Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2018-347-E AMS - Hoffman and Hoffman HVAC Annex
DocuSign Envelope ID: AOD5DO06- 1BO4- 4F7B- 96D7- OF7A4E374317 [Departmental Use Only] TITLE BOE HVAC FY 2018 -19 NORTH CAROLINA CONSTRUCTION AGREEMENT UNDER $250,000.00 ORANGE COUNTY THIS CONSTRUCTION AGREEMENT (hereinafter called "Agreement "), made as of the 31st day of July, 2018, by and between Hoffman & Hoffinan, Inc , (hereinafter called the "Contractor "), and Orange County, a body politic and a political subdivision of the State of North Carolina, (hereinafter called the "Owner "). WITNESSETH: That the Contractor and the Owner, for the consideration herein named, agree as follows: 1. CONTRACT DOCUMENTS; PRIORITY The Contract Documents consist of this Agreement, the Request for Proposals, Proposal, Construction Drawings, and Written Specifications. The Contract Documents form the Contract. In the event of any inconsistency between or among the Contract Documents the Contract Documents shall be interpreted in the following order of priority: a. This Agreement. b. Designer Approved Bulletins and/or Field Orders. c. Request for Proposals and addenda thereto. d. Proposal. 2. SCOPE OF WORK The Contractor shall furnish and deliver all of the materials, and perform all of the work required by this Agreement within the time period stipulated in a written Notice -to- Proceed to be executed by the Contractor and Owner and in accordance with the following enumerated documents, which are made a part hereof as if fully contained herein: a. Construction Drawings prepared by RN &M Engineers (Sheet M0.2 dated 5/7/18) b. Written specifications prepared by the project engineer. c. Hoffman & Hoffman Inc proposal dated April 24, 2018 which fully describes the work to be performed. Such work will hereafter be called the "Work ". d. Related documents listed under Section 1 above. 3. TERM AND SCHEDULING Revised 10/17 1 DocuSign Envelope ID: AOD5DO06- 1BO4- 4F7B- 96D7- OF7A4E374317 a. The Contractor agrees to commence work pursuant to the written Notice to Proceed. b. The Contractor agrees to complete substantially all Work by September 1, 2018. c. Time is of the essence with respect to all dates specified in the Contract Documents as Completion Dates. d. The Contractor shall perform the Work in the time, manner, and form required by the Contract Documents and as stipulated in a written Notice -to- Proceed to be executed by the Contractor and Owner. e. It is expressly understood that the Owner will employ other contractors to perform work as a part of the Project whose work will be performed simultaneously and sequentially with the performance of the Work by the Contractor. It shall be necessary for the Contractor to coordinate its activities with such other contractors, particularly with respect to access to work areas, storage of materials and other common facilities. f. Should the Owner determine that the Contractor is behind schedule Owner may require, at no additional cost to the Owner, the Contractor to expedite and accelerate its efforts, including providing additional resources and working overtime, as necessary, to perform the Work in accordance with the approved project schedule. 4. STANDARD OF CARE a. The Contractor shall exercise reasonable care and diligence in performing the Work in accordance with the highest generally accepted standards of this type of Contractor practice throughout the United States and in accordance with applicable federal, state and local laws and regulations applicable to the performance of these services. Contractor is solely responsible for the professional quality, accuracy and timely completion and/or submission of all work. b. The Contractor shall not load or permit any part of the Work to be loaded with a weight that will endanger its safety, intended performance or configuration. c. Contractor shall be responsible for all errors or omissions caused by its employees, agents, contractors, or assigns in the performance of the Agreement. Contractor shall correct any and all errors, omissions, discrepancies, ambiguities, mistakes or conflicts at no additional cost to the Owner. d. Contractor is an independent contractor of Owner. Any and all employees of the Contractor engaged by the Contractor in the performance of any work or services required of the Contractor under this Agreement, shall be considered employees or agents of the Contractor only and not of the Owner, and any and all claims that may or might arise under any workers compensation or other law or contract on behalf of said employees while so engaged shall be the sole obligation and responsibility of the Contractor. e. If activities related to the performance of this Agreement require specific licenses, certifications, or related credentials Contractor represents that it and/or its employees, agents and subcontractors engaged in such activities possess such licenses, certifications, Revised 10/17 2 DocuSign Envelope ID: AOD5DO06- 1BO4- 4F7B- 96D7- OF7A4E374317 or credentials and that such licenses certifications, or credentials are current, active, and not in a state of suspension or revocation. 5. PAYMENT & TAXES a. The Owner hereby agrees to pay to the Contractor for the faithful performance of this Agreement, and the Contractor hereby agrees to perform all of the Work for a sum not -to- exceed Sixty Five Thousand Seven Hundred Seventy Two Dollars ($65,772.00). Not later than the fifth (5th) day of each calendar month the Contractor shall submit to the Owner's Representative, generally the architect if an architect is retained on the Work, a Request for Payment for work done during the previous calendar month. i. The Request for Payment shall be in form of a standardized invoice or AIA Document G702 -703 appropriately addressed to Owner's Representative at PO Box 8181, Hillsborough NC 27278 and shall show substantially the value of work done during the previous calendar month. ii. The amount due for payment shall be ninety -five percent (95 %) of the value of work completed since the last Request for Payment and this amount shall be paid by the Owner on or before the last business day of the month. Owner shall retain five percent (5 %). 1. Upon Owner's Representative's certification that ninety percent (90 %) of the Work has been satisfactorily completed retainage may be discontinued. Retainage may be discontinued, at Owner's Discretion, so long as work continues to be completed satisfactorily and on schedule. iii. Final payment shall not be due to the Contractor until thirty (30) days after one hundred percent (100 %) of the Work, including punch list work, has been satisfactorily completed and an appropriate affidavit as required in Section 7(c) below has been received by Owner. b. Should Owner reasonably determine that Contractor has failed to perform the Work related to a Request for Payment, Owner, at its discretion may provide the Contractor ten (10) days to cure the breach. Owner may withhold the accompanying payment without penalty until such time as Contractor cures the breach. i. Should Contractor or its representatives fail to cure the breach within ten (10) days, or fail to reasonably agree to such modified schedule, Owner may immediately terminate this Agreement in writing, without penalty or incurring further obligation to Contractor. ii. This section shall not be interpreted to limit the definition of breach to the failure to perform the Work related to a Request for Payment. c. The Contractor has included in the Contract Price and shall pay all taxes assessed by any authority on the Work or the labor and materials used therein. It shall be the Contractor's responsibility to furnish the Owner documentary evidence showing the materials used and sales and use tax paid by the Contractor and each of its subcontractors. 6. INSURANCE AND BONDS a. Minimum requirements — Contractor shall obtain, at its sole expense, Commercial General Liability Insurance, Automobile Insurance, Workers' Compensation Insurance, and any additional insurance as may be required by Owner's Risk Manager as such insurance requirements are described in the Orange County Risk Transfer Policy and Orange County Minimum Insurance Coverage Requirements (each document is incorporated herein by Revised 10/17 3 DocuSign Envelope ID: AOD5D006- 1B04- 4F7B- 96D7- OF7A4E374317 reference and may be viewed at http: / /www.oran eg countync. o�partments /purchasing division /contracts.php). If Owner's Risk Manager determines additional insurance coverage is required such additional insurance shall be designated here N/A (if no additional insurance required mark N/A as being not applicable). Contractor shall not commence construction work until such insurance is in effect and certification thereof has been received by the Owner's Risk Manager. b. Performance Bonds — Contractor shall furnish bonds covering the faithful performance of the Contract and payment of all obligations arising under any of the Contract Documents or related in any way to the Work. Contractor shall immediately furnish a copy of such bonds to any requesting person who appears to be a potential beneficiary of bonds covering payment obligations arising under any of the Contract Documents. This subsection 6(b) applies only to Contracts of fifty thousand dollars ($50,000.00) or more where the total cost for the project is three hundred thousand dollars ($300,000.00) or more. 7. INDEMNITY a. The Contractor shall indemnify, without limitation, and hold harmless to the maximum extent permitted by law the Owner and its agents and employees from and against any and all claims, damages, losses and expenses, including attorney's fees, arising out of or resulting from the performance or nonperformance of the Work, provided that any such claim, damages, loss or expense (A) is attributable to bodily injury, sickness, disease or death or injury to, or destruction of, property, including the loss of use resulting therefrom; and (B) is caused in whole or in part by any breach of any provision of the Agreement or by any negligent or wrongful act or omission of the Contractor, any Subcontractor, or supplier of the Contractor, anyone directly or indirectly employed by any of them or anyone for whose acts any of them may be liable. The indemnification obligation under this paragraph shall not be limited in any way by any limitation of the amount or type of damages, compensation or benefits payable by or for the Contractor or any subcontractor under workers' compensation acts, disability benefits acts or other employee benefit acts. b. The Contractor shall indemnify and hold harmless Owner from any lien of whatever type through the purchase of appropriate bonds and insurance as designated in Section 6 above. In the event any such lien is filed against Owner's property Contractor shall, through such bonds and insurance or at Contractors expense, defend Owner against all such claims of lien. c. Upon completion of the Work the Contractor shall execute an affidavit stating there are no unpaid debts for any work that has been done or materials that have been furnished to the Project prior to and as of the date of substantial completion and further stating that Contractor shall indemnify, save and protect Owner and Owner's lender, if any, harmless from and against any and all claims, liabilities, losses, damages, causes of action, and expenses (including court costs and reasonable attorney's fees related thereto) arising out of, in connection with, or resulting from any such debts and liens. Such indemnification shall be in a form and substance acceptable to Owner. d. By executing this Agreement Contractor agrees to abide by and be bound by the indemnification provisions herein and of Section 7(c) specifically. Revised 10/17 4 DocuSign Envelope ID: AOD5DO06- 1BO4- 4F7B- 96D7- OF7A4E374317 