Revised 07/20 1 [Departmental Use Only] TITLE Skylights HC FY 2020-2021 NORTH CAROLINA CONSTRUCTION AGREEMENT UNDER $250,000.00 ORANGE COUNTY THIS CONSTRUCTION AGREEMENT (hereinafter called “Agreement”), made as of the 27th day of October, 2020, by and between Carolina Contracting & Investments, Inc., (hereinafter called the “Contractor”), and Orange County, a political subdivision of the State of North Carolina, (hereinafter called the “County,” “Orange County,” or “Owner”). W I T N E S S E T H: That the Contractor and the Owner, for the consideration herein named, agree as follows: 1. CONTRACT DOCUMENTS; PRIORITY The Contract Documents consist of this Agreement, the Request for Proposals, Proposal, Construction Drawings, and Written Specifications. The Contract Documents form the Contract. In the event of any inconsistency between or among the Contract Documents the Contract Documents shall be interpreted in the following order of priority: a. This Agreement. b. Designer Approved Bulletins and Field Orders. c. Request for Proposals and addenda thereto. d. Proposal. 2. SCOPE OF WORK The Contractor shall furnish and deliver all of the materials, and perform all of the work required by this Agreement within the time period stipulated in a written Notice-to-Proceed to be executed by the Contractor and Owner and in accordance with the following enumerated docu ments, which are made a part hereof as if fully contained herein: a. Construction Drawings prepared by Smith Sinnet Architecture (Sheet A1-01 dated June 16, 2020, and OC DSS Hillsborough Commons Skylight Replacement Specifications) b. Written specifications prepared by the project engineer. c. Carolina Contracting & Investments, Inc. proposal dated August 13, 2020 which fully describes the work to be performed. Such work will hereafter be called the “Work”. d. Related documents listed under Section 1 above. DocuSign Envelope ID: 51195338-6F17-4D2B-B990-4A82329E7F4E Revised 07/20 2 3. TERM AND SCHEDULING a. The Contractor agrees to commence work pursuant to the written Notice to Proceed. b. The Contractor agrees to complete substantially all Work by February 27, 2021 or 120 days from the date of the Notice to Proceed. c. Time is of the essence with respect to all dates specified in the Contract Documents as Completion Dates. d. The Contractor shall perform the Work in the time, manner, and form required by the Contract Documents and as stipulated in a written Notice-to-Proceed to be executed by the Contractor and Owner. e. It is expressly understood that the Owner will employ other contractors to perform work as a part of the Project whose work will be performed simultaneously and sequentially with the performance of the Work by the Contractor. It shall be necessary for the Contractor to coordinate its activities with such other contractors, particularly with respect to access to work areas, storage of materials and other common facilities. f. Should the Owner determine that the Contractor is behind schedule Owner may require, at no additional cost to the Owner, the Contractor to expedite and accelerate its efforts, including providing additional resources and working overtime, as necessar y, to perform the Work in accordance with the approved project schedule. 4. STANDARD OF CARE a. The Contractor shall exercise reasonable care and diligence in performing the Work in accordance with the highest generally accepted standards of this type of Contractor practice throughout the United States and in accordance with applicable federal, state and local laws and regulations applicable to the performance of these services. Contractor is solely responsible for the professional quality, accuracy and timely completion and submission of all work. b. The Contractor shall not load or permit any part of the Work to be loaded with a weight that will endanger its safety, intended performance or configuration. c. Contractor shall be responsible for all errors or omissions caused by its employees, agents, contractors, or assigns in the performance of the Agreement. Contractor shall correct any and all errors, omissions, discrepancies, ambiguities, mistakes or conflicts at no additional cost to the Owner. d. Contractor is an independent contractor of Owner. Any and all employees of the Contractor engaged by the Contractor in the performance of any work or services required of the Contractor under this Agreement, shall be considered employees or agents of the Contractor only and not of the Owner, and any and all claims that may or might arise under any workers compensation or other law or contract on behalf of said employees while so engaged shall be the sole obligation and responsibility of the Contractor. e. If activities related to the performance of this Agreement require specific licenses, DocuSign Envelope ID: 51195338-6F17-4D2B-B990-4A82329E7F4E Revised 07/20 3 certifications, or related credentials Contractor represents that it or its employees, agents and subcontractors engaged in such activities possess such licenses, certifications, or credentials and that such licenses certifications, or credentials are current, active, and not in a state of suspension or revocation. f. The Contractor is responsible for all physical damage to owned or rented machinery, tools, equipment, forms, and other items owned, rented or used by the Contractor and Subcontractor(s) in the performance of the Work including all of Owner’s property in Contractor’s care, custody, or control, and all such property while it is in transit. g. The Contractor is solely responsible for obtaining all permits necessary to complete the Work in compliance with all local, state, and federal laws. 5. PAYMENT & TAXES a. The Owner hereby agrees to pay to the Contractor for the faithful performance of this Agreement, and the Contractor hereby agrees to perform all of the Work for a sum not-to- exceed One Hundred Sixty Three Thousand, Nine Hundred Fifty-Two Dollars ($163,952.00). Not later than the fifth (5th) day of each calendar month the Contractor shall submit to the Owner’s Representative, generally the architect if an architect is retained on the Work, a Request for Payment for work done during the previous calendar month. i. The Request for Payment shall be in form of a standardized invoice or AIA Document G702-703 appropriately addressed to Owner’s Representative at 4600 Lake Boone Trail, Suite 205, Raleigh, NC 27607 and shall show substantially the value of work done during the previous calendar month. ii. The amount due for payment shall be ninety-five percent (95%) of the value of work completed since the last Request for Payment and this amount shall be paid by the Owner on or before the last business day of the month. Owner shall retain five percent (5%). 1. Upon Owner’s Representative’s certification that ninety percent (90%) of the Work has been satisfactorily completed retainage may be discontinued. Retainage may be discontinued, at Owner’s Discretion, so long as work continues to be completed satisfactorily and on schedule. iii. Final payment shall not be due to the Contractor until thirty (30) days after one hundred percent (100%) of the Work, including punch list work, has been satisfactorily (as determined by the County) completed and an appropriate affidavit as required in Section 7(c) below has been received by Owner. b. Should Owner reasonably determine that Contractor has failed to perform the Work related to a Request for Payment, Owner, at its discretion may provide the Contractor ten (10) days to cure the breach. Owner may withhold the accompanying payment without penalty until such time as Contractor cures the breach. i. Should Contractor or its representatives fail to cure the breach within ten (10) days, or fail to reasonably agree to such modified schedule, Owner may immediately terminate this Agreement in writing, without penalty or incurring further obligation to Contractor. ii. This section shall not be interpreted to limit the definition of breach to the failure to perform the Work related to a Request for Payment. DocuSign Envelope ID: 51195338-6F17-4D2B-B990-4A82329E7F4E Revised 07/20 4 c. The Contractor has included in the Contract Price and shall pay all taxes assessed by any authority on the Work or the labor and materials used therein. It shall be the Contractor's responsibility to furnish the Owner documentary evidence showing the materials used and sales and use tax paid by the Contractor and each of its subcontractors. 6. INSURANCE AND BONDS a. Minimum requirements – Contractor shall obtain, at its sole expense, Commercial General Liability Insurance, Automobile Insurance, Workers’ Compensation Insurance, and any additional insurance as may be required by Owner’s Risk Manager as such insurance requirements are described in the Orange County Risk Transfer Policy and Orange County Minimum Insurance Coverage Requirements (each document is incorporated herein by reference and may be viewed at http://www.orangecountync.gov/departments/purchasing_division/contracts.php). If Owner’s Risk Manager determines additional insurance coverage is required such additional insurance shall be designated here N/A (if no additional insurance required mark N/A as being not applicable). Contractor shall not commence construction work until such insurance is in effect and certification thereof has been received by the Owner's Risk Manager. b. Performance Bonds – Contractor shall furnish bonds covering the faithful performance of the Contract and payment of all obligations arising under any of the Contract Documents or related in any way to the Work. Contractor shall immediately furnish a copy of such bonds to any requesting person who appears to be a potential beneficiary of bonds covering payment obligations arising under any of the Contract Documents. This subsection 6(b) applies only to Contracts of fifty thousand dollars ($50,000.00) or more where the total cost for the project is three hundred thousand dollars ($300,000.00) or more. 7. INDEMNITY a. To the extent authorized by North Carolina law the Contractor shall indemnify, without limitation, and hold harmless to the maximum extent permitted by law the Owner and its agents and employees from and against any and all claims, damages, losses and expenses, including attorney's fees, arising out of or resulting from the performance or nonperformance of the Work, provided that any such claim, damages, loss or expense (A) is attributable to bodily injury, sickness, disease or death or injury to, or destruction of, property, including the loss of use resulting therefrom; and (B) is caused in whole or in part by any breach of any provision of the Agreement or by any negligent or wrongful act or omission of the Contractor, any Subcontractor, or supplier of the Contractor, anyone directly or indirectly employed by any of them or anyone for whose acts any of them may be liable. The indemnification obligation under this paragraph shall not be limited in any way by any limitation of the amount or type of damages, compensation or benefits payable by or for the Contractor or any subcontractor under workers' compensation acts, disability benefits acts or other employee benefit acts. It is the intent of this section that the Contractor shall indemnify the County to the maximum extent allowed by law. b. The Contractor shall indemnify and hold harmless Owner from any lien of whatever type through the purchase of appropriate bonds and insurance as designated in Section 6 above. In the event any such lien is filed against Owner’s property Contractor shall, through such DocuSign Envelope ID: 51195338-6F17-4D2B-B990-4A82329E7F4E Revised 07/20 5 bonds and insurance or at Contractors expense, defend Owner against all such claims of lien. c. Upon completion of the Work the Contractor shall execute an affidavit stating there are no unpaid debts for any work that has been done or materials that have been furnished to the project prior to and as of the date of substantial completion and further stating that Contractor shall indemnify, save and protect Owner and Owner’s lender, if any, harmless from and against any and all claims, liabilities, losses, damages, causes of action, and expenses (including court costs and reasonable attorney’s fees related thereto) arising out of, in connection with, or resulting from any such debts and liens. Such indemnification shall be in a form and substance acceptable to Owner. d. By executing this Agreement Contractor agrees to abide by and be bound by the indemnification provisions herein and of Section 7(c) specifically. 8. DISPUTE RESOLUTION AND GOVERNING LAW a. Any dispute with respect to any provision of, or the performance or non-performance of, this Agreement shall be subject to the Dispute Resolution Rules and Procedures for Orange County Design, Building Construction, Renovation, and Repair Projects. The policy is incorporated herein by reference and may be viewed at http://www.orangecountync.gov/departments/purchasing_division/contracts.php). b. The laws of the State of North Carolina shall apply to the interpretation and enforcement of this Agreement. Any and all suits or actions to enforce, interpret or seek damages with respect to any provision of, or the performance or nonperformance of, this Agreement or the Contract shall be brought in the General Court of Justice of North Carolina sitting in Orange County, North Carolina and it is agreed by the parties that no other court shall have jurisdiction or venue with respect to such suits or actions. c. Notice of any claim by Owner or Contractor must be initiated by written notice to the other Party within thirty (30) days of the occurrence of the event giving rise to the claim or within thirty (30) days of the discovery of the event or condition giving rise to the claim, whichever is later. i. Should any claim be made, regardless of whether such claim is made by Owner or Contractor, Contractor shall continue to faithfully and diligently perform the Work in such a manner as to meet all scheduled timelines. Any failure to faithfully and diligently perform the Work may be deemed, by the Owner, a breach of t he Contract. ii. If a claim is made such claim shall be made to the initial decision maker, if applicable, who may request more supporting data, reject the claim in whole or in part, approve the claim in whole or in part or advise the parties the claim is unab le to be resolved. iii. If a claim is made by the Owner the Owner may, but is not obligated to, notify the surety. 9. NON–APPROPRIATION a. Contractor acknowledges that Owner is a governmental entity, and the validity of this Agreement is based upon the availability of public funding under the authority of its statutory mandate. DocuSign Envelope ID: 51195338-6F17-4D2B-B990-4A82329E7F4E Revised 07/20 6 b. In the event that public funds are unavailable and not appropriated for the performance of Owner’s obligations under this Agreement, then this Agreement shall automatically expire without penalty to Owner immediately upon written notice to Contractor of the unavailability and non-appropriation of public funds. It is expressly agreed that Owner shall not activate this non-appropriation provision for its convenience or to circumvent the requirements of this Agreement, but only as an emergency fiscal measure during a substantial fiscal crisis. c. In the event of a change in the Owner’s statutory authority, mandate or mandated functions, by state or federal legislative or regulatory action, which adversely affects Owner’s authority to continue its obligations under this Agreement, then this Agreement shall automatically terminate without penalty to Owner upon written notice to Contractor of such limitation or change in Owner’s legal authority. 