CONTROL A Provide System Commissioning in accordance with 2018 NCECC Section C408. B Inspect each lighting control device for damage and defects. C Test occupancy sensors to verify proper operation,including time delays and ambient light thresholds where applicable.Verify optimal coverage for entire room or area. D Correct wiring deficiencies and replace damaged or defective lighting control devices. 3.05 ADJUSTING A Adjust devices and wall plates to be flush and level. B Adjust occupancy sensor settings to minimize undesired activations while optimizing energy savings,and to achieve desired function as indicated or as directed by Architect. C Adjust position of directional occupancy sensors and outdoor motion sensors to achieve optimal coverage as required. D Where indicated or as directed by Architect or owner,install factory masking material or adjust integral blinders on passive infrared (PIR)and dual technology occupancy sensor lenses to block undesired motion detection. E Adjust time switch settings to achieve desired operation schedule as indicated or as directed by Architect. 3.06 CLEANING A Clean exposed surfaces to remove dirt,paint,or other foreign material and restore to match original factory finish. 3.07 CLOSEOUT ACTIVITIES A Demonstration: Demonstrate proper operation of lighting control devices to Architect,and correct deficiencies or make adjustments as directed. B Training: Train Owner's personnel on operation,adjustment,programming,and maintenance of lighting control devices. 1.Use operation and maintenance manual as training reference,supplemented with additional training materials as required. 2.Provide minimum of two hours of training. 3.Instructor: Qualified contractor familiar with the project and with sufficient knowledge of the installed lighting control devices. 4.Location: At project site. END OF SECTION 26 09 23 Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services WIRING DEVICES 26 27 26 - 1 SECTION 26 27 26 WIRING DEVICES PART 1 GENERAL 1.01 SECTION INCLUDES A Wall switches. B Wall dimmers. C Receptacles. D Wall plates. 1.02 REFERENCE STANDARDS A UL 20 -General-Use Snap Switches;Current Edition,Including All Revisions. B UL 498 -Attachment Plugs and Receptacles;Current Edition,Including All Revisions. C UL 514D -Cover Plates for Flush-Mounted Wiring Devices;Current Edition,Including All Revisions. D UL 1472 -Solid-State Dimming Controls;Current Edition,Including All Revisions. E NFPA 70 -National Electrical Code;National Fire Protection Association,Including All Applicable Amendments and Supplements;2023. 1.03 ADMINISTRATIVE REQUIREMENTS A Coordination: 1.Coordinate the placement of outlet boxes with millwork,furniture,equipment,etc.installed under other sections or by others. 2.Coordinate wiring device ratings and configurations with the electrical requirements of actual equipment to be installed. 3.Coordinate the placement of outlet boxes for wall switches with actual installed door swings. 4.Coordinate the installation and preparation of uneven surfaces,such as split face block,to provide suitable surface for installation of wiring devices. 5.Notify Architect of any conflicts or deviations from Contract Documents to obtain direction prior to proceeding with work. B Sequencing: 1.Do not install wiring devices until final surface finishes and painting are complete. 1.04 SUBMITTALS A Product Data: Provide manufacturer's catalog information showing dimensions,colors,and configurations. 1.Wall Dimmers: Include derating information for ganged multiple devices. B Certificates for Surge Protection Receptacles: Manufacturer's documentation of listing for compliance with UL 1449. C Field Quality Control Test Reports. D Manufacturer's Installation Instructions: Indicate application conditions and limitations of use stipulated by product testing agency.Include instructions for storage,handling,protection,examination,preparation,and installation of product. E Operation and Maintenance Data: 1.Wall Dimmers: Include information on operation and setting of presets. 2.GFCI Receptacles: Include information on status indicators. F Project Record Documents: Record actual installed locations of wiring devices. G Maintenance Materials: Furnish the following for Owner's use in maintenance of project. 1.Screwdrivers for Tamper-Resistant Screws: Two for each type of screw. 