Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2017-277-E AMS - National Power Corporation for generator purchases, installation
DocuSign Envelope ID: B5986604-2420-4A6E-BD13-01F64E43BD25 [Departmental Use Only] TITLE Standby Generator Installation FY 2017-18 NORTH CAROLINA CONSTRUCTION AGREEMENT OVER$250,000.00 ORANGE COUNTY THIS CONSTRUCTION AGREEMENT (hereinafter called "Agreement"), made as of the 6th day of July, 2017, by and between National Power Corporation, (hereinafter called the "Contractor"), and Orange County, a political subdivision of the State of North Carolina, (hereinafter called the "County," "Orange County," or"Owner"). WITNESSETH: That the Contractor and the Owner, for the consideration herein named, agree as follows: 1. CONTRACT DOCUMENTS; PRIORITY The Contract Documents consist of this Agreement, the General Conditions which are fully incorporated in this Agreement, the Request for Proposals, designer approved communications and/or field orders, the Proposal, Construction Documents and Drawings and Written Specifications, and the terms and conditions of sale. The Contract Documents form the Contract. In the event of any inconsistency between or among the Contract Documents the Contract Documents shall be interpreted in the following order of priority: a. This Agreement and incorporated General Conditions attached as Exhibit 1. b. Designer approved and stamped construction documents and drawings and written specifications. c. Designer approved communications and/or field orders. d. Request for Proposals and addenda thereto. e. Proposal-Custom Quote Dated April 28, 2017. f. National Power Corporation Terms and Conditions of Sale. 2. SCOPE OF WORK The Contractor shall furnish and deliver all of the materials, and perform, and be fully responsible for all of the Work required by this Agreement within the time period stipulated in a written Notice-to-Proceed to be executed by the Contractor and Owner and in accordance with the following enumerated documents, which are made a part hereof as if fully contained herein: a. Construction Drawings prepared by N/A b. Written specifications prepared by the designer. c. Contractor generator fabrication and installation proposal dated April 28, 2017, itemized by Revised 2/17 1 DocuSign Envelope ID: B5986604-2420-4A6E-BD13-01F64E43BD25 location and selected contractual scope of work per location. Selected scope of work sections and the corresponding proposed costs per location include the base generator, options, design, installation materials, installation labor, and required crane services which fully describes the work to be performed, such work(hereinafter called the "Work"). d. Related documents listed under Section 1 above. 3. TERM AND SCHEDULING a. The Contractor agrees to commence work pursuant to the written Notice-to Proceed. b. The Contractor agrees to complete substantially all Work included by November 31st, 2017. c. Time is of the essence with respect to all dates specified in the Contract Documents as Completion Dates. d. The Contractor shall perform the Work in the time, manner and form required by the Contract Documents and as stipulated in a written Notice-to-Proceed to be executed by the Contractor and Owner. 4. STANDARD OF CARE AND DUTIES OF CONTRACTOR a. The Contractor shall exercise reasonable care and diligence in performing the Work in accordance with the generally accepted standards of this type of Contractor practice throughout the United States and in accordance with applicable federal, state and local laws and regulations applicable to the performance of these services. Contractor is solely responsible for the professional quality, accuracy and timely completion and/or submission of all work. b. The Contractor shall not load or permit any part of the Work to be loaded with a weight that will endanger its safety, intended performance or configuration. c. Contractor shall be responsible for all Contractor, Subcontractor, and Sub-subcontractor errors or omissions, in the performance of the Agreement together with the errors and omissions of any agent or employee of the Contractor or any Subcontractor or Sub-subcontractor. Contractor shall correct any and all errors, omissions, discrepancies, ambiguities, mistakes or conflicts at no additional cost to the Owner. d. Contractor is an independent contractor of Owner. Any and all employees of the Contractor engaged by the Contractor in the performance of any work or services required of the Contractor under this Agreement, shall be considered employees or agents of the Contractor only and not of the Owner, and any and all claims that may or might arise under any workers compensation or other law or contract on behalf of said employees while so engaged shall be the sole obligation and responsibility of the Contractor. e. Contractor shall at all times remain in compliance with all applicable local, state, and federal laws, rules, and regulations including but not limited to all state and federal -discrimination laws, policies, rules, and regulations and the Orange County Non-Discrimination Policy and Orange County Living Wage Policy (each policy is incorporated herein by reference and may be viewed at http://www.orangecountync.gov/departments/purchasing division/contracts.php). Any violation of the Orange County Non-Discrimination Policy is a breach of this Agreement Revised 2/17 2 DocuSign Envelope ID: B5986604-2420-4A6E-BD13-01F64E43BD25 and County may immediately terminate this Agreement without further obligation on the part of the County. This paragraph is not intended to limit and does not limit the definition of breach to discrimination. f. If activities related to the performance of this Agreement require specific licenses, certifications, or related credentials Contractor represents that it and/or its employees, agents and subcontractors engaged in such activities possess such licenses, certifications, or credentials and that such licenses certifications, or credentials are current, active, and not in a state of suspension or