Loading...
HomeMy WebLinkAboutAgenda - 12-09-2003-8gORANGE COUNTY BOARD OF COMMISSIONERS ACTION AGENDA ITEM ABSTRACT Meeting Date: December 9, 2003 Action Agenda Item No. ~- q SUBJECT: Contract Approval: Innovative Design for Wastewater Treatment Design Services at Northern Human Services Center and Feasibility Analysis of Sustainable Design Elements DEPARTMENT: Purchasing and Central PUBLIC HEARING: (YIN) No Services ATTACHMENT(S): Cost Proposals for: Feasibility Analysis Defining Optional Strategies Far Sustainable Design Elements Available Far Use At NHSC Wastewater Treatment System Design INFORMATION GONTACT: Pam Jones (919) 245-2652 TELEPHONE NUMBERS: Hillsborough Chapel Hill Durham Mebane 732-8181 968-4501 688-7331 336-227-2031 PURPOSE: To consider approving a contract for: 1, Feasibility analysis of specific sustainable design elements at the Northern Human Services Center (NHSC) per Innovative Design proposal dated April 27, 2003; and 2. Design services related to the wastewater treatment system at the Center. BACKGROUND: On October 27, 2003, the Board endorsed a proposal from Innovative Design that laid out specific areas in which a sustainable design approach for construction might be appropriate. The Board has previously expressed a desire to use the NHSC as a model for sustainable design strategies in future development of the site. In addition, the Board previously approved the feasibility study upon which a grant to the State Energy Office is based. Approval of that request during the current funding cycle does not appear likely. However, since the grant funds were primarily targeted to construct the educational component of the project, the non-funded status of the grant is of little consequence to the actual system construction. Should the grant be funded in the future, the educational component may be constructed. The work accomplished through the acceptance of the feasibility analysis proposal would clearly identify the feasibility of a variety of options and their associated cost, from which the Board could then select its preference. Actual design to complete the work identified would be an additional contract brought forward for Board consideration as work may be funded and scheduled. Item #2 seeks Board approval for the design of the wastewater treatment system using Living Machine or equal technology. As the Board will recall, this technology creates a wetlands environment that naturally treats waste and produces clean water that may subsequently be used for other uses that do not require potable water (such as irrigation). As indicated earlier, a grant request to support the educational component of this project is not likely to be funded and as such will not be constructed at this time. The absence of the educational component will not impact the proper function of the system. The consultant indicates that the project should be designed and ready to bid by March 1, 2004. FINANCIAL IMPACT: The cost of design and construction management services associated with the construction of the wastewater treatment system as quoted by Innovative Design is $72,500. The funds to accomplish the work are budgeted in the Northern Human Services Center capital project fund. Funds are available in the NHSC capital project fund to support the $36,410 contract cost. RECOMMENDATION(S): The Manager recommends that the Board: 1. Exempt this contract from the architect/engineering selection process as provided in GS 143-64-32; 2.. Approve a contract with Innovative Design to conduct a feasibility analysis of elements as identified in the proposal dated April 27, 2003 in an amount not to exceed $36,410; and 3. Approve a contract consistent with the attached cost proposal from Innovative Design to design a wastewater treatment system using living machine technology in an amount not to exceed $72,500, plus incidental expenses that will be paid to consultant on a reimbursement basis; and 4.. Authorize the Chair to sign contracts, contingent upon County Attorney and staff review. ° Innovative D e s i g n 850 W Morgan Street Raleigh, NC 27603 919-832-6303 Fax 919-832-3339 April 27. 