1.05 QUALITY ASSURANCE A Comply with requirements of NFPA 70. B Maintain at the project site a copy of each referenced document that prescribes execution requirements. C Products: Listed,classified,and labeled as suitable for the purpose intended. D Product Listing Organization Qualifications: Third party agencies shall be amongst those accredited by the NCBCC (North Carolina Building Code Council)to label Electrical and Mechanical Equipment. Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services WIRING DEVICES 26 27 26 - 2 1.06 DELIVERY,STORAGE,AND PROTECTION A Store in a clean,dry space in original manufacturer's packaging until ready for installation. PART 2 PRODUCTS 2.01 WIRING DEVICE APPLICATIONS A Provide wiring devices suitable for intended use and with ratings adequate for load served. B For single receptacles installed on an individual branch circuit,provide receptacle with ampere rating not less than that of the branch circuit. C Provide weather resistant GFCI receptacles with specified weatherproof covers for receptacles installed outdoors or in damp or wet locations. D Provide GFCI protection for receptacles installed within 6 feet of sinks. E Unless noted otherwise,do not use combination switch/receptacle devices. 2.02 WIRING DEVICE FINISHES A Provide wiring device finishes as described below unless otherwise indicated. B Wiring Devices,Unless Otherwise Indicated: ​White​with​​​stainless steel​wall plate. C Wiring Devices Installed ​in Finished Spaces​: ​White​with​​​stainless steel​wall plate. D Wiring Devices Installed ​in Unfinished Spaces​: ​White​with​​​galvanized steel​wall plate. 2.03 WALL SWITCHES A Manufacturers: 1.Hubbell Incorporated​​: www.hubbell.com/#sle. 2.Leviton Manufacturing Company,Inc​​. 3.Pass &Seymour,a brand of Legrand North America,Inc​​ 4.​Approved Equal​. B Wall Switches -General Requirements: AC only,quiet operating,general-use snap switches with silver alloy contacts,complying with NEMA WD 1 and NEMA WD 6,and listed as complying with UL 20​​;types as indicated​on the drawings​. 1.Wiring Provisions: Terminal screws for side wiring and screw actuated binding clamp for back wiring with separate ground terminal screw. C Standard Wall Switches:​Industrial heavy duty grade​,​20​A,​120/277​V with ​standard toggle type​switch actuator and maintained contacts;​single pole single throw,three way,or four way​as indicated​on the drawings​. 2.04 WALL DIMMERS A Manufacturers: 1.Leviton Manufacturing Company,Inc​​. 2.Lutron Electronics Company,Inc​​. 3.Pass &Seymour,a brand of Legrand North America,Inc​​ 4.​Or approved equal​. B Wall Dimmers -General Requirements: Solid-state with continuous full-range even control following square law dimming curve,integral radio frequency interference filtering,power failure preset memory,air gap switch accessible without removing wall plate,complying with NEMA WD 1 and NEMA WD 6,and listed as complying with UL 1472;types and ratings suitable for load controlled as indicated on the drawings. C Provide accessory wall switches to match dimmer appearance when installed adjacent to each other. D Contractor shall ensure dimmer switch compatibility with luminaire controlled prior to ordering. 2.05 RECEPTACLES A Manufacturers: 1.Hubbell Incorporated​​: www.hubbell.com/#sle. 2.Leviton Manufacturing Company,Inc​​. 3.Pass &Seymour,a brand of Legrand North America,Inc​​. 4.​Approved equal​. Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services WIRING DEVICES 26 27 26 - 3 5.Source Limitations: Where wall controls are furnished as part of lighting control system,provide accessory matching receptacles and wallplates by the same manufacturer in locations indicated. B Receptacles -General Requirements: Self-grounding,complying with NEMA WD 1 and NEMA WD 6,and listed as complying with UL 498and where applicable FS W-C-596;types as indicated on the drawings. 1.Wiring Provisions: Terminal screws for side wiring or screw actuated binding clamp for back wiring with separate ground terminal screw. 2.NEMA configurations specified are according to NEMA WD 6. C Convenience Receptacles: 1.Standard Convenience Receptacles: Tamper Resistant ​Industrial Heavy Duty Grade​,​20A,125V, NEMA 5-20R​​​;single or duplex as indicated​on the drawings​. D GFCI Receptacles: 1.GFCI Receptacles -General Requirements: Tamper Resistant Self-testing,with feed-through protection and light to indicate ground fault tripped condition and loss of protection;listed as complying with UL 943,class A. a.Provide test and reset buttons of same color as device. 