10. NOTICES Any notice required by this Agreement shall be in writing and delivered by certified or registered mail, return receipt requested to the following: Owner: Contractor: Orange County Carolina Contracting & Investments, Inc. Attn: AMS Attn: Robert Wise P.O. Box 8181 1632 Village Harbor Dr., 2nd Floor Hillsborough, NC 27278 Lake Wylie, SC 29710 11. MISCELLANEOUS a. Duties and Obligations imposed by the Contract Documents shall be in addition to any Duties and Obligations imposed by state, federal or local law, rules, regulations and ordinances. b. No act or failure to act by the Owner or Contractor shall constitute a waiver of any right or duty granted them under the Contract Documents, nor shall any act or failure to act constitute any approval except as specifically agreed in writing. c. The Work shall be tested and inspected as required by the Contract Documents and as required by law. Unless prohibited by law the costs of all such tests and inspections related to state and federal codes such as ADA, Administrative, Electrical, Plumbing, Mechanical and Building Codes shall be borne by the Contractor. The costs for material and structural testing shall be conducted by an independent third party at the expense of the Owner. Delays related to any of the aforementioned tests and inspections shall not be grounds for delaying the completion of the work. If any such tests and inspections reveal deficiencies in the Work such that the Work does not comply with terms or requirements of the Contract Documents and the requirements of any code or law the Contractor is solely responsible for the cost of bringing such deficiencies into compliance with the terms of the Contract Documents and any code or law. d. Should the Architect, if an architect is retained for the project involving the Work, or Owner reject any portion of the Work for failing to comply with the Contract Documents Contractor shall immediately, at Contractor’s expense, correct the Work. Any such DocuSign Envelope ID: 51195338-6F17-4D2B-B990-4A82329E7F4E Revised 07/20 7 rejection may be made before or after substantial completion. If applicable, any additional expense borne by the Architect under this section shall be paid at Contractor’s expense. e. The Contractor shall not assign any portion of this Agreement nor subcontract the Work in its entirety without the prior written consent of the Owner. f. By executing this Agreement Contractor affirms that Contractor and any subcontractors of Contractor are and shall remain in compliance with Article 2 of Chapter 64 of the North Carolina General Statutes. g. By executing this Agreement Contractor certifies that Contractor has not been identified, and has not utilized the services of any agent or subcontractor identified, on the list created by the State Treasurer pursuant to G.S. 147-86.58. h. By executing this Agreement Contractor certifies that Contractor has not been identified, and has not utilized the services of any agent or subcontractor identified, on the list created by the State Treasurer pursuant to G.S. 147-86.81. i. The County has designated (Angel Barnes) to act as the County's representative with respect to the Work and shall have the authority to render decisions within guidelines established by the County Manager or the County Board of Commissioners and shall be available during working hours as often as may be reasonably required to render decisions and to furnish information. j. Contractor shall at all times remain in compliance with all applicable local, state, and federal laws, rules, and regulations including but not limited to all state and federal non- discrimination laws, policies, rules, and regulations and the Orange County Non- Discrimination Policy and Orange County Living Wage Policy (each policy is incorporated herein by reference and may be viewed at http://www.orangecountync.gov/departments/purchasing_division/contracts.php). Any violation of the Orange County Non-Discrimination Policy is a breach of this Agreement and County may immediately terminate this Agreement without further obligation on the part of the County. This paragraph is not intended to limit and does not limit the definition of breach to discrimination. k. This Agreement together with any amendments or modifications may be executed electronically. All electronic signatures affixed hereto evidence the consent of the Parties to utilize electronic signatures and intent of the Parties to comply with Article 11A and Article 40 of North Carolina General Statute Chapter 66. l. In the event of a breach by Contractor Owner has sole authority to determine the reasonableness of Contractor’s actions to remedy such breach or complete the performance of its obligations. m. Upon request of the Owner, the Contractor shall submit to County all relevant documentation, including but not limited to, job cost records, to support its claims for final compensation and if such request is made final compensation shall not be due until all relevant documentation is received, reviewed, and approved by Owner. DocuSign Envelope ID: 51195338-6F17-4D2B-B990-4A82329E7F4E Revised 07/20 8 12. CONSEQUENTIAL AND LIQUIDATED DAMAGES a. Owner and Contractor mutually waive any claim against each other for consequential damages. Consequential Damages include: i. Damages incurred by Owner for loss of use, income, financing, or business. ii. Damages incurred by Contractor for office expenses, including personnel, loss of financing, profit, income, business, damage to reputation, or any other non-direct damages. b. Liquidated damages shall be in accord with the Contract Documents. If the Contract Documents do not otherwise address liquidated damages, such damages shall be in the amount of five hundred dollars ($500.00) per day. 13. TERMINATION OR SUSPENSION a. The Owner may, without cause, order the Contractor to terminate, suspend, delay or interrupt the Work in whole or in part for such period of time as the Owner may determine. i. If Owner issues a written order to delay, suspend, or interrupt the Work, and such order is not due to or as a result of an y fault on the part of the Contractor or any subcontractor, the Contractor may recover a per diem amount of five hundred dollars ($500.00) per day with a not-to-exceed limit of ten thousand dollars ($10,000.00). ii. In the event of termination by the Owner under this Agreement, the Contractor shall be entitled to receive its reasonable and documented direct costs prior to termination, including the cost of materials purchased for the Work which purchases cannot be canceled or which material cannot reasonably be used by the Contractor on other work, and the cost of closing down the work in a safe and efficient manner. iii. If Owner elects to suspend or terminate the contract pursuant to subparagraphs 13.a.i. or 13 a.ii. the sole remedy available to the Contractor are those listed in the subparagraphs and Contractor is not entitled to any right to further claims for any amount owed or disputed or for payment of damages alleged to have been sustained as a result of Owner’s order to delay, suspend, or interrupt the Work. b. The Owner may, with cause, order the Contractor to suspend, delay or interrupt the Work in whole or in part for such period of time as the cause remains. i. If Owner issues a written order to delay, suspend, or interrupt the Work, and such order is due to or as a result of any fault on the part of the Contractor or any subcontractor, the Owner may reduce payment at a per diem amount of five hundred dollars ($500.00) per day. c. Contractor may terminate the Contract if, at the Owner’s written direction, the Work is stopped for twenty one (21) consecutive days through no act or fault of the Contractor, their agents or employees, or a subcontractor or their agents or employees or any other person performing work pursuant to the Contract Documents. Contractor may terminate DocuSign Envelope ID: 51195338-6F17-4D2B-B990-4A82329E7F4E Revised 07/20 9 the Contract if a Court or other Public authority having jurisdiction enters a lawful order that requires all work to be stopped and such stoppage lasts for twenty one (21) consecutive days. d. Either party may terminate this Agreement upon notice to the other party that obligations pursuant to this Agreement are made impossible due to declarations of emergency by Orange County or by North Carolina due to events directly impacting Orange County. Both parties shall remain responsible for all payment and performance due up to the receipt of such notice, but shall have no further obligation or responsibility beyond that date provided the terminating party has taken all reasonable steps to complete the performance of its obligations. 14. ENTIRE AGREEMENT All of the documents listed, referenced or described in this Agreement, the written Notice-to- Proceed, together with Modifications made or issued in accordance herewith are the Contract Documents, and the work, labor, materials and completed construction required by the Contract Documents and all parts thereof is the Work. The Contract Documents constitute the entire agreement between Owner and Contractor. This Agreement may be amended only by written instrument signed by both parties. Modifications may be evidenced by facsimile signatures. If any provision of the Agreement shall be declared invalid or unenforceable, the remainder of the Agreement shall continue in full force and effect. IN WITNESS WHEREOF, the Parties hereto have executed this Agreement as of the day and date first above written wholly or in a number of counterparts each of which shall, without proof or accounting for other counterparts, be deemed an original contract. ORANGE COUNTY CONTRACTOR ____________________________________ ________________________________________ Signature Signature County Manager ________________________________________ Printed Name and Title DocuSign Envelope ID: 51195338-6F17-4D2B-B990-4A82329E7F4E President 10/19/2020 Glenn Wise 10/20/2020 Revised 07/20 10 ORANGE COUNTY—DEPARTMENT USE ONLY ______________________________________________________________________________ Party/Vendor Name: Carolina Contracting & Investments, Inc. Party/Vendor Contact Person: Glenn Wise (President) and Justin Nicholson (jnicholson@carolinaci.com) Contact Phone: 704.499.4501 Party/Vendor Address: 1632 Village Harbor Dr. 2nd Floor City Lake Wylie State: SC Zip: 29710 Department: AMS Amount: $163,952.00 Purpose: Hillsborough Commons - Replace Skylights Budget Code(s): 61370035-882000-30002 Vendor # 66717 (N/A if new vendor) Vendor is a BOCC consultant? Yes No Contract Type: (Check one) New Renewal Amendment Effective Date 10/26/2020 Approved by Board Yes No Agenda Date: N/A This agreement is approved as to technical form and content and I as Department Director affirmatively state work on this project has not been initiated prior to execution of the agreement: Department Director’s Signature ________________________________________ Date: ________ Agreements for emergency services or repair are not subject to the above affirmation. If services related to this agreement have already begun or been completed please briefly describe the nature of the emergency condition that was addressed: N/A Risk Management This agreement is approved for sufficiency of insurance standards, specifications, and requirements: Office of the Risk Management Officer___________________________________ Date: _________ Financial Services This instrument has been pre-audited in the manner required by the Local Government Budget and Fiscal Control Act: Office of the Chief Financial Officer ____________________________________ Date: _________ Legal Services This agreement is approved as to legal form and sufficiency: Office of the County Attorney __________________________________________Date: ________ Clerk to the Board Received for record retention: All Docusign contracts must be copied to the Clerk upon completion: occlerkdocs@orangecountync.gov The following signature block is for hard copies only and is not required for Docusign contracts: Office of the Clerk to the Board __________________________________________Date:_________ DocuSign Envelope ID: 51195338-6F17-4D2B-B990-4A82329E7F4E 10/19/2020 10/19/2020 10/20/2020 10/20/2020 DocuSign Envelope ID: 51195338-6F17-4D2B-B990-4A82329E7F4E DocuSign Envelope ID: 51195338-6F17-4D2B-B990-4A82329E7F4E DocuSign Envelope ID: 51195338-6F17-4D2B-B990-4A82329E7F4E DocuSign Envelope ID: 51195338-6F17-4D2B-B990-4A82329E7F4E DocuSign Envelope ID: 51195338-6F17-4D2B-B990-4A82329E7F4E 10/13/2020 Sifford-Stine Insurance 214 South Main Street P O Box 597 Clover SC 29710 Kimberly Stone (803) 222-9468 (803) 222-7616 kstone@sifford-stine.com Carolina Contracting And Investment Inc. 935 Thorn Ridge Ln Lake Wylie SC 29710 Ohio Security 24082 Ohio Casualty Ins Co 24074 2021 Master A Y BKS59800728 06/29/2020 06/29/2021 1,000,000 300,000 15,000 1,000,000 2,000,000 2,000,000 CSCHD A Y BAS59800728 06/29/2020 06/29/2021 1,000,000 Underinsured motorist combined single limit 1,000,000 B 0 Y USO59800728 06/29/2020 06/29/2021 2,000,000 2,000,000 A N XWS59800728 04/25/2020 04/25/2021 1,000,000 1,000,000 1,000,000 A Rented/Leased Equipment BKS59800728 06/29/2020 06/29/2021 BLANKET UP TO 25,000 Orange County is additional insured when required by written contract. Orange County PO Box 8181 Hillsborough NC 27278 SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. INSURER(S) AFFORDING COVERAGE INSURER F : INSURER E : INSURER D : INSURER C : INSURER B : INSURER A : NAIC # NAME:CONTACT (A/C, No):FAX E-MAILADDRESS: PRODUCER (A/C, No, Ext):PHONE INSURED REVISION NUMBER:CERTIFICATE NUMBER:COVERAGES IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. OTHER: (Per accident) (Ea accident) $ $ N / A SUBR WVD ADDL INSD THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. $ $ $ $PROPERTY DAMAGE BODILY INJURY (Per accident) BODILY INJURY (Per person) COMBINED SINGLE LIMIT AUTOS ONLY AUTOSAUTOS ONLY NON-OWNED SCHEDULEDOWNED ANY AUTO AUTOMOBILE LIABILITY Y / N WORKERS COMPENSATION AND EMPLOYERS' LIABILITY OFFICER/MEMBER EXCLUDED? (Mandatory in NH) DESCRIPTION OF OPERATIONS below If yes, describe under ANY PROPRIETOR/PARTNER/EXECUTIVE $ $ $ E.L. DISEASE - POLICY LIMIT E.L. DISEASE - EA EMPLOYEE E.L. EACH ACCIDENT EROTH-STATUTEPER LIMITS(MM/DD/YYYY)POLICY EXP(MM/DD/YYYY)POLICY EFFPOLICY NUMBERTYPE OF INSURANCELTRINSR DESCRIPTION OF OPERATIONS / LOCATIONS / VEHICLES (ACORD 101, Additional Remarks Schedule, may be attached if more space is required) EXCESS LIAB UMBRELLA LIAB $EACH OCCURRENCE $AGGREGATE $ OCCUR CLAIMS-MADE DED RETENTION $ $PRODUCTS - COMP/OP AGG $GENERAL AGGREGATE $PERSONAL & ADV INJURY $MED EXP (Any one person) $EACH OCCURRENCE DAMAGE TO RENTED $PREMISES (Ea occurrence) COMMERCIAL GENERAL LIABILITY CLAIMS-MADE OCCUR GEN'L AGGREGATE LIMIT APPLIES PER: POLICY PRO-JECT LOC CERTIFICATE OF LIABILITY INSURANCE DATE (MM/DD/YYYY) CANCELLATION AUTHORIZED REPRESENTATIVE ACORD 25 (2016/03) © 1988-2015 ACORD CORPORATION. All rights reserved. CERTIFICATE HOLDER The ACORD name and logo are registered marks of ACORD HIRED AUTOS ONLY DocuSign Envelope ID: 51195338-6F17-4D2B-B990-4A82329E7F4E Revised 11/19 ORANGE COUNTY NORTH CAROLINA DISPUTE RESOLUTION RULES AND PROCEDURES FOR ORANGE COUNTY DESIGN, BUILDING CONSTRUCTION, RENOVATION, AND REPAIR PROJECTS RULE 1. INITIATING MEDIATED SETTLEMENT CONFERENCES A. Purpose of Mandatory Settlement Conferences. Pursuant to G.S. §143-128(f1) and 143- 135.26(11), these Rules are promulgated to implement a mediated settlement program designed to focus the parties’ attention on settlement rather than on claim preparation and to provide an opportunity for orderly settlement negotiations to take place. Nothing herein is intended to limit or prevent the parties from engaging in settlement procedures voluntarily at any time prior to or during commencement of the dispute resolution process. B. Initiating the Dispute Resolution Process 1. Any party to a County public construction contract (referred to herein generally as the “Contract”) governed by Article 8. Ch. 143 of the General Statutes and identified in G.S. § 143- 128(f1) and who is a party to a dispute arising out of the Contract and the construction process in which the amount in controversy is at least $15,000 may submit a written request to the County for mediation of the dispute. 