8. DISPUTE RESOLUTION AND GOVERNING LAW a. Any dispute with respect to any provision of, or the performance or non - performance of, this Agreement shall be subject to the Dispute Resolution Rules and Procedures for Orange County Design, Building Construction, Renovation, and Repair Projects. The policy is incorporated herein by reference and may be viewed at http: / /www.oran eg countync.gov /departments /purchasing _division /contracts.php). b. The laws of the State of North Carolina shall apply to the interpretation and enforcement of this Agreement. Any and all suits or actions to enforce, interpret or seek damages with respect to any provision of, or the performance or nonperformance of, this Agreement or the Contract shall be brought in the General Court of Justice of North Carolina sitting in Orange County, North Carolina and it is agreed by the parties that no other court shall have jurisdiction or venue with respect to such suits or actions. c. Notice of any claim by Owner or Contractor must be initiated by written notice to the other Party within thirty (30) days of the occurrence of the event giving rise to the claim or within thirty (30) days of the discovery of the event or condition giving rise to the claim, whichever is later. i. Should any claim be made, regardless of whether such claim is made by Owner or Contractor, Contractor shall continue to faithfully and diligently perform the Work in such a manner as to meet all scheduled timelines. Any failure to faithfully and diligently perform the Work may be deemed, by the Owner, a breach of the Contract. ii. If a claim is made such claim shall be made to the initial decision maker, if applicable, who may request more supporting data, reject the claim in whole or in part, approve the claim in whole or in part or advise the parties the claim is unable to be resolved. iii. If a claim is made by the Owner the Owner may, but is not obligated to, notify the surety. 9. NON — APPROPRIATION a. Contractor acknowledges that Owner is a governmental entity, and the validity of this Agreement is based upon the availability of public funding under the authority of its statutory mandate. b. In the event that public funds are unavailable and not appropriated for the performance of Owner's obligations under this Agreement, then this Agreement shall automatically expire without penalty to Owner immediately upon written notice to Contractor of the unavailability and non - appropriation of public funds. It is expressly agreed that Owner shall not activate this non - appropriation provision for its convenience or to circumvent the requirements of this Agreement, but only as an emergency fiscal measure during a substantial fiscal crisis. In the event of a change in the Owner's statutory authority, mandate and /or mandated functions, by state and/or federal legislative or regulatory action, which adversely affects Owner's authority to continue its obligations under this Agreement, then this Agreement shall automatically terminate without penalty to Owner upon written notice to Contractor of such limitation or change in Owner's legal authority. Revised 10/17 5 DocuSign Envelope ID: AOD5DO06- 1BO4- 4F7B- 96D7- OF7A4E374317 10. NOTICES Any notice required by this Agreement shall be in writing and delivered by certified or registered mail, return receipt requested to the following: Owner: Contractor: Orange County Hoffman & Hoffman, Inc Attn: Angel Barnes 2741 NOBLIN RD, SUITE 100 P.O. Box 8181 RALEIGH, NC 27604 Hillsborough, NC 27278 11. MISCELLANEOUS a. Duties and Obligations imposed by the Contract Documents shall be in addition to any Duties and Obligations imposed by state, federal or local law, rules, regulations and ordinances. b. No act or failure to act by the Owner or Contractor shall constitute a waiver of any right or duty granted them under the Contract Documents, nor shall any act or failure to act constitute any approval except as specifically agreed in writing. c. The Work shall be tested and inspected as required by the Contract Documents and as required by law. Unless prohibited by law the costs of all such tests and inspections related to state and federal codes such as ADA, Administrative, Electrical, Plumbing, Mechanical and Building Codes shall be borne by the Contractor. The costs for material and structural testing shall be conducted by an independent third party at the expense of the Owner. Delays related to any of the aforementioned tests and inspections shall not be grounds for delaying the completion of the work. If any such tests and inspections reveal deficiencies in the Work such that the Work does not comply with terms or requirements of the Contract Documents and/or the requirements of any code or law the Contractor is solely responsible for the cost of bringing such deficiencies into compliance with the terms of the Contract Documents and/or any code or law. d. Should the Architect, if an architect is retained for the project involving the Work, or Owner reject any portion of the Work for failing to comply with the Contract Documents Contractor shall immediately, at Contractor's expense, correct the Work. Any such rejection may be made before or after substantial completion. If applicable, any additional expense borne by the Architect under this section shall be paid at Contractor's expense. e. The Contractor shall not assign any portion of this Agreement nor subcontract the Work in its entirety without the prior written consent of the Owner. f. By executing this Agreement Contractor affirms that Contractor and any subcontractors of Contractor are and shall remain in compliance with Article 2 of Chapter 64 of the North Carolina General Statutes. g. By executing this Agreement Contractor certifies that Contractor has not been identified, and has not utilized the services of any agent or subcontractor identified, on the list created by the State Treasurer pursuant to G.S. 147 - 86.58. Revised 10/17 6 DocuSign Envelope ID: AOD5DO06- 1BO4- 4F7B- 96D7- OF7A4E374317 h. By executing this Agreement Contractor certifies that Contractor has not been identified, and has not utilized the services of any agent or subcontractor identified, on the list created by the State Treasurer pursuant to G. S. 147 - 86.81. i. Contractor shall at all times remain in compliance with all applicable local, state, and federal laws, rules, and regulations including but not limited to all state and federal non- discrimination laws, policies, rules, and regulations and the Orange County Non - Discrimination Policy and Orange County Living Wage Policy (each policy is incorporated herein by reference and may be viewed at http: / /www.oran eg countync. o�partments /purchasing division/contracts.php). Any violation of the Orange County Non - Discrimination Policy is a breach of this Agreement and County may immediately terminate this Agreement without further obligation on the part of the County. This paragraph is not intended to limit and does not limit the definition of breach to discrimination. j. This Agreement together with any amendments or modifications may be executed electronically. All electronic signatures affixed hereto evidence the consent of the Parties to utilize electronic signatures and intent of the Parties to comply with Article 11A and Article 40 of North Carolina General Statute Chapter 66. 12. CONSEQUENTIAL AND LIQUIDATED DAMAGES a. Owner and Contractor mutually waive any claim against each other for consequential damages. Consequential Damages include: i. Damages incurred by Owner for loss of use, income, financing, or business. ii. Damages incurred by Contractor for office expenses, including personnel, loss of financing, profit, income, business, damage to reputation, or any other non - direct damages. b. Liquidated damages shall be in accord with the Contract Documents. 13. TERMINATION OR SUSPENSION a. The Owner may, without cause, order the Contractor to terminate, suspend, delay or interrupt the Work in whole or in part for such period of time as the Owner may determine. i. If Owner issues a written order to delay, suspend, or interrupt the Work, and such order is not due to or as a result of any fault on the part of the Contractor or any subcontractor, the Contractor may recover a per diem amount of five hundred dollars ($500.00) per day with a not -to- exceed limit of ten thousand dollars ($10,000.00). ii. In the event of termination by the Owner under this Agreement, the Contractor shall be entitled to receive its reasonable and documented direct costs prior to termination, including the cost of materials purchased for the Work which purchases cannot be canceled or which material cannot reasonably be used by the Contractor on other work, and the cost of closing down the work in a safe and efficient manner. Revised 10/17 7 DocuSign Envelope ID: AOD5D006- 1B04- 4F7B- 96D7- OF7A4E374317 iii. If Owner elects to suspend or terminate the contract pursuant to subparagraphs 13.a.i. or 13 a.ii. the sole remedy available to the Contractor are those listed in the subparagraphs and Contractor is not entitled to any right to further claims for any amount owed or disputed or for payment of damages alleged to have been sustained as a result of Owner's order to delay, suspend, or interrupt the Work. b. The Owner may, with cause, order the Contractor to suspend, delay or interrupt the Work in whole or in part for such period of time as the cause remains. i. If Owner issues a written order to delay, suspend, or interrupt the Work, and such order is due to or as a result of any fault on the part of the Contractor or any subcontractor, the Owner may reduce payment at a per diem amount of five hundred dollars ($500.00) per day. c. Contractor may terminate the Contract if, at the Owner's written direction, the Work is stopped for twenty one (21) consecutive days through no act or fault of the Contractor, their agents or employees, or a subcontractor or their agents or employees or any other person performing work pursuant to the Contract Documents. Contractor may terminate the Contract if a Court or other Public authority having jurisdiction enters a lawful order that requires all work to be stopped and such stoppage lasts for twenty one (21) consecutive days. 14. ENTIRE AGREEMENT All of the documents listed, referenced or described in this Agreement, the written Notice -to- Proceed, together with Modifications made or issued in accordance herewith are the Contract Documents, and the work, labor, materials and completed construction required by the Contract Documents and all parts thereof is the Work. The Contract Documents constitute the entire agreement between Owner and Contractor. This Agreement may be amended only by written instrument signed by both parties. Modifications may be evidenced by facsimile signatures. If any provision of the Agreement shall be declared invalid or unenforceable, the remainder of the Agreement shall continue in full force and effect. [SIGNATURE PAGE TO FOLLOW] Revised 10/17 8 DocuSign Envelope ID: AOD5D006- 1B04- 4F7B- 96D7- OF7A4E374317 IN WITNESS WHEREOF, the Parties hereto have executed this Agreement as of the day and date first above written wholly or in a number of counterparts each of which shall, without proof or accounting for other counterparts, be deemed an original contract. ORANGE COUNTY �f�auw�i� _�f aw.wty� Signature County Manager CONTRACTOR 8/7/2018 C{LU4 �.dWntUU Signature Steve Bartholomew Printed Name and Title Revised 10/17 9 7/31/2018 Branch Manager DocuSign Envelope ID: AOD5DO06- 1BO4- 4F7B- 96D7- OF7A4E374317 PROPOSAL HOFFMAN • HOFFMAN, INC. 2741 NOBLIN RD, SUITE 100 RALEIGH, NC 27604 PHONE (919)- 781 -8011 FAX (919)- 787 -6019 April 24, 2018 To: Angel Barnes Orange County Asset Management Services 131 West Margaret Lane Hillsborough, NC 27278 Project: Orange County Board of Elections Engineer: RN &M Addendum: None To whom it may concern: For your consideration, we are pleased to quote as follows on equipment for the above project, all subject to approval of the engineer, architect, and /or owner. Although we have exercised due care in taking off the materials, our count is not guaranteed and should be verified by you. Prices can be adjusted accordingly. Hoffman & Hoffman, Inc. extends to the Buyer the warranties of the respective manufacturers of the products sold. HOFFMAN & HOFFMAN, INC. ITSELF MAKES NO WARRANTIES, EXPRESSED OR IMPLIED, AS TO ANY MATTER WHATSOEVER, INCLUDING, WITHOUT LIMITATION, THE CONDITION OF ANY GOODS SOLD, THEIR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. All purchase orders are subject to acceptance by the company at its home office. Please refer to the following pages for quantities, prices, manufacturer and product description. Prices quoted below are FOB factory with freight prepaid and allowed, except as noted, and do not include sales tax. Terms are net 30 days. Prices are firm if accepted within 30 days and released for fabrication and shipment within 60 days thereafter. Orders released after 60 days from date of customer's purchase order may be subject to escalation. Where Hoffman & Hoffman is the seller, all sales are subject to Hoffman & Hoffman's standard Terms and Conditions. These Terms and Conditions may be found on the last page of our Proposal forms or our Form TC 501. Otherwise, all sales are subject to the manufacturer's terms and conditions. If you do not have a copy of our Terms and Conditions, please request one. Thank you for your consideration of our equipment for this project. Yours sincerely, HOFFMAN & HOFFMAN, INC. Steve Bartholomew Raleigh Office 1 Hoffman & Hoffman, Inc. • 2741 Noblin Rd, Suite 100 Raleigh, NC 27604 • 919 - 781 -8011 DocuSign Envelope ID: AOD5DO06- 1BO4- 4F7B- 96D7- OF7A4E374317 Due to significant increases in steel and aluminum, all prices quoted are good for 30 days from date of proposal and must be released for production 60 days thereafter. Orders released after b0 days from date of customer's purchase order may be subject to escalation. Item A: Variable Volume Refrigerant Heat Recovery Systems by Daikin Please note our priingis nased on drawings dated 04/20/2018 provided by RN &M. We have not reviewed any specifications. Variable Refrigerant Heat Recovery Systems including: • (1) Mark OU -1 Model REYQ Heat Recovery System with 208/230 -3 -60 power requirement System consist of one (1) Model REYQ192TATU 16 Ton DualModule with a common header • (23) Model FXZQ 4- way Cassette Type Indoor Fan Coils with built in condensate pumps, fresh air intake connection • (2) Model FXMQ ceiling mounted ducted indoor units with filter with built in condensate pumps • (24) Model BRC1E73 Wall thermostats /controllers • (2) Model BS l OQ54TVJ 10 -Port Branch Selector Boxes • (1) Model BS8Q54TVJ 4 -Port Branch Selector Box • (1) Model BHFP26P100U Condensing Unit Joining Manifold • (2) Model BHRP25M72TU9 Refnet Refrigerant " Y" fitting • On Site Installation Assistance by Hoffman & Hoffman VRV Engineer • Post- construction set -up of system • Factory Authorized Start Up I -Touch Manager Control System with BACnet communications. • (1) Mark OU -2 Model RXYQ Heat Pump OA processing unit System with 208/230 -3 -60 power requirement, with (1) Model FXMQ ceiling mounted ducted indoor units with filter, with built in condensate pumps 52- Refrigerant isolation ball valves to be field installed by others in refrierant lines to fan coils. TOTAL FREIGHT ALLOWED PRICE ............. ............................... $ 65,772.00 Z Hoffman & Hoffman, Inc. • 2741 Noblin Rd, Suite 100 Raleigh, NC 27604 • 919 - 781 -8011 DocuSign Envelope ID: AOD5DO06- 1BO4- 4F7B- 96D7- OF7A4E374317 Remarks 1) As of today all items in stock in Houston, TX Lead time is 5 -7 Days 2) 10 — Year Factory Warrenty on parts- NO Labor 10 —Year Factory Warrany on Compressor- NO Labor No additional extended warranties available 3) Daikin requireds the installing Mechanical to be trained and certified for installation of their VRV Product. If you are not already certified you will be required to attend a (3) Day Installation training Class. The cost of this Class is $ 428.00 per person. Classes ares held at our Training Center located at our Greenboro NC facility. We will provide a light breakfast and lunch. We do not include dinner, travel or hotel cost. 4) Daikin Branch Selector Boxes do not require condensate drains 5) We do not include any R410A refrigerant except for holding charge in Condensing units. 6) We do not include any Control Wiring or installation of controls The control wiring is simple see attached piping and wiring Drawings.The control wire type is 18/2 stranded and NON shielded type. We do not include any interlock, control or power wiring Notes: • We do NOT include refrigerant lines, piping, condensate piping, T'stat boxes, electrical power wiring, roof curbs, disconnect switches or condensing unit mounting pads. • Daikin requires that the installing contractor to be "trained and certified" in the installation and commissioning of Daikin VRV system. The VRV system has stringent layout and piping installation requirements and requires comprehensive leak testing and evacuation prior to commissioning. The Daikin training is "critical" to proper system installation and operation. Daikin has regularly scheduled classes at the H&H Training Center in Greensboro, NC. It is strongly suggested that the Mechanical Contracor send at least one of their key field installers to the Daikin Installation & Commissioning training class prior to installation. Hoffman & Hoffman will provide the cost of this training for $ 428.00 per per person.. However, contractor is resposible for all travel expenses. Training classes are held in Greensboro, NC. • The Daikin VRV System includes a one (10) year parts and compressor warranty from the date of installation. Warranty is for defects in material and workmanship performed by the Daikin trained local service contractor (i. e Installing Contractor). The Installing Contractor should include a provision for the labor warranty with their bid. Parks will be repaired or replaced at the descretion of Daikin in accordance to the Daikin Terms & Conditions. Daikin also has regularly scheduled "advanced" east coast training classes available at the H &H Training Center in Greensboro, NC. • We do NOT include extended compressor labor warranties. We include parts only. • We DO include one (2) days of check - test - start -up assistance for the Daikin equipment for the installing contractor with integral Owner Training during the start -up period. • We do NOT include auxillary drain pans or float switches for the auxillary drain pans. • We do NOT include conduit for all exposed and exterior areas or wire or installation of control wiring. • We do NOT include any Commissioning Services. 3 Hoffman & Hoffman, Inc, • 2741 Noblin Rd, Suite 100 Raleigh, NC 27604 • 919 - 781 -8011 DocuSign Envelope ID: AOD5DO06- 1BO4- 4F7B- 96D7- OF7A4E374317 TERMS AND CONDITIONS "H &H" shall mean Hoffman & Hoffman, Inc. 1. Controlling Terms & Conditions: This Agreement, upon Buyer's acceptance, is limited to the terms and conditions stated herein, despite any additional or conflicting terms and conditions contained in any purchase order, any other document presented by Buyer, or any contract document between Buyer and any third -party (i.e. an owner, other contractor, etc.), all of which additional or conflicting terms are hereby rejected by H &H. No waiver of, or modification to, these Terms and Conditions shall be valid unless made in writing and signed by an authorized representative of H &H. The terms of any written proposal / quote made by H &H ( "proposal ") and these Terms and Conditions shall constitute the entire agreement of the parties. 2. Acceptance: Any H &H proposal expires if not accepted by Buyer within thirty (30) days from the date of the proposal. Prices are firm after acceptance provided the Buyer releases the order for production by written notice to H &H within sixty (60) days of placing the order. Otherwise, prices are subject to escalation. Typographical and clerical errors in quotations, orders and acknowledgments are subject to correction. Buyer is deemed to have accepted any H &H proposal to purchase goods or services, including these Terms and Conditions, when Buyer either (a) receives and retains an acknowledgement from H &H without written objection within ten (10) days, (b) accepts delivery of all or any part of the goods ordered, (c) provides to H &H delivery dates, shipping instructions, or other instructions evidencing acceptance, or (d) otherwise executes or assents to any proposal or these Terms and Conditions. If Buyer accepts any proposal, without the addition of any other terms and conditions or any other Buyer modification, Buyer's order shall be deemed acceptance of the proposal subject solely to H &H's terms and conditions. If Buyer's order is expressly conditioned upon H &H's acceptance or assent to terms and /or conditions other than those stated herein, return or acknowledgment of such order by H &H with H &H's Terms and Conditions attached or referenced serves as H &H's notice of objection to, and rejection of, Buyer's terms and as H &H's counter -offer to provide goods or services in accordance with the H &H proposal and H &H's Terms and Conditions. If thereafter Buyer does not reject or object in writing to H &H within ten (10) days by written notice to Legal @hoffman- hoffman.com, H &H's counter -offer will be deemed accepted by Buyer. In any event, Buyer's acceptance of all or any part of any goods ordered will constitute Buyer's acceptance of H &H's proposal subject to H &H's Terms and Conditions. 3. Terms of Payment / Taxes: Payment is due net thirty (30) days from date of H &H's invoice to Buyer. Interest at the rate of 1 12% per month (or the highest interest rate allowed by applicable law, if lower) may be charged after the 30 -day period until payment is received. Buyer shall pay all costs of collection incurred by H &H including, but not limited to, reasonable attorneys' fees, collection fees, and court costs. H &H may suspend all further services and transactions (regardless of their status) without liability if Buyer's account is more than thirty (30) days past due or if Buyer's credit, in the sole judgment of H &H, is impaired at any time. Partial invoices may be submitted for any portion of completed work and /or delivered materials. While risk of loss passes to Buyer, Seller will have a purchase -money security interest in all goods (including any accessories and substitutions) purchased under this Agreement to secure payment in full of all amounts due H &H, and the underlying proposal, together with these Terms and Conditions, form a security agreement (as defined by the UCC.) Buyer shall keep all goods purchased under this Agreement free of all taxes and encumbrances, shall not remove said goods from their original installation point and shall not assign or transfer any interest in said goods until all payments due H &H have been made. The purchase -money security interest granted herein attaches upon H &H's acceptance or acknowledgment of this Agreement and Buyer's receipt of said goods, but prior to installation. Buyer will have no rights to set off against any amounts which become payable to H &H under this Agreement or otherwise. Notwithstanding any Buyer form or document to the contrary, H &H shall not release any rights to make a lien and /or bond claim, or other claim for damages, in connection with goods purchased or services provided until H &H has obtained payment in full for such goods or services and any damages. Furthermore, Buyer is responsible to pay in full for the goods or services provided by H &H regardless of whether such goods or services are funded for Buyer pursuant to any extraneous contract and /or by an applicable project owner or contractor. Unless otherwise agreed by H &H in writing, Buyer shall pay to H &H, in addition to the contract price, all sales, use, excise, privilege or other taxes imposed by any local, state or federal taxing authority payable in connection with the goods or services furnished. 