2.Standard GFCI Receptacles: ​Extra Heavy Duty Grade​,duplex,​20A,125V,NEMA 5-20R​​,rectangular decorator style​. 3.Weather Resistant GFCI Receptacles: Tamper Resistant ​Commercial specification grade​,duplex,​20A, 125V,NEMA 5-20R​​,rectangular decorator style​,listed and labeled as weather resistant type complying with UL 498 Supplement SE suitable for installation in damp or wet locations. 2.06 WALL PLATES A Manufacturers: 1.Hubbell Incorporated​​. 2.Leviton Manufacturing Company,Inc​​. 3.Pass &Seymour,a brand of Legrand North America,Inc​​. 4.Source Limitations: Where wall controls are furnished as part of lighting control system,provide accessory matching receptacles and wallplates by the same manufacturer in locations indicated. B Wall Plates: Comply with UL 514D. 1.Configuration: One piece cover as required for quantity and types of corresponding wiring devices. 2.Size: ​Semi-Jumbo​​;Midi Size​. 3.Screws: Metal with slotted heads finished to match wall plate finish. C Stainless Steel Wall Plates: Brushed satin finish,Type 302 stainless steel. D Galvanized Steel Wall Plates: Rounded corners and edges,with corrosion resistant screws. E Weatherproof Covers for Wet and Damp Locations: Gasketed,​thermoplastic​,with self-closing hinged cover and corrosion-resistant screws;listed as suitable for use in wet locations with cover closed.Covers must be weatherproof while in use. PART 3 EXECUTION 3.01 EXAMINATION A Verify that field measurements are as indicated. B Verify that outlet boxes are installed in proper locations and at proper mounting heights and are properly sized to accommodate devices and conductors in accordance with NFPA 70. C Verify that wall openings are neatly cut and will be completely covered by wall plates. D Verify that final surface finishes are complete,including painting. E Verify that branch circuit wiring installation is completed,tested,and ready for connection to wiring devices. F Verify that conditions are satisfactory for installation prior to starting work. 3.02 PREPARATION A Provide extension rings to bring outlet boxes flush with finished surface. B Clean dirt,debris,plaster,and other foreign materials from outlet boxes. Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services WIRING DEVICES 26 27 26 - 4 3.03 INSTALLATION A Perform work in a neat and workmanlike manner​​. B Coordinate locations of outlet boxes provided under Section 26 05 33.16 as required for installation of wiring devices provided under this section. 1.Orient outlet boxes for vertical installation of wiring devices unless otherwise indicated. 2.Where multiple receptacles,wall switches,or wall dimmers are installed at the same location and at the same mounting height,gang devices together under a common wall plate. 3.Locate receptacles for electric drinking fountains concealed behind drinking fountain according to manufacturer's instructions.These receptacles shall be served with a GFCI breaker. C Install wiring devices in accordance with manufacturer's instructions. D Install permanent barrier between ganged wiring devices when voltage between adjacent devices exceeds 300 V. E Where required,connect wiring devices using pigtails not less than 6 inches long.Do not connect more than one conductor to wiring device terminals. F Connect wiring devices by wrapping conductor clockwise 3/4 turn around screw terminal and tightening to proper torque specified by the manufacturer.Where present,do not use push-in pressure terminals that do not rely on screw-actuated binding. G Unless otherwise indicated,connect wiring device grounding terminal to branch circuit equipment grounding conductor and to outlet box with bonding jumper. H Provide GFCI receptacles with integral GFCI protection at each location indicated.Do not use feed-through wiring to protect downstream devices. I Install wiring devices plumb and level with mounting yoke held rigidly in place. J Install wall switches with OFF position down. K Install wall dimmers to achieve full rating specified and indicated after derating for ganging as instructed by manufacturer. L Do not share neutral conductor on branch circuits utilizing wall dimmers. M Install vertically mounted receptacles with grounding pole on top and horizontally mounted receptacles with grounding pole on left. N Where receptacles are indicated to be mounted above counters they shall be mounted horizontally. O Install wall plates to fit completely flush to wall with no gaps and rough opening completely covered without strain on wall plate.Repair or reinstall improperly installed outlet boxes or improperly sized rough openings.