2. Prior to submission of a written request for mediation to the County, the party requesting mediation should give notice of any and all claims in accordance with their respective contracts, obtain decisions on the claims as required or allowed by their respective contracts, and attempt to resolve the dispute according to the terms and conditions in their respective contracts. The Mediator may adjourn any mediated settlement conference if the Mediator believes, in his or her sole discretion, that the parties have not satisfied all of the terms and conditions of their respective contracts and that doing so will enhance the prospects for a negotiated settlement. C. Condition Precedent to Litigation. Before any party to a Contract may commence a civil action against the County seeking remedies for breach or non-performance of the Contract by the County, said party must first initiate the dispute resolution process under these rules and attend and participate in good faith in the mediated settlement conference. RULE 2. SELECTION OF MEDIATOR A. Mediator Listing. A List of Mediators acceptable to the County is maintained by the County Attorney and that list is incorporated by reference into these Rules. B. Selection of Mediator. The party requesting mediation shall select a Mediator from the List of Mediators and shall file, with the County, a Notice of Selection of Mediator within 21 days of the request for mediation. Such notice shall state the name, address, and phone number of the Mediator selected. If DocuSign Envelope ID: 51195338-6F17-4D2B-B990-4A82329E7F4E Revised 11/19 the Mediator selected is not available or declines to participate for any reason, the requesting party shall select another person from the List of Mediators. If the party requesting mediation does not select and designate a mediator within 21 days of the request for mediation, the County shall have the right in its absolute discretion to appoint a mediator from its List of Mediators. C. Disqualification of Mediator. Any party may request replacement of the Mediator for good cause. Nothing in this provision shall preclude Mediators from disqualifying themselves. RULE 3. THE MEDIATED SETTLEMENT CONFERENCE A. Where Conference is to be Held. Unless all parties and the Mediator otherwise agree, the mediated settlement conference shall be held in county seat of Orange County. The Mediator shall be responsible for reserving a place, making arrangements for the conference, and giving timely notice of the time and location of the conference to all attorneys, unrepresented parties and other persons or entities required to attend. B. When Conference is to be Held. The mediation shall be completed within 90 days after selection of the Mediator unless all parties to the mediation agree to a different schedule. C. Request to Accelerate or Extend Deadline for Completion. Any party or the Mediator may request the County to accelerate or extend the deadline for completion of the conference. Such request shall state the reasons the acceleration or extension is sought and shall be served by the moving party upon the other parties and the Mediator. Objections to the request must be promptly communicated to the County and to the Mediator. The County, with the concurrence of the designated Mediator, may grant the request by adjusting the time for completion of the conference. D. Recesses. The Mediator may recess the mediation conference at any time and may set times for reconvening. If the Mediator determines the time and place where the conference is to reconvene before the conference is recessed, no further notice is required to persons present at the conference. E. Project Delay. The mediated settlement conference that results from a construction contract dispute shall not be cause for the delay of the construction project. RULE 4. DUTIES OF PARTIES AND OTHER PARTICIPANTS IN FORMAL DISPUTE RESOLUTION PROCESS A. Attendance. 1. All parties to the dispute must designate an official representative to attend the mediation. 2. “Attendance” means physical attendance, not by telephone or other electronic means. Any attendee representing a party must have authority from that party to bind it to any agreement reached as a result of the mediation. 3. Attorneys representing parties may attend the mediation, but are not required to do so. DocuSign Envelope ID: 51195338-6F17-4D2B-B990-4A82329E7F4E Revised 11/19 4. Sureties and insurance company representatives are required to physically attend the mediation unless the Mediator and all of the other parties to the mediation excuse their attendance or consent to their attendance by telephone or other electronic means. 5. The parties who attend a duly scheduled mediation conference shall have the right to recover their share of the Mediator’s compensation from any party or parties who fail to attend the conference without good cause. B. Finalizing Agreement. If an agreement is reached in the conference, the terms of the agreement shall be confirmed in writing and signed by all parties. C. Payment of Mediation Fee: Mediation Fees charged by the Mediator shall be paid in accordance with G.S. § 143-128(f1). D. Failure to Compensate Mediator. Any party’s failure to compensate the Mediators in accordance with G.S. § 143-128(f1) shall subject that party to a withholding by the County of said amount of money from the party’s payment or any other moneys owed by that party to the County. Should the County fail to compensate the Mediator, it shall hereby be subject to a civil cause of action from the Mediator for the County’s portion of the Mediator’s total fee as required by G.S. § 143-128(f1). RULE 5. AUTHORITY AND DUTIES OF MEDIATORS A. Authority of Mediator. 1.Control of Conference. The Mediator shall at all times be in control of the conference and the procedures to be followed. 2.Private Consultation. The Mediator may communicate privately with any participant or counsel prior to and during the conference. The fact that private communications have occurred with a participant shall be disclosed to all other participants at the beginning of the conference. 3.Scheduling the Conference. The Mediator shall make a good faith effort to schedule the conference at a time that is convenient with the participants, attorneys and Mediator. In the absence of agreement, the Mediator shall select the date for the conference. 4.Determining good cause for a party’s failure to appear at a scheduled mediation conference. B.Duties of Mediator. 1.The Mediator shall define and describe the following at the beginning of the conference: a.The process of mediation. b.The difference between mediation and other forms of conflict resolution. c.The costs of the mediated settlement conference. d.That the mediated settlement conference is not a trial, the Mediator is not a judge, and the parties retain their legal rights if they do not reach settlement; however, the DocuSign Envelope ID: 51195338-6F17-4D2B-B990-4A82329E7F4E Revised 11/19 Mediator will advise all parties that failure to appear at mediation without good cause may result in imposition of sanctions and may be asserted as a bar to lawsuits by claimants who have failed to exhaust this administrative remedy. e.The circumstances under which the Mediator may meet and communicate privately with any of the parties or with any other person. f.Whether and under what conditions communications with the Mediator will be held in confidence during the conference. g.The inadmissibility of conduct and statements as provided by G.S. §7A-38.1(1). h.The duties and responsibilities of the Mediator and the participants. i.That any agreement reached will be reached by mutual consent. 2. Disclosure: The Mediator has a duty to be impartial and to advise all participants of any possible bias, prejudice or partiality. 3. Declaring Impasse: The Mediator may determine at any time during the mediation conference that an impasse exists and that the conference should end. 4. Reporting Results of Conference. The Mediator shall submit a written report to the County and the other parties within 10 days of the conference stating whether or not the parties reached an agreement. The Mediator’s report shall indicate the absence of any party from the mediated settlement conference without permission or good cause. 5. Scheduling and Holding the Conference. It is the duty of the Mediator to schedule the conference and conduct it prior to the deadline of completion set by the rules. The Mediator shall strictly observe deadlines for completion of the conference unless said time limit is changed by agreement of the parties. RULE 6. COMPENSATION OF THE MEDIATOR The parties shall compensate the Mediator for mediation services at the rate proposed by the Mediator and agreed to by the parties at the time the Mediator is selected. RULE 7. RULE MAKING These Rules may be amended by the County at any time. Amendments will not affect mediations where claims and/or requests for mediation have been filed at the time the amendment takes effect. RULE 8. DEFINITIONS A. “County” shall mean Orange County North Carolina. B. “Project Designer” is that person or firm stipulated as project designer in the Contract Documents for the project. DocuSign Envelope ID: 51195338-6F17-4D2B-B990-4A82329E7F4E Revised 11/19 C. “Claim” is a demand or assertion by a party seeking adjustment or interpretation of Contract terms, payment of money, extension of time or other relief with respect to the terms of the Contract. The term “Claim” also includes other disputes and matters in question between the parties to a Contract involved in the County’s building construction renovation and repair projects arising out of or relating to the Contract or the construction process. Claims must be initiated by a written notice. The responsibility to substantiate Claims shall rest with the party making the Claim. D. “Good Cause” generally includes any circumstance beyond the control of a party, which prevents that party from meeting obligations. When good cause is asserted as an excuse for a party’s failure to appear at a mediation conference or to otherwise comply with the requirements of these Rules, the Mediator, in his or her sole discretion, will determine whether good cause exists to excuse the party’s failure to appear or otherwise comply with these rules. RULE 9. TIME LIMITS A. Any time limit provided for by these Rules may be waived or extended at the sole discretio n of the County, if no Mediator has been selected, and at the discretion of the County with concurrence of the Mediator if a Mediator has been selected. DocuSign Envelope ID: 51195338-6F17-4D2B-B990-4A82329E7F4E 2A2-03DETAIL NO.DRAWING NO.SHEET NO.1View Name1/8" = 1'-0"A1-01SYMBOL LEGENDSCALEDRAWING NAMESHEET NO.SECTION MARKELEVATION VALUEREFERENCE DESCRIPTION15' - 4"AFF2A2-03SHEET NO.DETAIL NO.A2-0322A2-03CALLOUT DETAILSHEET NO.DETAIL NO.EXTERIOR ELEVATION MARKINTERIOR ELEVATION MARKSHEET NO.DETAIL NO.CONTROL / ELEVATION MARK1' - 2"10"1' - 4 1/2"1' - 2"6A1-011' - 9"1' - 4"1' - 4"7 1/2"6A1-01A1-01236' - 2"6' - 1"6' - 2"6' - 1"73' - 0"6' - 1"6' - 2"6' - 1"A1-011A1-013A1-014ABCDEFGHISET ASET B6A1-016A1-01EXISTING ROOF AND STRUCTURENEW SKYLIGHTCOMPRESSION MOUNTED ALUMINUMFRAMING FOR SKYLIGHT SCREENSTAINLESS STEEL SKYLIGHTPROTECTION SCREENEXISTING BASE FLASHINGNEW STAINLESS STEEL TWO-PIECE COUNTERFLASHING FASTENED 8" O.C. W/ NEOPRENE WASHERSPROVIDE NEW TERMINATION BAR FASTENED @ 8" OC MAX. THROUGH BUTYL TAPECONT. SEALANT ALONG TOP OF TERM. BAR2 1/2"3"PROVIDE FULLY ADHERED MEMBRANE FLASHING BENEATH METAL COUNTERFLASHING EXTENDING FROM BASE FLASHING OVER TOP OF CURBEXISTING KNEE WALL CURB TO REMAIN. DRAWN BY:CHECKED BY:ofDESCRIPTIONDATEIDT 919 781 8582F 919 781 39794600 Lake Boone TrailSuite 205Raleigh, NC 27607info@smithsinnett.comThis drawing and the design shown is the property of Smith Sinnett Architecture, P.A. the reproduction or use of this property without the written consent of the Architect is prohibited. Any infringement of the ownership rights will be subject to legal action. All copies of this drawing must be returned to the Architect at the completion of the contract.Smith Sinnett Architecture, P.A. 2020THIS DRAWING IS FORMATTED TO BE PRINTED ON A 24" X 36" SHEETF:\2020054 Hillsborough Commons Skylights\2-Drawings\2020054 Hillsborough Commons Skylights_Arch.rvt6/17/2020 11:34:47 PMA1-01SKYLIGHTREPLACEMENTDW201905416 JUNE 2020RACONSTRUCTION DOCUMENTS##30Orange County NCHillsborough Commons Skylight Replacement133 Mayo St. Hillsborough, NC 27278Hillsborough Commons Skylight Replacement133 Mayo St. Hillsborough, NC 27278Orange County NCREGISTEREDARCHITECTURALCORPORATIONNORTHCAROLINAARCHITECTU,PARALEIGH50172CERT. NO.RESINETTNSMIHTCONTACTS1/4" = 1'-0"A1-011SKYLIGHT SET A - SIDE ELEVATION1/4" = 1'-0"A1-012SKYLIGHT SET A - WEST END ELEVATION1/4" = 1'-0"A1-013SKYLIGHT SET B - SIDE ELEVATION1/4" = 1'-0"A1-014SKYLIGHT SET B - WEST END ELEVATION1/8" = 1'-0"A1-015ROOF PLANARCHITECTURE:SMITH SINNETT ARCHITECTURE4600 LAKE BOONE TRAIL, SUITE 205RALEIGH, NC 27607919.781.8582 (P)919.781.3979 (F)POC: Drew Wilgusdwilgus@smithsinnett.comOWNERORANGE COUNTY, NC131 MARGARET LANEHILLSBOROUGH, NC 27278910.610.8182 (P)POC: Angel Barnes, Asset Managementabarnes@orangecountync.govABCDEFGHIPROJECT NOTES1. ALL DIMENSIONS SHOWN ARE FOR PRICING PURPOSES, OPENING DIMENSIONS ARE TO BE MEASURED AND VERIFIED FOR COORDINATION WITH THE SYSTEM PROVIDED.2. THE EXISTING ROOF IS A RECENTLY REPLACED SHEET ASPHALT ROOFING. THE ROOF IS TO BE PROTECTED AT ALL TIMES. DAMAGE RESULTING FROM SKYLIGHT CONSTRUCTION ACTIVITY WILL BE THE RESPONSIBILTY OF THE CONTRACTOR.3. EXISTING SKYLIGHTS ARE TO BE REMOVED IN THEIR ENTIRETY. CONTRACTOR SHALL ALERT THE OWNER OF ANY PREEXISTING DAMAGE TO INTERIOR FINISHES OR STRUCTURAL ELEMENTS RESULTING FROM WATER INTRUSION. 4. AREA PREP: BASE FLASHING IS TO BE CUT NEATLY AS SHOWN IN THE DETAIL. CURB TOP IS TO CLEANED AND STRIPPED OF ANY MATERIAL THAT MAY INTERFERE WITH A PROPERLY SEATED GLAZING UNIT. CURB AND MEMBRANE ARE TO BE PREPPED AS REQUIRED TO ACHEIVE A FULLY WARANTED AND WEATHER-TIGHT SYSTEM. 5. THE BUILDING WILL BE OCCUPIED THROUGHOUT THE CONSTRUCTION PERIOD. THE CONTRACTOR AND SUBCONTRACTOR(S) ARE TO EXERCISE PROPER CONDUCT AND SAFETY.3" = 1'-0"A1-016TYPICAL CROSS SECTIONSPECIFICATION NOTES1. BASIS OF DESIGN: WASCO SKLIGHTS -PLASTIC GLAZE THERMALIZED BARREL VAULT SKYLIGHTS2. CLASS 1 CLEAR ANNODIZED FINISH WITH INSULATED ACRYLIC PANELS. 3. STAINLESS STEEL FALL PROTECTION SAFETY SCREEN4. EQUAL PRODUCTS MAY BE SUBMITTED TO THE ARCHTIECT FOR APPROVAL NO LATER THAN 5 DAYS PRIOR TO BIDEXISTING CONDITIONSREFER TO COMPLETE PROJECT MANUAL FOR FULL DETAILS AND REQUIREMENTS.DocuSign Envelope ID: 51195338-6F17-4D2B-B990-4A82329E7F4E OC DSS -Hillsborough Commons Skylight Replacement Smith Sinnett / 2020054 Hillsborough, NC Orange County NON PERMEABLE AIR AND VAPOR BARRIERS 07 27 00 - 1 SECTION 07 27 00 – NON PERMEABLE AIR AND VAPOR BARRIERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section. 1.2 SUMMARY A. This Section includes the following: 1. Fluid-applied non permeable air and vapor barrier membrane. 2. Self-adhered non permeable air and vapor barrier membrane. B. Related Sections include the following: 1. Division 04 Section "Unit Masonry" for embedded flashings. 