2003 Pamela .Jones Director of Purchasing and Central Services Orange County 132 E. King Street Hillsborough, NC 27278 Ms, .Jones: I look forward to the opportunity to work with Orange County on such a challenging and exciting project. The sustainable goals put forth by your commissioners fbr the old Cedar C,rovc School are wondertuh 1 would be very proud to be a part of making them come true, 1 thank you for the opportunity. The following presents a proposed list of optional strategies which I-Iarshad Padia (with Padia Cmrsulting) and I feel are opportunities which should be analyzed. Depending upon your budget for this initial work, you could decide upon the level of effort desired. In our very tentative review, we have also tried to place these option in order, in terms of relative potential benefit (both energy dollar savings and environmental impact). We have also identified a fee associated with each item that would allow us to analyze the particular item in relationship to the overall project. To complete the following work, we will, from an energy perspective. require that the current building be inputted into a total building energy simulation program. l o accomplish this analysis, we use the best program available -DOG 11. To additionally simulate any of the daylighting options, we use a program called DAYL.ITG which allows us to simulate the daylighting contribution at numerous points within each individual room, al! day long, 365 days a year. To determine the actual projected lighting and cooling savings, this DAYLITE program output is, in turn, input into DOE 11, which accounts for the savings occurring from the particular daylighting option in relationship to the other building dynamics. 7o calculate the rainwater savings, we will utilize a program developed by Innovative Design, specifically designed for optimizing the size and design of rainwater catchment systems. The proposed analysis will determine, for each measure, the energy savings (in dollars as well as btus), CO2 savings, and nitrogen savings. This will be compared to the projected cost of each measure. The following outlines the bast audit and analysis costs that will occur. regardless of the specific measures selected. This scope assumes that there are "As-Built ~ plans for the facility and that additional. detailed lield work is no[ required to determine the existing conditions. Base Tasks task Base I: Complete audit of the facility ID 8 hours at $125/hour $ 1,000 12 hours at $90/hour $ 1,080 Padia G hours at $125/hour $ 720 8 hours at $90/hour $ '720 Task Base 2: Input of base building into the DOE Il energy simulation Padia 40 hours at $90/hour $ 3,600 Task Base 3: Coordination with Orange County staff, interim review, information gathering, and final presentation to Orange 1D 20 hours at $125/hour $ 2,500 30 hours at $90/hour $ 2,700 20 hours at $50/hour $ 1,000 Padia 8 hours at $125/hour $ 1,000 4 hours at $90/hour $ 360 Total Base Costs $14,680 The proposed analysis of sustainable options arc broken down into the categories of energy, water, and green products and systems. Energy __ Task E1: Daylighting/window strategies 1D 5 strategies x l0 hours x $90/hour $ 4,500 2 hours x $125/hour $ 250 Padia 2 strategies x 4 hours x $90/hour $ 720 1 hour x $125/hour $ 125 5 Task EZ: Trecshading I D 3 horns X $9O/110UC $ 27O 1 hours x S 125/hour $ 125 Padia 4 hours x $90/hour $ 3GU 1 hour x $ I25/how' $ 12> _ Task G3: Mechanical system options (includes recommendations on ]AQ and ventilation) Padia IS hours s $90/hour $ 1 ,350 2 hours x $125/hour $ 250 _ Task L-4: Lighting modifications Padia 10 hours x $90/hour $ 900 1 hour x $ l25/hour $ 125 Task G5: Root/radiant barrier/insulation strategies ID Z strategies x :3 hours x $90/hour $ 540 1 hour x $125/hour $ 125 Padia 2 strategies x 4 hours x $90/hour $ 720 1 hour x $125/hour $ 125 Task E.6: Natural and fan assist ventilation strategy ID 3 hours x $90/hour $ 270 I hour x $ 125/hour $ 1 ZS Padia 4 hours x $90/hour $ 3G0 1 hour x $125/hour $ 125 Task E.7: Solar hot water system ID 2 hours x $90/hour $ 180 ] hour x $125/hour $ 125 Padia 2 hours x $90/hour $ 180 1 hour x $125hour $ 125 Task E8: Remote PV lights f'or parking lot, park, walks, and "sign" ID 2 hours x $90/hour $ l 8U 1 hour x $125/hour $ 125 Padia 2 hours x $90/hour $ 130 1 hour x $125hour _, Tnsk E9: Unknown (to be detcnnined during audit) tD 3 hours x $90/hour 1 hour x $125/hour Padia 4 hours x $90{hour I hour x $90/hour Total Cnergy Taslcs 1L1-C7 Water $ 125 $ 270 $ 125 $ .360 $ 125 $1.3,590 _ Task W 1: Rainwater catchment system (for toilet flushing and irrigation. One option would be to just look at suPPlYutg stew toilets required for facility/park mtd another would he to modify existing plumbing in gang toilets). Both could help in irrigating ball field. ID 10 hours x $90/hour $ 900 1 hour x $125/hour $ 125 Padia 4 hours x $90/hour $ >60 Z hours x $125/hour $ 250 Task W2: Water Saving fixtures Padia 6 hours x $90/hour $ 540 1 hour