​​ P Install blank wall plates on junction boxes and on outlet boxes with no wiring devices installed or designated for future use. 3.04 FIELD QUALITY CONTROL A Inspect each wiring device for damage and defects. B Operate each ​wall switch and wall dimmer​with circuit energized to verify proper operation. C Test each receptacle to verify operation and proper polarity. D Test each GFCI receptacle for proper tripping operation according to manufacturer's instructions. E Correct wiring deficiencies and replace damaged or defective wiring devices. 3.05 ADJUSTING A Adjust devices and wall plates to be flush and level. B Adjust presets for wall dimmers according to manufacturer's instructions as directed by Architect. 3.06 CLEANING A Clean exposed surfaces to remove dirt,paint,or other foreign material and restore to match original factory finish. END OF SECTION 26 27 26 Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services INTERIOR AND EXTERIOR LIGHTING 26 51 00 - 1 SECTION 26 51 00 INTERIOR AND EXTERIOR LIGHTING PART 1 GENERAL 1.01 SECTION INCLUDES A Interior luminaires. B Emergency lighting units. C Exit signs. D Ballasts and drivers. E Fluorescent emergency power supply units. F Lamps. G Accessories. 1.02 REFERENCE STANDARDS A IES LM-79 -Approved Method: Optical and Electrical Measurements of Solid-State Lighting Products; 2024. B NFPA 70 -National Electrical Code;Most Recent Edition Adopted by Authority Having Jurisdiction, Including All Applicable Amendments and Supplements. C NFPA 101 -Life Safety Code;Most Recent Edition Adopted by Authority Having Jurisdiction,Including All Applicable Amendments and Supplements. D UL 924 -Emergency Lighting and Power Equipment;Current Edition,Including All Revisions. E UL 935 -Fluorescent-Lamp Ballasts;Current Edition,Including All Revisions. F UL 1598 -Luminaires;Current Edition,Including All Revisions. 1.03 ADMINISTRATIVE REQUIREMENTS A Coordination: 1.Coordinate the installation of luminaires with mounting surfaces installed under other sections or by others.Coordinate the work with placement of supports,anchors,etc.required for mounting. Coordinate compatibility of luminaires and associated trims with mounting surfaces at installed locations. 2.Coordinate the placement of luminaires with structural members,ductwork,piping,equipment, diffusers,fire suppression system components,and other potential conflicts installed under other sections or by others. 3.Coordinate the placement of exit signs with furniture,equipment,signage or other potential obstructions to visibility installed under other sections or by others. 4.Notify Architect of any conflicts or deviations from Contract Documents to obtain direction prior to proceeding with work. 1.04 SUBMITTALS A Shop Drawings: 1.Indicate dimensions and components for each luminaire that is not a standard product of the manufacturer. B Product Data: Provide manufacturer's standard catalog pages and data sheets including detailed information on luminaire construction,dimensions,ratings,finishes,mounting requirements,listings,service conditions, photometric performance,installed accessories,and ceiling compatibility;include model number nomenclature clearly marked with all proposed features. 1.Ballasts: Include wiring diagrams and list of compatible lamp configurations. 2.Lamps: Include rated life,color temperature,color rendering index (CRI),and initial and mean lumen output. C Certificates for Dimming Ballasts: Manufacturer's documentation of compatibility with dimming controls to be installed. D Field quality control reports. Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services INTERIOR AND EXTERIOR LIGHTING 26 51 00 - 2 E Manufacturer's Installation Instructions: Indicate application conditions and limitations of use stipulated by product testing agency. Include instructions for storage,handling,protection,examination,preparation,and installation of product. F Warranties. G Operation and Maintenance Data: Instructions for each product including information on replacement parts. H Maintenance Materials: Furnish the following for Owner's use in maintenance of project. 