Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2019-136-E AMS - Warren Hay for Link IT closet duct rework
DocuSign Envelope ID:4659CD86-5C5C-4726-9F10-AA69EA5C98C1 NORTH CAROLINA CONSTRUCTION SERVICES AGREEMENT UNDER$50,000 ORANGE COUNTY THIS CONSTRUCTION AGREEMENT (hereinafter"Agreement"), is made and entered into this 5th day of December, 2018 by and between Orange County, North Carolina(hereinafter the "County" and/or "Owner") party of the first part; and Warren Hay Mechanical Contractors, Inc (hereinafter the "Contractor"), party of the second part; WITNESSETH: For the purpose and subject to the terms and conditions hereinafter set forth, the Owner hereby contracts for the construction services of the Contractor, and the Contractor agrees to provide the construction services to the Owner in accordance with the terms of this Agreement. 1. TERM AND MAXIMUM AMOUNT PAYABLE Beginning and ending dates of contract: December 5, 2018 through December 5, 2019. The Project Commencement Date shall be December 5, 2019. Dollar Amount Not to Exceed: Eleven Thousand Four Hundred Dollars ($11,400.00) 2. SERVICES Contractor agrees to provide the following construction services (the "Work"): Provide all labor and materials to complete the mechanical scope of work as outlined in drawings M 1.0, M0.2, M1.1 all dated 5/25/18, per Warren Hay Mechanical Contractors, Inc rate sheet dated July 1, 2018. Contractor shall not sub-contract all or any part of the construction services provided for in this Agreement without prior written approval of the Owner. Contractor shall be responsible for all errors or omissions, in the performance of the Agreement. Contractor shall correct any and all errors, omissions, discrepancies, ambiguities, mistakes or conflicts at no additional cost to Owner. Contractor is solely responsible for obtaining all permits necessary to complete the Work in compliance with local, state, and/or federal law. The Contractor is responsible for all physical damage to owned or rented machinery, tools, equipment, forms, and other items owned, rented or used by the Contractor and/or Subcontractor(s) in the performance of the Work including all of Owner's property in Contractor's care, custody, or control, and all such property while it is in transit. 3. PAYMENT Contractor shall submit an invoice for construction services provided. The invoice shall contain Contractor's name and federal tax identification number and shall be signed and dated by an officer of Contractor. It shall detail all construction services provided in payment requests. The Owner will make payments to Contractor within thirty (30) days after receipt of and approval of the invoice by the contracting department. In the event the amount stated on an invoice is disputed by Owner, then Owner may withhold payment of all or a portion of the amount stated on an invoice until the parties resolve the dispute. In addition, should Contractor fail to perform its duties under the terms of this Revised 12/18 1 DocuSign Envelope ID:4659CD86-5C5C-4726-9F10-AA69EA5C98C1 Agreement, Owner may, without fault or penalty, withhold any payment associated with the Work to be performed until such time as said work is completed. 4. RELATIONSHIP OF PARTIES Contractor is an independent contractor of the Owner. Contractor represents that it has or will secure, at its own expense, all personnel required in performing the construction services under this Agreement. Such personnel shall not be employees of or have any contractual relationship with the Owner. All personnel engaged in work under this Agreement shall be fully qualified and shall be authorized or permitted under state and local law to perform such construction services. It is further agreed that Contractor will obey all State and Federal statutes, rules and regulations which are applicable to provisions of the construction services called for herein. Neither Contractor nor any employee of the Contractor shall be deemed an officer, employee or agent of the Owner. 5. SUSPENSION AND TERMINATION This Agreement may be terminated by Contractor upon thirty (30) days' written notice to the Owner, and the Owner may terminate this Agreement upon thirty (30) days' written notice to Contractor. Owner may suspend the Work at any time for Owner's convenience and without penalty to Owner upon three (3) days' notice to Contractor. Upon any suspension by Owner Contractor shall discontinue the Work and shall not resume the Work until notified to proceed by Owner. The notice required by this section or any other notice shall be delivered via certified mail, return receipt requested to the parties at the addresses as shown on the signature page to this Agreement. Such notice is deemed given upon its delivery to, or deposit in a receptacle of, the United States Post Office. 6. INSURANCE REQUIREMENTS Contractor shall obtain, at its sole expense, Commercial General Liability Insurance, Automobile Insurance, Workers' Compensation Insurance, and any additional insurance as may be required by Owner's Risk Manager as such insurance requirements are described in the Orange County Risk Transfer Policy and Orange County Minimum Insurance Coverage Requirements (each document is incorporated herein by reference and may be viewed at http://www.oran eg countync. og v/departments/purchasing_division/contracts.phn). If Owner's Risk Manager determines additional insurance coverage is required such additional insurance shall be designated here N/A (if no additional insurance required mark N/A as being not applicable). Contractor shall not commence construction work until such insurance is in effect and certification thereof has been received by the Owner's Risk Manager. 