x $125/hour $ 125 Task W3: Living Machine in comparison to septic ID l6 hours x $90/hour $ 1,440 3 hours x $125/hour $ 375 Padia 16 hours x $90/hour $ 1,440 3 hours x $125/hour $ 375 Total of'faslcs Wl-W3 $ 1,930 7 Green Products and Systems Task Gl: Recycling systems lid 6 hours x $90/hour $ 540 I hours $125/hour $ 125 _ Task GZ: Pervious pavement ID 3 hours x $90/hour $ 270 1 hour x $125/hour $ 125 Task G3: Misa recycled products TD 10 hours x $90/hour $ 900 2 hours x $125 $ 250 Total Task GI-G.3 $ 2,210 Total of alt tasks $3G,410 Energy Office Proposal Having looked through the grlnts requirements and knowing a little bit mr what some of the other folks will be submitting For, I am suggesting that we pursue the water issues and concentrate on creating an exemplary environmental solution that will serve as a regional example of sound water management. Assuming that you want to go ahead with the majority of this analysis, we will, on your behalf submit a grant proposal to the energy ollice for the Living Machine and Rainwater Catchment Systems. L.et me know as soon as possible if this is acceptable and what percentage of in-kind you want to list (remember that you have to be at least 25% and the more you put in the better your chances will be). I will also need to work with you pretty quickly since the applications are due May 1.3, We will need to coordinate quite a bit on this and we will need some information fiom you regarding the application. 'the application requirements are enclosed. Ultimately, you will be the applicant an, in turn, need to approve everything. 8 1 am not certain if this is the scope of services that you were anticipating bat, from a good quality analysis standpoint, this is what it will take. We could, of"course. reduce the scope but the reliability oC the cost estimates and projected savings would then be less. If we are off base, just let me know and we will adjust if we can.. 1 will he in the ollice Tuesday from 8:30 until noon. Then I will be out until late Friday night., }lowever, if you do want to go aster the grant I will need to work on it that weekend (May 3"t and 4°i). The main time that 1 can work on the grant will be May 3"~ though May 8°'. 1 will try to call you on Tuesday. Thanks again 1'or the chance to work with you Sincerely, ~^ : -~n. ke Nicklas, FAIA President, Innovative L)esign Oranpe County-l.hdnp Machine Proposal Innovative Design Design Proposal for a Living Machine at Orange County's Northern Human Services Center Northern Human Services Center The site for the project Is the Northam Human Servkes Center, boated otf St~~V,yniN Ei ead~ n Cedar Grove, Orange County. Prevbusy an elementary school, the buiding is now used as government otflces by Orange County, Sited on the southwest comer of the bt Is a softball field, shared with the community, Orange County wishes to renovate the facility in a manner that highlights various sustainable features and sets an example for the region, Several sustainable features are currentty being evaluated by the County, induding deylightlng and energy-ettkieM bulid(ng shell strategies, energy-efHclent mechanical and electrical systems, green building produds, sustainable site design and water wnservatkn and management systems. As part of the renovation and extension of the fadiity, the existing wastewater treatment system, that presentty processes 2,700 gallons per day (gpd), is to be expanded to a total treatment capadty of 6,000 gpd. To accomplish this treatment in an environmentally sound manner, Orange County is now desiring to implement an innovative, natural and biologically diverse wastewater treabnent system equal to or equivalent to a Living Machine approach, This innovative, nature) wastewater and reclamation system uses plants in water gardens to naturally perform water purification processes, Project Scope _ Innovative Design's team will design, asslat in bidding, and provide consWctlon administration services to Orange County in Implementing a Living Machine type system capable of treating up to 0,000 gpd of waste. The water will be bblagicaly treated through a system of ponds, The intent Is to have the treated water disposed of onsite. The most likely approach to be Incorporated for this projed is a tidal vertical flow (TVF). The TVF constructed wastewater treatment wetlands operate by cydk flooding and draining through a media bed with cycle periods of a day or lass. The cycle period of a day or less distinguishes these technologies from other flood and drain systems. The tertiary heated effluent