1.Extra Lenses and Louvers: Two percent of total quantity installed for each type,but not less than one of each type. 2.Extra Lamps: Five percent of total quantity installed for each type,but not less than two of each type. 3.Extra Ballasts: Two percent of total quantity installed for each type,but not less than one of each type. 1.05 QUALITY ASSURANCE A Comply with requirements of NFPA 70. B Maintain at the project site a copy of each referenced document that prescribes execution requirements. C Product Listing Organization Qualifications: Third party agencies shall be amongst those accredited by the NCBCC (North Carolina Building Code Council)to label Electrical and Mechanical Equipment. 1.06 DELIVERY,STORAGE,AND PROTECTION A Receive,handle,and store products according to manufacturer's written instructions. B Keep products in original manufacturer's packaging and protect from damage until ready for installation. 1.07 FIELD CONDITIONS A Maintain field conditions within manufacturer's required service conditions during and after installation. PART 2 PRODUCTS 2.01 LUMINAIRE TYPES A Furnish products as indicated in luminaire schedule included on the drawings. 2.02 LUMINAIRES A Provide products that comply with requirements of NFPA 70. B Provide products that are listed and labeled as complying with UL 1598,where applicable. C Provide products listed,classified,and labeled as suitable for the purpose intended. D Unless otherwise indicated,provide complete luminaires including lamp(s)and all sockets,ballasts, reflectors,lenses,housings and other components required to position,energize and protect the lamp and distribute the light. E Unless specifically indicated to be excluded,provide all required conduit,boxes,wiring,connectors, hardware,supports,trims,accessories,etc.as necessary for a complete operating system. F Provide products suitable to withstand normal handling,installation,and service without any damage, distortion,corrosion,fading,discoloring,etc. G Recessed Luminaires: 1.Ceiling Compatibility: Comply with NEMA LE 4. 2.Luminaires Recessed in Insulated Ceilings: Listed and labeled as IC-rated,suitable for direct contact with insulation and combustible materials. 3.Luminaires Recessed in Sloped Ceilings: Provide suitable sloped ceiling adapters. 4.Luminaires Recessed in Fire Rated Ceiling:Provide fire rated tenting to match the fire resistant rating of the surrounding ceiling. H LED Luminaires: 1.Components: UL 8750 recognized or listed as applicable. 2.Tested in accordance with IES LM-79 and IES LM-80. 3.Outdoor:Provide a minimum of 10 kV integral surge suppression. 4.Indoor:Provide a minimum of 2.5 kV integral surge suppression. I Track Lighting Systems: Provide track compatible with specified track heads,with all connectors,power feed fittings,dead ends,hangers and canopies as necessary to complete installation. Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services INTERIOR AND EXTERIOR LIGHTING 26 51 00 - 3 J Luminaires Mounted in Continuous Rows: Provide quantity of units required for length indicated,with all accessories required for joining and aligning. 2.03 BALLASTS AND DRIVERS A Ballasts/Drivers -General Requirements: 1.Provide ballasts containing no polychlorinated biphenyls (PCBs). 2.Minimum Efficiency/Efficacy: Provide ballasts complying with all current applicable federal and state ballast efficiency/efficacy standards. B Fluorescent Ballasts: 1.All Fluorescent Ballasts: Unless otherwise indicated,provide high frequency electronic ballasts complying with ANSI C82.11 and listed and labeled as complying with UL 935. a.Input Voltage: Suitable for operation at voltage of connected source,with variation tolerance of plus or minus 10 percent. b.Total Harmonic Distortion: Not greater than 10 percent. c.Power Factor: Not less than 0.95. d.Thermal Protection: Listed and labeled as UL Class P,with automatic reset for integral thermal protectors. e.Sound Rating: Class A,suitable for average ambient noise level of 20 to 24 decibels. f.Lamp Compatibility: Specifically designed for use with the specified lamp,with no visible flicker. g.Lamp Operating Frequency: Greater than 20 kHz. 1)Do not operate lamp(s)within the frequencies from 30 kHz through 40 kHz in order to avoid interference with infrared devices. h.Lamp Current Crest Factor: Not greater than 1.7. i.Lamp Wiring Method: 1)Instant Start Ballasts: Parallel wired. 2)Rapid Start Ballasts: Series wired. 3)Programmed Start Ballasts: Provide parallel or series/parallel wired where available; otherwise series wired is acceptable. j.Provide automatic restart capability to restart replaced lamp(s)without requiring resetting of power. k.Ballast Marking: Include wiring diagrams with lamp connections. C Dimmable LED Drivers: 1.Dimming Range: Continuous dimming from 100 percent to ten percent relative light output unless dimming capability to lower level is indicated in the fixture schedule,without flicker. 