2. Division 09 Section "Gypsum" for wall sheathings, and wall sheathing. 3. Division 07 low-slope roofing Sections for roof air barriers. 4. Division 07 Section "Thermal Insulation" for insulation. 5. Division 07 Section "Sheet Metal Flashing and Trim" for sheet metal flashings. 6. Division 07 Section "Joint Sealants" for joint-sealant materials and installation. 1.3 REFERENCES A. The following standards are applicable to this section: 1. ASTM E2178: Standard Test Method for Air Permeance of Building Materials. 2. ASTM E283: Standard Test Method for Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen. 3. ASTM E330: Standard Test Method for Structural Performance of Exterior Windows, Curtain Walls, and Doors by Uniform Static Air Pressure Difference. 4. ASTM E331: Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference 5. ASTM E96: Water Vapor Transmission of Materials. 6. CGSB 37-GP-56M: Membrane, Modified, Bituminous, Prefabricated, and Reinforced. 1.4 DEFINITIONS A. ABAA: Air Barrier Association of America. B. Air Barrier Assembly: The collection of air barrier materials and auxiliary materials applied to an opaque wall, including joints and junctions to abutting construction, to control air movement through the wall. 1.5 PERFORMANCE REQUIREMENTS A. General: Air barrier shall be capable of performing as a continuous vapor non permeable air barrier and as a liquid-water drainage plane flashed to discharge to the exterior incidental condensation or water penetration. Air barrier assemblies shall be capable of accommodating substrate movement and of sealing substrate expansion and control joints, construction material changes, and transitions at perimeter conditions without deterioration and air leakage exceeding specified limits. DocuSign Envelope ID: 51195338-6F17-4D2B-B990-4A82329E7F4E OC DSS -Hillsborough Commons Skylight Replacement Smith Sinnett / 2020054 Hillsborough, NC Orange County NON PERMEABLE AIR AND VAPOR BARRIERS 07 27 00 - 2 B. Air Barrier Assembly Air Leakage: Not to exceed ASTM E 283. 1.6 SUBMITTALS A. Product Data: Include manufacturer's written instructions for evaluating, preparing, and treating substrate; technical data; and tested physical and performance properties of air barrier. B. Shop Drawings: Show locations and extent of air barrier. Include details for substrate joints and cracks, counterflashing strip, penetrations, inside and outside corners, terminations, and tie-ins with adjoining construction. 1. Include details of interfaces with other materials that form part of air barrier. 2. Include details of mockups. C. Product Certificates: For air barriers, certifying compatibility of air barrier and accessory materials with Project materials that connect to or that come in contact with the barrier; signed by product manufacturer. D. Qualification Data: For Applicator. E. Product Test Reports: Based on evaluation of comprehensive tests performed by a qualified testing agency, for air barriers. 1.7 QUALITY ASSURANCE A. Submit document stating the applicator of the primary air/vapor barrier membranes specified in this section is qualified by the manufacturer as suitable for the execution of the Work. B. Applicator Qualifications: A firm experienced in applying air barrier materials similar in material, design, and extent to those indicated for this Project, whose work has resulted in applications with a record of successful in-service performance and that is an ABAA-licensed contractor, employs certified and registered installers, and complies with ABAA's Quality Assurance Program. C. Components used shall be sourced from one manufacturer, including sheet membrane, air barrier sealants, primers, mastics, and adhesives. D. Single-Source Responsibility: 1. Obtain air barrier materials from a single manufacturer regularly engaged in manufacturing the product. 2. Provide products which comply with all state and local regulations controlling use of volatile organic compounds (VOCs). E. Mockups: Before beginning installation of air barrier, build mockups of exterior wall assembly incorporating backup wall construction, external cladding, window, door frame and sill, insulation, and flashing to demonstrate surface preparation, crack and joint treatment, and sealing of gaps, terminations, and penetrations of air barrier membrane. 1. Coordinate construction of mockup to permit inspection by Owner's testing agency of air barrier before external insulation and cladding is installed. 2. Include junction with roofing membrane, building corner condition, and foundation wall intersection. 3. If Architect determines mockups do not comply with requirements, reconstruct mockups and apply air barrier until mockups are approved. 4. Approved mockups may become part of the completed Work if undisturbed at time of Substantial Completion. F. Preinstallation Conference: Conduct conference at Project site. 1. Include installers of other construction connecting to air barrier, including roofing, waterproofing, architectural precast concrete, masonry, sealants, windows, glazed curtain walls, and door frames. 2. Review air barrier requirements including surface preparation, substrate condition and pretreatment, minimum substrate curing period, forecasted weather conditions, special details and sheet flashings, mockups, installation procedures, sequence of installation, testing and inspecting procedures, and protection and repairs. DocuSign Envelope ID: 51195338-6F17-4D2B-B990-4A82329E7F4E OC DSS -Hillsborough Commons Skylight Replacement Smith Sinnett / 2020054 Hillsborough, NC Orange County NON PERMEABLE AIR AND VAPOR BARRIERS 07 27 00 - 3 1.8 DELIVERY, STORAGE, AND HANDLING A. Store liquid materials in their original undamaged packages in a clean, dry, protected location and within temperature range required by air barrier manufacturer. B. Remove and replace liquid materials that cannot be applied within their stated shelf life. C. Protect stored materials from direct sunlight. D. Store role materials on end in original packaging. Protect rolls from direct sunlight until ready for use. E. Store air barrier membranes, adhesives and primers at temperatures of 40 degrees F and rising. F. Keep solvent away from open flame or excessive heat. 1.9 PROJECT CONDITIONS A. Environmental Limitations: Apply air barrier within the range of ambient and substrate temperatures recommended by air barrier manufacturer. Protect substrates from environmental conditions that affect performance of air barrier. Do not apply air barrier to a damp or wet substrate or during snow, rain, fog, or mist. 1.10 WARRANTY A. Provide manufacturer’s standard 10-year material warranty. PART 2 - PRODUCTS 2.1 FLUID-APPLIED MEMBRANE AIR AND VAPOR BARRIER A. Fluid-Applied, Vapor Non Permeable Membrane Air Barrier: Basis of Design shall be Air-Bloc 06WB by Henry; a one component elastomeric asphalt emulsion, trowel or spray applied, compatibility with substrates and transition membranes. 1. Available Products: Subject to compliance with requirements, products that may be incorporated into the Work include, but are not limited to, the following: a. Elastomeric Modified Bituminous Membrane: 1) Carlisle Coatings & Waterproofing; Barriseal. 2) Henry Company; Air-Bloc 06wb. 3) Meadows, W. R., Inc.; Air-Shield LM. 4) NEI; AC 5) Tremco Incorporated; ExoAir. 2. Physical and Performance Properties: a. Air permeability: 0.001 CFM/ft2 @ 1.6 lbs/ft2. to ASTM E2178 and ASTM E283 and have no increased air leakage when subjected to a sustained wind load of 10.5 lbs/ft2 for 1 hour and gust wind load pressure of 62.8 lbs/ft2 for 10 seconds when tested at 1.6 lbs/ft2 to ASTM E331 b. Water vapor permeance: 0.02 perms to ASTM E96 c. Wet Film Thickness: 90 mils d. Elongation: 2000% to ASTM D 412 2.2 SELF-ADHERING SHEET AIR AND VAPOR BARRIER A. Modified Bituminous Sheet: Basis of Design shall be Blueskin SA manufactured by Henry; an SBS modified bitumen, self-adhering sheet membrane complete with a thermoplastic film. DocuSign Envelope ID: 51195338-6F17-4D2B-B990-4A82329E7F4E OC DSS -Hillsborough Commons Skylight Replacement Smith Sinnett / 2020054 Hillsborough, NC Orange County NON PERMEABLE AIR AND VAPOR BARRIERS 07 27 00 - 4 1. Available Products: Subject to compliance with requirements, products that may be incorporated into the Work include, but are not limited to, the following: a. Carlisle Coatings & Waterproofing; CCW-705. b. Grace, W. R. & Co.; Perm-A-Barrier. c. Henry Company; Blueskin SA. d. Meadows, W. R., Inc.; SealTight Air-Shield. e. NEI; AC AirSeal. f. Rubber Polymer Corporation; Rub-R-Wall SA. g. Tremco, Incorporated; ExoAir 110 2. Physical and Performance Properties: a. ASTM E2357: Standard Test Method for Determining Air Leakage of Air Barrier Assemblies, b. Air leakage: <0.0001 CFM/ft² @1.6 lbs/ft2 to ASTM E2178 and ASTM E283 and have no increased air leakage when subjected to a sustained wind load of 10.5 lbs/ft2 for 1 hour and gust wind load pressure of 62.8 lbs/ft2 for 10 seconds when tested at 1.6 lbs/ft2 to ASTM E331, c. Vapor permeance: 0.03 perms to ASTM E96 (Desiccant Method), d. Membrane Thickness: 0.0394 inches (40 mils), e. Low temperature flexibility: -22 degrees F to CGSB 37-GP-56M, f. Elongation: 200% to ASTM D412-modifed, g. Meets CAN/CGSB-51-33 Type I Water Vapor Permeance requirements 2.3 PRIMERS A. Primer for self-adhering membranes at temperatures above 25 degrees F shall be Aquatac Primer manufactured by Henry or equal; a polymer emulsion based adhesive, quick setting. Primer shall have the following physical properties: 1. Weight: 8.7 lbs/gal, 2. Solids by weight: 53%, 3. Water based, no solvent odors, 4. Drying time (initial set): 30 minutes at 50% RH and 70 degrees F B. Adhesive for self-adhering membranes at all temperatures shall be Blueskin Adhesive manufactured by Henry or equal, a synthetic rubber based adhesive, quick setting, having the following physical properties: 1. Weight: 6 lbs/gal, 2. Solids by weight: 35%, 3. Drying time (initial set): 30 minutes 2.4 JOINT TREATMENT, PENETRATION AND TERMINATION SEALANT A. Joint Treatment, penetration and termination Sealant shall be HE925 BES Sealant manufactured by Henry or equal; a moisture cure, medium modulus polymer modified sealing compound having the following physical properties: 1. Compatible with sheet air barrier, roofing and waterproofing membranes and substrate, 2. Complies with Fed. Spec. TT-S-00230C, Type II, Class A, 3. Complies with ASTM C 920, Type S, Grade NS, Class 25, 4. Elongation: 450 – 550%, 5. Remains flexible with aging, 6. Seals construction joints up to 1 inch wide DocuSign Envelope ID: 51195338-6F17-4D2B-B990-4A82329E7F4E OC DSS -Hillsborough Commons Skylight Replacement Smith Sinnett / 2020054 Hillsborough, NC Orange County NON PERMEABLE AIR AND VAPOR BARRIERS 07 27 00 - 5 2.5 INSULATION ADHESIVE A. Insulation adhesive shall be Air-Bloc 21 Insulation Adhesive manufactured by Henry or equal; a synthetic, trowel applied, rubber based adhesive, having the following physical properties: 1. Compatibility: With air barrier membrane, substrate and insulation, 2. Air leakage: 0.0026 CFM/ft2 @ 1.6 lbs./ft2 to ASTM E283, 3. Water vapor permeance: 0.03 perms to ASTM E96, PART 3 - EXECUTION 3.1 EXAMINATION A. Examine substrates, areas, and conditions, with Installer present, for compliance with requirements and other conditions affecting performance. 1. Verify that substrates are sound and free of oil, grease, dirt, excess mortar, or other contaminants. 2. Verify that concrete has cured and aged for minimum time period recommended by air barrier manufacturer. 3. Verify that concrete is visibly dry and free of moisture. Test for capillary moisture by plastic sheet method according to ASTM D 4263. 4. Verify that masonry joints are flush and completely filled with mortar. 5. Proceed with installation only after unsatisfactory conditions have been corrected. 3.2 SURFACE PREPARATION A. Clean, prepare, treat, and seal substrate according to manufacturer's written instructions. Provide clean, dust-free, and dry substrate for air barrier application. B. Mask off adjoining surfaces not covered by air barrier to prevent spillage and overspray affecting other construction. C. Remove grease, oil, bitumen, form-release agents, paints, curing compounds, and other penetrating contaminants or film-forming coatings from concrete. D. Remove fins, ridges, mortar, and other projections and fill honeycomb, aggregate pockets, holes, and other voids in concrete with substrate patching membrane. E. Remove excess mortar from masonry ties, shelf angles, and other obstructions. F. Prepare, fill, prime, and treat joints and cracks in substrates. Remove dust and dirt from joints and cracks according to ASTM D 4258. 1. Install modified bituminous strips and center over treated construction and contraction joints and cracks exceeding a width of 1/16 inch. G. Bridge and cover expansion joints and discontinuous deck-to-wall and deck-to-deck joints with overlapping modified bituminous strips. H. At changes in substrate plane, apply sealant or termination mastic beads at sharp corners and edges to form a smooth transition from one plane to another. I. Cover gaps in substrate plane and form a smooth transition from one substrate plane to another with stainless-steel sheet mechanically fastened to structural framing to provide continuous support for air barrier. 3.3 INSTALLTION OF AIR VAPOR BARRIER SYSTEM A. Joint Treatment 1. Seal joints ¼ inch and less between panels of exterior grade gypsum, gypsum sheathing, plywood, OSB or cementitious panels with joint treatment sealant over the face of the panel joint. DocuSign Envelope ID: 51195338-6F17-4D2B-B990-4A82329E7F4E OC DSS -Hillsborough Commons Skylight Replacement Smith Sinnett / 2020054 Hillsborough, NC Orange County NON PERMEABLE AIR AND VAPOR BARRIERS 07 27 00 - 6 a. Apply sealant along the butt joint and trowel smooth to form a continuous layer over the joint extending 1/2 inches on both sides to a uniform thickness of 1/8 inch thick. 2. Seal gaps and voids or irregular joints greater than ¼ inch between panels of exterior grade gypsum, gypsum sheathing, plywood, OSB or cementitious panels with a strip of self-adhered air/vapor barrier transition membrane lapped a minimum of 1-1/2 inches on both sides of the joint. a. Prime surfaces as per manufacturers’ instructions and allow to dry. b. Align and position self-adhering air/vapor barrier transition membrane, remove protective film and press firmly into place. Ensure minimum 2 inches overlap at all end and side laps of membrane. c. Roll all laps and membrane with a counter top roller to ensure seal. 3. Alternately, joints not exceeding 1/8 inch can be sealed with yellow open weave glass fabric. a. Apply yellow open weave glass fabric centered over joint followed by a 1/8 inch (120mils) thick trowel application of air/vapor barrier membrane. b. Allow to dry prior to application of primary air/vapor barrier membrane. B. Inside and Outside Corners 1. Seal inside and outside corners of sheathing boards with a strip of self-adhering air/vapor barrier transition membrane extending a minimum of 3 inches on either side of the corner detail. 