7. INDEMNIFICATION Contractor agrees, without limitation, to defend, indemnify, save, and protect Owner and Owner's lender, if any, harmless from and against any and all claims, liens, liabilities, losses, damages, causes of action, and expenses (including court costs and reasonable attorney's fees related thereto) arising out of, in connection with, or resulting from any negligence, act or failure to act by the Contractor, the Contractor's agents, assigns or employees resulting in property damage or personal injury, including death, or other loss related to the Work. Contractor is responsible for all errors or omissions caused by its agents, contractors, employees, or assigns in the performance of this Agreement. It is the intent of this section to require Contractor to indemnify the Owner to the full extent permitted under North Carolina law. Revised 12/18 2 DocuSign Envelope ID:4659CD86-5C5C-4726-9F10-AA69EA5C98C1 8. NON-ASSIGNMENT AND OWNER'S REPRESENTATIVE Contractor shall not assign all or any part of this Agreement, including rights to payments, to any other parry without the prior written consent of the Owner. The County has designated(Angel Barnes)to act as the County's representative with respect to the Work and shall have the authority to render decisions within guidelines established by the County Manager and/or the County Board of Commissioners and shall be available during working hours as often as may be reasonably required to render decisions and to furnish information. 9. NON—APPROPRIATION Contractor acknowledges that Owner is a governmental entity, and the validity of this Agreement is based upon the availability of public funding under the authority of its statutory mandate. In the event that public funds are unavailable and not appropriated for the performance of Owner's obligations under this Agreement, then this Agreement shall automatically expire without penalty to Owner immediately upon written notice to Contractor of the unavailability and non-appropriation of public funds. It is expressly agreed that Owner shall not activate this non- appropriation provision for its convenience or to circumvent the requirements of this Agreement, but only as an emergency fiscal measure during a substantial fiscal crisis. In the event of a change in the Owner's statutory authority, mandate and/or mandated functions, by state and/or federal legislative or regulatory action, which adversely affects Owner's authority to continue its obligations under this Agreement, then this Agreement shall automatically terminate without penalty to Owner upon written notice to Contractor of such limitation or change in Owner's legal authority. 10. DISPUTE RESOLUTION Any dispute with respect to any provision of, or the performance or non-performance of, this Agreement shall be subject to the Dispute Resolution Rules and Procedures for Orange County Design, Building Construction, Renovation, and Repair Projects. The policy is incorporated herein by reference and may be viewed at http://www.oran eg cogptygc._ov�/departments/purchasing division/contracts.php). 11. ENTIRE AGREEMENT The parties have read this Agreement and agree to be bound by all of its terms, and further agree that it, together with specifically referenced documents, constitutes the complete and exclusive statement of the Agreement between the parties unless and until modified by a written amendment to this Agreement signed by the parties. Modifications may be evidenced by telefacsimile signatures. Should any conflict arise in the terms of any documents referenced herein and this Agreement the terms of this Agreement shall be given priority and shall control over all other such documents. Should a request for proposals and a proposal be referenced the terms of the request for proposals shall have priority over the terms of the proposal. 12. COMPLIANCE WITH LAW/GOVERNING LAW Both parties agree that this Agreement shall be governed by the laws of the State of North Carolina and any action brought under this Agreement shall be brought in the General Court of Justice of the State of North Carolina in Orange County. Contractor shall at all times remain in Revised 12/18 3 DocuSign Envelope ID:4659CD86-5C5C-4726-9F10-AA69EA5C98C1 compliance with all applicable local, state, and federal laws, rules, and regulations including but not limited to all state and federal non-discrimination laws, policies, rules, and regulations and the Orange County Non-Discrimination Policy and Orange County Living Wage Policy(each policy is incorporated herein by reference and may be viewed at http://www.oran eg copnMc.gov/departments/purchasing division/contracts.php). Any violation of the Orange County Non-Discrimination Policy is a breach of this Agreement and County may immediately terminate this Agreement without further obligation on the part of the County. This paragraph is not intended to limit and does not limit the definition of breach to discrimination. By executing this Agreement Contractor affirms that Contractor and any subcontractors of Contractor are and shall remain in compliance with Article 2 of Chapter 64 of the North Carolina General Statutes. By executing this Agreement Contractor certifies that Contractor has not been identified, and has not utilized the services of any agent or subcontractor identified, on the lists created by the State Treasurer pursuant to G.S. 147-86.58 and G.S. 147-86.81. This Agreement together with any amendments or modifications may be executed electronically. All electronic signatures affixed hereto evidence the consent of the Parties to utilize electronic signatures and intent of the Parties to comply with Article I IA and Article 40 of North Carolina General Statute Chapter 66. IN WITNESS WHEREOF Orange County and the Contractor have signed this agreement, effective as of the day and date first above written. ORANGE COUNTY CONTRACTOR 0 Sig tl by: D 5 9 d by: 3/4/2019 B �v,�� 2/27/2019 C063]9949]35E4]].. � CF County Manager WarrenCE630030G lay Mechanical Contractors Inc 200 S. Cameron