Loading...
HomeMy WebLinkAboutAgenda - 06-27-2006-5rORANGE COUNTY BOARD OF COMMISSIONERS ACTION AGENDA ITEM ABSTRACT Meeting Date: .June 27, 2006 Action Agenda Item No....~' - (' SUBJECT: Bid Award: Emergency Generators DEPARTMENT: Purchasing and Emergency PUBLIC HEARING: (YIN) No Management ATTACHMENT(S): Bid Tabulation INFORMATION CONTACT: Pam Jones, (919) 245-2652 Jack Ball, (919) 968-2050 PURPOSE: To award a bid to Tarheel Generator of Siler City, North Carolina for one (1) 200 kW diesel powered generator for standby power for the Orange County EMS-911 Center at 1914 New Hope Church Road, Chapel Hill and for one (1) 50 kW diesel powered generator for standby power for the Eno Mountain Communication Tower. BACKGROUND: At the April 10, 2006 regular meeting, the Board of Commissioners adopted a grant project ordinance appropriating $92,986 in federal and State grant funding for the acquisition and installation of replacement emergency generators at the County's Emergency Management and 9-1-1 Center on New Hope Church Road, and at the Eno Mountain Tower site. No County funds are involved in this project, and staff recommend that the Board award bids far these two generators as outlined below. Currently, the EMS-91 1 Center is connected to a 50 KW diesel generator that has been in service for more than twelve years. This generator is only able to power roughly half of facility in the event of power outages. Although the communications consoles and other critical equipment are connected to this generator, staff recommend that the entire building be capable of operation in the event of power failures. The second generator that would be purchased under this award would replace the more than 20-year old 37 KW generator that supplies back up power to the Eno Mountain Communications building. Both the capacity of the existing generator to serve the equipment at the site and the extreme unreliability of the automatic transfer switch are drivers that prompt the replacement request. After an evaluation of current and potential peak demand by the County's electrician, in conjunction with the electrical inspector from the Planning Department, it was determined that (1) 200 kW diesel powered generator would be the best solution for Orange County EMS-911 Center; and a 50 kW diesel powered generator would best serve the Eno Mountain Communication Tower. Bath of the subject facilities are served by single-phase, rather than three-phase power, thereby necessitating greater generator capacity. This sizing will allow the generators to operate more efficiently since their capacity is not at maximum loads and will provide for additional future load in the existing facilities. As an example, the generator to be installed on Eno Mountain will serve additional equipment that will inevitably be installed over time. While the Administrative Division of Emergency Management will relocate within the next few months to the newly acquired building in the Meadowlands, in order to maintain flexibility of use of the building by a large number of people, particularly during disaster response, the original generator sizing has been maintained. Solar power generators were considered, but that option was denied by the State during the grant solicitation process due to cast and feasibility considerations, Eleven potential bidders received copies of the bid package. Bids were received from five firms, with Tarheel Generator of Siler City, North Carolina submitting the lowest responsible bid that was responsive at cost of $61,553.20 and $29,195,31 far the 911 Center and Eno Tower site respectively.. The total cost for both projects is $90,748.51, and, in addition to the generator, the bid includes an automatic transfer switch and all necessary labor to successfully install the equipment, The generator at the 911 Center will be installed with no disruption of services, Delivery, and installation will occur within 14-16 weeks. Staff will assess the condition of the current equipment for possible re-assignment, Current staff thinking is that the existing generator from New Hope Church Road would be redeployed to the recently acquired County building at 510 Meadowlands Drive, and that the existing Eno Mountain generator will be evaluated far potential use as atrailer-mounted mobile emergency power resource. FINANCIAL IMPACT: The Federal Emergency Management Agency (FEMA) has granted approval far these two generators and authorized funding through a special allocation of hazard mitigation funds. The specific allocation for this project is provided through the Hurricane Isabel mitigation grant allocation, The total grant award for this project is $92,986. The bid award contemplated by this action is $90,748.51, 75% of which would be paid through FEMA funds, 25% of which would be paid through NCDEM funds, The remaining balance of the grant would be allocated far overhead. As noted above, the Board has already approved a Hazard Mitigation Generator Project grant project ordinance to account far the receipt of these funds; therefore, no further budget action is required of the BOCC. RECOMMENDATION(S): The Manager recommends that the Board award a bid to Tarheel Generator of Siler City, North Carolina for a total of $90,748.51; and authorize the Purchasing Director to execute the necessary paperwork. BID TABULATION BID # 259 BID FOR: STANDBY GENERATORS BID AWARDED TO: CLOSING DATE: 6-7-06 BID PRICE: CLOSING TIME: 11:00 AM BUDGETED AMOUNT: 200K DIESEL GENERATOR 50K DIESEL INSTALLED W/ GENERATOR AUTO INSTALLED W/ TOTAL BID, TRANSFER AUTO TRANSFER BOTH VENDOR LOCATION SWITCH SWITCH GENERATORS TAR HEEL Siler Cit , NC $61,553.20 $29,195.31 $90,748.51 BRYANT DURHAM Durham, NC $79,399.00 $44,941.00 $124,340.00 CUMMINS Greensboro, NC $77,300.00 $45,400.00 $122,700.00 Hillsborough, E & W ELECTRICAL NC $95,487.10 $36,060.40 $131,547.50 NIXON POWER Charlotte NC $104,259.00 $37,677.00 $141,936.00