2. Prime surfaces as per manufacturers’ instructions and allow to dry. a. Align and position self-adhering transition membrane, remove protective film and press firmly into place. Ensure minimum 2 inches overlap at all end and side laps of membrane. b. Roll all laps and membrane with a counter top roller to ensure seal. C. Crack Treatment – Masonry and Concrete 1. Seal cracks over 1/16 inches in masonry and concrete with a strip of self-adhering air/vapor barrier transition membrane lapped a minimum of 1 1/2 inches on both sides of the crack. a. Prime surfaces as per manufacturers’ instructions and allow to dry. b. Align and position self-adhering air/vapor barrier transition membrane, remove protective film and press firmly into place. Ensure minimum 2 inches overlap at all end and side laps of membrane. c. Roll all laps and membrane with a counter top roller to ensure seal. 2. Alternately, static cracks 1/16 inch to 1/8 inch can be sealed with primary air/vapor barrier membrane. a. Fill crack with primary air barrier membrane. b. Allow to dry prior to application of primary air/vapor barrier membrane. D. Transition Areas 1. Tie-in to structural beams, columns, floor slabs and intermittent floors, parapet curbs, foundation walls, roofing systems and at the interface of dissimilar materials as indicated in drawings with self-adhered air/vapor barrier transition membrane. a. Prime surfaces as per manufacturers’ instructions and allow to dry. b. Align and position self-adhering air/vapor barrier transition membrane, remove protective film and press firmly into place. Provide minimum 3 inch lap to all substrates. c. Ensure minimum 2 inch overlap at all end and side laps of membrane. d. Roll all laps and membrane with a counter top roller to ensure seal. E. Window and Rough Openings 1. Wrap rough openings with self-adhered membrane as detailed. a. Prime surfaces as per manufacturers’ instructions and allow to dry. b. Align and position self-adhering air/vapor barrier transition membrane, remove protective film and press firmly into place. Ensure minimum 2 inch overlap at all end and side laps of membrane. c. Roll all laps and membrane with a counter top roller to ensure seal. F. Through-Wall Flashing Membrane 1. Apply through-wall flashing membrane along the base of masonry veneer walls and over metal shelf angles as detailed. a. Prime surfaces and allow to dry, press membrane firmly into place, over lap minimum 2 inches at all end and side laps. Promptly roll all laps and membrane to ensure the seal. b. Applications shall form a continuous flashing membrane and shall extend up a minimum of 8 inches up the back-up wall. DocuSign Envelope ID: 51195338-6F17-4D2B-B990-4A82329E7F4E OC DSS -Hillsborough Commons Skylight Replacement Smith Sinnett / 2020054 Hillsborough, NC Orange County NON PERMEABLE AIR AND VAPOR BARRIERS 07 27 00 - 7 c. Seal the top edge of the membrane where it meets the substrate using termination sealant. Trowel-apply a feathered edge to seal termination to shed water. d. Install through-wall flashing membrane and extend 1/2 inch from outside edge of veneer. Provide “end dam” flashing as detailed. G. Primary Air/Vapor Barrier – Fluid Applied 1. Apply by spray or flat trowel a complete and continuous unbroken film of liquid air/vapor and rain barrier membrane. a. For temperatures below 40 degrees F apply one component solvent based bitumen air/vapor barrier membrane at a rate of 18.6 sq.ft./gallon to a uniform wet thickness of 90 mils. 2. Spray apply or trowel around all projections and penetrations ensuring a complete and continuous air barrier membrane. 3. Allow air barrier membrane to dry as per manufacturers recommendations prior to placement of insulating materials. H. Primary Air Barrier – Self Adhered 1. Apply self-adhering air/vapor barrier membrane complete and continuous to prepared and primed substrate in an overlapping shingle fashion and in accordance with manufacturer's recommendations and written instructions. Stagger all vertical joints. a. Prime surfaces as per manufacturers’ instructions and allow to dry. b. Align and position self-adhering air/vapor barrier membrane, remove protective film and press firmly into place. Ensure minimum 2 inch overlap at all end and side laps of membrane. c. Roll all laps and membrane with a counter top roller to ensure seal. d. At the end of each days work seal the top edge of the membrane where it meets the substrate with termination sealant. Trowel apply a feathered edge to seal termination and shed water. 3.4 FIELD QUALITY CONTROL A. Testing Agency: Owner will engage a qualified testing agency to perform tests and inspections and prepare test reports. B. Inspections: Air barrier materials and installation are subject to inspection for compliance with requirements. Inspections may include the following: 1. Continuity of air barrier system has been achieved throughout the building envelope with no gaps or holes. 2. Continuous structural support of air barrier system has been provided. 3. Masonry and concrete surfaces are smooth, clean and free of cavities, protrusions, and mortar droppings. 4. Site conditions for application temperature and dryness of substrates have been maintained. 5. Maximum exposure time of materials to UV deterioration has not been exceeded. 6. Surfaces have been primed, if applicable. 7. Laps in strips and transition strips have complied with minimum requirements and have been shingled in the correct direction (or mastic has been applied on exposed edges), with no fishmouths. 8. Termination mastic has been applied on cut edges. 9. Strips and transition strips have been firmly adhered to substrate. 10. Compatible materials have been used. 11. Transitions at changes in direction and structural support at gaps have been provided. 12. Connections between assemblies (membrane and sealants) have complied with requirements for cleanliness, preparation and priming of surfaces, structural support, integrity, and continuity of seal. 13. All penetrations have been sealed. C. Remove and replace deficient air barrier components and retest as specified above. DocuSign Envelope ID: 51195338-6F17-4D2B-B990-4A82329E7F4E OC DSS -Hillsborough Commons Skylight Replacement Smith Sinnett / 2020054 Hillsborough, NC Orange County NON PERMEABLE AIR AND VAPOR BARRIERS 07 27 00 - 8 3.5 CLEANING AND PROTECTION A. Protect air barrier system from damage during application and remainder of construction period, according to manufacturer's written instructions. 1. Protect air barrier from exposure to UV light and harmful weather exposure as required by manufacturer. Remove and replace air barrier exposed for more than 30 days. 2. Protect air barrier from contact with creosote, uncured coal-tar products, TPO, EPDM, flexible PVC membranes, and sealants not approved by air barrier manufacturer. B. Clean spills, stains, and soiling from construction that would be exposed in the completed work using cleaning agents and procedures recommended by manufacturer of affected construction. C. Remove masking materials after installation. END OF SECTION 07 27 00 DocuSign Envelope ID: 51195338-6F17-4D2B-B990-4A82329E7F4E OC DSS -Hillsborough Commons Skylight Replacement Smith Sinnett / 2020054 Hillsborough, NC Orange County SHEET METAL FLASHING AND TRIM 07 62 00 - 1 SECTION 07 62 00 - SHEET METAL FLASHING AND TRIM PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary General Conditions and Division 1 Specification Sections, apply to this Section. 1.2 SUMMARY A. This Section includes sheet metal flashing and trim in the following categories: 1. Exposed trim, roof edges and parapet caps. 2. Metal flashing and counterflashing. 3. Metal Gutter and Downspouts 1.3 RELATED SECTIONS A. The following Sections contain requirements that relate to this Section: 1. Division 04 Section “Unit Masonry” for through-wall flashing and other integral masonry flashings specified as part of masonry work. 2. Division 06 Section "Rough Carpentry" for wood nailers, curbs, and blocking. 3. Coordinate finish and finish colors of work of this section with materials specified in other Division 07 sections. 4. Division 07 Section "Thermoplastic Membrane Roofing" for flashing and roofing accessories installed integral with and part of roofing-system work. 5. Division 07 Section “Metal Roof System” for flashing and roofing accessories associated with the metal roof system. 6. Division 07 Section "Joint Sealants" for elastomeric sealants. 1.4 SUBMITTALS A. Submit each item in this Article according to the Conditions of the Contract and Division 1 Specification Sections. B. Product Data including manufacturer's material and finish data, installation instructions, and general recommendations for each specified flashing material and fabricated product. C. Shop Drawings of each item specified showing layout, profiles, methods of joining, and anchorage details. D. Samples of sheet metal flashing, trim, and accessory items, in the specified finish. Where finish involves normal color and texture variations, include Sample sets composed of 2 or more units showing the full range of variations expected. 1. 8-inch- square Samples of specified sheet materials to be exposed as finished surfaces. DocuSign Envelope ID: 51195338-6F17-4D2B-B990-4A82329E7F4E OC DSS -Hillsborough Commons Skylight Replacement Smith Sinnett / 2020054 Hillsborough, NC Orange County SHEET METAL FLASHING AND TRIM 07 62 00 - 2 E. Qualification data for firms and persons specified in the "Quality Assurance" Article to demonstrate their capabilities and experience. Include lists of completed projects with project names and addresses, names and addresses of architects and owners, and other information specified. 1.5 QUALITY ASSURANCE A. Installer Qualifications: Engage an experience Installer who has completed sheet metal flashing and trim work similar in material, design, and extent to that indicated for this Project and with a record of successful in-service performance. B. Mockups: Prior to installing sheet metal flashing and trim, construct mockups indicated to verify selections made under Sample submittals and to demonstrate aesthetic effects as well as qualities of materials and execution. Build mockups to comply with the following requirements, using materials indicated for final unit of Work. 1. Locate mockups on-site in the location and of the size indicated or, if not indicated, as directed by Architect. 2. Notify Architect one week in advance of the dates and times when mockups will be constructed. 3. Demonstrate the proposed range of aesthetic effects and workmanship. 4. Construct mockups for the following type of sheet metal flashing and trim: a. Parapet Cap Assembly. b. Exposed trim. 5. Obtain Architect's approval of mockups before start of final unit of Work. 6. Retain and maintain mockups during construction in an undisturbed condition as a standard for judging the completed Work. a. Approved mockups in an undisturbed condition at the time of Final Acceptance may become part of the completed Work. 1.6 PROJECT CONDITIONS A. Coordinate Work of this Section with interfacing and adjoining Work for proper sequencing of each installation. Ensure best possible weather resistance, durability of Work, and protection of materials and finishes. B. Interior and exterior corners of all parapet caps and roof edge flashing assemblies shall be mitered, welded and ground smooth. PART 2 - PRODUCTS 2.1 METALS A. Aluminum: Alloy and temper recommended by aluminum producer and finisher for type of use and finish indicated and with not less than the strength and durability of alloy and temper designated below unless otherwise indicated. B. Factory-painted Aluminum Sheet: ASTM B 209, 3003-H14, with a minimum thickness of .040" unless indicated otherwise. C. Metallic-Coated Steel Sheet: (BASE BID) Restricted flatness steel sheet, metallic coated by the hot-dip process and prepainted by the coil-coating process to comply with ASTM A 755/A 755M. DocuSign Envelope ID: 51195338-6F17-4D2B-B990-4A82329E7F4E OC DSS -Hillsborough Commons Skylight Replacement Smith Sinnett / 2020054 Hillsborough, NC Orange County SHEET METAL FLASHING AND TRIM 07 62 00 - 3 1. Aluminum-Zinc Alloy-Coated Steel Sheet: ASTM A 792/A 792M, Class AZ50 coating designation, Grade 40; structural quality. 2. Surface: Smooth, flat. 3. Color: As selected by Architect from manufacturer's full range. 2.2 MISCELLANEOUS MATERIALS AND ACCESSORIES A. Fasteners: Same metal as sheet metal flashing or other noncorrosive metal as recommended by sheet metal manufacturer. Match finish of exposed heads with material being fastened. 1. Fasteners for Stainless-Steel Sheet: Series 316 stainless steel. 2. Fasteners for Aluminum-Zinc Alloy-Coated Steel Sheet: Hot-dip galvanized steel according to ASTM A 153/A 153M or ASTM F 2329 or Series 316 stainless steel. B. Asphalt Mastic: SSPC-Paint 12, solvent-type asphalt mastic, nominally free of sulfur and containing no asbestos fibers, compounded for 15-mil dry film thickness per coat. C. Mastic Sealant: Polyisobutylene; nonhardening, non-skinning, nondrying, nonmigrating sealant. D. Elastomeric Sealant: Generic type recommended by sheet metal manufacturer and fabricator of components being sealed and complying with requirements for joint sealants as specified in Division 7 Section "Joint Sealants." E. Paper Slip Sheet: 5-lb/square red rosin, sized building paper conforming to FS UU-B-790, Type I, Style 1b. F. Metal Accessories: Provide sheet metal clips, straps, anchoring devices, and similar accessory units as required for installation of Work, matching or compatible with material being installed; noncorrosive; size and thickness required for performance. G. Special “End Beam Box Flashing” Fabrications- Provide Box End Flashing Assemblies as detailed on drawings consisting of configurations, shapes and gauges as shown at the end of the “glue-lam” beans. Box end flashing shall be constructed of heavy gauge steel assemblies with all joints mitered, fully welded and ground smooth. After fabrication, the box end flashing units shall be hot dip galvanized with a G-90 minimum coating which will be the final finish. 2.3 FABRICATION, GENERAL A. Sheet Metal Fabrication Standard: Fabricate sheet metal flashing and trim to comply with recommendations of SMACNA's "Architectural Sheet Metal Manual" that apply to the design, dimensions, metal, and other characteristics of the item indicated. B. Comply with details shown to fabricate sheet metal flashing and trim that fit substrates and result in waterproof and weather-resistant performance once installed. Verify shapes and dimensions of surfaces to be covered before fabricating sheet metal. C. Form exposed sheet metal Work that is without excessive oil canning, buckling, and tool marks and that is true to line and levels indicated, with exposed edges folded back to form hems. D. Expansion Provisions: In gutters, space expansion joints as indicated, or if not indicated place as required to provide for one downspouts to be located in any gutter run between expansion joints, with no joints allowed within 24 inches of corners. Fabricate expansion joints in gutters with end caps on both gutter runs, separate gutter runs by 1", cover face of joint with a six-inch exposed joint cover, and cap the joint with an exposed cover plate. DocuSign Envelope ID: 51195338-6F17-4D2B-B990-4A82329E7F4E OC DSS -Hillsborough Commons Skylight Replacement Smith Sinnett / 2020054 Hillsborough, NC Orange County SHEET METAL FLASHING AND TRIM 07 62 00 - 4 E. Lapped or bayonet-type expansion joints are not permitted. F. Sealed Joints: Form non-expansion, but movable, joints in metal to accommodate elastomeric sealant to comply with SMACNA standards and as follows: G. Fabricate sealed joints in prefinished sheet metal with butt joints and concealed splice plates. Install silicone elastomeric sealant between exposed metal work and splice plates, and rivet one side of fabricated unit to splice plate for strength. 1. Do not use lapped or bayonet-type (nested) joints for sheet metal fabrications. 