St. PO Box 818 P.O. Box 8181 Hillsborough Hillsborough,NC 27278 NC, 27278 Revised 12/18 4 Orange Coonty Contractor Time Material Rate Schedule 1 Asset Management Services Company: Dates Applicable Warren Hay Mechanical Contractors,Inc From: to Address: 7/1/2018 12/31/2018 PO Box 818 Hillsborough,NC 27278 1.Labor Rates Rate Level Description Apprentice Journeyman 2 Man(Crew)Install Service Tech Straight Time $150.00 $0.00 $120 Overtime(Time and 1/2) $225.00 $0.00 $180.00 Overtime(Double) $300.00 $0.00 $240.00 2.Overtime Check Appropriate Rate Overtime is defined as: Time and 1/2 Double Over_8_Hours per day o El Over_40_Hours per week 1 o 11 Before am and after pm 0 Saturdays(eight hours or less) Sundays 0 U rn LU Holidays(list dates below) w Same as County Schedule rn a a 0 N U to co co 0 U rn co co v 0 Q 0 c w c U) U O Orange County Contractor Time Material Rate Schedule 2 Asset Management Services 3.Material Charge: Mark-Up on materials(if any) 45% Handling charge materials(if any) % Mark-Up on subcontracted work(if i 20% Mark-Up on rental equipment(if an) 25% 4.Special Equipment Billing Rates Description of Contractor Owned Equipment Hourly Daily Weekly S.Emergency Off-Hours Coverage:(Check One) We do we do not Provide emergency off-hours coverage for our customers Type of off-hours coverages: 24/7 365 U rn U 6.Response Time: Regular Hours As quickly as possible Emergency Off Hours As quickly as possible LO Q w rn Q Personnel Name Position Phone No. Cell No. Q o Larry Warren Owner 919-732-4362 919-971-7190 rn Bryan Warren Service Mgr 919-732-4362 919-215-3219 CN r, Ron LaPann Commercial Div 919-732-4362 919-612-6850 C� Brian Logan Field Supervisor(Intallation) 919-215-0525 gO Darius La Point Field Supervisor(Service) 919-612-4474 CID 00 LID U rn co v 0 Q 0 c w c in U O Orange County Contractor Time Material Rate Schedule 3 Asset Management Services 7.Miscellaneous:Please specify any additional charges that may be applicable. Submitted for Contractor Accepted by: Marren Ray Mechan(cal_Contractors Inc. (Contractor Name) �� (Signature) (Date) (Signaturej (Date) (Printed Name) Ron LaPann (Printed Name) (Title) U rn UO (Title) (Department) w Commercial Division rn a a 0 N N U Ln 00 LO 00 0 U rn co v 0 Q 0 0 c w c s� U) U O 0 n 00 MECHANICAL SPECIFICATIONS ,n IT IS THE INTENT OF THESE SPECIFICATIONS TO FURNISH A COMPLETE HEATING, VENTILATING, AND AIR T • Ip z CONDITIONING SYSTEM, FULLY ADJUSTED, AND READY FOR USE. SEE NOTE ALL MECHANICAL WORK TO BE DONE IN COMPLIANCE WITH NORTH CAROLINA BUILDING CODE AND ALL LOCAL v�i Im CODES. AIR FLOW SUPPLY/RETURN DUCT g_ THIS CONTRACTOR SHALL GIVE ALL NECESSARY NOTICES, OBTAIN ALL PERMITS AND PAY ALL SALES TAXES, ° SS-1A cam, I� Q AND OTHER COSTS, IN CONNECTION WITH HIS WORK. ROUND RUNOUT FLEXIBLE DUCT, 222 cloister court Iz - FLEXIBLE DUCT CONNECTION TO METAL DUCT 5' MAX. LENGTH SUSPEND WITH (4)STRAP LLJ ALL MATERIAL AND EQUIPMENT THAT CAN BE U.L. LISTED SHALL BE FURNISHED FOR THIS PROJECT. TOP OF DUCT RIGID SHEET HANGERS chapel hill, nc 27514 METAL BOX. 919.401 .8586 a FROM STRUCTURE ABOVE MATERIAL AND EQUIPMENT HAS BEEN CAREFULLY SELECTED FOR THIS PROJECT AND THE CONTRACTOR IS MANUAL www.cra-ae.com I EXPECTED TO PROVIDE ALL ITEMS AS CLOSELY AS POSSIBLE TO THE SPECIFICATIONS AND AS CALLED FOR ON VOLUME TRANSITION � o DAMPER LINED WITH THE DRAWINGS. ROUND DUCT DUCT LINER. 1O BRANCH TAKE-OFF NECK (IF REQUIRED) SUBMIT THREE (3) SETS OF EQUIPMENT DATA SHOP DRAWINGS TO ENGINEER FOR ALL ITEMS TO BE TURNING VANE OPEN TO ATTIC z FURNISHED AND INSTALLED FOR APPROVAL. COMPLETELY SEE NOTE DAMPER TAG INSULATE OR RIBBON 1 1 rg THIS CONTRACTOR SHALL INCLUDE IN THE WORK, WITHOUT EXTRA COST TO THE OWNER, ANY LABOR, SIDE OF DUCT BACK OF �1 1� SS-1 B Q MATERIALS, SERVICES, APPARATUS, DRAWINGS, IN ORDER TO COMPLY WITH ALL APPLICABLE LAWS, DIFFUSER — BALANCE DAMPER C SPIN TAP WITH MAN_�A= \ UAL 1 _ WHERE SPECIFIED. ORDINANCES, RULES AND REGULATIONS, WHETHER OR NOT SHOWN ON DRAWINGS AND/OR SPECIFIED. NO AIR FLOW VOLUME DAMPER CEILING//T 0 CLAIM FOR EXTRAS WILL BE APPROVED WITHOUT PRIOR COORDINATION FOR CONFLICTS BY CONTRACTOR, AND (MECHANICAL CONTRACTOR SHALL RKa XDE' w WRITTEN REQUEST AND WRITTEN APPROVAL PRIOR TO PERFORMING WORK. c o PERFORATWA ED PROVIDE ACCESS DOOR FOR ANY ALL WORK AND EQUIPMENT TO BE GUARANTEED BY CONTRACTOR FOR ONE 1 YEAR. AN ADDITIONAL FOUR DOWN TO DIFFUSER VOLUME DAMPER LOCATED ABOVE SUPPLY ( ) CEILING. RETURN DIFFUSER. (4) YEAR WARRANTY SHALL BE PROVIDED ON ALL COMPRESSORS. _ DIFFUSER HARD CEILING) DIFFUSER MECHANICAL CONTRACTOR REFER TO GRILLE = ENGINEERS o MANUAL FLEXIBLE CONNECTION TO SUPPLY DIFFUSER SCHEDULE FOR TYPE AND Reece, Noland & McElrath, Inc. ALL MATERIALS AND EQUIPMENT TO BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS AND GOOD VOLUME ELECTRICAL CONTRACTOR I NECK SIZE 94 Main Street DAMPER N o RECOMMENDED PRACTICES. NOTE: I Canton, North Carolina 28716 c� z PHONE:828-492-0677 NC CERT.N0.C-0149 FAX:828492-1054 = 10 00 1. ALL MANUAL VOLUME DAMPERS (FOR INSULATED DUCTWORK)SHALL I MAIL@RNM-ENGENEERS.COM p2018 WWW.RNM-ENGINEERS.COM ALL WORK AND MATERIALS SHALL MEET APPROVAL OF ARCHITECT/ENGINEER. SINGLE DROP 1,� o BE PROVIDED WITH AN ELEVATED REGULATOR(STAND-OFF) EQUAL TO THIS CONTRACTOR SHALL GIVE FULL COOPERATION TO OTHER TRADES. WHERE THE WORK OF THIS NOTE: NOTE : DURO DYNE SRST SERIES. STAND SHALL EXTEND A MINIMUM OF 2 1� o CONTRACTOR WILL BE INSTALLED IN CLOSE PROXIMITY TO, OR WILL INTERFERE WITH WORK OF OTHER TRADES, 1. MANUAL VOLUME DAMPERS SHALL BE PROVIDED FOR ALL FLEXIBLE DUCT CONNECTIONS TO SHEET METAL SHALL BE BEYOND DUCTWORK WITH EXTENDED TAB/SHAFT. NOTE: 1� U HE SHALL ASSIST IN WORKING OUT SPACE CONDITIONS TO MAKE SATISFACTORY ADJUSTMENTS. IF THIS ALL SUPPLY AND RETURN SINGLE DROP DUCT RUNS. SECURED WITH NYLON STRAP AND 2 SHEET METAL SCREWS (MIN.). 