4. Shipments / Claims: All shipments of goods are at Buyer's risk, f.o.b. factory, or if shipped from another location, f.o.b. point of shipment, with charges either allowed, added to invoice, or collected as noted. Any claims for damage or shortage or loss in transit must be filed by Buyer against the applicable carrier. If requested, H &H will reasonably assist the Buyer when making its claim for damages and /or losses while in transit. Claims against factory shortages will not be considered unless made within sixty (60) days after Buyer's receipt of the goods. 5. Approval: H &H shall not be liable in any way should any third party (such as a project architect, engineer, owner, etc.) fail to accept or approve equipment ordered by Buyer. H &H cannot guarantee to meet or equal specifications written around another make of equipment different than that purchased by Buyer. 6. Warranties and Liability: Upon condition that H &H receives payment in full for all amounts owed, H &H extends to Buyer the manufacturer's warranty (a copy of which is available upon request), and manufacturer's warranty is in lieu of any warranties contained in any applicable project contract, conditions, plans, or specifications. H &H ITSELF MAKES NO OTHER WARRANTIES, EXPRESS OR IMPLIED, AS TO ANY MATTER WHATSOEVER, INCLUDING, WITHOUT LIMITATION, THE CONDITION OF THE EQUIPMENT, ITS MERCHANTABILITY, IMPLIED WARRANTIES OF DESIGN OR FITNESS FOR A PARTICULAR PURPOSE. H &H SHALL HAVE NO LIABILITY FOR ANY DIRECT DAMAGES BY REASON OF FAILURE OF THE EQUIPMENT TO OPERATE OR FAULTY OPERATION OF THE EQUIPMENT, AND UNDER NO CIRCUMSTANCES SHALL H &H BE LIABLE FOR ANY INDIRECT, INCIDENTAL, CONSEQUENTIAL, SPECIAL, PUNITIVE, EXEMPLARY OR LIQUIDATED DAMAGES OR LOSSES, INCLUDING BUT NOT LIMITED TO, LOSS OF USE, INCOME, PROFIT OR PRODUCTION, LOST DATA, SPOILAGE, DELAY, OR INCREASED COST OF OPERATION. SAID EXCLUSIONS APPLY EVEN IF H &H HAS BEEN ADVISED OF SUCH POSSIBLE DAMAGES OR IF SUCH POSSIBLE DAMAGES WERE REASONABLY FORESEEABLE. Buyer acknowledges that H &H is not responsible for the design of goods or services purchased and did not participate in any project design in connection with such goods or services. 7. Limitation of Remedy: H &H shall have no liability for any damage caused by negligence, accident, misuse, improper storage, improper installation, improper service, maintenance or operation of equipment by Buyer or any third party. As determined at H &H's option and in its sole discretion, H &H's liability (whether under theories of warranty, negligence, strict liability or contract) is limited solely to (a) repair or replacement of purchased equipment or its parts by H &H or its duly authorized representative or (b) refund of the purchase price, and the foregoing shall be the sole and exclusive remedy against H &H. In no event shall H &H's liability exceed the purchase price paid by Buyer under this Agreement, and Buyer waives all other remedies at law or in equity. Furthermore, Buyer waives any claim with respect to goods or services purchased under this Agreement, unless Buyer notifies H &H in writing within ten (10) days of the date Buyer discovered, or by reasonable inspection should have discovered, the basis for such claim. 8. Hazards: H &H is not responsible for the identification, detection, abatement, encapsulation or removal of hazardous substances, such as (without limitation) asbestos, products or materials containing asbestos, mold, fungi, mildew, or bacteria. At all times now and in the future, H &H takes no responsibility for and makes no representations or warranties concerning any existing or future hazardous substance or condition (i.e. mold) or the remedy or prevention thereof. Furthermore, Buyer has a duty to alert H &H of any known or likely potential hazards at any project site where H &H's representatives and affiliates may be present in connection with this Agreement. 9. Indemnification: To the fullest extent permitted by law and except as provided in this Paragraph, Buyer shall indemnify, hold harmless and defend H &H and its officers, employees and agents from and against all claims, demands, liabilities, suits, judgments, awards, or expenses of any kind (including reasonable attorneys' fees and costs incurred defending such claims or demands, regardless of whether they result in legal action or are prosecuted to final judgment or award), which result from any alleged damage, loss of and /or injury to property or person, arising from Buyer's purchase or use of goods or services provided by H &H. Buyer shall indemnify H &H against, without limitation, liability arising from any acts or omissions whether deemed negligent, accidental or intentional, which is caused, in part, by the active or passive negligence or other fault of H &H. To the fullest extent permitted by law, the obligations of defense and indemnification set forth herein shall be binding upon Buyer no matter what the nature of the claim asserted may be (whether it be for negligence, warranty, strict liability, or otherwise) and shall be binding even if H &H is alleged or proven to have acted negligently; provided, however, that Buyer shall have no obligation to provide indemnification to H &H if the claim asserted arises in negligence and is finally adjudicated to have arisen solely from the negligence of H &H. Buyer shall also indemnify and hold harmless H &H from all liability for taxes owing in connection with Buyer's purchase of goods or services. The obligations and rights to indemnity herein shall not negate, abridge or reduce other such rights or obligations under law. 10. Claims Resolution / Governing Law: All claims and disputes between Buyer and H &H arising out of or relating to performance of any agreement or breach thereof shall be decided by binding arbitration in accordance with the Construction Industry Arbitration rules of the American Arbitration Association (AAA). Notice of Demand for Arbitration must be filed in the regional office of the AAA in Charlotte, North Carolina, and the filing party must serve such Notice upon the other party in accordance with AAA rules. The procedural and substantive law of the State of North Carolina shall apply in and to all arbitration proceedings, and Greensboro, North Carolina, is designated as the venue for such proceedings. Both parties will have the right to conduct discovery in accordance with the Federal Rules of Civil Procedure within reasonable time limitations imposed by the AAA or the applicable arbitrators. Any award arising from such proceedings shall be final and binding upon the parties and enforceable in accordance with the Federal Arbitration Act. This Agreement shall be governed by and construed in accordance with the laws of the State of North Carolina. 11. Delays / Penalties / Force Majeure: Delivery dates are approximate and not guaranteed. In no event and under no circumstances whatsoever, will H &H be liable for any damages or expenses caused by any failure or delay in making delivery of goods or in performing services hereunder. No penalty clause or liquidated damages of any kind (for delays or otherwise) apply to H &H unless pre- approved in writing by an H &H officer. Furthermore, in no event and under no circumstances whatsoever, will H &H be liable under this Agreement for any event of force majeure, an event or cause beyond the reasonable control of H &H. 4 Hoffman & Hoffman, Inc. • 2741 Noblin Rd, Suite 100 Raleigh, NC 27604 • 919 - 781 -8011 DocuSign Envelope ID: AOD5DO06- 1BO4- 4F7B- 96D7- OF7A4E374317 12. Cancellations / Returns: If an order is canceled through no fault of H &H, the Buyer shall reimburse H &H for all expenses, costs, damages and losses (including lost profits) incurred by H &H in connection with the order and its cancellation. Goods may not be returned except by written permission of a representative of H &H, and when so returned, shall be subject to handling and transportation charges. 13. Equal Employment Opportunity / Affirmative Action Clause: H &H and Buyer shall abide by the requirements of 41 CFR 60- 1.4(a), 60- 300.5(a) and 60- 741.5(a). These regulations prohibit discrimination against qualified individuals based on their status as protected veterans or individuals with disabilities, and prohibit discrimination against all individuals based on their race, color, religion, sex, sexual orientation, gender identity or national origin. Moreover, these regulations require that covered prime contractors and subcontractors take affirmative action to employ and advance in employment individuals without regard to race, color, religion, sex, sexual orientation, gender identity, national origin, disability or veteran status. 14. Government Contracts / Disadvantaged Business Entities: If Buyer's purchase of goods or services is in any way connected to any federal, state, or local government project, which implicates or utilizes any Small, Minority or Disadvantaged Business incentives or qualifications (or other similar laws or regulations), Buyer represents and certifies to H &H that Buyer is performing a commercially useful function on such project. Carolina. 11. Delays / Penalties / Force Maieure: Delivery dates are approximate and not guaranteed. In no event and under no circumstances whatsoever, will H &H be liable for any damages or expenses caused by any failure or delay in making delivery of goods or in performing services hereunder. No penalty clause or liquidated damages of any kind (for delays or otherwise) apply to H &H unless pre- approved in writing by an H &H officer. Furthermore, in no event and under no circumstances whatsoever, will H &H be liable under this Agreement for any event of force majeure, an event or cause beyond the reasonable control of H &H. 12. Cancellations / Returns: If an order is canceled through no fault of H &H, the Buyer shall reimburse H &H for all expenses, Prices, damages and losses (including lost profits) incurred by H &H in connection with the order and its cancellation. Goods may not be returned except by written permission of a representative of H &H, and when so returned, shall be subject to handling and transportation charges. 13. Epu d Employment Opportunity / Affirmative Action Clause: H &H and Buyer shall abide by the requirements of 41 CFR 60- 1.4(a), 60- 300.5(a) and 60- 741.5(a). These regulations prohibit discrimination against qualified individuals based on their status as protected veterans or individuals with disabilities, and prohibit discrimination against all individuals based on their race, color, religion, sex, sexual orientation, gender identity or national origin. Moreover, these regulations require that covered prime contractors and subcontractors take affirmative action to employ and advance in employment individuals without regard to race, color, religion, sex, sexual orientation, gender identity, national origin, disability or veteran status. 14. Government Contracts/ Disadvantaged Business Entities: If Buyer's purchase of goods or services is in anyway connected to any federal, state, or local government project, which implicates or utilizes any Small, Minority or Disadvantaged Business incentives or qualifications (or other similar laws or regulations), Buyer represents and certifies to H &H that Buyer is performing a commercially useful function on such project. 