2. Fabricate concealed splice plates of specific size and profile to maintain lines and form of fabricated work. 3. Provide a 1/8" gap between fabricated units at butt joints. H. Separate metal from noncompatible metal or corrosive substrates by coating concealed surfaces at locations of contact with asphalt mastic or other permanent separation as recommended by manufacturer. I. Conceal fasteners and expansion provisions where possible. Exposed fasteners are not allowed on faces of sheet metal exposed to public view. J. Fabricate cleats and attachment devices from same material as sheet metal component being anchored or from compatible, noncorrosive metal recommended by sheet metal manufacturer. K. Size: As recommended by SMACNA manual or sheet metal manufacturer for application but never less than thickness of metal being secured. 2.4 SHEET METAL FABRICATIONS A. General: Fabricate sheet metal items in thickness or weight needed to comply with performance requirements but not less than that listed below for each application and metal. B. Exposed Trim and Parapet Caps: Fabricate from the following material: 1. 22 Ga., 0299 Metallic Coated Steel Sheet C. Base Flashing: Fabricate from the following material: 1. 22 Ga., 0299 Metallic Coated Steel Sheet D. Counterflashing: Fabricate from the following material: 1. 22 Ga., 0299 Metallic Coated Steel Sheet 2.5 ROOF DRAINAGE SHEET METAL FABRICATIONS A. Hanging Gutters: Fabricate to cross section indicated, complete with end pieces, outlet tubes, and other accessories as required. Fabricate in minimum 120-inch- long sections. Furnish flat-stock gutter spacers and gutter brackets fabricated from same metal as gutters, of size recommended by SMACNA but not less than twice the gutter thickness. Fabricate expansion joints, expansion-joint covers, and gutter accessories from same metal as gutters. 1. Expansion Joints: Butt type with cover plate. 2. Accessories: Wire ball downspout strainer, Valley baffles, Continuous removable leaf screen with sheet metal frame and hardware cloth screen. 3. Gutters, Fabricate from the following materials: a. Aluminum-Zinc Alloy-Coated Steel Sheet, 22 gauge b. Exterior Finish: Fluoropolymer two-coat system. c. Color: As selected by Architect from manufacturer's standard colors. DocuSign Envelope ID: 51195338-6F17-4D2B-B990-4A82329E7F4E OC DSS -Hillsborough Commons Skylight Replacement Smith Sinnett / 2020054 Hillsborough, NC Orange County SHEET METAL FLASHING AND TRIM 07 62 00 - 5 d. Size 1: 8” x 6” where indicated in drawings. Slope to downspout. B. Downspouts: Fabricate downspouts complete with mitered elbows. Furnish with metal hangers, from same material as downspouts, and anchors. 1. Fabricated Hanger Style: SMACNA figure designation 1-35C 2. Fabricate from the following materials: a. Aluminum-Zinc Alloy-Coated Steel Sheet, 22 gauge b. Exterior Finish: Fluoropolymer two-coat system. c. Color: As selected by Architect from manufacturer's standard colors. d. Size 1: 4” x 6” where indicated in drawings PART 3 - EXECUTION 3.1 EXAMINATION A. Examine substrates and conditions under which sheet metal flashing and trim are to be installed and verify that Work may properly commence. Do not proceed with installation until unsatisfactory conditions have been corrected. 3.2 INSTALLATION A. General: Unless otherwise indicated, install sheet metal flashing and trim to comply with performance requirements, manufacturer's installation instructions, and SMACNA's "Architectural Sheet Metal Manual." Anchor units of Work securely in place by methods indicated, providing for thermal expansion of metal units; conceal fasteners where possible, and set units true to line and level as indicated. Install Work with laps, joints, and seams that will be permanently watertight and weatherproof. B. Install exposed sheet metal Work that is without excessive oil canning, buckling, and tool marks and that is true to line and levels indicated, with exposed edges folded back to form hems. Install sheet metal flashing and trim to fit substrates and to result in waterproof and weather-resistant performance. Verify shapes and dimensions of surfaces to be covered before fabricating sheet metal. C. Roof Edge and Parapet Cap Flashings: Secure flashing sat roof edges according to meet all wind load conditions. All roof edge and parapet cap flashing corners shall welded, mitered and ground smooth prior to finishing. D. Expansion Provisions: In gutters, space expansion joints as indicated, or if not indicated place as required to provide for two downspouts to be located in any gutter run between expansion joints, with no joints allowed within 24 inches of corners. Fabricate expansion joints in gutters with end caps on both gutter runs, separate gutter runs by 1", cover face of joint with a six-inch exposed joint cover and cap the joint with an exposed cover plate. 1. Lapped or bayonet-type expansion joints are not permitted. E. Sealed Joints: Form non-expansion, but movable, joints in metal to accommodate elastomeric sealant to comply with SMACNA standards and as follows: 1. Fabricate sealed joints in prefinished sheet metal with butt joints and concealed splice plates. Install silicone elastomeric sealant between exposed metal work and splice plates, and rivet one side of fabricated unit to splice plate for strength. a. Do not use lapped or bayonet-type (nested) joints for sheet metal fabrications. 2. Fabricate concealed splice plates of specific size and profile to maintain lines and form of fabricated work. 3. Provide a 1/8" gap between fabricated units at butt joints. F. Separations: Separate metal from non-compatible metal or corrosive substrates by coating concealed surfaces, at locations of contact, with asphalt mastic or other permanent separation as recommended by manufacturer. G. Install reglets to receive counterflashing according to the following requirements: DocuSign Envelope ID: 51195338-6F17-4D2B-B990-4A82329E7F4E OC DSS -Hillsborough Commons Skylight Replacement Smith Sinnett / 2020054 Hillsborough, NC Orange County SHEET METAL FLASHING AND TRIM 07 62 00 - 6 1. Where reglets are shown in masonry, furnish reglets for installation under Division 4 Section "Unit Masonry." H. Counter flashings: Coordinate installation of counter flashings with installation of assemblies to be protected by counterflashing. Install counter flashings in reglets or receivers. Secure in a waterproof manner by means of snap-in installation and sealant, lead wedges and sealant, interlocking folded seam, or blind rivets and sealant. Lap counterflashing joints a minimum of 2 inches and bed with sealant. I. Roof-Drainage System: Install drainage items fabricated from sheet metal, with straps, adhesives, and anchors recommended by SMACNA's Manual or the item manufacturer, to drain roof in the most efficient manner. Coordinate roof-drain flashing installation with roof-drainage system installation. Coordinate flashing and sheet metal items for steep-sloped roofs with roofing installation. J. Roof-Penetration Flashing: Coordinate roof-penetration flashing installation with roofing and installation of items penetrating roof. Install flashing as follows: 1. Turn lead flashing down inside vent piping, being careful not to block vent piping with flashing. 2. Seal and clamp flashing to pipes penetrating roof, other than lead flashing on vent piping. 3.3 ROOF DRAINAGE SYSTEM INSTALLATION A. General: Install sheet metal roof drainage items to produce complete roof drainage system according to SMACNA recommendations and as indicated. Coordinate installation of roof perimeter flashing with installation of roof drainage system. B. Hanging Gutters: Join sections with riveted or with lapped joints sealed with sealant. Provide for thermal expansion. Attach gutters at eave or fascia to firmly anchored straps spaced not more than 36 inches apart. Provide end closures and seal watertight with sealant. Slope to downspouts. 1. Fasten gutter spacers to front and back of gutter. 2. Anchor back of gutter that extends onto roof deck with cleats spaced not more than 24 inches apart. 3. Install gutter with expansion joints at locations indicated, but not exceeding, 50 feet apart. Install expansion-joint caps. C. Downspouts: Join sections with 1-1/2-inch telescoping joints. 1. Provide hangers with fasteners designed to hold downspouts securely to walls. Locate hangers at top and bottom and at approximately 60 inches o.c. in between. 2. Provide elbows at base of downspout to direct water away from building. D. Splash Pans: Concrete splash blocks furnished by the Prime Contractor. E. Expansion-Joint Covers: Install expansion-joint covers at locations and of configuration indicated. Lap joints a minimum of 4 inches in direction of water flow. 3.4 CLEANING AND PROTECTION A. Clean exposed metal surfaces, removing substances that might cause corrosion of metal or deterioration of finishes. 1. Provide final protection and maintain conditions that ensure sheet metal flashing and trim Work during construction is without damage or deterioration other than natural weathering at the time of Final Acceptance. END OF SECTION 07 62 00 DocuSign Envelope ID: 51195338-6F17-4D2B-B990-4A82329E7F4E OC DSS -Hillsborough Commons Skylight Replacement Smith Sinnett / 2020054 Hillsborough, NC Orange County JOINT SEALANTS 07 92 00 - 1 SECTION 07 92 00 - JOINT SEALANTS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary General Conditions and Division 01 Specification sections, apply to work of this section. 1.2 SUMMARY A. This Section includes joint sealants for the following locations: B. Exterior joints in vertical surfaces and non-traffic horizontal surfaces as indicated below. 1. Control and expansion joints in unit masonry. 2. Perimeter of all doors and windows including aluminum window and doors frames. 3. Existing perimeter of all doors and windows including aluminum window and doors frames. 4. Perimeter of all aluminum storefront and curtain wall units. 5. Existing perimeter of all aluminum storefront and curtain wall units. 6. Between all dissimilar materials unless otherwise shown. 7. Control joints and expansion joints in gypsum board ceilings. 8. Other locations as required to keep the building watertight. 9. Other joints as indicated. C. Exterior joints in horizontal traffic surfaces as indicated below: 1. Control, expansion, and isolation joints in cast-in-place concrete slabs for walks and paving. 2. At all locations where concrete walks abut vertical surfaces including building surfaces and back of curb. 3. Between all dissimilar materials unless otherwise shown. D. Interior joints in vertical surfaces and horizontal nontraffic surfaces as indicated below: 1. Control and expansion joints on exposed interior surfaces of exterior walls. 2. Perimeter joints of exterior openings. 3. Vertical control joints on exposed surfaces of interior unit masonry walls and partitions. 4. Perimeter joints between interior wall surfaces and frames of interior doors and windows. 5. Tile control and expansion joints. 6. Perimeter joints of toilet fixtures. 7. Joints between dissimilar materials. 8. Other joints as indicated. E. Interior joints in horizontal traffic surfaces as indicated below: 1. Control and expansion joints in cast-in-place concrete slabs. 2. Control and expansion joints in stone flooring 3. Other joints as indicated. 4. Between all dissimilar materials unless otherwise shown. F. Fire-rated joints in vertical and horizontal non-traffic surfaces. G. Sealants for glazing purposes are specified in Division 08 Section "Framed Entrances and Storefront." 1.3 RELATED SECTIONS A. The following Sections contain requirements that relate to this Section: 1. Division 07 Section "Sheet Metal Flashing and Trim" for sealing joints related to flashing and sheet metal for roofing. 2. Division 08 Section "Glazing" for sealants used in glazing. DocuSign Envelope ID: 51195338-6F17-4D2B-B990-4A82329E7F4E OC DSS -Hillsborough Commons Skylight Replacement Smith Sinnett / 2020054 Hillsborough, NC Orange County JOINT SEALANTS 07 92 00 - 2 1.4 SYSTEM PERFORMANCES A. Provide joint sealants that have been produced and installed to establish and maintain watertight and airtight continuous seals. 1.5 SUBMITTALS A. Product Data: From manufacturers for each joint sealer product required, including instructions for joint preparation and joint sealer application. B. Samples: For verification purposes of each type and color of joint sealer required. Install joint sealer samples in ½ inch wide joints formed between two 6 inch long strips of material matching the appearance of exposed surfaces adjacent to joint sealants. C. Certificates: From manufacturers of joint sealants attesting that their products comply with specification requirements and are suitable for the use indicated. 1.6 QUALITY ASSURANCE A. Installer Qualifications: Engage an Installer who has successfully completed within the last 3 years at least 3 joint sealer applications similar in type and size to that of this Project. B. Single Source Responsibility for Joint Sealer Materials: Obtain joint sealer materials from a single manufacturer for each different product required. C. Product Testing: Provide comprehensive test data for each type of joint sealer based on tests conducted by a qualified independent testing laboratory on current product formulations within a 24-month period preceding date of Contractor's submittal of test results to Architect. 1.7 DELIVERY, STORAGE, AND HANDLING A. Deliver materials to Project site in original unopened containers or bundles with labels informing about manufacturer, product name and designation, color, expiration period for use, pot life, curing time, and mixing instructions for multicomponent materials. B. Store and handle materials in compliance with manufacturers' recommendations to prevent their deterioration or damage due to moisture, high or low temperatures, contaminants, or other causes. 1.8 PROJECT CONDITIONS A. Environmental Conditions: Do not proceed with installation of joint sealants under the following conditions: 1. When ambient and substrate temperature conditions are outside the limits permitted by joint sealer manufacturer or below 40 deg F. 2. When joint substrates are wet due to rain, frost, condensation or other causes. 3. When conditions are such that wind borne dust, dirt and other debris will contaminate the sealants before they are set and capable of resisting such contamination, unless specific and successful measures can be taken to prohibit such contamination. B. Joint Width Conditions: Do not proceed with installation of joint sealants where joint widths are less than allowed by joint sealer manufacturer for application indicated. C. Joint Substrate Conditions: Do not proceed with installation of joint sealants until contaminants capable of interfering with their adhesion are removed from joint substrates. D. General Warranty: The warranties specified in this Article shall not deprive the Owner of other rights the Owner may have under other provisions of the Contract Documents and shall be in addition to, and run concurrent with, other warranties made by the Contractor under requirements of the Contract Documents. DocuSign Envelope ID: 51195338-6F17-4D2B-B990-4A82329E7F4E OC DSS -Hillsborough Commons Skylight Replacement Smith Sinnett / 2020054 Hillsborough, NC Orange County JOINT SEALANTS 07 92 00 - 3 E. Special Installer’s Warranty: Submit a written, non-prorated full warranty, countersigned by the Contractor and the elastomeric sealant Installer agreeing to promptly repair and replace those that leak do not otherwise comply with performance and other requirements specified in this section for the following warranty period: 1. Warranty Period: Two (2) years from date of Final Acceptance. F. Special Manufacturer’s Warranty: Submit a written, non-prorated full warranty, signed by the elastomeric sealant manufacturer agreeing to promptly furnish joint sealants to repair and replace those that leak do not otherwise comply with performance and other requirements specified in this section for the following warranty period: 1. Warranty Period: Ten (10) years from date of Final Acceptance. PART 2 - PRODUCTS 2.1 MATERIALS, GENERAL A. Compatibility: Provide joint sealants, joint fillers and other related materials that are compatible with one another and with joint substrates under conditions of service and application, as demonstrated by sealant manufacturer based on testing and field experience. B. Colors: Provide color of exposed joint sealants as selected by Architect from manufacturer's standard colors. 