2. MANUAL VOLUME DAMPERS SHALL BE PROVIDED FOR ALL SUPPLY THE SPIT SYSTEM A/C UNIT SPECIFIED ONLY REQUIRES A SINGLE BREAKER SPACE. No m CONTRACTOR INSTALLS HIS WORK BEFORE COORDINATING WITH OTHER TRADES, HE SHALL MAKE THE AND RETURN RUNOUTS. THE INSIDE UNIT IS SUB FED FROM THE OUTSIDE UNIT. ELECTRICAL CONTRACTOR IS o NECESSARY CHANGES IN HIS WORK TO CORRECT THE CONDITION WITHOUT EXTRA CHARGE. RESPONSIBLE FOR WIRING TO OUTSIDE UNIT. MECHANICAL CONTRACTOR IS RESPONSIBLE FOR WIRING FROM OUTSIDE UNIT TO INDOOR UNIT. M.C.TO FURNISH o DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL ARRANGEMENTS OF SYSTEMS AND WORK INCLUDED BOTH DISCONNECTS. IN THE CONTRACT. DRAWINGS ARE NOT TO BE SCALED. DUCTWORK DETAILS FLEX. CONNECTION DETAIL ROUND NECK DIFFUSER SPLIT SYSTEM WIRING DETAIL PLENUM CEILING RETURN GRILL z NO SCALE Cot = ALL DUCTWORK TO BE FABRICATED FROM GALVANIZED SHEET METAL AND INSTALLED ACCORDING TO NO SCALE NO SCALE NO SCALE NO SCALE o REQUIREMENTS OF NFPA 90A, SMACNA, AND ASHRAE GUIDE AND DATA BOOKS. =II V) 1`X111111itfill/, t° ALL FLEXIBLE DUCTWORK, FOR CONNECTIONS BETWEEN DIFFUSERS AND BRANCH DUCTS WHERE INDICATED, TO GALV. ALL-THREADED "All BE THERMAFLEX TYPE MKE . TO ANGLES ROD (TYP) „ CONTINUE UP TO 1/2 0 THREADED � om e v, 10 ALL DUCT SEAMS TO BE TAPED WITH FASSON �AFTS-100/3 SMACNA TAPE, OR EQUAL. 7' 1 STRAP STRUCTURAL ROOF SUPPORT. ROD. (TYP) P a� o `—' � SEE DETAIL " " SHEET �$e,� VOLUME CONTROL DAMPERS (BALANCING) SHALL BE INSTALLED IN EACH BRANCH OR ZONE DUCT. 1"STRAP fy,��a �aj•� r vgvvvpg4q .o BAND A INSULATION 1/0)y M0��`�`ti, DAMPERS WHICH ARE PART OF A MANUFACTURED AIR GRILL DO NOT MEET THIS REQUIREMENT. W17ititillo ALL SQUARE ELBOWS SHALL HAVE TURNING VANES INSTALLED. TURNING VANES SHALL BE APPLIED EQUALLY DUCT DUCT SPRING VIBRATION ISOLATORS. _ _ DUCT TO THE RETURN AIR SIDE. DUCTWORK SIZES INDICATED ON DRAWINGS ARE AS REQUIRED FOR FREE INSIDE AREAS. P W _� GALV.ANGLE NUT & LOCK WASHER. SCREW(TYP) TOP AND BOTTOM ALL DUCTWORK TO BE INSULATED WITH 2" BLANKET TYPE INSULATION 1 LB. DENSITY (MIN. R=6.5) WITH DUCTS UP TO DUCTS ABOVE ROUND lo VAPOR BARRIER JACKET OF .002 INCH THICK ALUMINUM FOIL LAMINATED. 48"WIDTH 48"WIDTH o GASKET ALL PIPING AND DUCTWORK TO BE SUSPENDED WITH APPROPRIATE HANGERS, INSTALLED AND SPACED PER NC LOW PRESSURE DUCTWORK SUPPORT LUGS. lo MECHANICAL CODE. 1"STRAP (IF PROVIDED) NUT & LOCK ALL SUPPLY GRILLES AND DIFFUSERS TO BE EQUIPPED WITH VOLUME CONTROLS. TO ANGLES WASHER. TOP <>- <? 1" HANGER AND BOTTOM. AIR HANDLING EQUIPMENT SHALL BE ISOLATED FROM DIRECT CONTACT WITH SUPPLY OR RETURN AIR RECTANGULAR OR STRAP DUCTWORK. FLEXIBLE CONNECTIONS SHALL BE INSTALLED BETWEEN THE EQUIPMENT AND DUCT. FLEXIBLE FLAT-OVAL DUCT CONNECTIONS SHALL BE MADE OF APPROVED FLAMEPROOFED FABRIC OR OTHER APPROVED NON—COMBUSTIBLE DUCT ll MATERIAL. � \ EQUIPMENT SECTION "A-A" X v, INDEPENDENT T&B AGENCY (AABC OR NEBB CERTIFIED) TO PERFORM ALL ADJUSTMENTS AND BALANCING OF o � 0) C SYSTEMS, EQUIPMENT, CONTROLS, ETC., NECESSARY FOR THE SYSTEM TO PROVIDE THE REQUIRED BAND if _ PERFORMANCE AND TO OPERATE SAFELY. SUBMIT CERTIFIED T&B REPORT, AND "AS—BUILT" DRAWINGS TO O ENGINEER SHOWING ACTUAL AIR FLOWS AT EACH GRILL INSTALLED UNDER THIS CONTRACT. REPORT GALV.ANGLE E CHANNEL • GALV.ALL-THREADED -_ ACCESS PANEL PROCEDURES TO BE PER AABC/NEBB GOOD PRACTICES AND RECOMENDATIONS. T&B TO BE PALMETTO OR ROD (TYP) ROUND C3X6 APPROVED EQUAL. T&B TO BE UNDER MECHANICAL CONTRACT. UPON COMPLETION OF ALL WORK AND ALL TESTS, INSTRUCT THE OWNER OR HIS REPRESENTATIVE FULLY IN CASING • W 1— THE OPERATIONS, ADJUSTMENTS, AND MAINTENANCE OF ALL EQUIPMENT FURNISHED. MED. AND HIGH PRESSURE DUCTWORK ' 4 GASKET Ca < E PROVIDE OWNER MAINTENANCE INSTRUCTIONS AND SCHEDULE FOR THE PRINCIPAL ITEMS OF EQUIPMENT EQUIPMENT SUPPORT DETAIL FURNISHED. MANUFACTURE DUCTWORK HANGER DETAILS MANUFACTURER'S ADVERTISING LITERATURE OR CATALOGS WILL NOT BE ACCEPTABLE. HANDLE INSIDE N � � � o NO SCALE NO SCALE > 0C=:= 0 V F_ 0 s 0 O o � = o = INSULATION FLEXIBLE R R R 1/2" [15mm] FACTORY FABRICATED LATCH WASHER SHALL SHALL co SHALL ROUND ROD PIN STIFFEN INSULATION no. revisions EQUAL �i�� EQUAL J��GI� EQUAL BLADE AS DUCT OUTSIDE END BEARING SECTION "B-B" RFQ1 IIRFn 7 OR BE OR BE TOR BE Tuuumf \-- GREATER GREATER VANE GREATER INSULATION STAND-OFF ACCESS DOOR + THAN W. VANE THAN THAN 1/3W. 1/6W. o DAMPER BLADE NOTES: 1/6W HANDLE WITH LOCKING 1. LATCHES SHALL BE OF THE WEDGE TYPE TO CLOSE DOORS TIGHTLY. STANDARD RADIUS QUAy INSIDE END BEARING 2. HINGES ON THE ACCESS DOORS SHALL HAVE NON-CORROSIVE PINS. ELBOW W W NOTE: 1/8" [6mm] CLEARANCE SHORT RADIUS ELBOW SHORT RADIUS ELBOW 1. ALL VANED ELBOWS SHALL BE CONSTRUCTED AND INSTALLED AS DETAILED BY SIDE ELEVATION ALL AROUND SECTION DESIGNERS NOTES. The oriuseginal site purposens f specifications shall11 e prepare to and original site purpose for which they were prepared and publication thereof is expressly limited to such use. Re-use, WITH ONE VANE WITH TWO VANES SMACNA. reproduction, modification, or publication by any method, in 1. USE ACCESS DOORS ON AIR HANDLING UNITS AND DUCTWORK INSTALLED IN EQUIPMENT ROOMS. whole or in part, is prohibited and the recipient shall defend, 2. WHEN W1 DOES NOT EQUAL W2 VANE SHALL BE SINGLE VANE TYPE indemnify and hold The architect harmless from and against any NOTE: , claims and losses arising therefrom.Title and all ownership rights REGARDLESS OF W DIMENSION. NOTE: 2. USE ACCESS PANELS ON ALL EQUIPMENT AND DUCTWORK INSTALLED ABOVE FINISHED CEILINGS. to the plans and specifications remain in the architect without 1. THE INTERIOR SURFACE OF ALL RADIUS ELBOWS SHALL BE MADE ROUND. use,inclue.ding It is i be returned upon request to the architect.Any use,including visual contact,with these plans and specifications 3. ALL SINGLE VANES SHALL HAVE A 2" [50mm] RADIUS, 1 1/2" [40mm] 1 DELETE INSULATION STAND-OFF ON DUCTWORK WITHOUT EXTERIOR INSULATION. . shall constitute prima facie evidence of the acceptance of the 2. ALL STANDARD RADIUS