5 Hoffman & Hoffman, Inc. • 2741 Noblin Rd, Suite 100 Raleigh, NC 27604 • 919 - 781 -8011 DocuSign Envelope ID: AOD5DO06- 1BO4- 4F7B- 96D7- OF7A4E374317 /1 1 1 2 V 3 4 LEGEND A CEILING SUPPLY DIFFUSER, TYPE AND CFM INDICATED 275 F CEILING RETURN GRILLE, TYPE AND CFM INDICATED 450 E CEILING EXHAUST GRILLE, TYPE AND CFM INDICATED 95 TYPE CEILING RETURN GRILLE, TYPE AND CFM INDICATED G" IU -5 CONCEALED DUCTED INDOOR UNIT IU 1 I CEILING CASSETTE INDOOR UNIT C CONDENSATE DRAIN PIPING R REFRIGERANT PIPING 24X12 RECTANGULAR DUCT, WIDTH x DEPTH ROUND OR SPIRAL DUCT, DIAMETER DUCT BALANCE DAMPER DUCT TRANSITION DUCT TAKEOFF AT 45 DEGREES(TYPICAL) DUCT SQUARE ELBOW WITH TURNING VANES SD DUCT SMOKE DETECTOR (FURNISHED BY E.C. AND INSTALLED BY M.C.) UC UNDERCUT DOOR OT WALL MOUNTED THERMOSTAT / CONTROLLER FLEXIBL CONNECTION GENERAL MECHANICAL DUCTWORK NOTES CFM 1. THE DRAWINGS SHOW THE LOCATION AND ARRANGEMENT OF PIPING, DUCTS, AND EQUIPMENT, TOGETHER 50 WITH DETAILS OF CONNECTIONS OF CERTAIN PRINCIPAL ITEMS. THE LAYOUT SHOWN SHALL BE FOLLOWED A AS CLOSELY AS CIRCUMSTANCES WILL PERMIT, BUT THIS CONTRACTOR SHALL REFER TO ARCHITECTURAL, 50 0 o STRUCTURAL, PLUMBING, AND ELECTRICAL DRAWINGS AND SHALL COOPERATE FULLY WITH OTHER 50 CONTRACTORS AND TRADES WHILE INSTALLING DUCTS, PIPING, AND OTHER EQUIPMENT BECAUSE OF CLOSE 50 =II I SPACE LIMITS. IN CASE OF CONFLICT, NOTIFY DESIGNER BEFORE PROCEEDING WITH INSTALLATION. REFER 40 TO ARCHITECTURAL DRAWINGS FOR EXACT BUILDING DIMENSIONS AND LOCATIONS OF PARTITION WALLS, 40 DOORS, CHASES, CASEWORK, ETC. DO NOT SCALE MECHANICAL DRAWINGS FOR SUCH DIMENSIONS. 35 IU -1 -09 20 Cn m 2. THIS CONTRACTOR SHALL PROVIDE AND INSTALL ALL OFFSETS, FITTINGS, AND ACCESSORIES THAT MAY BE 40 v REQUIRED FOR A COMPLETE AND PROPER INSTALLATION, OR RECOMMENDED BY THE EQUIPMENT WHETHER OR NOT THEY ARE SPECIFICALLY SHOWN OR SPECIFIED. 20 IU -1 -12 IMANUFACTURER, IU -1 -13 c� 3. DUCTWORK SIZES INDICATED ON DRAWINGS ARE FREE INSIDE DIMENSIONS. IU -1 -14 4. MAXIMUM LENGTH OF FLEXIBLE DUCT IS SIX FEET (6). IU -1 -15 ra IU -1 -16 5. ALL VALVES, DAMPERS, CONTROLS, AND OTHER ITEMS REQUIRED FOR OPERATION OR MAINTENANCE ARE TO IU -1 -17 BE ACCESSIBLE. I IU -1 -18 20 B 6. ALL SLEEVES, OUTLET BOXES, AND OTHER ROUGH -INS FOR SUCH ITEMS AS FIRE DAMPERS, PIPE IU -1 -20 PENETRATIONS, LOUVERS, AND CONTROL ITEMS SHALL BE INSTALLED AS THE BUILDING CONSTRUCTION IU -1 -21 PROGRESSES. ALL FLOOR /ROOF /PLATFORM PENETRATIONS TO BE CAST IN PLACE SLEEVES. IU -1 -22 7. PROVIDE AND INSTALL VOLUME CONTROL DAMPERS AT ALL SUPPLY MAIN AND BRANCH DUCT TAKE -OFFS. IU -1 -23 8. PROVIDE AND INSTALL DUCT ACCESS DOORS AT ALL SMOKE DAMPERS, FIRE DAMPERS, AND DUCT SMOKE IU -1 -24 DETECTORS. REFER TO MECHANICAL AND ELECTRICAL DRAWINGS FOR DUCT SMOKE DETECTOR LOCATIONS. IU -1 -25 N IU -1 -26 9. THIS CONTRACTOR SHALL TAKE FIELD MEASUREMENTS BEFORE FABRICATING ANY DUCTS TO ENSURE THAT IU -1 -27 10 DUCT SIZES SHOWN WILL FIT INTO AVAILABLE SPACE. IN CASE OF CONFLICT, NOTIFY THE DESIGNER BEFORE PROCEEDING. _ 0 i 10. ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. =II 11. COORDINATE LOCATIONS OF ALL FLOOR DRAINS WITH PLUMBING CONTRACTOR, PRIOR TO SLABS BEING POURED. C N o 12. COORDINATE EXACT LOCATION FOR ALL CEILING DIFFUSERS /GRILLES WITH ARCHITECTURAL REFLECTED �? CEILING PLAN AND ELECTRICAL CONTRACTOR'S LIGHTING LAYOUT. �m 13. ALL EMS SENSORS AND OTHER FIELD DEVICES MOUNTED ON WALLS TO BE PROTECTED FROM DAMAGE AS REQUIRED - INSTALL LEXAN COVERS, WIRE GUARDS, OR SIMILAR AS REQUIRED. COORDINATE CONDITIONS IN �t THE FIELD. �N 14. THE MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING TO THE GENERAL CONTRACTOR Io THE QUANTITY, SIZE AND LOCATIONS OF ALL ACCESS DOORS IN WALLS, DRYWALL CEILINGS, ETC. FOR ACCESS TO VALVES, BALANCE DAMPERS OR OTHER EQUIPMENT AS REQUIRED. COORDINATE THIS WORK WITH THE REFLECTED CEILING PLANS. ALL VALVES OR OTHER DEVICES LOCATED ABOVE THE CEILING SHALL BE LOCATED IN ACCESSIBLE CEILINGS WHEREVER POSSIBLE. VERIFY LOCATION OF ALL VALVES IN INACCESSIBLE CEILINGS OR CHASES WITH THE ARCHITECT PRIOR TO INSTALLATION. 15. COORDINATE EXACT SIZE, LOCATION, APPURTENANCES, ETC. FOR ALL ROOF OPENINGS. _ 16. REFER TO MANUFACTURER'S DETAILS FOR PERMISSIBLE LOCATIONS AND METHODS FOR HANGING DUCTWORK FROM STRUCTURE. ALL DUCTWORK HANGERS TO BE WITHIN 6" OF PANEL POINTS OF JOISTS. DO D =� NOT WELD DUCT HANGERS /SUPPORTS TO STRUCTURE WITHOUT PRIOR APPROVAL FROM THE ENGINEER AND o GENERAL CONTRACTOR. 17. COORDINATE EXACT SIZES REQUIRED FOR ALL OPENING FOR DUCTWORK AND PIPING WITH SPACE to REQUIREMENTS AND EXISTING CONDITIONS PRIOR TO FRAMING FOR THE PENETRATIONS. N � 2 ■ GENERAL MECHANICAL PIPING NOTES 1. CONTRACTOR TO SLOPE ALL CONDENSATE DRAIN PIPING ABOVE CEILINGS, UNDER SLAB, AND BELOW GRADE -1/8" PER FOOT (MINIMUM). 2. IN MECHANICAL ROOMS AND ON MECHANICAL PLATFORMS, ROUTE ALL A/H UNIT CONDENSATE DRAIN PIPING TO CLOSEST FLOOR OR HUB DRAIN UNLESS SHOWN OTHERWISE. 3. REFER TO STRUCTURAL DRAWINGS AND DETAILS FOR PERMISSIBLE LOCATIONS AND METHODS FOR HANGING PIPING FROM STRUCTURE. ALL PIPE HANGERS TO BE WITHIN 6" OF PANEL POINTS OF JOISTS. DO NOT WELD E PIPE HANGERS /SUPPORTS TO STRUCTURE WITHOUT PRIOR APPROVAL FROM THE ENGINEER. REFRIGERANT PIPING / POWER AND CONTROL WIRING NOTES: 1. VRV SYSTEM PIPING AND ALL POWER / CONTROL WIRING AND CONDUIT NOT SHOWN ON THESE PLANS. EACH VRV HP MANUFACTURER HAS DIFFERENT PIPING REQUIREMENTS, CONTRACTOR TO COORDINATE WITH SPECIFIC EQUIPMENT MANUFACTURER / VENDOR IN REGARDS TO EXACT REFRIGERANT PIPING ROUTING, QUANTITY, AND SIZING, AS WELL AS ACCESSORIES (REFNET JOINTS, ELBOWS, HEADERS, BRANCH SELECTOR BOXES, EXPANSION LOOPS, ETC.) AS TO QUANTITIES AND LOCATIONS. EQUIPMENT MANUFACTURER / VENDOR TO FURNISH TO THE CONTRACTOR (PRIOR TO BIDDING) COMPLETE EQUIPMENT, REFRIGERANT PIPING, AND POWER / CONTROL WIRING AND CONDUIT LAYOUT DRAWINGS; COMPLETE SUBMITTALS OF ALL EQUIPMENT, ACCESSORIES, DEVICES, ETC.; COMPLETE LIST OF ALL REQUIRED MATERIALS (TAKE -OFFS) SUCH AS REFRIGERANT PIPING (AMOUNT AND SIZE), REFNET JOINTS, ELBOWS, HEADERS, BRANCH SELECTOR BOXES, ETC.. INFORMATION TO BE SUFFICIENT FOR CONTRACTOR TO PERFORM DETAILED TAKE -OFFS FOR BIDDING AND INSTALLATION. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL COSTS ASSOCIATED WITH PROVIDING A COMPLETE AND FUNCTIONAL SYSTEM. DRAWINGS TO SHOW LOCATIONS, PROPOSED ROUTING, F SIZES, FITTINGS, ACCESSORIES, ETC.. DRAWING PACKAGE TO BE FURNISHED AS PART OF SUBMITTAL PACKAGE (BY SUCCESSFUL VENDOR). 2. THIS CONTRACTOR SHALL GENERALLY BE REQUIRED TO FURNISH AND INSTALL POWER WIRING / CONDUIT FOR INDOOR UNITS AND BRANCH SELECTOR BOXES (WHERE APPLICABLE). E.C. TO FURNISH A JUNCTION BOX WITH POWER WIRING FROM PANEL IN THE VICINITY OF EACH INDOOR FAN COIL UNIT. E.C. TO FURNISH A 2 -POLE, FUSED DISCONNECT SWITCH (FUSED PER MFG'S RECOMMENDATIONS) AT EACH INDOOR FAN COIL UNIT AND BRANCH SELECTOR BOX. THIS CONTRACTOR TO FURNISH AND INSTALL POWER WIRING AND CONDUIT (SIZED PER NEC, ELECTRICAL DRAWINGS, AND MFG RECOMMENDATIONS) FROM EACH JUNCTION BOX TO EACH FAN COIL UNIT (AND, WHERE APPLICABLE, THE ASSOCIATED BRANCH SELECTOR BOX). M.C. CABLE MAY BE UTILIZED WHERE ALLOWED PER THE ELECTRICAL SPECIFICATIONS. ROUTE THROUGH DISCONNECT TO EQUIPMENT - BY THIS CONTRACTOR. SEE ELECTRICAL DRAWINGS AND MECHANICAL DETAILS. 3. THIS CONTRACTOR TO FURNISH AND INSTALL ALL CONTROL CONDUIT, WIRING, CABLES (LOW VOLTAGE AND OTHERWISE). 4. E.C. TO FURNISH AND INSTALL FUSED DISCONNECT SWITCHES FOR ALL INDOOR FAN COIL UNITS, BRANCH G SELECTOR BOXES, AND OUTDOOR UNITS. THIS CONTRACTOR TO SUPPLY FUSES (SIZED PER MFG'S RECOMMENDATIONS). 5. THIS CONTRACTOR TO FURNISH AND INSTALL ALL REFRIGERANT PIPING, ALONG WITH ASSOCIATED FITTINGS, DEVICES, CONTROLS, ETC. FOR A COMPLETE SYSTEM PER THE VRV MANUFACTURER'S SUGGESTIONS. 6. BASIS OF DESIGN IS DAIKIN. DEMOLITION NOTES 1. ALL DEMOLITION WORK OF EXISTING HVAC SYSTEM TO BE BY OWNER, WITH THE EXCEPTION OF THE EXISTING CONDENSING UNITS ON THE ROOF. THIS CONTRACTOR TO BE RESPONSIBLE FOR REMOVING H EXISTING CONDENSING UNITS (WHILE CRANE IS AVAILABLE TO SET NEW OUTDOOR UNITS). 2. M.C. TO REMOVE EXISTING WINDOW THAT WILL BE REPLACED WITH AN O/A INTAKE LOUVER. 3 4 LEGEND A CEILING SUPPLY DIFFUSER, TYPE AND CFM INDICATED 275 F CEILING RETURN GRILLE, TYPE AND CFM INDICATED 450 E CEILING EXHAUST GRILLE, TYPE AND CFM INDICATED 95 TYPE CEILING RETURN GRILLE, TYPE AND CFM INDICATED G" IU -5 CONCEALED DUCTED INDOOR UNIT IU 1 I CEILING CASSETTE INDOOR UNIT C CONDENSATE DRAIN PIPING R REFRIGERANT PIPING 24X12 RECTANGULAR DUCT, WIDTH x DEPTH ROUND OR SPIRAL DUCT, DIAMETER DUCT BALANCE DAMPER DUCT TRANSITION DUCT TAKEOFF AT 45 DEGREES(TYPICAL) DUCT SQUARE ELBOW WITH TURNING VANES SD DUCT SMOKE DETECTOR (FURNISHED BY E.C. AND INSTALLED BY M.C.) UC UNDERCUT DOOR OT WALL MOUNTED THERMOSTAT / CONTROLLER FLEXIBL CONNECTION RETURN 1 01111! 5 FLEXIBLE CONNECTION 3/4" COND. DRAIN AND AUXILIARY DRAIN PAN WITH 3/4" AUX. PAN DRAIN TO FLOAT SWITCH UNDER A/H OR P CONTR'S DRAIN OR PUMP. UNIT BY THIS CONTRACTOR OUTSIDE AIR SCHEDULE A/H UNIT MOUNTED IN HORIZONTAL POSITION CFM IU -1 -01 50 IU -1 -02 50 IU -1 -03 50 5 FLEXIBLE CONNECTION 3/4" COND. DRAIN AND AUXILIARY DRAIN PAN WITH 3/4" AUX. PAN DRAIN TO FLOAT SWITCH UNDER A/H OR P CONTR'S DRAIN OR PUMP. UNIT BY THIS CONTRACTOR OUTSIDE AIR SCHEDULE UNIT CFM IU -1 -01 50 IU -1 -02 50 IU -1 -03 50 IU -1 -04 50 IU -1 -05 50 IU -1 -06 40 IU -1 -07 40 IU -1 -08 35 IU -1 -09 20 IU -1 -10 40 IU -1 -11 20 IU -1 -12 20 IU -1 -13 10 IU -1 -14 45 IU -1 -15 175 IU -1 -16 175 IU -1 -17 15 IU -1 -18 20 IU -1 -19 20 IU -1 -20 10 IU -1 -21 10 IU -1 -22 25 IU -1 -23 10 IU -1 -24 10 IU -1 -25 40 IU -1 -26 15 IU -1 -27 10 TYPICAL A/H UNIT DETAIL 1 1 2 1 3 1 4 NOT TO SCALE 5 0 7 E-1 MECHANICAL SUMMARY - MECHANICAL SYSTEMS, SERVICE SYSTEMS, AND EQUIPMENT THERMALZONE 4A WINTER DRY BULB 16 °F SUMMER DRY BULB 93 °F INTERIOR DESIGN CONDITIONS WINTER DRY BULB 70 °F SUMMER DRY BULB 75 °F RELATIVE HUMIDITY 50% BUILDING HEATING LOAD 179,000 BTUH BUILDING COOLING LOAD 20 TONS MECHANICAL SPACING CONDITIONING SYSTEM UNITARY DESCRIPTION OF UNIT HEATING EFFICIENCY REFER TO EQUIPMENT SCHEDULES FOR EFFICIENCIES COOLING EFFICIENCY SIZE CATEGORY OF UNIT BOILER TOTAL BOILER OUTPUT. IF OVERSIZED STATE REASON N/A CHILLER TOTAL CHILLER CAPACITY. IF OVERSIZED STATE REASON N / A LIST EQUIPMENT EFFICIENCIES I REFER TO EQUIPMENT SCHEDULES FOR EFFICIENCIES GRILLE & DIFFUSER SCHEDULE SYMBOL TYPE LOCATION MANUFACTURER SIZE CFM REMARKS MODEL A SUPPLY CEILING PRICE 10 "0 OFF -WHITE FINISH, SQUARE TO ROUND LAY -IN SCD 2424 400 TRANSITION AS REQUIRED B RETURN/ CEILING PRICE 6x6 100 OFF -WHITE FINISH EXHAUST LAY -IN PDDR 24x24 C RETURN/ CEILING PRICE 8x8 220 OFF -WHITE FINISH EXHAUST LAY -IN PDDR 24x24 RETURN/ CEILING PRICE 10x10 D EXHAUST LAY -IN PDDR 350 OFF-WHITE FINISH 24x24 RETURN/ CEILING PRICE 16x16 E EXHAUST LAY -IN PDDR 600 OFF-WHITE FINISH 2 4x24 NOTES: 1. ALL GRILLES / DIFFUSERS SERVING LOCKERS, KITCHEN, TOILETS AND JAN. CLOSETS TO HAVE ALUMINUM CONSTRUCTION. 2. ALL GRILLE DESIGNATIONS MAY NOT BE UTILIZED ON THIS PROJECT. 3. BASIS OF DESIGN - PRICE; EQUIVALENT PRODUCTS BY: CARNES, TITUS, AND KRUEGER. HOOD / LOUVER SCHEDULE SYMBOL TYPE LOCATION MANUFACTURER SIZE CFM REMARKS MODEL INTAKE WALL RUSKIN 48x72 1055 1, 2, 3, 4 LOUVER ELF -375DX REMARKS: 1. BIRD SCREEN 2. BAKED ENAMEL FINISH - COLOR BY OWNER. 3. COMPARABLE PRODUCTS BY ARROW, CESCO, AMERICAN WARMING & VENTILATING, EMPCO, & DOWCO 4. COORDINATE DIMENSIONS WITH EXISTING WINDOW DIMENSIONS PRIOR TO ORDERING. FAN SCHEDULE FAN # TYPE LOCATION CFM S.P. RPM HP VOLT -PH. MFG. & MODEL SONES ROOF OPG. REMARKS EF -1 EXHAUST ROOF 450 .5" 1620 1/10 120 -1 GREENHECK 7.1 10.5x10.5 1, 2, 3, 4, 5 #G- 075 -VG EF -2 EXHAUST ROOF 400 .5" 1620 1/10 120 -1 GREENHECK 1, 2, 3, 4, 5 #G- 075 -VG 0 NOTE: BASIS OF DESIGN - GREENHECK; EQUIVALENT PRODUCTS BY CARNES, COOK, & PENN REMARKS: 1. DISCONNECT SWITCH 2. BACKDRAFT DAMPER 3. PRE - FABRICATED ROOF CURB. COORDINATE WITH ROOF TYPE AND SLOPE. 