2.Control Compatibility: Fully compatible with the dimming controls to be installed.Refer to drawings. 3.Square wave inverters shall not be used with LED emergency lighting.Sinusoidal wave inverters must be used. 2.04 EMERGENCY POWER SUPPLY UNITS A Description: Self-contained fluorescent emergency power supply units suitable for use with indicated luminaires,complying with NFPA 101 and all applicable state and local codes,and listed and labeled as complying with UL 924. B Compatibility: 1.Drivers: Compatible with electronic,standard magnetic,energy saving,and dimming AC ballasts, including those with end of lamp life shutdown circuits. C Operation: Upon interruption of normal power source,solid-state control automatically switches connected lamp(s)to the emergency power supply for minimum of 90 minutes of rated emergency illumination,and automatically recharges battery upon restoration of normal power source. D Unit shall have a maximum of 5%total harmonic distortion with sine wave output.Square wave output is not acceptable. Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services INTERIOR AND EXTERIOR LIGHTING 26 51 00 - 4 E Battery: Sealed maintenance-free high-temperature nickel cadmium unless otherwise indicated.Normal expected life of 10 years. F Emergency Illumination Output as defined on the drawings. G Diagnostics: Provide accessible and visible multi-chromatic combination test switch/indicator light to display charge,test,and diagnostic status and to manually activate emergency operation. H Operating Temperature: From 32 degrees F to 122 degrees F unless otherwise indicated or required for the installed location. 2.05 LAMPS A Lamps -General Requirements: 1.Unless explicitly excluded,provide new,compatible,operable lamps in each luminaire. 2.Verify compatibility of specified lamps with luminaires to be installed.Where lamps are not specified, provide lamps per luminaire manufacturer's recommendations. 3.Minimum Efficiency: Provide lamps complying with all current applicable federal and state lamp efficiency standards. 4.Color Temperature Consistency: Unless otherwise indicated,for each type of lamp furnish products which are consistent in perceived color temperature.Replace lamps that are determined by the Architect to be inconsistent in perceived color temperature. a.Unless otherwise noted on the drawings color temperatures shall be as listed below.Notify engineer if there is an inconsistency in color temperatures listed in the fixture schedule prior to ordering. 1)Interior Lighting:3500 K 2)Exterior Lighting:4000 K PART 3 EXECUTION 3.01 EXAMINATION A Verify that field measurements are as indicated. B Verify that outlet boxes are installed in proper locations and at proper mounting heights and are properly sized to accommodate conductors in accordance with NFPA 70. C Verify that suitable support frames are installed where required. D Verify that branch circuit wiring installation is completed,tested,and ready for connection to luminaires. E Verify that conditions are satisfactory for installation prior to starting work. 3.02 PREPARATION A Provide extension rings to bring outlet boxes flush with finished surface. B Clean dirt,debris,plaster,and other foreign materials from outlet boxes. 3.03 INSTALLATION A Coordinate locations of outlet boxes provided under Section 26 05 33.16 as required for installation of luminaires provided under this section. B All luminaire surge suppression shall be evaluated and tested in accordance with ANSI C62.41.2 standard. C Install products in accordance with manufacturer's instructions. D Provide required support and attachment in accordance with Section 26 05 29. E Install luminaires securely,in a neat and workmanlike manner. F Install luminaires plumb and square and aligned with building lines and with adjacent luminaires. G Suspended Ceiling Mounted Luminaires: 1.Do not use ceiling tiles to bear weight of luminaires. 2.Do not use ceiling support system to bear weight of luminaires unless ceiling support system is certified as suitable to do so. 3.Secure surface-mounted and recessed luminaires to ceiling support channels or framing members or to building structure. 4.Secure pendant-mounted luminaires to building structure. 