ELBOWS SHOWN ON FLOOR PLANS MAY BE MADE SHORT MAXIMUM SPACE BETWEEN VANES AND A 3/4" [20mm] TRAILING EDGE. foregoing. RADIUS ELBOWS. ALL SHORT RADIUS ELBOWS SHALL HAVE VANES. VANES SHALL 4. WHEN W EQUALS W2 AND W1 IS GREATER THAN 20" [500mm] VANES SHALL 2. DETAIL SHOWS SINGLE BLADE DAMPER. DAMPER INSTALLATION SHALL BE SIMILAR drawn checked BE CONSTRUCTED, SUPPORTED AND FASTENED AS RECOMMENDED BY SMACNA. FOR MULTI-BLADE DAMPERS & ROUND DAMPERS. ACCESS DOOR DETAIL BE DOUBLE VANE TYPE. KDs MRM NO SCALE MECHANICAL U rn w MITERED ELBOW TURNING VANE DETAILS & Q RADIUS ELBOW VANE DETAIL DETAIL BALANCE DAMPER DETAIL SPECIFICATIONS 0 NO SCALE NO SCALE NO SCALE sheet N 00 M 0 1 Ln n U u7 0 U rn co v o date project no. 05/25/18 1708 w U O 0 a MECHANICAL SUMMARY- MECHANICAL SYSTEMS, SERVICE SYSTEMS, AND EQUIPMENT MECHANICAL GENERAL NOTES THERMALZONE 4A WINTER DRY BULB 160F 1 . THE DRAWINGS SHOW THE LOCATION AND ARRANGEMENT OF PIPING, DUCTS, AND EQUIPMENT, TOGETHER SUMMER DRY BULB 930F WITH DETAILS OF CONNECTIONS OF CERTAIN PRINCIPAL ITEMS. THE LAYOUT SHOWN SHALL BE FOLLOWED EQUIPMENT SCHEDULE c INTERIOR DESIGN CONDITIONS AS CLOSELY AS CIRCUMSTANCES WILL PERMIT, BUT THIS CONTRACTOR SHALL COOPERATE FULLY WITH OTHER SUB-CONTRACTORS AND TRADES WHILE INSTALLING DUCTS, PIPING, AND OTHER EQUIPMENT BECAUSE OF J WINTER DRY BULB 70OF � CLOSE SPACE LIMITS. IN CASE OF CONFLICT, NOTIFY DESIGNER BEFORE PROCEEDING WITH INSTALLATION. ITEM DESCRIPTION o SUMMER DRY BULB 750F w RELATIVE HUMIDITY 50% 2. THIS CONTRACTOR SHALL PROVIDE AND INSTALL ALL OFFSETS, FITTINGS, AND ACCESSORIES THAT MAY BE cn I0 w BUILDING HEATING LOAD NO ADDITIONAL LOAD REQUIRED FOR A COMPLETE AND PROPER INSTALLATION OR RECOMMENDED BY THE EQUIPMENT DAIKIN MODEL #RZQ18VJU8 OUTDOOR HEAT PUMP UNIT, 18,000 BTUH COOLING CAPACITY, 18.6 SEER, MANUFACTURER, WHETHER OR NOT THEY ARE SPECIFICALLY SHOWN OR SPECIFIED. 20,000 BTUH HEATING CAPACITY @ 47°F, 3.0 COP, 208V-1 PH., FURNISHED COMPLETE WITH: LOW AMBIENT `-' BUILDING COOLING LOAD NO ADDITIONAL LOAD SPLIT SYSTEM FCU KIT, WINTER START CONTROL, FILTER DRIER, REFRIGERANT LINE SET, EVAPORATOR FREEZE STAT, CRANKCASE �� Q MECHANICAL SPACING CONDITIONING SYSTEM 3. DUCTWORK SIZES INDICATED ON DRAWINGS ARE FREE INSIDE DIMENSIONS. #IU-1 HEATER, HIGH PRESSURE SWITCH, LOW PRESSURE SWITCH, COMPRESSOR START ASSIST, CYCLE PROTECTOR. n, UNITARY COMPARABLE PRODUCTS BY SANYO AND MITSUBISHI. APPROX. WEIGHT - 150 LBS. 222 cloister court Lz DESCRIPTION OF UNIT 4. MAXIMUM LENGTH OF FLEXIBLE DUCT IS SIX FEET (6'), UNLESS NOTED OTHERWISE. AND chapel hill, nc 27514 � DAIKIN MODEL #FAQ18PVJU, WALL MOUNTED SYSTEM FAN COIL, 18,000 BTUH COOLING CAPACITY, 20,000 919.401 .8586 HEATING EFFICIENCY REFER TO EQUIPMENT SCHEDULES FOR EFFICIENCIES 5. ALL VALVES, DAMPERS, CONTROLS, AND OTHER ITEMS REQUIRED FOR OPERATION OR MAINTENANCE ARE CONDENSING UNIT BTUH HEATING CAPACITY, 500(H) 400(L) CFM, 208V-1 PH., FURNISHED COMPLETE WITH: CEILING MOUNTING I COOLING EFFICIENCY TO BE ACCESSIBLE. #OU-1 KIT, INTEGRAL CONDENSATE PUMP, WALL MOUNTED REMOTE CONTROLLER, AND FILTER. COMPARABLE www.cro-ae.com o SIZE CATEGORY OF UNIT PRODUCTS BY SANYO AND MITSUBISHI. APPROX. WEIGHT - 31 LBS. BOILER 6. ALL SLEEVES, OUTLET BOXES, AND OTHER ROUGH-INS FOR SUCH ITEMS AS FIRE DAMPERS, PIPE TOTAL BOILER OUTPUT. IF OVERSIZED STATE REASON PENETRATIONS, LOUVERS, AND CONTROL ITEMS SHALL BE INSTALLED BY THIS CONTRACTOR. z NIA z CHILLER 7. PROVIDE AND INSTALL VOLUME CONTROL DAMPERS IN ALL NEW DUCTWORK AND AS OTHERWISE TOTAL CHILLER CAPACITY. IF OVERSIZED STATE REASON NIA REQUIRED IN EXISTING AT ALL SUPPLY MAIN AND BRANCH DUCT TAKE-OFFS. w I LIST EQUIPMENT EFFICIENCIES REFER TO EQUIPMENT SCHEDULES FOR EFFICIENCIES 8. PROVIDE AND INSTALL DUCT ACCESS DOORS AT ALL FIRE DAMPERS, AND DUCT SMOKE DETECTORS. REFER TO MECHANICAL AND DRAWINGS FOR DUCT SMOKE DETECTOR z LEGEND LOCATIONS.tq WA RKa + 9. THIS CONTRACTOR SHALL TAKE FIELD MEASUREMENTS BEFORE FABRICATING ANY DUCTS TO ENSURE THAT ® 275 CEILING SUPPLY DIFFUSER, TYPE AND CFM 24x12 RECTANGULAR DUCT, WIDTH x DEPTH DUCT SIZES SHOWN WILL FIT INTO AVAILABLE SPACE. IN CASE OF CONFLICT, NOTIFY THE DESIGNER .� F g��� BEFORE PROCEEDING. MENGINEERS CEILING RETURN GRILLE, TYPE AND CFM ROUND DUCT, DIAMETER Noland & McElrath Inc. c 450 10. ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION Reece, , H r 94 Main Street DUCT BALANCE DAMPER INSTRUCTIONS. o 250 CEILING EXHAUST GRILLE, CFM AND TYPE Canton, North Carolina 28716 PHONE`-' z11 . COORDINATE EXACT SIZES REQUIRED FOR ALL OPENING FOR DUCTWORK AND PIPING WITH SPACE MAIL@ NM-ENGIN NC CERT20 °'4y EAX:NEER.COO = 4054 1� O F8_1 DUCT TRANSITION MAIL@RNM-ENGINEERSWM ©2018 WWW.RNM-ENGINEERS.COM �a7 EF-3 EXHAUST FAN (NUMBER INDICATED) REQUIREMENTS, FIRE DAMPER INSTALLATION INSTRUCTIONS, AND THE MECHANICAL CONTRACTOR c� 1m o PRIOR TO FRAMING FOR THE PENETRATIONS. �� OT THERMOSTAT, MOUNT AT 48" A.F.F. DUCT TAKEOFF AT 45 DEGREES 12. COORDINATE EXACT LOCATION FOR ALL CEILING DIFFUSERS/GRILLES WITH REFLECTED CEILING PLAN, 'N CONNECT TO EXISTING ELECTRICAL SUB-CONTRACTOR'S LIGHTING LAYOUT, AND EXISTING CONDITIONS. DUCT SQUARE ELBOW WITH TURNING VANES 13. THIS CONTRACTOR TO BE RESPONSIBLE FOR PROVIDING AND INSTALLING ACCESS DOORS IN WALLS, EXISTING FIRE DAMPER (1-1/2 HOUR) SHEET ROCK CEILING, ETC., FOR ACCESS TO VALVES, BALANCE DAMPERS, FIRE DAMPERS, ETC. (AS REQUIRED). o COORDINATE WITH REFLECTED CEILING PLANS, AND CEILING SUB-CONTRACTOR, AND EXISTING CONDITIONS SD DUCT SMOKE DETECTOR (FURNISHED & ROUND DUCT ELBOW OR WIRED BY E.C.. INSTALLED BY M.C.) RECTANGULAR LONG RADIUS ELBOW 14. COORDINATE EXACT SIZE, LOCATION, APPURTENANCES, ETC. FOR ALL ROOF OPENINGS WITH EXISTING It 8 z CONDITIONS. UTILIZE EXISTING ROOF OPENINGS WHERE POSSIBLE. o _ <1OM Wv47°o MOTORIZED DAMPER - - z I EXISTING ZONE DAMPER 15. INSTALL LINTELS AT ALL LOUVER OPENINGS OR EXTEND EXISTING LINTELS AS REQUIRED. ,�,�Lt�ll WC,4]r F�"rlr