4. ON PROGRAM CONTROL WITH LOCAL AHU ZONE TO RUN WHEN BLDG. IS OCCUPIED. 5. BIRD SCREEN 7 E-' A 0 C N C F G H WA AA R Kli =ENGINEERS Reece, Noland & McElrath, Inc. 94 Main Street Canton, North Carolina 28716 PHONE: 828 - 492 -0677 FAX: 828 - 492 -1054 MAIL @RNM - ENGINEERS. COM WWW.RNM- ENGINEERS.COM NC CERT. N0. C -0149 (C 2018 SEALS: m Z W J }} }}i]If7f1l o = ¢� CAR 0 U W `1� ` oneoav /f, ��JW ZNU O �.o7 cno OW SEAL _ - 0uiU-0 O w ?i u- ui m L i i --5 a Q N W f� , ° °�'ci;[n,4 K]. = V) U) z O F_ U Wz 0 W F_ LL Q 00. � Q _j Z W D 0 Z o m W 0 75 m F_ ::D J z W O c) U � W = V z U OW 0 REVISIONS /SU BM ISSIONS NO DATE ISSUED FOR 1 2 3 4 5 6 7 8 SHEET TITLE: MECHANICAL SUMMARY AND SCHEDULES ISSUED FOR: CONSTRUCTION DRAWN BY: DJM DRAWING NO. APPROVED BY: MRM PROJECT #: 2017108 0 .1 DATE: 05/07/2018 OF 8 SHEETS GRILLE & DIFFUSER SCHEDULE SYMBOL TYPE LOCATION MANUFACTURER SIZE CFM REMARKS MODEL A SUPPLY CEILING PRICE 10 "0 OFF -WHITE FINISH, SQUARE TO ROUND LAY -IN SCD 2424 400 TRANSITION AS REQUIRED B RETURN/ CEILING PRICE 6x6 100 OFF -WHITE FINISH EXHAUST LAY -IN PDDR 24x24 C RETURN/ CEILING PRICE 8x8 220 OFF -WHITE FINISH EXHAUST LAY -IN PDDR 24x24 RETURN/ CEILING PRICE 10x10 D EXHAUST LAY -IN PDDR 350 OFF-WHITE FINISH 24x24 RETURN/ CEILING PRICE 16x16 E EXHAUST LAY -IN PDDR 600 OFF-WHITE FINISH 2 4x24 NOTES: 1. ALL GRILLES / DIFFUSERS SERVING LOCKERS, KITCHEN, TOILETS AND JAN. CLOSETS TO HAVE ALUMINUM CONSTRUCTION. 2. ALL GRILLE DESIGNATIONS MAY NOT BE UTILIZED ON THIS PROJECT. 3. BASIS OF DESIGN - PRICE; EQUIVALENT PRODUCTS BY: CARNES, TITUS, AND KRUEGER. HOOD / LOUVER SCHEDULE SYMBOL TYPE LOCATION MANUFACTURER SIZE CFM REMARKS MODEL INTAKE WALL RUSKIN 48x72 1055 1, 2, 3, 4 LOUVER ELF -375DX REMARKS: 1. BIRD SCREEN 2. BAKED ENAMEL FINISH - COLOR BY OWNER. 3. COMPARABLE PRODUCTS BY ARROW, CESCO, AMERICAN WARMING & VENTILATING, EMPCO, & DOWCO 4. COORDINATE DIMENSIONS WITH EXISTING WINDOW DIMENSIONS PRIOR TO ORDERING. FAN SCHEDULE FAN # TYPE LOCATION CFM S.P. RPM HP VOLT -PH. MFG. & MODEL SONES ROOF OPG. REMARKS EF -1 EXHAUST ROOF 450 .5" 1620 1/10 120 -1 GREENHECK 7.1 10.5x10.5 1, 2, 3, 4, 5 #G- 075 -VG EF -2 EXHAUST ROOF 400 .5" 1620 1/10 120 -1 GREENHECK 1, 2, 3, 4, 5 #G- 075 -VG 0 NOTE: BASIS OF DESIGN - GREENHECK; EQUIVALENT PRODUCTS BY CARNES, COOK, & PENN REMARKS: 1. DISCONNECT SWITCH 2. BACKDRAFT DAMPER 3. PRE - FABRICATED ROOF CURB. COORDINATE WITH ROOF TYPE AND SLOPE. 4. ON PROGRAM CONTROL WITH LOCAL AHU ZONE TO RUN WHEN BLDG. IS OCCUPIED. 5. BIRD SCREEN 7 E-' A 0 C N C F G H WA AA R Kli =ENGINEERS Reece, Noland & McElrath, Inc. 94 Main Street Canton, North Carolina 28716 PHONE: 828 - 492 -0677 FAX: 828 - 492 -1054 MAIL @RNM - ENGINEERS. COM WWW.RNM- ENGINEERS.COM NC CERT. N0. C -0149 (C 2018 SEALS: m Z W J }} }}i]If7f1l o = ¢� CAR 0 U W `1� ` oneoav /f, ��JW ZNU O �.o7 cno OW SEAL _ - 0uiU-0 O w ?i u- ui m L i i --5 a Q N W f� , ° °�'ci;[n,4 K]. = V) U) z O F_ U Wz 0 W F_ LL Q 00. � Q _j Z W D 0 Z o m W 0 75 m F_ ::D J z W O c) U � W = V z U OW 0 REVISIONS /SU BM ISSIONS NO DATE ISSUED FOR 1 2 3 4 5 6 7 8 SHEET TITLE: MECHANICAL SUMMARY AND SCHEDULES ISSUED FOR: CONSTRUCTION DRAWN BY: DJM DRAWING NO. APPROVED BY: MRM PROJECT #: 2017108 0 .1 DATE: 05/07/2018 OF 8 SHEETS NOTES: 1. ALL GRILLES / DIFFUSERS SERVING LOCKERS, KITCHEN, TOILETS AND JAN. CLOSETS TO HAVE ALUMINUM CONSTRUCTION. 2. ALL GRILLE DESIGNATIONS MAY NOT BE UTILIZED ON THIS PROJECT. 3. BASIS OF DESIGN - PRICE; EQUIVALENT PRODUCTS BY: CARNES, TITUS, AND KRUEGER. HOOD / LOUVER SCHEDULE SYMBOL TYPE LOCATION MANUFACTURER SIZE CFM REMARKS MODEL INTAKE WALL RUSKIN 48x72 1055 1, 2, 3, 4 LOUVER ELF -375DX REMARKS: 1. BIRD SCREEN 2. BAKED ENAMEL FINISH - COLOR BY OWNER. 3. COMPARABLE PRODUCTS BY ARROW, CESCO, AMERICAN WARMING & VENTILATING, EMPCO, & DOWCO 4. COORDINATE DIMENSIONS WITH EXISTING WINDOW DIMENSIONS PRIOR TO ORDERING. FAN SCHEDULE FAN # TYPE LOCATION CFM S.P. RPM HP VOLT -PH. MFG. & MODEL SONES ROOF OPG. REMARKS EF -1 EXHAUST ROOF 450 .5" 1620 1/10 120 -1 GREENHECK 7.1 10.5x10.5 1, 2, 3, 4, 5 #G- 075 -VG EF -2 EXHAUST ROOF 400 .5" 1620 1/10 120 -1 GREENHECK 1, 2, 3, 4, 5 #G- 075 -VG 0 NOTE: BASIS OF DESIGN - GREENHECK; EQUIVALENT PRODUCTS BY CARNES, COOK, & PENN REMARKS: 1. DISCONNECT SWITCH 2. BACKDRAFT DAMPER 3. PRE - FABRICATED ROOF CURB. COORDINATE WITH ROOF TYPE AND SLOPE. 4. ON PROGRAM CONTROL WITH LOCAL AHU ZONE TO RUN WHEN BLDG. IS OCCUPIED. 5. BIRD SCREEN 7 E-' A 0 C N C F G H WA AA R Kli =ENGINEERS Reece, Noland & McElrath, Inc. 94 Main Street Canton, North Carolina 28716 PHONE: 828 - 492 -0677 FAX: 828 - 492 -1054 MAIL @RNM - ENGINEERS. COM WWW.RNM- ENGINEERS.COM NC CERT. N0. C -0149 (C 2018 SEALS: m Z W J }} }}i]If7f1l o = ¢� CAR 0 U W `1� ` oneoav /f, ��JW ZNU O �.o7 cno OW SEAL _ - 0uiU-0 O w ?i u- ui m L i i --5 a Q N W f� , ° °�'ci;[n,4 K]. = V) U) z O F_ U Wz 0 W F_ LL Q 00. � Q _j Z W D 0 Z o m W 0 75 m F_ ::D J z W O c) U � W = V z U OW 0 REVISIONS /SU BM ISSIONS NO DATE ISSUED FOR 1 2 3 4 5 6 7 8 SHEET TITLE: MECHANICAL SUMMARY AND SCHEDULES ISSUED FOR: CONSTRUCTION DRAWN BY: DJM DRAWING NO. APPROVED BY: MRM PROJECT #: 2017108 0 .1 DATE: 05/07/2018 OF 8 SHEETS REMARKS: 1. BIRD SCREEN 2. BAKED ENAMEL FINISH - COLOR BY OWNER. 3. COMPARABLE PRODUCTS BY ARROW, CESCO, AMERICAN WARMING & VENTILATING, EMPCO, & DOWCO 4. COORDINATE DIMENSIONS WITH EXISTING WINDOW DIMENSIONS PRIOR TO ORDERING. FAN SCHEDULE FAN # TYPE LOCATION CFM S.P. RPM HP VOLT -PH. MFG. & MODEL SONES ROOF OPG. REMARKS EF -1 EXHAUST ROOF 450 .5" 1620 1/10 120 -1 GREENHECK 7.1 10.5x10.5 1, 2, 3, 4, 5 #G- 075 -VG EF -2 EXHAUST ROOF 400 .5" 1620 1/10 120 -1 GREENHECK 1, 2, 3, 4, 5 #G- 075 -VG 0 NOTE: BASIS OF DESIGN - GREENHECK; EQUIVALENT PRODUCTS BY CARNES, COOK, & PENN REMARKS: 1. DISCONNECT SWITCH 2. BACKDRAFT DAMPER 3. PRE - FABRICATED ROOF CURB. COORDINATE WITH ROOF TYPE AND SLOPE. 4. ON PROGRAM CONTROL WITH LOCAL AHU ZONE TO RUN WHEN BLDG. IS OCCUPIED. 5. BIRD SCREEN 7 E-' A 0 C N C F G H WA AA R Kli =ENGINEERS Reece, Noland & McElrath, Inc. 94 Main Street Canton, North Carolina 28716 PHONE: 828 - 492 -0677 FAX: 828 - 492 -1054 MAIL @RNM - ENGINEERS. COM WWW.RNM- ENGINEERS.COM NC CERT. N0. C -0149 (C 2018 SEALS: m Z W J }} }}i]If7f1l o = ¢� CAR 0 U W `1� ` oneoav /f, ��JW ZNU O �.o7 cno OW SEAL _ - 0uiU-0 O w ?i u- ui m L i i --5 a Q N W f� , ° °�'ci;[n,4 K]. = V) U) z O F_ U Wz 0 W F_ LL Q 00. � Q _j Z W D 0 Z o m W 0 75 m F_ ::D J z W O c) U � W = V z U OW 0 REVISIONS /SU BM ISSIONS NO DATE ISSUED FOR 1 2 3 4 5 6 7 8 SHEET TITLE: MECHANICAL SUMMARY AND SCHEDULES ISSUED FOR: CONSTRUCTION DRAWN BY: DJM DRAWING NO. APPROVED BY: MRM PROJECT #: 2017108 0 .1 DATE: 05/07/2018 OF 8 SHEETS 0 NOTE: BASIS OF DESIGN - GREENHECK; EQUIVALENT PRODUCTS BY CARNES, COOK, & PENN REMARKS: 1. DISCONNECT SWITCH 2. BACKDRAFT DAMPER 3. PRE - FABRICATED ROOF CURB. COORDINATE WITH ROOF TYPE AND SLOPE. 4. ON PROGRAM CONTROL WITH LOCAL AHU ZONE TO RUN WHEN BLDG. IS OCCUPIED. 5. BIRD SCREEN 7 E-' A 0 C N C F G H WA AA R Kli =ENGINEERS Reece, Noland & McElrath, Inc. 94 Main Street Canton, North Carolina 28716 PHONE: 828 - 492 -0677 FAX: 828 - 492 -1054 MAIL @RNM - ENGINEERS. COM WWW.RNM- ENGINEERS.COM NC CERT. N0. C -0149 (C 2018 SEALS: m Z W J }} }}i]If7f1l o = ¢� CAR 0 U W `1� ` oneoav /f, ��JW ZNU O �.o7 cno OW SEAL _ - 0uiU-0 O w ?i u- ui m L i i --5 a Q N W f� , ° °�'ci;[n,4 K]. = V) U) z O F_ U Wz 0 W F_ LL Q 00. � Q _j Z W D 0 Z o m W 0 75 m F_ ::D J z W O c) U � W = V z U OW 0 REVISIONS /SU BM ISSIONS NO DATE ISSUED FOR 1 2 3 4 5 6 7 8 SHEET TITLE: MECHANICAL SUMMARY AND SCHEDULES ISSUED FOR: CONSTRUCTION DRAWN BY: DJM DRAWING NO. APPROVED BY: MRM PROJECT #: 2017108 0 .1 DATE: 05/07/2018 OF 8 SHEETS flnr.wginn Fnvelnna in. An n,; f1 nnR- 1RnA- AF7R- 9Rn7- nF7AAFR7d317 WA AA R Kli =ENGINEERS Reece, Noland & McElrath, Inc. 94 Main Street Canton, North Carolina 28716 PHONE: 828 - 492 -0677 FAX: 828 - 492 -1054 MAIL @RNM - ENGINEERS. COM WWW.RNM- ENGINEERS.COM NC CERT. N0. C -0149 (C 2018 SEALS: M Z W J Lu W }}}}i]If7f1l CAS J J ZNU00 -- cn 0 0 ui - � W `` Z(r�N W SEAL 0 0 ap-° �° ui = V) U) z O F- U uw z -j O wF- LL < 00. � � z w �rT- _ Q D 0 Z o m w o 75 m z =:)w O U � w= CD z Q rr U OW C) O rr rl REVISIONS /SUBMISSIONS NO DATE ISSUED FOR 1 2 3 4 5 6 7 8 SHEET TITLE: VRV SYSTEM SCHEDULES ISSUED FOR: CONSTRUCTION DRAWN BY: DJM DRAWING NO. APPROVED BY: MRM PROJECT #: 2017108 MO.2 DATE: 05/07/2018 OF 8 SHEETS nnaiGinn Fnvalnna in. Ann1 , nn oR- 9ROd- dF7R- 9FIl7- nF7AdF.17A.�17 AM AA R K14 =ENGINEERS Reece, Noland & McElrath, Inc. 94 Main Street Canton, North Carolina 28716 PHONE: 828 - 492 -0677 FAX: 828 - 492 -1054 MAIL @RNM - ENGINEERS. COM WWW.RNM- ENGfNEERS.COM NC CERT. N0. C -0149 © 2018 SEALS: m z w � O ° 27- U W ��ttt�irrrrr ,• CAR I"/ `�., • Qpvo9v Q fJJ Lu uj Oz U e �a� (~ O (n 0 (f' o Lw W L` O (� = Z SEAL ° ° �F NLJ Z � � �i LE (n � W f � as � ° rQ D W O C � Q o frI >� �''� M c Cn = Cn Of t- � V J z O F- C) wz —j O w� LL < 00, 0 J z W rr � _ Q I— @ Oz O m w o m F— Z z C3 ::Dw 0c) U � w= CD z Q oC O W -) O Of Cl- REVISIONS /SUBMISSIONS NO DATE ISSUED FOR 1 2 3 4 5 6 7 8 SHEET TITLE: VR V SYSTEM WIRING DIAGRAMS ISSUED FOR: CONSTRUCTION DRAWN BY: DJM DRAWING NO. APPROVED BY: MRM PROJECT #: 2017108 0 DATE: 05/07/2018 OF 8 SHEETS nnaiGinn Fnvalnna in. Ann1 , nn oR- 9ROd- dF7R- 9FIl7- nF7AdF.17A.�17 AM AA R K14 =ENGINEERS Reece, Noland & McElrath, Inc. 94 Main Street Canton, North Carolina 28716 PHONE: 828 - 492 -0677 FAX: 828 - 492 -1054 MAIL @RNM - ENGINEERS. COM WWW.RNM- ENGfNEERS.COM NC CERT. N0. C -0149 © 2018 SEALS: m z w � O ° 27- U W ��ttt�irrrrr ,• CAR I"/ `�., • Qpvo9v Q fJJ Lu uj Oz U e �a� (~ O (n 0 (f' o Lw W L` O (� = Z SEAL ° ° �F NLJ Z � � �i LE (n � W f � as � ° rQ D W O C � Q o frI >� �''� M c Cn = Cn Of t- � V J z O F- C) wz —j O w� LL < 00, 0 J z W rr � _ Q I— @ Oz O m w o m F— Z z C3 ::Dw 0c) U � w= CD z Q oC O W -) O Of Cl- REVISIONS /SUBMISSIONS NO DATE ISSUED FOR 1 2 3 4 5 6 7 8 SHEET TITLE: VRV SYSTEM PIPING DIAGRAMS ISSUED FOR: CONSTRUCTION DRAWN BY: DJM DRAWING NO. APPROVED BY: MRM PROJECT #: 2017108 MO.4 DATE: 05/07/2018 OF 8 SHEETS DocuSign Envelope ID AOD5DO06- 1BO4- 4F7B- 96D7- OF7A4E374317 A 3 C I E F G H 1 2 3 4 5 6 7 8 a WWW.RNM- ENGINEERS.COM NC CERT. N0. C -0149 © 2018 SEALS: co z w � • 0 o Lu OZ ( U O 4" O/A UP TO ATTIC IT ROOM (nONOw —OwwO (� = Z �(J)w SEAL ° 4 o w a a Z O �i L.� (n CC o N w •f� /�1�e @0(�[�j name. 15 ref �'C �''f�,firr�s +D'''� =C�z � w =II I1 m 4" 0/A UP TO ATTIC IU -1 -01 z O N I m U IU -1 -17 I❑I — 6" O/A UP TO ATTIC - I❑I I❑I IU -1 -18 O W �__ U IOFFICE O 0 — 0 -J z W rr ry- _ D Oz O W ww O G m (j z C3 Lu O c) U \� W = V z Q Ow O REVISIONS /SUBMISSIONS NO DATE ISSUED FOR 1 INOTE. 2 \ 3 o I UNDERCUT DOORS SHOWN ON ALL SPACES LESS THAN 4,038 CUBIC FEET. \ 5 I M.C. TO VERIFY EACH DOOR IS 1/2 INCH MINIMUM UNDERCUT (TYPICAL). \ \ 6 7 8 SHEET TITLE: FIRST FLOOR MECHANICAL PLAN ISSUED FOR: CONSTRUCTION DRAWN BY: DJM DRAWING NO. N MRM A A / / 6" O/A UP TO ATTIC 275 275 / 2017108 mi . 1 DATE: 05/07/2018 / I ❑I IU -1 -19 = 4" O/A UP TO ATTIC N CD // IU 1 02 I❑I / \ T I - 10" S/A UP TO ATTIC / cn o C-) \ \ ^� � T \ TO IU -1 -16 �m \ IU -1 -20 I❑I OFFICE D I� TYPICAL CEILING 3 a SUPPLY DIFFUSER A A I 1 4 D N. 275 275 n � ,o 4" 0/A UP TO ATTIC � PRECINCT MEETING STORAGE FOYER T) CEILING EXHAUST GRILLE. 10x10 / EXHAUST DUCT UP TO ATTIC. 1 26 1 35 A A T / 275 275 TYPICAL BRANCH c SELECTOR BOX. C 0/A 0 0 C) 4" UP TO ATTIC 22 TYPE 10" S/A UP TO ATTIC BS 3 IU 1 06 I❑I I❑I "C.. / � IU -1 -07 1❑1 IU -1 -21 \ III /� / a \ TYPICAL B LANCE DAMPER. / 0/ RESTROOM \ / REFER TO OUTSIDE AIR A A VOTING (WOMEN) SCHEDUL FOR VALUES. 