2.2 ELASTOMERIC JOINT SEALANTS A. Elastomeric Sealant Standard: Provide manufacturer's standard chemically curing, elastomeric sealant of base polymer indicated which complies with ASTM C 920 requirements, including those referenced for Type, Grade, Class, and Uses. B. Multi-Part Nonsag Urethane Sealant for Use NT: Type M, Grade NS, Class 25, and complying with the following requirements for Uses: 1. Uses NT, M, A, and as applicable to joint substrates indicated. a. Provide as the general building sealant for all exterior and interior vertical and non-traffic horizontal joints, unless otherwise indicated. 2. Products: Subject to compliance with requirements, provide one of the following: a. Chem-Calk 500; Bostik Construction Products Div. b. Vulkem 922; Mameco International, Inc. c. Dualthane; W.R. Meadows, Inc. d. Dynatrol II; Pecora Corp. e. Permapol RC-2; Products Research and Chemical Corp. f. Sikaflex-2c NS; Sika Corp. g. Sonolastic NP-2; Sonneborn Building Products Div., Rexnord Chemical Products Inc. h. Dymeric; Tremco Inc. C. One-Part Nonsag Urethane Sealant for Use T: Type S, Grade NS, Class 25, and complying with the following requirements for Uses: 1. Uses T, NT, M, G, A, and, as applicable to joint substrates indicated. a. Provide for exterior concrete paving joints, and for exposed interior concrete slab joints, subject to foot or vehicular traffic; and equipment and isolation joints. 2. Products: Subject to compliance with requirements, provide one of the following: a. Chem-Calk 900; Bostik Construction Products Div. b. Permapal RC-1; Products Research and Chemical Corp. c. Sikaflex-1a; Sika Corp. d. Sikaflex-15LM; Sika Corp. D. One-Part Pourable Urethane Sealant for Use T: Type S, Grade P, Class 25, and complying with the following requirements for Uses: 1. Uses T, M, A, and, as applicable to joint substrates indicated. DocuSign Envelope ID: 51195338-6F17-4D2B-B990-4A82329E7F4E OC DSS -Hillsborough Commons Skylight Replacement Smith Sinnett / 2020054 Hillsborough, NC Orange County JOINT SEALANTS 07 92 00 - 4 a. Provide for interior concrete slab joints to receive floor finishes. 2. Products: Subject to compliance with requirements, provide one of the following: a. Chem-Calk 950; Bostik Construction Products Div. b. Vulkem 45; Mameco International, Inc. c. NR-201 Urexpan; Pecora Corp. d. Sonolastic SL-1; Sonneborn Building Products Div., Rexnord Chemical Products Inc. E. One-Part Nonacid-Curing Silicone Sealant: Type S, Grade NS, Class 25, and complying with the following requirements for Uses and additional joint movement capability: 1. Uses NT, G, A, and, as applicable to joint substrates indicated. a. Additional capability, when tested for adhesion and cohesion under maximum cyclic movement per ASTM C 719, to withstand the following percentage changes in joint width as measured at time of application and remain in compliance with other requirements of ASTM C 920 for Uses indicated: b. 50% movement in both extension and compression for a total of 100% movement. c. Provide for flashing and sheet metal joints as required, and elsewhere as indicated. 2. Products: Subject to compliance with requirements, provide one of the following: a. Chem-Calk N-Cure 2000; Bostik Construction Products Div. b. Dow Corning 790; Dow Corning Corp. c. Siliglaze N SCS 2501; General Electric Co. d. Silipruf SCS 2000; General Electric Co. e. 864; Pecora Corp. f. Rhodorsil 5C; Rhone-Poulenc Inc. g. Spectrum 1; Tremco Inc. h. Spectrum 2; Tremco Inc. 2.3 JOINT SEALANT BACKING A. General: Provide sealant backings of material and type which are nonstaining; are compatible with joint substrates, sealants, primers and other joint fillers; and are approved for applications indicated by sealant manufacturer based on field experience and laboratory testing. B. Sealant Backer Rod: Provide compressible rod stock of polyethylene foam, polyurethane foam, polyethylene jacketed polyurethane foam, butyl rubber C. foam, neoprene foam or other flexible, permanent, durable nonabsorptive material as recommended by sealant manufacturer for back-up of and compatibility with sealant. Where used with hot-applied sealant, provide heat-resistant type which will not be deteriorated by sealant application temperature as indicated. D. Bond Breaker Tape: Provide polyethylene tape or other plastic tape as recommended by sealant manufacturer, to be applied to sealant-contact surfaces where bond to substrate or joint filler must be avoided for proper performance of sealant. Provide self-adhesive tape where applicable. 2.4 MISCELLANEOUS MATERIALS A. Joint Primer/Sealer: Provide type of joint primer/sealer recommended by sealant manufacturer for joint surfaces to be primed or sealed. B. Cleaners for Nonporous Surfaces: Provide nonstaining, chemical cleaners of type which are acceptable to manufacturers of sealants and sealant backing materials, which are not harmful to substrates and adjacent nonporous materials, and which do not leave oily residues or otherwise have a detrimental effect on sealant adhesion or in-service performance. C. Masking Tape: Provide nonstaining, nonabsorbent type compatible with joint sealants and to surfaces adjacent to joints. DocuSign Envelope ID: 51195338-6F17-4D2B-B990-4A82329E7F4E OC DSS -Hillsborough Commons Skylight Replacement Smith Sinnett / 2020054 Hillsborough, NC Orange County JOINT SEALANTS 07 92 00 - 5 2.5 JOINT FILLERS FOR CONCRETE PAVING A. General: Provide joint fillers of thickness and widths indicated. B. Bituminous and Fiber Joint Filler: Provide resilient and non-extruding type premolded bituminous- impregnated fiberboard units complying with ASTM D 1751; FS HH-F-341, Type I; or AASHTO M 213. 1. Where joints are to receive sealant, provide joint fillers with removable plastic top strips. PART 3 - EXECUTION 3.1 EXAMINATION A. Examine joints indicated to receive joint sealants, with Installer present, for compliance with requirements for compliance with requirements for joint configuration, installation tolerances and other conditions affecting joint sealer performance. Do not proceed with installation of joint sealants until unsatisfactory conditions have been corrected. 3.2 PREPARATION A. Surface Cleaning of Joints: Clean out joints immediately before installing joint sealants to comply with recommendations of joint sealer manufacturers and the following requirements: 1. Remove all foreign material from joint substrates which could interfere with adhesion of joint sealer, including dust; paints, except for permanent, protective coatings tested and approved for sealant adhesion and compatibility by sealant manufacturer; old joint sealants; oil; grease; waterproofing; water repellants; water; surface dirt; and frost. 2. Clean concrete, masonry, unglazed surfaces of ceramic tile and similar porous joint substrate surfaces, by brushing, grinding, blast cleaning, mechanical abrading, or a combination of these methods to produce a clean, sound substrate capable of developing optimum bond with joint sealants. Remove loose particles remaining from above cleaning operations by vacuuming or blowing out joints with oil-free compressed air. 3. Remove laitance and form release agents from concrete. 4. Clean metal, glass, porcelain enamel, glazed surfaces of ceramic tile; and other nonporous surfaces by chemical cleaners or other means which are not harmful to substrates or leave residues capable of interfering with adhesion of joint sealants. B. Joint Priming: Prime joint substrates where indicated or where recommended by joint sealer manufacturer based on preconstruction joint sealer-substrate tests or prior experience. Apply primer to comply with joint sealer manufacturer's recommendations. Confine primers to areas of joint sealer bond, do not allow spillage or migration onto adjoining surfaces. C. Masking Tape: Use masking tape where required to prevent contact of sealant with adjoining surfaces which otherwise would be permanently stained or damaged by such contact or by cleaning methods required to remove sealant smears. Remove tape immediately after tooling without disturbing joint seal. 3.3 INSTALLATION OF JOINT SEALANTS A. General: Comply with joint sealant manufacturer's printed installation instructions applicable to products and applications indicated, except where more stringent requirements apply. B. Elastomeric Sealant Installation Standard: Comply with recommendations of ASTM C 962 for use of joint sealants as applicable to materials, applications and conditions indicated. C. Installation of Sealant Backings: Install sealant backings to comply with the following requirements: 1. Install joint fillers of type indicated to provide support of sealants during application and at position required to produce the cross- sectional shapes and depths of installed sealants relative to joint widths which allow optimum sealant movement capability. DocuSign Envelope ID: 51195338-6F17-4D2B-B990-4A82329E7F4E OC DSS -Hillsborough Commons Skylight Replacement Smith Sinnett / 2020054 Hillsborough, NC Orange County JOINT SEALANTS 07 92 00 - 6 a. Do not leave gaps between ends of joint fillers. Bond ends of gaskets together with adhesive of "weld" by other means as recommended by manufacturer to ensure continuous watertight and airtight performance. Miter-cut and bond ends at corners unless molded corner units are provided. b. Do not stretch, twist, puncture, or tear joint fillers. c. Remove absorbent joint fillers which have become wet prior to sealant application and replace with dry material. 2. Install bond breaker tape between sealants and joint fillers, compression seals, or back of joints where adhesion of sealant to surfaces at back of joints would result in sealant failure. 3. Install compressible seals serving as sealant backings to comply with requirements indicated above for joint fillers. D. Installation of Sealants: Install sealants by techniques, that result in sealants directly contacting and fully wetting joint substrates, completely filling recesses provided for each joint configuration, and providing uniform cross-sectional shapes and depths relative to joint widths which allow optimum sealant movement capability. 1. For sidewalks, pavements and similar joints sealed with elastomeric sealants and subject to traffic and other abrasion and indentation exposures, fill joints to a depth equal to 75% of joint width, but neither more than 5/8" deep nor less than 3/8" deep. 2. For normal moving joints sealed with elastomeric sealants but not subject to traffic, fill joints to a depth equal to 50% of joint width, but neither more than ½" deep nor less than 1/4" deep. 3. Install fire-rated sealants or sealants used in fire-rated joints or assemblies in a accordance with manufacturer's recommendations and as acceptable to Code authorities to achieve the required rating. E. Tooling of Non-sag Sealants: Immediately after sealant application and prior to time skinning or curing begins, tool sealants to form smooth, uniform beads of configuration indicated, to eliminate air pockets, and to ensure contact and adhesion of sealant with sides of joint. Remove excess sealants from surfaces adjacent to joint. Do not use tooling agents which discolor sealants or adjacent surfaces or are not approved by sealant manufacturer. 1. Provide concave joint configurations per Figure 6A in ASTM C 962, unless otherwise indicated. 3.4 CLEANING A. Clean off excess sealants or sealant smears adjacent to joints as work progresses by methods and with cleaning materials approved by manufacturers of joint sealants and of products in which joints occur. 3.5 PROTECTION A. Protect joint sealants during and after curing period from contact with contaminating substances or from damage resulting from construction operations or other causes so that they are without deterioration or damage at time of Final Acceptance. If, despite such protection, damage or deterioration occurs, cut out and remove damaged or deteriorated joint sealants immediately and reseal joints with new materials to produce joint sealer installations with repaired areas indistinguishable from original work. END OF SECTION 07 92 00 DocuSign Envelope ID: 51195338-6F17-4D2B-B990-4A82329E7F4E OC DSS -Hillsborough Commons Skylight Replacement Smith Sinnett / 2020054 Hillsborough, NC Orange County PLASTIC GLAZED SKYLIGHTS 03-2020 08620 curb mounted 1 SECTION 08 62 00 PLASTIC GLAZED SKYLIGHTS/THERMALIZED BARREL VAULT / VERTICAL ENDS PART 1-GENERAL 1.1 SUMMARY A. This section includes the following: 1. Curb-mounted plastic glazed barrel vault skylights. a. Double dome, thermalized, barrel vault, with vertical ends. B. Related Sections: The following sections contain requirements that relate to this section: 1. Division 7 Section Sheet Metal Flashing and Trim. 2. Division 7 Joint Sealants. 3. Division 7 Non Permeable Air and Vapor Barrier C. Refer to roofing system sections for roofing accessories to be built into the roofing system to accommodate work of this section. 1.2 PERFORMANCE REQUIREMENTS A. General: Provide unit skylights capable of withstanding loads as defined by the local codes having jurisdiction where units are to be installed without failure. Failure includes the following: 1. Thermal stresses transferred to the building structure. 2. Framing members transferring stresses, including those caused by thermal and structural movement, to glazing. 3. Weakening of fasteners, attachments, and other components. B. Structural Performance: Provide metal-framed skylights, including anchorage, capable of withstanding design pressure indicated without material and deflection failures and permanent deformation of structural members exceeding 0.2 percent of span when tested according to ASTM E 330-97. 1. Design Test Pressure: 40 PSF positive and 40 PSF negative. C. Air Infiltration: Provide metal-framed skylights with maximum air leakage of 0.09 scfm/sq. ft. of surface when tested according to ASTM E 283-91 at a minimum static-air-pressure differential of 6.20psf. D. Water Penetration: Provide metal-framed skylights that do not evidence water penetration when tested according to ASTM E 331-00 and E 547-00 at a minimum differential static pressure of 20 percent of positive design wind load, but not less than 8psf. 1.3 SUBMITTALS A. Product Data Sheet: For each type of skylight specified, include details of construction and installation, relative to applicable curb configuration. B. Samples for Selection: Manufacturer’s color charts showing a full range of colors available for each type of skylight glazing and Aluminum Finish. 1.4 QUALITY ASSURANCE A. Fire-Test-Response Characteristics: Provide glazing fabricated from sheets identical to those tested for the following fire-test-response characteristics, per ASTM test method indicated below, by UL or other testing and inspecting agencies acceptable to authorities having jurisdiction. Identify plastic sheets with appropriate markings of applicable testing and inspecting organization. DocuSign Envelope ID: 51195338-6F17-4D2B-B990-4A82329E7F4E OC DSS -Hillsborough Commons Skylight Replacement Smith Sinnett / 2020054 Hillsborough, NC Orange County PLASTIC GLAZED SKYLIGHTS 03-2020 08620 curb mounted 2 1. Continuous Cast Acrylic: a. Self-Ignition Temperature: 833 deg F when tested per ASTM D 1929 on plastic sheets in the thickness intended for use. b. Smoke density of 3.4% when tested per ASTM D 2843 on plastic sheets in the thickness intended for use. c. Relative- Burning Characteristics: As follows, when tested per ASTM D 635: 1. Burning rate of 1.019 inches (30 mm) per minute or less when tested with a nominal thickness of 0.118 inches (2.3 mm). 