FLOOR DRAIN OR HUB DRAIN FD 00 / HID a0 24x12 BY PLUMBING CONTRACTOR - - - - - - EXISTING RECTANGULAR DUCT, WIDTH x DEPTH Ic _ 8"� S SEAL ° cn 0- 1 HOUR FIRE WALL EXISTING ROUND DUCT, DIAMETER GENERAL MECHANICAL DUCTWORK NOTES G2 3 a W _ 2 HOUR FIRE WALL 1. THE DRAWINGS SHOW THE LOCATION AND ARRANGEMENT OF PIPING, DUCTS, AND EQUIPMENT, TOGETHER `,� . EXISTING DUCT BALANCE DAMPER WITH DETAILS OF CONNECTIONS OF CERTAIN PRINCIPAL ITEMS. THE LAYOUT SHOWN SHALL BE FOLLOWED "" f f�fr'lilCV�V`� OS EXISTING EMS TEMP. SENSOR, MOUNT AT AS CLOSELY AS CIRCUMSTANCES WILL PERMIT, BUT THIS CONTRACTOR SHALL REFER TO ARCHITECTURAL, 48" A.F.F. IN NEW LOCATION EXISTING DUCT TRANSITION STRUCTURAL, PLUMBING, AND ELECTRICAL DRAWINGS AND SHALL COOPERATE FULLY WITH OTHER CONTRACTORS AND TRADES WHILE INSTALLING DUCTS, PIPING, AND OTHER EQUIPMENT BECAUSE OF OH EXISTING HUMIDISTAT CLOSE SPACE LIMITS. IN CASE OF CONFLICT, NOTIFY DESIGNER BEFORE PROCEEDING WITH INSTALLATION. EXISTING DUCT TAKEOFF AT 45 DEGREES REFER TO ARCHITECTURAL DRAWINGS FOR EXACT BUILDING DIMENSIONS AND LOCATIONS OF PARTITION WALLS, DOORS, CHASES, CASEWORK, ETC. DO NOT SCALE MECHANICAL DRAWINGS FOR SUCH DIMENSIONS. EXISTING DUCT SQUARE ELBOW WITH 2. THIS CONTRACTOR SHALL PROVIDE AND INSTALL ALL OFFSETS, FITTINGS, AND ACCESSORIES THAT MAY BE TURNING VANES REQUIRED FOR A COMPLETE AND PROPER INSTALLATION, OR RECOMMENDED BY THE EQUIPMENT MANUFACTURER, WHETHER OR NOT THEY ARE SPECIFICALLY SHOWN OR SPECIFIED. EXISTING ROUND DUCT ELBOW OR 3. DUCTWORK SIZES INDICATED ON DRAWINGS ARE FREE INSIDE DIMENSIONS. RECTANGULAR LONG RADIUS ELBOW 4. MAXIMUM LENGTH OF FLEXIBLE DUCT IS SIX FEET (6'). 5. ALL VALVES, DAMPERS, CONTROLS, AND OTHER ITEMS REQUIRED FOR OPERATION OR MAINTENANCE ARE TO BE ACCESSIBLE. 6. ALL SLEEVES, OUTLET BOXES, AND OTHER ROUGH-INS FOR SUCH ITEMS AS FIRE DAMPERS, PIPE PENETRATIONS, LOUVERS, AND CONTROL ITEMS SHALL BE INSTALLED AS THE BUILDING CONSTRUCTION PROGRESSES. 7. PROVIDE AND INSTALL VOLUME CONTROL DAMPERS AT ALL SUPPLY MAIN AND BRANCH DUCT TAKE-OFFS. O 8. PROVIDE AND INSTALL DUCT ACCESS DOORS AT ALL SMOKE DAMPERS, FIRE DAMPERS, AND DUCT SMOKE DETECTORS. REFER TO MECHANICAL AND ELECTRICAL DRAWINGS FOR DUCT SMOKE DETECTOR GRILLE & DIFFUSER SCHEDULE LOCATIONS. MANUFACTURER 9. THIS CONTRACTOR SHALL TAKE FIELD MEASUREMENTS BEFORE FABRICATING ANY DUCTS TO ENSURE THAT Q� -- SYMBOL TYPE LOCATION MODEL SIZE CFM REMARKS DUCT SIZES SHOWN WILL FIT INTO AVAILABLE SPACE. IN CASE OF CONFLICT, NOTIFY THE DESIGNER BEFORE PROCEEDING. � � E CEILING PRICE 6o OFF-WHITE FINISH LAY-IN SCD NA SUPPLY 10. ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION 24x24 100 INSTRUCTIONS. 0 B SUPPLY CEILING PRICE 8o OFF-WHITE FINISH 11. COORDINATE LOCATIONS OF ALL FLOOR DRAINS WITH PLUMBING CONTRACTOR, PRIOR TO SLABS BEING (� U LAY-IN SCD 24x24 230 POURED. �� z CEILING PRICE 100 OFF-WHITE FINISH 12. COORDINATE EXACT LOCATION FOR ALL CEILING DIFFUSERS/GRILLES WITH ARCHITECTURAL REFLECTED C SUPPLY LAY-IN SCD 2424 415 CEILING PLAN AND ELECTRICAL CONTRACTORS LIGHTING LAYOUT. 0 CY) CEILING PRICE 12o OFF-WHITE FINISH 13. ALL EMS SENSORS AND OTHER FIELD DEVICES MOUNTED ON WALLS TO BE PROTECTED FROM O D SUPPLY LAY-IN SCD 550 DAMAGE AS REQURED - INSTALL LEXAN COVERS, WIRE GUARDS, OR SIMILAR AS REQUIRED. 0 2424 COORDINATE CONDITIONS IN THE FIELD. �y O V � E SUPPLY SIDEWALL PRICE 8x4 110 OFF-WHITE FINISH 14. THE MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING TO THE GENERAL CONTRACTOR Q = THE QUANTITY, SIZE AND LOCATIONS OF ALL ACCESS DOORS IN WALLS, DRYWALL CEILINGS, ETC. FOR ACCESS TO VALVES, BALANCE DAMPERS OR OTHER EQUIPMENT AS REQUIRED. COORDINATE PRICE OFF-WHITE FINISH THIS WORK WITH THE REFLECTED CEILING PLANS. ALL VALVES OR OTHER DEVICES LOCATED F SUPPLY SIDEWALL 510 14x8 415 ABOVE THE CEILING SHALL BE LOCATED IN ACCESSIBLE CEILINGS WHEREVER POSSIBLE. VERIFY no. revisions LOCATION OF ALL VALVES IN INACCESSIBLE CEILINGS OR CHASES WITH THE ARCHITECT PRIOR RETURN/ CEILING PRICE 6x6 2x12 OFF-WHITE FINISH, SQUARE TO ROUND TO INSTALLATION. MECHANICAL CONTRACTOR TO PROVIDE AND INSTALL ALL ACCESS DOORS. G EXHAUST SURFACE APPDR 100 TRANSITION AS REQUIRED 15. COORDINATE EXACT SIZE, LOCATION, APPURTENANCES, ETC. FOR ALL ROOF OPENINGS WITH GENERAL 1 CONTRACTOR. RETURN/ CEILING PRICE 8x8 OFF-WHITE FINISH, SQUARE TO ROUND H EXHAUST LAY-IN APDDR 280 TRANSITION AS REQUIRED 16. REFER TO INTERIOR LINTEL SCHEDULE ON STRUCTURAL DRAWINGS AND COORDINATE ALL OPENINGS WITH 24x24 GENERAL CONTRACTOR PRIOR TO WALL CONSTRUCTION. J RETURN/ CEILING PRICE 10x10 OFF-WHITE FINISH, SQUARE TO ROUND 420 TRANSITION AS REQUIRED 17. REFER TO STRUCTURAL DRAWINGS AND DETAILS FOR PERMISSIBLE LOCATIONS AND METHODS FOR EXHAUST LAY-IN APDDR 24x24 HANGING DUCTWORK FROM STRUCTURE. ALL DUCTWORK HANGERS TO BE WITHIN 6" OF PANEL POINTS RETURN/ CEILING PRICE 12x12 OFF-WHITE FINISH, SQUARE TO ROUND OF JOISTS. DO NOT WELD DUCT HANGERS/SUPPORTS TO STRUCTURE WITHOUT PRIOR APPROVAL FROM K THE STRUCTURAL ENGINEER AND GENERAL CONTRACTOR. EXHAUST LAY-IN APDDR 24x24 1000 TRANSITION AS REQUIRED the 18. COORDINATE EXACT SIZES REQUIRED FOR ALL OPENING FOR DUCTWORK AND PIPING WITH SPACE Thenal use site purpose for ithey wlberprepred and OFF-WHITE FINISH, SQUARE TO ROUND REQUIREMENTS, FIRE DAMPER INSTALLATION INSTRUCTIONS, STRUCTURAL DRAWINGS, AND THE GENERAL original Site purpose far which they were prepared and RETURN/ PRICE 16x12 publication thereof is expressly limited to such use. Re-use, EXHAUST SIDEWALL 530 450 TRANSITION AS REQUIRED CONTRACTOR, PRIOR TO FRAMING FOR THE PENETRATIONS. reproduction, modification, or publication by any method, in whole or in part, is prohibited and the recipient shall defend, indemnify and hold the architect harmless from and against any OFF-WHITE FINISH, SQUARE TO ROUND 19. THE MECHANICAL CONTRACTOR SHALL THOROUGHLY COORDINATE DUCT / PIPE PENETRATIONS claims and losses arising therefrom.Title and all ownership rights RETURN CEILING PRICE 1202 to the plans and specifications remain in the architect without M / SURFACE APDDR 600 TRANSITION AS REQUIRED AT STRUCTURAL SHEAR WALLS / SHEAR BRACING WITH STRUCTURAL DRAWINGS AND BUILDING STEEL prejudice. It is to be returned upon request to the architect.Any EXHAUST 20x2O SHOP DRAWINGS. INSTALL LINTELS AS REQUIRED. use,including visual contact,with these plans and specifications shall constitute prima facie evidence of the acceptance of the NOTES foregoing. 