275 275 B OFFICE \\ to MACHINE I / 925 1 12 N STORAGE 16x16 R/A UP TO ATTIC U �^ Lk- 0 ■o / 8x8 / TO IU 1 15 / � — / TYPE / TYPICAL CEILING RETURN GRILLE "C" BREAK ROOM IU -1 -03 I❑I �� D UC / UC B 25 925 4" 0/A UP TO ATTIC " /A UP TO ATTIC T RESTROOM — 6" O/A UP TO ATTIC o I I IU -1 -22 106 o TRANSITION DUCTWORK 6x6 E/A UP TO ATTIC ` T TYPICAL BRANCH TO O/A INLET (TYPICAL). OFFICE OFFICE E D D 109 108 B E 6x _ 225 225 BS 1 SELECTOR BOX. — 75 T 10x10 IU 1 10 1■1 IU 1 27 1❑1 C CORRIDOR f 190 c _P� _ — - - (SOUTH) — — L 1 O 4" 0/A UP TRANSFER GRILLES (TYPICAL) oX 1 OOD IU 1 11 I■I IU-1-12 1■1 TO ATTIC CEILING EXHAUST GRILLES. 8x8 p 225 T CORRIDOR OFFICE 0 FFI C E EXHAUST DUCT UP TO ATTIC. OFFICE (CENTRAL) 1 07 1 04A 137 100A E 103B 4" 0/A UP TO ATTIC IU -1 -13 I ❑ I UP _ C TYPICAL BRANCH 135 SELECTOR BOX. 1�1 IU -1 -23 0 D UC UC UC P BS -2 T T RESTROOM T O CORRIDOR 4" O/A UP (MEN) H 1 04 TO ATTIC 122 Uc M c 8x8 TYPE 6 "0 I U -1 -26 1 17 B "C" 6" O/A UP TO ATTIC CEILING EXHAUST GRILLE. 1 10 6" O/A UP TO ATTIC EXHAUST DUCT UP TO ATTIC. P T D C° D T 225 T T IC-) IU -1 -04 1 1 _ _ 0 22 UC TYPE TYPICAL TRANSFER GRILLE ❑ 4" 0/A UP TO ATTIC _ \ C TYPICAL BALANCE DAMPER. — IU -1 -14 I ❑1 T — / REFER TO OUTSIDE AIR IU-1-08 I ❑ 1 IU 1 09 1 I 1 ❑1 IU 1 24 6 " O/A UPT ATTIC SCHEDULE FOR VALUES. OFFICE T — — UC `r FOYER (EAST) CONDENSATE PUMPED TO OFFICE / J LOT 136 NEAREST HUB DRAIN - TYPICAL. 1 03 6"0 STORAGE 4"0 STORAGE TYPICAL WALL MOUNTED CONTROLLER (THERMOSAT). 117A 117 TYPICAL DUCT TRANSITION 6" O/A UP TO ATTIC � 6" 0/A UP TO ATTIC \ IU -1 -25 OFFICE nr IU -1 -05 1 ❑I TYPICAL 2x2CEILIN CA SETTE 02 FIRST FLOOR MECHANICAL PLAN z SCALE: 1/4" = 1' -0" 1 2 3 4 5 6 7 8 0 I C 4 E F G H i WA AA R Kli =ENGINEERS Reece, Noland & McElrath, Inc. 94 Main Street Canton, North Carolina 28716 PHONE: 828 - 492 -0677 FAX: 828 - 492 -1054 MAIL @RNM- ENGINEERS.COM WWW.RNM- ENGINEERS.COM NC CERT. N0. C -0149 © 2018 SEALS: co z w � Ifill CQ,Rf,' °�fi Lu OZ ( U O (nONOw —OwwO (� = Z �(J)w SEAL ° 4 o w a a Z O �i L.� (n CC o N w •f� /�1�e @0(�[�j name. �wOQ� � Q o ref �'C �''f�,firr�s +D'''� =C�z � w V J z O F_ U wz O W �__ LL Q O 0 O 0 -J z W rr ry- _ D Oz O W ww O G m (j z C3 Lu O c) U \� W = V z Q Ow O REVISIONS /SUBMISSIONS NO DATE ISSUED FOR 1 2 3 4 5 6 7 8 SHEET TITLE: FIRST FLOOR MECHANICAL PLAN ISSUED FOR: CONSTRUCTION DRAWN BY: DJM DRAWING NO. APPROVED BY: MRM PROJECT #: 2017108 mi . 1 DATE: 05/07/2018 OF 8 SHEETS DocuSign Envelope ID: AOD5DO06- 1BO4- 4F7B- 96D7- OF7A4E374317 A I C 11 E F G H 1 2 3 4 5 6 7 8 a WWW.RNM- ENGINEERS.COM NC CERT. N0. C -0149 (C 2018 SEALS: m Z W J O = � }} }}i]If7f1l 14j�\ C A ��JW :z (n cno OW — 0uiU-0 SEAL 4 "0 0/A DOWN 0 0 = V) TO IU -1 -17 =11 z O F_ U uw z 0 W F_ LL Q � 00. C Lu Im Oz 0 m W 0 75 m J J z Cn O c) U � W = V z U 2 I U OW C) 0 REVISIONS /SU BM ISSIONS NO DATE ISSUED FOR 1 "0 "0 c� 6 0/A DOWN 4 4 0/A DOWN 5 TO I U -1 -01 TO I U -1 -18 7 8 SHEET TITLE: ATTIC LEVEL MECHANICAL PLAN I O CONSTRUCTION DRAWN BY: DJM P zo APPROVED BY: MRM PROJECT #: 2017108 zo DATE: 05/07/2018 TYPICAL BALANCE DAMPER. OF 8 SHEETS REFER TO OUTSIDE AIR SCHEDULE FOR VALUES. l J r � C 6 "0 N 4" A DOWN 0 i o TO IU -1 -19 all 6 "0 0/A DOWN O/A INTAKE LOUVER - APPROX. 4'x6'. M.C. TO REMOVE 10' S/A DOWN TO CEILING a TO IU -1 -02 EXISTING WINDOW COMPLETELY, REPLACE WITH SUPPLY DIFUSERS TYPICAL BALANCE DAMPER. LOUVER, AND SEAL WEATHER- TIGHT. COORDINATE REFER TO OUTSIDE AI TO MATCH EXISTING WINDOW DIMENSIONS, SCHEDULE FOR VALUES. N O V m ' a TRANSITION DUCTWORK TO FULL SIZE OF LOUVER (TYPICAL). �0 4 "0 O/A DOWN N TO I U -1 -20 zo x 10 "0 1 0x1 0 E/A DOWN TYPICAL CONCEALED _ TO FIRST FLOOR TRANSITION DUCTWORK TO UNIT (TYPICAL). 10' S/A DOWN TO CEILING SUPPLY DIFUSERS DUCTED UNIT o I DOAS UNIT SUSPENDED IN ATTIC. =II w o a o IU -2 -01 m m Uo U o 16x16 R/A DOWN CEILING GRILLE IU -1 16 0/A DOWN 14"0 o TO IU-1-21 N 1 0 v o IU -1 24x10 15 0 10x12 16x12 SD N • SD C C "0 8"0 12 "10,10 12"0 AIR DUCTED 6 "0 8 "0 10 � P 6 0/A DOWN TO IU -1 -03 TO INDOOR UNITS. 8.10 4 "0 O/A DOWN TO I U -1 -27 6x6 E/A DOWN TO 4 "0 0/A DOWN FIRST FLOOR TO IU -1 -22 12x12 E/A DOWN UP TO EF -1 ON ROOF. 1 12x12 E/A DOWN UP TO EF -2 ON ROOF. co C co 16x16 R/A DOWN NEW FAN TO REPLACE EXISTING. NEW FAN TO REPLACE EXISTING. CEILING GRILLE COORDINATE WITH EXISTING CONDITIONS. COORDINATE WITH EXISTING CONDITIONS. 10x10 OUTSIDE AIR DUCTED TO INDOOR UNITS. 8x8 E/A DOWN TO FIRST FLOOR co OUTDOOR UNITS ON FLAT SECTION OF ROOF. OU 1 \ M.0 TO BE RESPONSIBLE FOR REMOVING o DN 60 EXISTING CONDENSING UNITS TO MAKE ROOM ox FOR NEW OUTDOOR UNITS. MODIFY EXISTING L _ J OR ADD NEW EQUIPMENT SUPPORTS BY PORTABLE PIPE HANGERS AND SUPPORTS. /A DOWN OU -2 �/ �� TO 10 C 6" O/A DOWN TO FIR 3T FLOOR 4 "0 0/A DOWN 1 0x1 0 E/A DOWN TO IU -1 -26 TO FIRST FLOOR C 6 "0 P 60 6 "0 O/A DOWN TO I U -1 -04 C 6 "0 4"0 DOWN TO I U-1 -24 U -1 6" O/A DOWN TO P FIRST FLOOR c U 6 "0 O/A DOWN 6 "0 O/A DOWN TO IU -1 -25 TO I U -1 -05 ATTIC LEVEL MECHANICAL PLAN z SCALE: 1/4" = V -0" 1 2 3 4 5 6 7 8 A 0 C N C F G H R Kli =ENGINEERS Reece, Noland & McElrath, Inc. 94 Main Street Canton, North Carolina 28716 PHONE: 828 - 492 -0677 FAX: 828 - 492 -1054 MAIL @RNM - ENGINEERS. COM WWW.RNM- ENGINEERS.COM NC CERT. N0. C -0149 (C 2018 SEALS: m Z W J O = � }} }}i]If7f1l 14j�\ C A ��JW :z (n cno OW — 0uiU-0 SEAL Z(r�Nw Lo' Ewd Of Q N� W ui = V) U) z O F_ U uw z 0 W F_ LL Q � 00. Q _j Z Lu D Oz 0 m W 0 75 m J J z W O c) U � W = V z U OW C) 0 REVISIONS /SU BM ISSIONS NO DATE ISSUED FOR 1 2 3 4 5 6 7 8 SHEET TITLE: ATTIC LEVEL MECHANICAL PLAN ISSUED FOR: CONSTRUCTION DRAWN BY: DJM DRAWING NO. APPROVED BY: MRM PROJECT #: 2017108 M1.2 DATE: 05/07/2018 OF 8 SHEETS DocuSign Envelope ID AOD5DO06- 1BO4- 4F7B- 96D7- OF7A4E374317 A 1 C 1 E F G H 1 2 3 4 5 6 7 8 a WWW.RNM- ENGfNEERS.COM NC CERT. N0. C -0149 © 2018 0 o co z W J CLEAN -OUT IT ROOM 1 15 Lu Oz U III Im (~ O (n 0 0 Lu �O Uw` = z CLEAN -OUT ��NL Z � � �i LE (n � w � Q o CO IU -1 -01 — IU-1 17 I ❑I _ CO — = Cn N I m I❑I I❑I IU -1 -18 U IOFFIG z — F_ w wz 1 16 3/4" CONDENSATE DRAIN - TYPIC AL � 00, 3/4" CONDENSATE DRAIN - TYPICAL UNLESS NOTED OTHERWISE. 0 J z W rr ry- _ UNLESS NOTED OTHERWISE. Oz 0 N G m Z 0 Lu 0c) U \� W = 3/4" z Ow NOTES: REVISIONS /SUBMISSIONS NO DATE 1. REFER TO MANUFACTURE'S VRV SYSTEM PIPING _ 1 DIAGRAM ON SHEET MO.4 FOR REFRIGERANT PIPING. I❑I IU -1 -19 3 2. TYPICAL REFRIGERANT PIPING TO BE ROUTED IN ATTIC. 3/4" CD N IU -1 -02 I I a t 5 I - 3/4" II n 7 1.. 8 SHEET TITLE: 0 MECHANICAL 3/4" ISSUED FOR: CONSTRUCTION U_ DJM IU -1 -20 APPROVED BY: MRM PROJECT #: 01 M1 . 3 1� 05/07/2018 110E I 0 OF 8 SHEETS N �o 1 4 D N. `, 3/4" PRECINCT MEETING TYPICAL STORAGE FOYER T) CONCEALED 1 26 1 1 0 DUCTED UNIT HD 135 _ TYPICAL BRANCH 0 � SELECTOR BOX (IN ATTIC). �\ INSTALL NEW HUB DRAIN ABOVE CEILING. CD — — CONNECT TO EXISTING WASTE PIPING (TYPICAL). IU -1 -06 I■I C]I IU 1 07 BS 3 — — — I❑I IU -1 -21 �II N RESTROOM 'L VOTING (WOMEN) IU 1 16 3/4" OFFICE to MACHINE 125 3/4" 112 N STORAGE U �^ IU -1 -15 ■ C9 ■ o 1" 314" BREAK ROOM IU -1 -03 I ❑I 1 05 3/4" 14" 3/4" FURNISH AND INSTALL RESTROOM UXILARY DRAIN PAN WITH FLOAT SWITCH I❑I IU -1 -22 1 06 \ BENEATH DUCTED UNITS — HUB DRAIN \ #IU1 -15 AND IU1 -16. OFFICE OFFIC- A _ 314" TYPICAL BRANCH IU IU -1 -10 -1 -27 SELECTOR BOX _ 1 09 1 08 — BS 1 (IN ATTIC). 1 ❑ 1 3/4 101 CLEAN -OUT CORRIDOR CLEAN -OUT — 3/4" HD — (SOUTH) 3/4" IU -1 -11 I ❑I IU -1 -12 I❑I CLE N -0 T ICO 11/4" CORRIDOR 3/4" 3/4" OF ICE 3 /4„ OFFICE L314" (CENTRAL) 3/4" OFFICE 7 104A 103B 137 COI 100A 1" Tup- I❑I IU -1 -13 _ HD -a* TYPICAL BRANCH — SELECTOR BOX (IN ATTIC). I❑I IU-1-23 BS -2 CORRIDOR INSTALL NEW HUB DRAIN ABOVE CEILING. ESTROOM 1" 3/4" EN) H - 1 04 CONNECT TO EXISTING WASTE PIPING (TYPICAL). CLEAN -OUT 1 2 314" 3/4" — 3/4" IU -1 -26 I ❑ICO — 3/4" IU -1 -04 I❑I 0 0 314" 3/4.. 3/4° � 0 0 — — IU -1 -14 I■I — IU 1 08 I■I IU 1 09 I❑I OFFICE I❑I IU-1-24 1 01 314" FOYER (EAST) CONDENSATE PUMPED TO OFFICE EARLY VOTING BALLOT 1 36 NEAREST HUB DRAIN - TYPICAL. 1 03 STORAGE STORAGE 117A 117 \CO 3/4" IU -1 -25 I❑I CLEAN OUT OFFICE 102 IU -1 -05 IF] 11 TYPICAL 2x2 CEILING CASS TTE FIRST FLOOR MECHANICAL PIPING PLAN z SCALE: 1/4" = 1' -0" 1 2 3 4 5 6 7 8 n 0 C E F G H i R K14 =ENGINEERS Reece, Noland & McElrath, Inc. 94 Main Street Canton, North Carolina 28716 PHONE: 828 - 492 -0677 FAX: 828 - 492 -1054 MAIL @RNM - ENGINEERS. COM WWW.RNM- ENGfNEERS.COM NC CERT. N0. C -0149 © 2018 SEALS: co z W J }111i1117ffr Lu Oz U e �a� (~ O (n 0 0 Lu �O Uw` = z SEAL ° 1 02 5 $ ��NL Z � � �i LE (n � w Q o �''� M = Cn V ) z O F_ U wz 0 LU � 00, 0 J z W rr ry- _ Oz 0 m ww 0 G m Z z C3 Lu 0c) U \� W = V z Ow -D O Of Cl- REVISIONS /SUBMISSIONS NO DATE ISSUED FOR 1 2 3 4 5 6 7 8 SHEET TITLE: FIRST FLOOR MECHANICAL PIPING PLAN ISSUED FOR: CONSTRUCTION DRAWN BY: DJM DRAWING NO. APPROVED BY: MRM PROJECT #: 2017108 M1 . 3 DATE: 05/07/2018 OF 8 SHEETS flnr.wginn Fnvelnna in. An n,; f1 nnR- 1RnA- AF7R- 9Rn7- nF7AAFR7d317 WA AA R Kli =ENGINEERS Reece, Noland & McElrath, Inc. 94 Main Street Canton, North Carolina 28716 PHONE: 828 - 492 -0677 FAX: 828 - 492 -1054 MAIL @RNM - ENGINEERS. COM WWW.RNM- ENGINEERS.COM NC CERT. N0. C -0149 (C 2018 SEALS: M Z W J Lu W }}}}i]If7f1l CAS J J ZNU00 -- cn 0 0 ui - � W `` W SEAL 0 0 Z(r�N ap-° �° ui = V) U) z O F- U uw z -j O wF- LL < 00. � � z w �rT- _ Q D 0 Z o m w o 75 m z =:)w O U � w= CD z Q rr U OW C) O rr rl REVISIONS /SUBMISSIONS NO DATE ISSUED FOR 1 2 3 4 5 6 7 8 SHEET TITLE: MECHANICAL DETAILS ISSUED FOR: CONSTRUCTION DRAWN BY: DJM DRAWING NO. APPROVED BY: MRM PROJECT #: 2017108 M2.1 DATE: 05/07/2018 OF 8 SHEETS DocuSign Envelope ID: AOD5DO06- 1BO4- 4F7B- 96D7- OF7A4E374317 ri 1 0 is C 0 E F G W o �o I RII ico C IO U CD t N I O N O I =II N O U �o ' N �o 9 O I II O o N to ■ ■ O ■o 2 GENERAL ELECTRICAL NOTES 3 1. THIS CONTRACTOR SHALL COORDINATE WITH ALL OTHER CONTRACTORS AND TRADES TO LOCATE HIS WORK TO AVOID CONFLICTS. 2. THIS CONTRACTOR SHALL NOT UTILIZE "THRU TYPE OUTLET BOXES WHERE DEVICES ARE SHOWN BACK TO BACK IN SOUND INSULATED OR SOUND SECURE AREAS, TYPICAL. 3. SMOKE DETECTORS FOR AIR HANDLING UNITS SHALL BE LOCATED IN AIR DUCTS OBSERVING ALL APPLICABLE CODES AND ORDINANCES. ELECTRICAL CONTRACTOR SHALL COORDINATE THE EXACT LOCATION AND REQUIREMENTS OF INSTALLATION WITH MECHANICAL CONTRACTOR PRIOR TO CUTTING DUCTWORK. LOCATE THE DETECTOR INDICATOR /RESET DEVICE IN AN ACCESSIBLE LOCATION AS DIRECTED BY THE ARCHITECT AND LABEL AS TO AREA AND ROOFTOP UNIT SERVED, TYPICAL. 4. MOUNTING HEIGHTS GIVEN ARE TO TOP OF OUTLET BOX, UNLESS OTHERWISE NOTED. HEIGHTS MAY BE ADJUSTED TO MATCH MASONRY JOINTS, AND MUST COMPLY WITH NORTH CAROLINA STATE BUILDING CODE VOLUME 1 -C. 5. ALL CONDUITS AND RACEWAYS ARE TO BE CONCEALED UNLESS OTHERWISE NOTED OR APPROVED BY THE DESIGNER. 6. ALL CONDUITS, SLEEVES, INSERTS, OUTLET BOXES, AND OTHER ROUGH -IN MATERIALS SHALL BE INSTALLED AS BUILDING CONSTRUCTION PROGRESSES. 7. ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 8. IN RECEIVING AND OTHER AREAS WHERE ITEMS SUCH AS EXIT SIGN, FIRE ALARM DEVICES, ETC., ARE SUBJECT TO DAMAGE, PROVIDE AND INSTALL GUARDS AS RECOMMENDED BY THE MANUFACTURER. 9. THE SYMBOL " " DENOTED GROUNDING CONDUCTOR, TYPICAL UNLESS OTHERWISE NOTED, ALL CONDUITS SHALL BE 3/4" MINIMUM. 10. ALL PANEL DIRECTORIES SHALL BE TYPED AS TO THE LOAD SERVED AND USING THE OWNER'S NUMBERING SYSTEM. 11. ALL WIRING TROUGHS SHALL BE A MINIMUM OF 8" DEEP. 12. ALL ELECTRICAL PANELS TO BE LABELED WITH PHENOLIC LABELS. GENERAL NOTES FOR ELECTRICAL DEMOLITION 1. LIGHTING, POWER, DATA, INTERCOM, SECURITY - CONTRACTOR MAY REUSE EXISTING CONDUIT & WIRING TO THE EXTENT POSSIBLE IN PROVIDING A COMPLETE & OPERABLE SYSTEM. CONTRACTOR IS TO PROVIDE ALL LABOR & MATERIALS, INCLUDING BUT NOT LIMITED TO DEVICES, BOXES, CONDUIT, & WIRING FROM ALL DEVICES TO APPROPRIATE DISTRIBUTION /CONTROL PANEL IN ORDER TO PROVIDE A COMPLETE & OPERABLE SYSTEM. CONTRACTOR TO FIELD VERIFY ALL EXISTING QUANTITIES & LOCATIONS & COORDINATE CLOSELY WITH OWNER. 2. E.C. TO TAKE CARE IN REMOVING, TAGGING, & STORING DEVICES DURING DEMO PHASE, & REPLACING DEVICES TO BE REUSED DURING NEW CONSTRUCTION PHASE. EXISTING CEILING MOUNTED DEVICES TO BE REINSTALLED AS CLOSE AS POSSIBLE TO ORIGINAL LOCATION. PROVIDE MATERIAL & LABOR FOR EXTENDING CONDUIT & WIRING, AS REQUIRED, FOR REINSTALLATION. ENSURE PROPER OPERATION AFTER CONSTRUCTION. 