2. Impact Modified Resist65 Continuous Cast Acrylic: a. Self-Ignition Temperature: 750 deg F (399 deg C) or greater when tested per ASTM D 1929 on plastic sheets in the thickness intended for use. b. Smoke density of 3.8% or less when tested per ASTM D 2843 on plastic sheets in the thickness intended for use. c. Relative- Burning Characteristics: As follows, when tested per ASTM D 635: 1. Burning rate of 1.4 inches (36 mm) per minute or less when tested with a nominal thickness of 0.060 inches (1.5 mm). 3. Polycarbonate: a. Self-Ignition Temperature: 650 deg F (343 deg C) or greater when tested per ASTM D 1929 on plastic sheets in the thickness intended for use. b. Smoke developed index not greater than 450 where tested in the manner intended for use in accordance with ASTM E 84 or UL 723, or a maximum average smoke density rating not greater than 75 where tested in the thickness intended for use in accordance with ASTM D 2843. 1. Relative- Burning Characteristics: Burning extent of 1 inch (25mm) or less where tested at a nominal thickness of 0.060 inch (1.5mm), or in the thickness intended for use in accordance with ASTM D 635. 1.5 WARRANTY A. General: Warranties specified in this section shall not deprive the Owner of other rights the Owner may have under other provisions of the Contract Documents and shall be in addition to and run concurrent with other warranties made by the Contractor under requirements of the Contract Documents. B. Skylight Warranty: Provide written warranty signed by manufacturer, agreeing to repair or replace work that exhibits defects in materials or workmanship and guaranteeing weather-tight and leak-free performance. “Defects” is defined as uncontrolled leakage of water and abnormal aging or deterioration. 1. Warranty Period: 5 years from date of Substantial Completion. C. Plastic Warranty: Provide written warranty signed by manufacturer agreeing to repair or replace work that has or develops defects in the plastic. “Defects” is defined as abnormal aging or deterioration. 1. Warranty Period for Acrylic/Polycarbonate: 5 years from date of Substantial Completion against yellowing. D. Finish Warranty: Provide written warranty signed by manufacturer agreeing to repair or replace work with finish defects. “Defects” is defined as peeling, chipping, chalking, fading, abnormal aging or deterioration, and failure to perform as required. 1. Warranty Period for Anodized Finish: 1 year from date of Substantial Completion. 2. Warranty Period for Powder Coat Finish: 5 years from date of Substantial Completion. 3. Warranty Period for Kynar 500 Finish: 5 years from date of Substantial Completion. (10 and 20 years available if specified) PART 2- PRODUCTS 2.1 MANUFACTURER A. Manufacturer: Subject to compliance with requirements, provide products by or equal to: 1. Wasco- part of the Velux Group, Wells, ME (800-388-0293). CBSD model, Basis of Design. DocuSign Envelope ID: 51195338-6F17-4D2B-B990-4A82329E7F4E OC DSS -Hillsborough Commons Skylight Replacement Smith Sinnett / 2020054 Hillsborough, NC Orange County PLASTIC GLAZED SKYLIGHTS 03-2020 08620 curb mounted 3 B. Substitutions: Manufactures shall not be considered without prior approval in writing no later than ten (10) calendar days prior to bid. Substitute manufacturers must have been in the custom skylight business for not less than a period of 15 years and must submit to the Architect the following: 1. List of similar projects successfully completed within the last five years. 2. Proof of financial capability. 3. Complete details of proposed skylight. 4. Complete specifications for Architect’s review. 2.2 MATERIALS A. Curb Frame: Extruded aluminum alloy 6063-T5 (min.) ASTM B 221 (ASTM B 221 M) with minimum effective thickness of .090 inches. Provide integral condensation gutter system with corners fully welded for waterproof quality. Curb frame to have glass fiber reinforced polymer thermal break. 1. Poured and de-bridged polyurethane thermal breaks are not acceptable B. Retainer Frame: Extruded aluminum alloy 6063-T5 (min). ASTM B 221 (ASTM B 221 M) with minimum effective thickness of 0.60 inches. C. Pressure Caps: Extruded aluminum alloy 6063-T5 (min). ASTM B 221 (ASTM B 221 M) with minimum effective thickness of 0.100 inches. D. Plastic Sheets: Monolithic, sheets with good weather and impact resistant. 1. Acrylic: (Continuous cast acrylic) or (impact modified continuous cast acrylic) sheet, thermo- formable, and cold formable, Category C-2 or CC-2 Type UVA (formulated with ultraviolet absorber), with Finish 1 (smooth or polished), unless otherwise indicated. a. Extruded acrylic sheet is not acceptable. 2. Polycarbonate: Category C-1 or CC1 weatherable monolithic sheet coated for UV protection. E. Thermal Break: Glass fiber reinforced polymer separating interior metal framing from materials exposed to outside temperature. 1. Poured and de-bridged polyurethane thermal breaks are not acceptable. F. Fasteners: Same metal as metals being fastened, or nonmagnetic stainless steel or other non-corrosive metal as recommended by Wasco Products, Inc. G. Bituminous Coating: SSPC-Paint 12, solvent-type, bituminous mastic, nominally free of sulfur and containing no asbestos fibers, compounded for 15-mil (0.4 mm) dry film thickness per coating. 2.3 PLASTIC BARREL VAULT SKYLIGHT A. General: Factory-assembled or knocked down, curb-mounted unit consisting of cast acrylic glazing, gasketing, inner frame designed to mount on separate curb, and self-contained flashing. 1. Products: Provide model CBSD or equal meeting the requirements of this section. B. Curb: Minimum 3 ½” wide field built (Existing). C. Condensation Control: Fabricate skylight units with integral internal gutters and weeps to collect and dispose of condensation beyond the outside of support curb. D. Shape and Size: As indicated on project drawings. E. Glazing: Outer - impact modified continuous cast acrylic. White. Extruded acrylic not acceptable. F. Glazing: Inner - Continuous cast acrylic. Clear. Extruded acrylic not acceptable. 2.4 FALL PROTECTION SAFETY SCREENS A. Screen: Welded steel wire mesh, 4” x 4” spacing, wire diameter - .188” min. hot dipped galvanized finish on carbon steel or unfinished stainless steel. B. Frame: Extruded aluminum alloy 6063-T5 (min). ASTM B 221 (ASTM B 221 M) with minimum effective thickness of 0.090 inch (2.2 mm). a. Frame includes a pocket for the edges of the screen material, and a downward leg for attachment to any vertical surface of a skylight retainer or frame. DocuSign Envelope ID: 51195338-6F17-4D2B-B990-4A82329E7F4E OC DSS -Hillsborough Commons Skylight Replacement Smith Sinnett / 2020054 Hillsborough, NC Orange County PLASTIC GLAZED SKYLIGHTS 03-2020 08620 curb mounted 4 C. Adjustment Bar: Extruded aluminum bar stock, ¼” x 1”, alloy 6063-T5 (min). ASTM B 221 (ASTM B 221 M). a. Adjustment bar is slotted for width adjustment in the field. D. Fasteners: Nonmagnetic stainless steel or other non-corrosive metal as recommended by manufacturer. 2.5 FABRICATION A. Framing Components: As follows: 1. Factory fit and assemble components. 2. Fabricate components that, when assembled, will have accurately fitted joints with ends coped or mitered to produce hairline joints free of burrs and distortion. 3. Fabricate components to drain water passing joints and to drain condensation and moisture occurring or migrating within skylight system to the exterior. 4. Fabricate components to accommodate expansion, contraction, and field adjustment, and to provide for minimum clearance and shimming at skylight perimeter. 5. Form shapes with sharp profiles, straight and free of defects or deformations, before finishing. 6. Fit and secure joints by heliarc welding. 2.6 ALUMINUM FINISHES A. General: Comply with NAAMM “Metal Finishes Manual” recommendations for application and designations of finishes. B. Finish designations prefixed by AA conform to the system for designations of aluminum finishes established by the Aluminum Association. 1. Mill Finish: Manufacturer’s standard mill finish. PART 3- EXECUTION 3.1 EXAMINATION A. Examine substrates and conditions, with installer present, for compliance with requirements for installation tolerances and other conditions affecting skylight performance. 1. Proceed with installation only after unsatisfactory conditions have been corrected. 3.2 PREPARATION A. Metal Protection: As follows: 1. Where aluminum will contact dissimilar metals, protect against galvanic action by paining contact surfaces with primer or by applying sealant or tape recommended by manufacturer for this purpose. 2. Where aluminum will contact concrete or masonry, protect against corrosion by painting contact surfaces with bituminous paint. 3. Where aluminum will contact pressure-treated wood, separate dissimilar materials by methods recommended by manufacturer. 3.3 INSTALLATION A. General: Comply with manufacturer’s written instructions for protecting, handling, and installing skylight components. B. Following manufacturer’s installations instructions and job specific drawings to ensure proper installation. C. Coordinate with installation of roof deck and other substrates to receive skylight units. DocuSign Envelope ID: 51195338-6F17-4D2B-B990-4A82329E7F4E OC DSS -Hillsborough Commons Skylight Replacement Smith Sinnett / 2020054 Hillsborough, NC Orange County PLASTIC GLAZED SKYLIGHTS 03-2020 08620 curb mounted 5 D. Coordinate with installation of vapor barriers, roof insulation, roofing, and flashing as required to assure that each element of the work performs properly and that combined elements are waterproof and weather tight. Anchor units securely to supporting structural substrates, adequate to withstand lateral and thermal stresses ass well as inward and outward loading pressures. 3.4 CLEANING AND PROTECTION A. Clean exposed metal and plastic surfaces according to manufacturer’s instructions. Touch up damaged metal coatings. B. Final cleaning by others. END OF SECTION DocuSign Envelope ID: 51195338-6F17-4D2B-B990-4A82329E7F4E Hillsborough Commons Skylight Replacement Smith Sinnett 2020054 Hillsborough, North Carolina Orange County Addendum 1 ADD 1-1 ADDENDUM 1 ADDENDUM DATE: August 3rd, 2020 PROJECT: Orange County Hillsborough Commons Skylight Replacement 133 Mayo St., Hillsborough NC, 27278 OWNER: Orange County 131 West Margaret Lane Hillsborough NC, 27278 ARCHITECT: Smith Sinnett Architecture, P.A. 4600 Lake Boone Trail, Suite 205 Raleigh, North Carolina 27607 BIDS DUE: Wednesday, August 13th, 2020 at 5:00 p.m. Orange County Asset Management Submit via email to: jamaro@orangecountync.gov This Addendum shall be included in the contract for the above referenced project. All General, Supplementary and Special Conditions, etc., as originally specified or as modified below shall apply to these items. General 1. A non-mandatory PreBid meeting was held on July 22rd. The bidder list is attached. 2. Note that the bid period has been extended to August 13th. 3. The request for information and product substitution period will end Thursday Wed August 5th. 4. A plan holder list can be obtained from the following location: https://smithsinnett.com/bid/orange-county-skylight-replacement/ 5. This is a single prime contract. Proposals are be being accepted from insured/bonded GC’s or roofers capable of completing all work involved. Specifications 1. Revision: 086200 Plastic Glazed Skylights, 2.4: Fall protection screens will not be required for systems which are OSHA Life Safety Certified. 2. Clarification: 072700 Nonpermeable Air and Vapor Barrier – Garland Co. is to be considered a basis of design for adhered flashings. DocuSign Envelope ID: 51195338-6F17-4D2B-B990-4A82329E7F4E Hillsborough Commons Skylight Replacement Smith Sinnett 2020054 Hillsborough, North Carolina Orange County Addendum 1 ADD 1-2 Substitution Requests 3. 086200 Plastic Glazed Skylights: Kingspan(CPI) is to be added to the list of approved manufacturers 4. 086200 Plastic Glazed Skylights: Kalwall is to be added to the list of approved manufacturers 5. 086200 Plastic Glazed Skylights: Sunoptics is to be added to the list of approved manufacturers End of Addendum 1 DocuSign Envelope ID: 51195338-6F17-4D2B-B990-4A82329E7F4E Hillsborough Commons Skylight Replacement Smith Sinnett 2020054 Hillsborough, North Carolina Orange County Addendum 2 ADD 2-1 ADDENDUM 2 ADDENDUM DATE: August 3rd, 2020 PROJECT: Orange County Hillsborough Commons Skylight Replacement 133 Mayo St., Hillsborough NC, 27278 OWNER: Orange County 131 West Margaret Lane Hillsborough NC, 27278 ARCHITECT: Smith Sinnett Architecture, P.A. 4600 Lake Boone Trail, Suite 205 Raleigh, North Carolina 27607 BIDS DUE: Wednesday, August 13th, 2020 at 5:00 p.m. Orange County Asset Management Submit via email to: jamaro@orangecountync.gov This Addendum shall be included in the contract for the above referenced project. All General, Supplementary and Special Conditions, etc., as originally specified or as modified below shall apply to these items. General 1. A non-mandatory PreBid meeting was held on July 22rd. The bidder list is attached. 2. Note that the bid period has been extended to August 13th. 3. The request for information and product substitution period will end Thursday Wed August 5th. 4. A plan holder list can be obtained from the following location: https://smithsinnett.com/bid/orange-county-skylight-replacement/ 5. This is a single prime contract. Proposals are be being accepted from insured/bonded GC’s or roofers capable of completing all work involved. Specifications 1. Revision: 086200 Plastic Glazed Skylights, 2.4: Fall protection screens will not be required for systems which are OSHA Life Safety Certified. 2. Clarification: 072700 Nonpermeable Air and Vapor Barrier – Garland Co. is to be considered a basis of design for adhered flashings. DocuSign Envelope ID: 51195338-6F17-4D2B-B990-4A82329E7F4E Hillsborough Commons Skylight Replacement Smith Sinnett 2020054 Hillsborough, North Carolina Orange County Addendum 2 ADD 2-2 Substitution Requests 3. 086200 Plastic Glazed Skylights: Kingspan(CPI) is to be added to the list of approved manufacturers 4. 086200 Plastic Glazed Skylights: Kalwall is to be added to the list of approved manufacturers 5. 086200 Plastic Glazed Skylights: Sunoptics is to be added to the list of approved manufacturers End of Addendum 2 DocuSign Envelope ID: 51195338-6F17-4D2B-B990-4A82329E7F4E Hillsborough Commons Skylight Replacement Smith Sinnett 2020054 Hillsborough, North Carolina Orange County Addendum 3 ADD 3-1 ADDENDUM 3 ADDENDUM DATE: August 10th, 2020 PROJECT: Orange County Hillsborough Commons Skylight Replacement 133 Mayo St., Hillsborough NC, 27278 OWNER: Orange County 131 West Margaret Lane Hillsborough NC, 27278 ARCHITECT: Smith Sinnett Architecture, P.A. 4600 Lake Boone Trail, Suite 205 Raleigh, North Carolina 27607 BIDS DUE: Wednesday, August 13th, 2020 at 5:00 p.m. Orange County Asset Management Submit via email to: jamaro@orangecountync.gov This Addendum shall be included in the contract for the above referenced project. All General, Supplementary and Special Conditions, etc., as originally specified or as modified below shall apply to these items. Substitution Requests 1. To be revised from Addendum 2: Sunoptics is to be removed from the previously accepted list of substitutions as the proposed system will not meet the design intent established in the bid documents. Vaulted skylights are to be of one continuous assembly from end to end. End of Addendum 3 DocuSign Envelope ID: 51195338-6F17-4D2B-B990-4A82329E7F4E