5.Secure lay-in luminaires to ceiling support channels using listed safety clips at four corners. Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services INTERIOR AND EXTERIOR LIGHTING 26 51 00 - 5 6.In addition to ceiling support wires,provide two galvanized steel safety wire(s),minimum 12 gauge, connected from opposing corners of each recessed luminaire to building structure. H Recessed Luminaires: 1.Install trims tight to mounting surface with no visible light leakage. 2.Non-IC Rated Luminaires: Maintain required separation from insulation and combustible materials according to listing. 3.Luminaires Recessed in Fire-Rated Ceilings: Install using accessories and firestopping materials to meet regulatory requirements for fire rating. I Suspended Luminaires: 1.Install using the suspension method indicated,with support lengths and accessories as required for specified mounting height. 2.Provide minimum of two supports for each luminaire,with no more than 4 feet between supports. 3.Install canopies tight to mounting surface. J Wall-Mounted Luminaires: Unless otherwise indicated,specified mounting heights are to center of luminaire. K Install accessories furnished with each luminaire. L Bond products and metal accessories to branch circuit equipment grounding conductor. M Emergency Lighting Units: 1.Unless otherwise indicated,connect unit to unswitched power from same circuit feeding normal lighting in same room or area.Bypass local switches,contactors,or other lighting controls. 2.Install lock-on device on branch circuit breaker serving units,where served by a dedicated circuit. N Fluorescent Emergency Power Supply Units: O Identify luminaires connected to emergency power system in accordance with Section 26 05 53. P Install lamps in each luminaire. Q Lamp Burn-In: Operate lamps at full output for prescribed period per manufacturer's recommendations prior to use with any dimming controls.Replace lamps that fail prematurely due to improper lamp burn-in. 3.04 WARRANTY A Emergency Luminaires:Provide a minimum of 5 year warranty for emergency luminaires.Batteries shall be warranted for 3 years with an additional 3 year pro-rated warranty.Warranty period begins from the date of project acceptance. B Emergency Power supplies and inverters shall have a minimum of 10 year prorated warranty. 3.05 FIELD QUALITY CONTROL A Inspect each product for damage and defects. B Operate each luminaire after installation and connection to verify proper operation. C Test self-powered exit signs,emergency lighting units,and fluorescent emergency power supply units to verify proper operation upon loss of normal power supply.Test shall be conducted for 90 minutes in accordance with NEC 700.Test shall be conducted a maximum of 10 days prior to final inspection and light level readings recorded at the beginning and end of the test shall be submitted to the engineer for review. D Correct wiring deficiencies and repair or replace damaged or defective products.Repair or replace excessively noisy ballasts as determined by Architect. 3.06 ADJUSTING A Aim and position adjustable luminaires to achieve desired illumination as indicated or as directed by Architect.Secure locking fittings in place. B Aim and position adjustable emergency lighting unit lamps to achieve optimum illumination of egress path as required or as directed by Architect or authority having jurisdiction. C Exit Signs with Field-Selectable Directional Arrows: Set as indicated or as required to properly designate egress path as directed by Architect or authority having jurisdiction. Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A Orange County Health Department Improvements Smith Sinnett /2024008 Hillsborough,NC Orange County Asset Management Services INTERIOR AND EXTERIOR LIGHTING 26 51 00 - 6 3.07 CLEANING A Clean surfaces according to manufacturer's instructions to remove dirt,fingerprints,paint,or other foreign material and restore finishes to match original factory finish. 3.08 CLOSEOUT ACTIVITIES A Demonstration: Demonstrate proper operation of luminaires to Architect,and correct deficiencies or make adjustments as directed. B After the designer final inspection prior to SCO final inspection and final acceptance replace all lamps that have failed and clean all lenses. 3.09 PROTECTION A Protect installed luminaires from subsequent construction operations. END OF SECTION 26 51 00 Docusign Envelope ID: 2D852F9B-A7CF-462A-9536-444A53AA848A