20. ALL CONTROL DEVICES (SENSORS, STATS, SWITCHES, ETC) TO GENERALLY BE LOCATED ADJACENT TO LIGHT 1 . ALL GRILLES / DIFFUSERS SERVING TOILETS AND JAN. CLOSETS TO HAVE ALUMINUM CONSTRUCTION. SWITCHES IN EACH ROOM, UNLESS NOTED OTHERWISE. GENERALLY, THIS SHOULD BE AS CLOSE TO DOORSTRIKE drawn checked 2. ALL GRILLE DESIGNATIONS MAY NOT BE UTILIZED ON THIS PROJECT. AS POSSIBLE. 3. APPROVED EQUALS BY CARNES, TITUS, AND KRUEGER. KDS MRM 4. ALL GRILLES WITH RADIATION DAMPERS TO HAVE STEEL CONSTRUCTION. MECHANICAL U NOTES, LEGEND, & n Q rn a SCHEDULES a 0 sheet N U CID co MO . 2 Ln co 0 U rn co v ate project no. :z 05/25/18 1708 w U O 0 p Note. Existing ductwork and zone dampers shown on drawings are based on the Owner's existing drawings. Contractor to field verify exact location and configuration of existing duct systems and • •I I,a coordinate connections as required. J z 0 � w z N40 U w ry I w c� � 222 cloister court A B C D E F G H J K L M N P chapel hill, nc 27514 " ry 919.401 .8586 NEW OU-1 OUT 0 R UNIT SET N 3" CONCRETE NOTE: www.cro-ae.com U HOUSEKEEPING PAD. ROUTE NEW REFRIGERANT PIPING AND EXISTING SUPPLY GRILLES TO 0 o CONTROL WIRIN T ROU H OUTSIDE WALL INTO MECHANICAL BE REMOVED AND REPLACED 1 Q 1 ROOM, UP TO A 0 E CEILING AND OVER O INSOOR UNIT WITH NEW (TYPICAL) IU-1. PIPING AND WIRINGTO BE PLENUM RATED. 0 z OU-1 z w B 8000 TYPI \\ / Xi C 15 GRILLEI-SEEP UM URN \T-/� i -yi 1/ B U �• E Z/1 300 g lOnpt C CONFERENC / EXIS „J, DETAIL XIS AHU-�T=� ASST P # PUBLIC D DLr AS D AS»5 230 LIBRARY OFTC - E 4� Ml x 1 /i 1 80 196 SF TYPICAL RET N 116 117 S- 309 SF C Rd \ 8 0 23 � w S7M ____��r� / TYPE TYPE GRILLE OPEN » TYPE » 8"0 „ » T A U-1 rr » " 80 100 '� H 10 0 SPACETO EABOVE NUM » » �i —"J P 3.5 ' •° � NJ PE A r } 4 Z S S ENGINEERS z B 100 L —L� °� H " " 150 �� ______ % 1 s_T 8"0 H TYPE Reece, Noland & McElrath, Inc. t _1 Z4 — --- ----- , » c� L 18x14 J L L H INTERVIE 94 Main Street N o _ S S B 4 Canton, North Carolina 28716 » » rr rr I PHONE:828-492-0677 NC CERT.NO.C-0149 FAX:828-492-1054 = z ANTI I M W ��� » n PE I 150 @RN - ©2018 WWW.RNM-ENGINEERS.COM O I MAIL M ENGINEERS,COM TYPICAL VVT DAMPERS TO N OR 8 TYPE REMAIN. REBALANCE TO NEW LTJ „ » �- nE » » H 0 OrFEE/ „ Im o CFM SHOWN ON DRAWING. C tFEREN E DOOR & TERNS)H _�� L L P If4 HASST PD # ASST PD r IN6 T ATOR IC�iE E 8 ALL NEW SUPPLY DUCT 325 112 SF 1 F 125 SF 124 F 1 125 991S » 270 B X I B I B F "' B NECK SIZE (TYPICAL) 1� o CR OPENING 7 8 0 B B - 8RUNOUTS TO MATCH GRILLE 1 Q 10"0 » 8 0 J I � J no ! c� 170 190 1 1 190 M 1 I x l 190 �� N II N n S ----J 1 L� -- VIEW #1 --------- -- ----- 1 3 0 °� 26x18 OX18 16x14--� o SHARED C �_ ----- ----------- ----- -------- -- L 150 --- ---DE OSITIO » TYPE" JEW 80 NEW WORK ROOM rr rr B10 Q) I 35 SF1 209 SF I F E 1 OFF #2 » OFB( SUPPLY S RA 200 325 i C 0 i 165 LF SHELVING TYPE SE 1 3 --- C200 ` �� B • CD z �3 270 LNJ »H» 1 5 L T J 165 1 - - ��' M 195 I 8 0 IFil COORDINATE WIRING TO NEW _. 19 H TYPE SENSOR LOCATIONS-WITH WITH � Q i TYPICAL EXf�TVNG ZO E i 25 TYPE 9111, 10, L J I�1 1 � o DAMPER TODREMAIN TYPE •II - 5 - - - H IU-1S 8 0 C „ „ MODULAR NIJ XIS I GTT FGR. n TYPE J11 S CONTROL WIRING AS REQUIRED o EXISTING - A R B J " ELECTRIC-"' TO JANITORS SI K 200 8"0 FOR A COMPLETE INSTALLATION. I 1 0 c S �7 TYPE (TYPICAL) e SEA L o E%� ■^ 8»0 On0 S S C r 1 it iE iE/ ° TYPE ,>J" _ o 02 39 S y ¢, �, ■ » TYP RECEPTION LJ° C �frf'Q w4ev.pa4vva ■ TINS 0 EXISTING EXISTING ■o CE TYPE "fd OFFICE OFFICE WAITING / ; ISTING EXHAUS TO Z 290 TYPICAL RETURN GRILLE ri J J° M _.il I RE r OPEN TO PLENUM SPACE f'�rrzr�LLLLti�L TYP I CLOSET ABOVE-SEE DETAIL 205 so B B 10"0 C �r-T 206 FP ��° rJn 285 L J �» 41 Si0"0 175 170 �- 7 - - - - -- -- - - - ---- - - 7 LOBBY/ TYPE C WAITII "K" 235 I RECEPTI0 C 8"0 12x12 j CLERI 298 290 B C I 10"0 200 235 10"0 10"0 N I N S N I S Q r V IEXIS G I I I I — V. _.J ! 11 I �I» 0 —J "0 /- 1 rZ 4 8" 11 J O TYPE _ CFM 1E'�- ---- TOR ST'�"�G7I • � v k. -----......... I 0" 4J� EXH J 10„� --106 B 0 S 1 O 1 8"0 RECEP ON J 1 1 A L 102 0 B �1 100 8rr B • -F- 150 i-�TORAGE 1 150 1 I I 110 I N 1 I i TYPE 6"0 TYPE 10"0 Q OFFICE - 8" i i »G» C i 10 3 300 N - -----FZ2J-- 8"0C. 104TFRENCE W r0 200 8»0 S B 8„0 1 00 SF v U 110 1 co B • -��` z '> X 1 110 1 , � E TYP 8 0 1 »1r „H>, --- �+ (RAGE T� ! 1 10"0 ' U Oj TYPE S �_� SF12 H" S % S O " " - L OFFICE H 10 11-1 PE 11 O rrHrr OFFICE —Q 200 8"0 14"o — 14"o O O 1 B 00 C MEN 0 8 0 B 250 110 I "0 TYPE g"- FILE - A8"0 OFFICE "G" T 107 no. revisions "H' �p E 1 -- 100rZ2�- T09 1 OFFICE S 14 0 TyrPE C I 6 12 S - TYPE C 10 0 8"0 TYP » » 0»0 B 270 TYPE 88 = "J" TRAININa B » 9 � 6 LZ4J -� COIVFERENOU "H' 0"0 E MENT 10 8 8"0 » I I� r OFFIC H B �11 A S 1 135 200 F_- 100 M6 TYPE J 1 I Tp AHU-2 I � I S 'Jn The use of these plans and specifications shall be restricted to the _ — — 1 original site purpose for which they were prepared and publication thereof is expressly limited to such use. Re-use, i 1 2 0 _1 2 0 F----� TI C reproduction, modification, or publication by any method, in _LZ3�—� � 240 whole or in part, is prohibited and the recipient shall defend, 0 L J ul J- 1 6 0 �J indemnify and hold the architect harmless from and against any r claims and losses arising therefrom.Title and all ownership rights $» cfl rr rr to the plans and specifications remain in the architect without (14 .5 Id-0 — — —T �� �� —T prejudice.It is to be returned upon request to the