would be discharged into either a (t) subsurface nitrification field, {2) subsurface drip irrigation system or (3) surface drip Irrlgatbn system. The choice of these three optlons will depend upon the first phase of this project; a detailed assessment of the existing site and the establishment of pdodties of County. ormae County'I UwMp n+Khine rmw~x. nwvuno+ Z `d 89Etr'oN N01530 3AIltlhONN1 Wdl9~! EOOd '9 ^~N la Task 1: Evaluation of Options The efforts surounding the first task of this work will center around the determination of the key site factors that will dictate the specific type of approach to be pursued, if there are any unknown technical reasons that would prohibit the optons from being pursued, and refining the cost estimate based upon the optimum approach.. This work will be completed within 40 days of approval of contract Task 1.1 Siting Analyals end Preliminary Layout Within one week of signing contract, the county will provkte our team with the already completed surveys that locate the existing wells, septic fields, topographic characteristics, tree locations, buildings, outdoor structures, utilities, setbacks, property lines, and current play areas and the ball field. Additionally, they will provide our team with information on the existing well characeristics (flow rate, tlepth, water contaminants), Based upon initial site evaluations, discussions with your county officials, and Input from state agencies, we will identity potential strategies and the coresponding potentai bcatlons of the various system components. Task 1.2 Solis, Hydraulic, and Fkld Layout This work indudes technical soils and site evaluaton of the options as they relate to regulations required for subsurface systems; hydraulic testlmg of soil using an Amoozemeter (as required far systems greater than 3,000 gpd); one geoprobe boring to groundwater, hydraulic mounding modeling; and the n'drificatlon field layout and speGilcatlons for the 6,000 gpd system. 'The evaluation will also address your cencem regarding any potential impact the system might have on the existing trees, Task 1,3 Evaluation of Existing Plumbing and Electrical This work will consist of a detailed evaluation of the existing plumbing, septic, and well systems in order to determine the optimum connection points and any r~s-piping requirements. The current and antcipated electrical system will also be evaluated as ft relates to the anticipated electrical service demands, We will provide you with a report summarizing our conclusions, Task 1A Evsiuatbn of Functional and Educational impacts We w(11 analyze the site from a functional and an educational standpoint, to determine the best opportunltles and limitations for locating particular components of the system. We will evaluate the maintenance, security and safety Issues and provide you a report summar¢fng our recommendations. Task 1.6 Preliminary Review with County and Stets Agencies Although there will not be enough of the design completed at this point to guarantee final acceptance, we will review the proposed strategy with the appropriate slats and county agendas as to determine their general acceptance of our approach. E °d 89EY ~N N91S34 3~1.1V~ONN1 WdZ9~l EOOZ '9 ~oN Orange County - LNing Marhlne Proposal Task 1.6 Cost Estimate Based upon the recommended strategy, we will refine our cost estimate. Task 1.7 Presentation of Recommended Strategy Once we complete the work listed above, we will make a presentation to the county on the results of this Task 1 work. Task 2: Construction Documents Assuming acceptance of Task 1 results and your desire to continue, we will complete the design the system. This work wlil be completed in two stages and presented to you for your review at each stage of design. The first will be at prellminary design and the second will be at construction documents, Task 2.1 Preltminary Dealpn (Equivalent oT Design DevalopmeM) Ottca the major components of the system are Iderrtltled and spedficaly located on the site and the major remificatbns addressed (issues in Tesk 1,1 through 1,4), we will submH Design Development Plans on: -Main Tidal, Vertipi Flow system (design and speciflcetlons by Living Machine engineers) - Plumbing and Electrical nrodificetions and incorporation of TVF plans into over engineering documents (design and specifications by Padia Consulting) -Architecturel, egress, edugtional, and safety design issues (design and specifications 6y Innovative Design) -Subsurface design (design and spedfieationa by Living Machine engineers, Landis) Task 2.2 Revlew Melding