3, WHERE RECEPTACLES ARE REMOVED, ELECTRICAL CONTRACTOR TO REMOVE EXISTING RECEPTACLE DEVICE, BOX, CONDUIT & WIRING BACK TO IT'S SOURCE. WHERE CIRCUIT FEEDING RECEPTACLE TO BE REMOVED ALSO FEEDS RECEPTACLES THAT ARE TO REMAIN, ELECTRICAL CONTRACTOR SHALL PROVIDE CONDUIT, WIRING & BOXES AS REQUIRED TO RE -FEED EXISTING RECEPTACLES, AS REQUIRED, FOR PROPER OPERATION. EXISTING BUILDING NOTES 1. WHERE NOTED, REMOVE ALL CONDUIT, WIRING, & ELECTRICAL EQUIPMENT, INCLUDING PREVIOUSLY ABANDONED, RENDERED USELESS BY CONSTRUCTION. 2. ALL MATERIALS REMOVED & NOT TO BE REUSED ARE TO BE DISPOSED OF PER OWNER'S INSTRUCTIONS. 3. EXISTING WIRING & RACEWAYS TO BE REUSED WHERE POSSIBLE OR PRACTICAL, & EXISTING WIRING IS FOUND TO BE IN GOOD CONDITION; REPLACE ANY EXISTING WIRING FOUND TO BE IN POOR CONDITION. ALL NEW INSTALLATIONS SHALL USE NEW WIRE, TYPICAL. 4. EXISTING WIRING, DEVICES, ELECTRICAL PANELS, ETC. ARE SHOWN LIGHTER & DASHED. 4 1 5 ELECTRICAL SPECIFICATIONS IT IS THE INTENT OF THESE SPECIFICATION FOR THE ELECTRICAL CONTRACTOR TO FURNISH A COMPLETE ELECTRICAL SYSTEM, FULLY ADJUSTED, & READY FOR USE. ALL ELECTRICAL WORK TO BE DONE IN STRICT ACCORDANCE WITH THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE OBSERVING ALL STATE AND LOCAL CODES. ELECTRICAL CONTRACTOR SHALL GIVE ALL NECESSARY NOTICES, OBTAIN ALL PERMITS & PAY ALL SALES TAXES, UTILITY COMPANY CHARGES FOR SERVICE, PERMITS, FEES, & OTHER COSTS IN CONNECTION WITH HIS WORK. ELECTRICAL CONTRACTOR TO ENSURE THAT ALL MATERIAL & EQUIPMENT FURNISHED FOR THIS PROJECT SHALL BE U.L. LISTED. THE MATERIAL & EQUIPMENT HAS BEEN CAREFULLY SELECTED FOR THIS PROJECT & THE ELECTRICAL CONTRACTOR IS EXPECTED TO PROVIDE ALL ITEMS AS CLOSELY AS POSSIBLE TO THE SPECIFICATIONS & AS CALLED FOR ON THE DRAWINGS. ELECTRICAL CONTRACTOR SHALL SUBMIT THREE (3) SETS OF EQUIPMENT DATA SHOP DRAWINGS TO THE ENGINEER FOR ALL ITEMS TO BE FURNISHED & INSTALLED FOR APPROVAL. ELECTRICAL CONTRACTOR SHALL INCLUDE IN THE WORK WITHOUT EXTRA COST TO THE OWNER ANY LABOR MATERIALS SERVICES, APPARATUS, DRAWINGS, INCIDENTAL CONSTRUCTION WORK, ETC., IN ORDER TO COMPLY WITH ALL APPLICABLE LAWS, ORDINANCES, & REGULATIONS, WHETHER. OR NOT SHOWN ON DRAWINGS AND /OR SPECIFIED. NO CLAIM FOR EXTRAS WILL BE APPROVED WITHOUT PRIOR COORDINATION FOR CONFLICTS BY CONTRACTOR, & WRITTEN REQUEST & APPROVAL PRIOR TO PERFORMING WORK. ALL WORK & EQUIPMENT TO BE GUARANTEED BY CONTRACTOR FOR ONE (1) YEAR. UPON COMPLETION OF ALL WORK & ALL TESTS, ELECTRICAL CONTRACTOR SHALL INSTRUCT THE OWNER OR HIS REPRESENTATIVE FULLY IN THE OPERATIONS, ADJUSTMENTS, & MAINTENANCE OF EQUIPMENT FURNISHED. ELECTRICAL CONTRACTOR SHALL PROVIDE OWNER WITH MAINTENANCE SCHEDULE FOR THE PRINCIPAL ITEMS OF EQUIPMENT FURNISHED. MANUFACTURER'S ADVERTISING LITERATURE OR CATALOGS WILL NOT BE ACCEPTABLE. ALL MATERIALS & EQUIPMENT TO BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS & GOOD RECOMMENDED PRACTICES. ELECTRICAL CONTRACTOR SHALL GIVE FULL COOPERATION TO OTHER TRADES. WHERE THE WORK OF ELECTRICAL CONTRACTOR WILL BE INSTALLED IN CLOSE PROXIMITY TO, OR WILL INTERFERE WITH WORK OF OTHER TRADES, HE SHALL ASSIST IN WORKING OUT SPACE CONDITIONS TO MAKE SATISFACTORY ADJUSTMENTS. IF ELECTRICAL CONTRACTOR INSTALLS HIS WORK BEFORE COORDINATING WITH OTHER. TRADES, HE SHALL MAKE THE NECESSARY CHANGES IN HIS WORK TO CORRECT THE CONDITION WITHOUT EXTRA CHARGE. THE DRAWINGS ARE DIAGRAMMATIC & INDICATE THE GENERAL ARRANGEMENTS OF SYSTEMS & WORK INCLUDED IN THE CONTRACT. THE DRAWINGS ARE NOT TO BE SCALED. ELECTRICAL CONTRACTOR TO VERIFY EXACT LOCATION OF EQUIPMENT, ROUTING PIPE, ETC., & WORK CLOSELY WITH OTHER TRADES TO AVOID CONFLICTS. ELECTRICAL CONTRACTOR TO LOCATE & INSTALL ELECTRICAL CONTROL PANELS IN SUITABLE LOCATION WITH APPROPRIATE CLEARANCES & OVERLOAD PROTECTION FOR ALL ITEMS REQUIRED. ELECTRICAL CONTRACTOR MAY COMBINE CONDUITS WHERE APPLICABLE, BUT MUST HOOK UP ITEMS TO PROPER CIRCUITS AS SHOWN. THE OWNER., ARCHITECT & ELECTRICAL CONTRACTOR TO COORDINATE FOR PROPER CUTOUT HOLES, ALL STUB -UPS & JUNCTION BOXES, & TO VERIFY LOCATIONS. ALL CONDUCTORS TO BE COPPER WITH TYPE THHW OR XHHW INSULATION UNLESS OTHERWISE NOTED. WHERE ALUMINUM CONDUCTORS ARE UTILIZED THEY SHALL BE TERMINATED WITH BURNDY HY -PLUG, HYDRAULIC COMPRESSION TERMINATORS. EXTERIOR MOUNTED BOXES SHALL HAVE APPROVED WEATHERPROOF PLATES &/OR COVERS. ALL SURFACE INSTALLED BOXES SHALL HAVE NYLON DEVICE PLATES. ALL DEVICE OUTLETS SHALL BE FLUSH MOUNTED UNLESS SPECIFICALLY NOTED. ALL FIXED ELECTRICAL EQUIPMENT INCLUDING RECEPTACLES SHALL BE LABELED WITH A REFERENCE TO THE CIRCUIT & PANEL OF ORIGIN. ALL PANELS SHALL BE LABELED WITH PANEL NAME & SOURCE OF SUPPLY. ALL PANEL DIRECTORIES SHALL USE ROOM IDENTIFICATIONS TO BE SUPPLIED BY THE OWNER, NOT THE ROOM NAMES & NUMBERS ON THE DRAWINGS. ALL LABELS REFERRING TO EMERGENCY POWER SHALL BE PER FACILITIES CURRENT COLOR CODE. CONDUIT, WIRING, & ELECTRICAL EQUIPMENT & DEVICES CAUSED TO BE ABANDONED OR RENDERED USELESS BY CONSTRUCTION SHALL BE REMOVED BACK TO THE SOURCE. IN ADDITION, CONDUIT, WIRING, ELECTRICAL EQUIPMENT & DEVICES DISCOVERED ABANDONED WITHIN THE LIMITS OF CONSTRUCTION SHALL BE REMOVED BACK TO THE SOURCE, EVEN IF THIS SHOULD INVOLVE REMOVAL OUTSIDE THE LIMITS OF CONSTRUCTION. SUPPLEMENTAL ELECTRICAL SPECIFICATIONS ALL PENETRATIONS OF RATED PARTITIONS, FLOOR SLABS BY EITHER NEW OR EXISTING CONDUITS SHALL BE FIRE CAULKED OR CLOSED BY APPROVED U.L. METHODS BY THE ELECTRICAL CONTRACTOR. ELECTRICAL CONTRACTOR TO MAINTAIN A COMPLETE SET OF CONSTRUCTION DOCUMENTS WITH AS -BUILT CONDITIONS & TURN OVER TO THE OWNER. ALL No. 10 & No. 12 CONDUCTORS FOR RECEPTACLES & LIGHTING CIRCUITS SHALL BE STRANDED COPPER. ALL TERMINATIONS SHALL BE NUMBERED AND LABELED. ALL CONDUCTORS SHALL BE MARKED WITH CIRCUIT NUMBER WHEN TERMINATING AT THE PANELBOARD. ALL 15A, 20A, & 30 AMPERE HOME RUN CONDUCTORS EXCEEDING 150' SHALL BE INCREASED ONE WIRE SIZE TO COMPENSATE FOR VOLTAGE DROP. ADJUST CONDUIT SIZE ACCORDINGLY. ALL CONDUIT COUPLINGS AND CONNECTORS SHALL BE "T &B" INSULATED THROAT COMPRESSION TYPE. NO "INDENTER" OR SET SCREW DEVICES WILL BE ALLOWED, TYPICAL. ALL PENETRATIONS THROUGH FLOOR SLAB OR RATED ASSEMBLIES SHALL BE APPROVED BY THE OWNER, ARCHITECT & STRUCTURAL ENGINEER PRIOR TO CUTTING OR BORING. ALL PENETRATIONS SHALL BE SLEEVED, FIRE CAULKED & FINISHED WITH COLLAR ON BOTH SIDES. ANY PENETRATION NOT COORDINATED WILL RESULT IN CONTRACTOR BEARING ALL COSTS ASSOCIATED WITH PATCHING, REPAIRING & REFINISHING AREA TO THE SATISFACTION OF THE OWNER & ENGINEER. ALL ELECTRICAL "TIE -INS" & "SHUT- DOWNS" SHALL BE COORDINATED WITH THE OWNER PRIOR TO COMMENCEMENT OF WORK. CONTRACTOR SHALL NOTIFY OWNER A MINIMUM OF 72 HOURS PRIOR TO ANY SUCH WORK. ALL EXISTING EQUIPMENT, CONDUIT, WIRING, BOXES ETC. RENDERED UNUSED, SHALL BE REMOVED & DISPOSED OF AS DIRECTED BY THE OWNER. 0 7 ELECTRICAL SYMBOL SCHEDULE Duct - Mounted Smoke Detector. Match existing. Connect to SD D existing Fire Alarm system. ABBREVIATIONS ACT ..............ABOVE NOTE: EXISTING DEVICES SHOWN LIGHTER AND WITH DASHED LINES. ATS ..............AUTOMATIC ALL SYMBOLS MAY NOT BE USED AFF ..............ABOVE FINISHED FLOOR SEE SPECIFICATIONS FOR A COMPLETE LISTING OF MFG'S SYMBOL DESCRIPTION MOUNTING S Switch, single pole, 20 amp, commercial duty, Bryant #4901 Leviton #1221 120/277 4' -0" AFF t Top SEALS: or volt rated. or as noted EWC .............ELECTRIC Receptacle, industrial grade, duplex, Bryant #5252 EWH .............ELECTRIC WALL HEATER Leviton #5252, 15 ampere rated, grounding type, 1' -6" AFF GC ...............GENERAL 2 pole, 3 wire, 125 volts. GWH .............GAS WALL HEATER Receptacle, same as above except mounting height. 0' -6" ACT or as noted MCCB ........... Double Duplex Receptacle, (2) Bryant #5252 or 1' -6" AFF -FUSED DISCONNECT SWITCH (2) Leviton #5252, 15 ampere rated, grounding type. unless noted RTU ..............ROOFTOP Receptacle, same as above except mounting height. 0' -6" ACT or as noted UNDERGROUND Ground fault circuit interrupting receptacle, 15 amp, 1' -6" AFF XFMR ........... feed -thru type, standard duty, Bryant #GFR52FT. ®z O m ww o Receptacle, same as above except mounting height. 0' -6" ACT or as noted VVP Receptacle, same as above with Weather Proof cover. V-6" n or as as noted 0c) Receptacle, industrial grade, duplex, Bryant #5362 :1&20A Leviton #5362, 20 ampere rated, grounding type, 1'4' AFF 2 pole, 3 wire, 125 volts. U OW -Cr-20A Receptacle, same as above except mounting height. 0' -6" ACT or as noted 30A Receptacle, Locking, 125 volt rated, 30 amp, 2 pole, 3 wire, 1' -6" AFF Bryant #70530 -FR with mating plug and cord. as noted 30A Receptacle, 250 volt rated, 30 amp, 3 pole, 4 wire, 1' -6" AFF Bryant #9430 -FR with mating plug and cord. as noted New conduit/wiring - - - -- Home run to panelboard. Arrowheads indicate number of As Required circuits. 7 Disconnect switch, 600V. Where exposed to weather shall As Required, be NEMA 3R. Square " T safety switch or equal. no higher than ELECTRICAL SYMBOLS, SPECIFICATIONS & 6' -6" AFF ■ Junction box (JB) as manufactured by RACO, Steel City, or As required JWC Universal. Size as applicable or required. APPROVED BY: I Fs-s Surge Suppresser Mnt, on Service E1.0 See specifications. Distribution Eq. Electrical panelboard, see panel schedule for description. 6-6" to top Duct - Mounted Smoke Detector. Match existing. Connect to SD D existing Fire Alarm system. ABBREVIATIONS ACT ..............ABOVE COUNTER TOP ATS ..............AUTOMATIC TRANSFER SWITCH AFF ..............ABOVE FINISHED FLOOR AHU .............AIR HANDLER UNIT AFG ..............ABOVE FINISHED GRADE BCT ..............BELOW COUNTER TOP CLG ..............CEILING SEALS: EC ................ELECTRICAL CONTRACTOR EWC .............ELECTRIC WATER COOLER EWH .............ELECTRIC WALL HEATER FDS ..............FUSED DISCONNECT SWITCH GC ...............GENERAL CONTRACTOR GWH .............GAS WALL HEATER MC ...............MECHANICAL CONTRACTOR MCCB ........... MOLDED CASE CIRCUIT BREAKER NFD .............NON -FUSED DISCONNECT SWITCH PC ............... PLUMBING CONTRACTOR RTU ..............ROOFTOP UNIT UG ............... UNDERGROUND WCP .............WATER CIRCULATION PUMP XFMR ........... TRANSFORMER f 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 11 1.1 C I E F G 2 RK14 MILSICISILILUS Reece, Noland & McElrath, Inc. 94 Main Street Canton, North Carolina 28716 PHONE: 828 - 492 -0677 FAX: 828 - 492 -1054 MAIL@RNM- ENGMEERS.COM WW W.RNM- ENGINEERS.COM NC CERT. N0. C -0149 (D 2018 SEALS: M Z LZ J O of Z }lllil9lf+JJ ��� °4 CA,RO, /�Ji oOf aUjz Z(nU�O cn 0 0 Uj — U W� U c� = z cnw _ EAL _ v c — �y /fC'ry ° QONOw Of M p rf�✓} J 0 v N v G` o ❑ r�'� ��Q_ C/) Z O U W Z O W� LL U 00, 0 _ z LU r _ D ®z O m ww o G m J Z J z0 LU 0c) U � W = V Z U OW 0 W Q_ REVISIONS /SUBMISSIONS NO DATE ISSUED FOR 1 2 3 4 5 6 7 8 SHEET TITLE: ELECTRICAL SYMBOLS, SPECIFICATIONS & NOTES ISSUED FOR: CONSTRUCTION DRAWN BY: JWC DRAWING NO. APPROVED BY: I JSD PROJECT #: 2017108 E1.0 DATE: 05/07/2018 OF 2 SHEETS DocuSign Envelope ID: AOD5DO06- 1BO4- 4F7B- 96D7- OF7A4E374317 • Kq ENGINEERS Reece, Noland & McElrath, Inc. 94 Main Street Canton, North Carolina 28716 PHONE: 828 - 492 -0677 FAX: 828 - 492 -1054 MAIL@RNM- ENGINEERS . COM WWW.RNM- ENGINEERS.COM NC CERT. N0. C -0149 © 2018 SEALS: m O Z w C✓ �E1tirr��rrir tiw CARP Lu 0 < CD z 0 n o "' o c W o' 4 EAL a _ � r� � a e Z O §i LE Of ov W Q �' any ,rr a° J e� ! O O V) UJr�P<<7PIItI11V,,� Of J � tl Cl) z O U wz J O wF= LL < 00, � 0 1 z w rr _ Q D 077 O m w o m z0 =Dw O C) U � w= CD z Q er U OW O tr tl REVISIONS /SUBMISSIONS NO DATE ISSUED FOR 1 2 3 4 5 6 7 8 SHEET TITLE: ELECTRICAL PLANS ISSUED FOR: CONSTRUCTION DRAWN BY: JVVC DRAWING NO. APPROVED BY: JSD PROJECT #: 2017108 E2.0 DATE: 05/07/2018 OF 2 SHEETS