architect.Any —F T 7 \T / /-F I /I 1 use,including visual contact,with these plans and specifications n » 1 05 \1 / I L X,11 J 46x 18 24 Zj1 1 — 1 1/ shall constitute prima facie evidence of the acceptance of the S «J r foregoing. ------ _ + Jq U-2� -a B ----n- B E� i ��, �LZ�1J�1 I /I 1 — —, 1ai B 170 175 r �I / \I �_yl �/ J drawn checked f 5E 195 g"0 12"0 r -�_ I� M Cft,� l KDS MRM 1 — ----Z z — ROO 15 X13� -� MECHANICAL 00 DUCTWORK PLAN w 16 a a QD 0 CN First Level Floor Plan- Ductwork sheet � M 1 .1 Scale: 1/8" = 1'-0" U u7 00 0 U rn QD co v ate project no. Q 05/25/18 1708 w L) U O C] DocuSign Envelope ID:4659CD86-5C5C-4726-9F10-AA69EA5C98C1 ® DATE(MM/DD/YYYY) Ill 1 CERTIFICATE OF LIABILITY INSURANCE 12/5/2017 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT NAME: Crystal Ireland FAX Business Insurers of Carolinas A/C No Ext: (919)968-4611 A/C No: (919)968-8991 800 Eastowne Drive, Suite 208 E-MAIL cireland@business-insurers.com ADDRESS: PO Box 2536 - INSURER(S)AFFORDING COVERAGE NAIC# Chapel Hill NC 27515-2536 INSURERA Penn National Ins. Companies 14990 INSURED INSURERS Bridgefield Casualty Insurance 10335 Warren-Hay Mechanical Contractors Inc INSURERC: Sheet Metal Duct Suppliers LLC INSURER D: PO Box 818 INSURER E Hillsborough NC 27278 INSURERF: COVERAGES CERTIFICATE NUMBER:CL1712520606 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR - ADDL SUBR -- POLICY EFF POLICY EXP -- LTR TYPE OF INSURANCE INSD WVD POLICY NUMBER MM/DD/YYYY MM/DD/YYYY LIMITS X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 1,000,000 A CLAIMS-MADE 1 OCCUR DAMAGE TO RENTED 100,000 PREMISES Ea occurrence $ CX90726312 12/31/2017 12/31/2018 MED EXP(Any one person) $ 10,000 PERSONAL&ADV INJURY $ 1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 2,000,000 X POLICY PRO- ❑ LOC PRODUCTS-COMP/OP AGG $ 2,000,000 JECT OTHER: AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT Ea accident _ $ 1,000,000 A X ANY AUTO BODILY INJURY(Per person) $ ALL OWNED SCHEDULED AX90726312 12/31/2017 12/31/2018 BODILY INJURY(Per accident) $ AUTOS AUTOS NON-OWNED PROPERTY DAMAGE X HIRED AUTOS X AUTOS Per accident $ Endorsements $ X UMBRELLA LIAB X OCCUR EACH OCCURRENCE $ 3,000,000 A EXCESS LIAB CLAIMS-MADE AGGREGATE $ 3,000,000 DIED RETENTION$ UL90726312 12/31/2017 12/31/2018 $ WORKERS COMPENSATION X PER OTH- AND EMPLOYERS'LIABILITY `,/N STATUTE ER _ _ _ ANY PROPRIETOR/PARTNER/EXECUTIVE E L EACH ACCIDENT $ 500,000 OFFICER/MEMBER EXCLUDED? N/A -------- ----- ---- B (Mandatory in NH) 0196-40173 12/31/2017 12/31/2016 E.L.DISEASE-EA EMPLOYE $ 500,000 If yes,describe under ---- --_-- _----"-"---- DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ 500,000 A Leased/Rented Equipment CX90726312 12/31/2017 12/31/2018 LIMIT $50,000 DEDUCTIBLE $500 DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if more space is required) CERTIFICATE HOLDER CANCELLATION abarnes@orangecountync.gov SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE Orange County THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN PO Box 8181 ACCORDANCE WITH THE POLICY PROVISIONS. Hillsborough, NC 27278 AUTHORIZED REPRESENTATIVE J Knauff, IV/IRELOI ©1988-2014 ACORD CORPORATION. All rights reserved. ACORD 25(2014/01) The ACORD name and logo are registered marks of ACORD INS025(201401) DocuSign Envelope ID:4659CD86-5C5C-4726-9F10-AA69EA5C98C1 ACORO® CERTIFICATE OF LIABILITY INSURANCE DATE(MMIDD/YYYY) 12/28/2018 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Crystal Ireland Business Insurers of Carolinas PAICNNo E. , (919)968-4611 (A//C,No): (919)968-8991 800 Eastowne Drive,Suite 208 E-MAIL ADDRESS: cireland@business-insurers.com PO BOX 2536 INSURER(S)AFFORDING COVERAGE NAIC# Chapel Hill NC 27515-2536 INSURER A: Acadia Insurance Company 31325 INSURED INSURER B: Brldgefield Casualty 10335 Warren-Hay Mechanical Contractors Inc INSURERC: Sheet Metal Duct Suppliers LLC INSURER D: PO BOX 818 INSURER E: Hillsborough NC 27278 INSURERF: COVERAGES CERTIFICATE NUMBER: CL18122824327 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES,LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR AUULbUBK POLICY EFF POLICY EXP LTR TYPE OF INSURANCE INSD WVD POLICY NUMBER MM/DD/YYYY) (MM/DD/YYYY) LIMITS X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 1,000,000 CLAIMS-MADE �OCCUR PREMISES Ea occurrence $ 100,000 MED EXP(Any one person) $ 10,000 A CPA4429328 12/31/2018 12/31/2019 PERSONAL&ADV INJURY $ 1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 2,000.000 X POLICY X PRO LOC PRODUCTS-COMP/OP AGO $ 2,000,000 JECT OTHER: $ MBINED SINGLE LIMIT $ 1,000,000 EAUTOMOBILE LIABILITY CCaO accident X ANY AUTO BODI LY I NJURY(Per person) $ A OWNED SCHEDULED CPA4429328 12/31/2018 12/31/2019 BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS X HIRED IX NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY AUTOS ONLY Per accident Endorsements $ X UMBRELLA LIAB X OCCUR EACH OCCURRENCE $ 3,000,000 A EXCESS LIAB CLAIMS-MADE CPA4429328 12/31/2018 12/31/2019 AGGREGATE $ 3,000,000 DED I I RETENTION$ $ WORKERS COMPENSATION PER OTH- AND EMPLOYERS'LIABILITY X STATUTE X Y!N ER B ANY PROPRIETOR/PARTNER/EXECUTIVE NIA 0196-40173 12/31/2018 12/31/2019 E.L.EACH ACCIDENT $ 500,000 OFFICER/MEMBER EXCLUDED? FTJ (Mandatory in NH) E.L.DISEASE-EA EMPLOYEE $ 500,000 If yes,describe under 500,000 DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ Leased/Rented Equipment LIMIT $50,000 A Installation Floater CPA4429328 12/31/2018 12/31/2019 LIMIT $500,000 DESCRIPTION OF OPERATIONS/LOCATIONS I VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if more space is required) CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF,NOTICE WILL BE DELIVERED IN Orange County ACCORDANCE WITH THE POLICY PROVISIONS. PO Box 8181 AUTHORIZED REPRESENTATIVE Hillsborough NC 27278 @ 1988-2015 ACORD CORPORATION. All rights reserved. ACORD 26(2016103) The ACORD name and logo are registered marks of ACORD