whir County This meeting would take place to review progress and receive input from the county. The meeting would take place after the preliminary design plans are reviewed by the ccunty. if the scope has changed, we will also provide a new anticipated budget Task 2.8 Construction Documents Once review comments ere taken into account, the Construction Documents will be completed in preparaticn for bidding. -Main Tidal, Vertical Fiow system, including all connedksns bade into building and subsurface design (design and specifications by Padia with review by Living Machine engineers and Landis) -Plumbing and Electrical modificatbns (design and specNicegons by Podia Consulting) - Arohitectural, egress, educational, and safety design issues (design and specifications by Innovative Design) oraig. ca~uY~ uw,g M.aune o,w.,aa~o.~ow. Y 'd 8984`gN N91S3~ 3AIlUAONNI Wdl9~l E08b '9 '^gN i~ Task 2A Revises Mssting whh County This meeting would take place to review progress and receive input from the County. The meeting would take place after the consWction documents plans are reviewed by the county.. If the scope has changed, we will also provide a new anticipated budget y Task 2.ti Coordinatbn with Rsvisw Agencies This work would Include up l012 meetings total with the following approving agencies: -Concept with Orange County Headh Department - Concept with DENR Regional Soll Specialist -Concept with DENR OnSite Wastewater Program -Site approval with Orenge County Health Department - Site approval with DENR Regional Soli Specialist -Site hydraulic approval with DENR OnSite Wastewater Progrem Engineer - Engfneefing design approval with DENR On-Site Wastewater Program Engineer - Preliminary A&E review with County -Final A&E review with County Any meetings required, beyond 12 would be considered additional services. Task 3: Bidding The task will involve assisting the county in conducting normal Bidding the project Task 4: Construction Administration This task will involve tasks normally Involved in ConstrucWn Administration, Including the review of shop drawings, processing payment requests and dtange orders, and conducting srie visits. Task 5: Commissioning Once the project has been completed the engineers from the l)ving Machine will make a specific commissioning trip that will include an operedonal instruction sessbn. The Living Machine engineers will also assist the county in locating optional maintenance personnel, help the county to evaluate their suitabdfty, and assist the county in creating a fair maintenance contract with the preferred maintenance provider. Optional Eco-Educational Task This system will serve as an innovative environmental waste water treatment strategy, ran function as a unique aducationai tool for eco•aducadon, As a option to our basic services, we will provide educational slgnage and a display that e~Iains the system's operation, 9 'd 898Y'~N N91S30 3Al1V~ONNI Wdb9~l 8004 '9 '^~N 13 Orange County -4ivinp Mechlne Pmpoaal Design Team: The design team will be lead by Innovative Design and include the following: Innovagve Design Padla Consulting Landis, Inc. LNing Machine, Inc, If the opdon to develop educational displays and signage is exercised, our team will be joined by: Design Dimensions BUtlget: Labor Task 1: Evaluatlon of Options Task Z: Constructbn Doamenls Task 3: 8ldding Task 4: ConstruGion Administration Task 5: Commissloning/Training Total Basic Services Optional Eco-Educatlanal Task Reimbursable Expenses $24,000 $39,750 $ 2,000 $ 6,500 $ 5,500 (~ $77,750 Nta+(4S I 5_'~ r I II"~ The following reimbursable expenses will be billed at the following rates: Postage/Ovemlght Mail Telephone Airfaremotel Mileage Faxes CARD prirrts Additional Services at cost at cast at cost (ahtieipate 3 trips by Living Machine engineer) $.301m1ie $1.25/page $3.00lprint ' Additional services will be billed hourly et the following rates: Prinrapai Architect or Engineer $1251hour Assodate Architect or Engineer $ BDlhour CADD $ 70mour Administraton S 40/hour Biliino 1A1e will bill monthty for the worfc completed to that point, with amounts not to exceed those listed by phase. Amounts billed will be due within 30 days. ompa CouNy's uwq Machine nramm~.~.w w. 9 'd 896tr'~N NOIS30 3A11Vr<ONNI Wdd~~l EOOd '9 '~oN ~- If this is acceptable please sgn below and we can get started. Thts agreement will be followed by a standard AIA Agreement that InGudes these agreed upon terms, Slnceray, Q ~ crik~~-~s.- M Nickles, FAI Presidenk Innova've Design Approved: Date: L 'd 89Eq'aN N01830 3N 1tl~ONNi WdE9~l EOOZ '9 '~~N