revocation. g. The Contractor shall supervise and direct the Work efficiently and with the Contractor's best skill and attention. Except as specifically set forth in the Contract Documents the Contractor shall be solely responsible for the means, methods, techniques, sequences and procedures of construction, and for safety precautions and programs in connection with the Work. The Contractor shall be responsible to see that the finished Work complies accurately with the Contract Documents. h. The Contractor shall appoint a competent Project Manager with general authority to manage the Project for the Contractor. The Contractor shall also keep on the Project at all times during the Work of the Contractor a competent Resident Superintendent and necessary assistants who shall not be replaced without prior written approval by the Owner. i. If, in the opinion of the Owner, any Subcontractor on the Project is incompetent or otherwise unsatisfactory, such Subcontractor shall be replaced by the Contractor with no increase in the Contract Price if and when directed by the Owner. j. The Contractor shall attend all progress conferences and all other meetings or conferences. The Contractor shall be represented at these progress conferences by a representative having the authority of the Project Manager and by such other representatives as the Owner may direct. k. Costs and expenses of providing samples for and assistance in any testing shall be borne by the Contractor. Any Work in which untested materials are used without approval or written permission of the Owner shall be removed and replaced at Contractor's expense. 5. PAYMENT & TAXES a. The Owner hereby agrees to pay to the Contractor for the faithful performance of this Agreement, and the Contractor hereby agrees to perform all of the Work for a sum not-to- exceed Four Hundred Ninety Two Thousand Ninety Six Dollars ($492,096). Not later than the fifth (5th) day of each calendar month the Contractor shall submit to the Owner's Representative a Request for Payment for work done during the previous calendar month. (i) The Request for Payment shall be in form of a standardized invoice or AIA Document G702-703 appropriately addressed to Owner's Representative at PO Box 8181, Hillsborough NC 27278 and shall show substantially the value of work done during the previous calendar month. (ii) The amount due for payment shall be ninety-five percent (95%) of the value of work completed since the last Request for Payment and this amount shall be paid by the Revised 2/17 3 DocuSign Envelope ID: B5986604-2420-4A6E-BD13-01F64E43BD25 Owner on or before the last business day of the month. Owner shall retain five percent (5%) (the "Retainage"). (1) Upon Owner's Representative's certification that fifty percent (50%) of the Work has been satisfactorily completed Retainage shall be reduced to two and one half percent(2'/2%). (2) Upon Owner's Representative's certification that ninety percent (90%) of the Work has been satisfactorily completed Retainage may be discontinued. Retainage may be discontinued, at Owner's Discretion, so long as work continues to be completed satisfactorily and on schedule. (iii) Final payment shall not be due to the Contractor until thirty (30) days after Final Completion of the Work, including punch list work, has been satisfactorily completed and an appropriate Affidavit, Indemnification, and Release as required in Section 8(d) below has been received by Owner. b. Should Owner reasonably determine that Contractor has failed to perform the Work related to a Request for Payment, Owner, at its discretion may provide the Contractor ten (10) days to cure the breach. Owner may withhold the accompanying payment without penalty until such time as Contractor cures the breach. (i) Should Contractor or its representatives fail to cure the breach within ten (10) days, or fail to reasonably agree to such modified schedule, Owner may immediately terminate this Agreement in writing, without penalty or incurring further obligation to Contractor. (ii) This section shall not be interpreted to limit the definition of breach to the failure to perform the Work related to a Request for Payment. c. The Contractor has included in the Contract Price and shall pay all taxes assessed by any authority on the Work or the labor and materials used therein except that Owner shall, to the extent authorized by North Carolina law, be responsible for the cost of applicable sales tax on the generators purchased and installed pursuant to this Agreement. It shall be the Contractor's responsibility to furnish the Owner documentary evidence showing the materials used and sales and use tax paid by the Contractor and each of its subcontractors. d. Should the Owner receive notice that the Contractor has failed to pay a Subcontractor for the Work performed related to a Request for Payment, Owner shall have the authority to withhold payment of the disputed amount until parties resolve their dispute. Failure to pay the Contractor pursuant to this section of the Agreement shall not be deemed to be a breach of the Agreement. 6. NON—APPROPRIATION a. Contractor acknowledges that Owner is a governmental entity, and the validity of this Agreement is based upon the availability of public funding under the authority of its statutory mandate. Revised 2/17 4 DocuSign Envelope ID: B5986604-2420-4A6E-BD13-01F64E43BD25 b. In the event that public funds are unavailable and not appropriated for the performance of Owner's obligations under this Agreement, then this Agreement shall automatically expire without penalty to Owner immediately upon written notice to Contractor of the unavailability and non-appropriation of public funds. It is expressly agreed that Owner shall not activate this non-appropriation provision for its convenience or to circumvent the requirements of this Agreement,but only as an emergency fiscal measure during a substantial fiscal crisis. c. In the event of a change in the Owner's statutory authority, mandate and/or mandated functions, by state and/or federal legislative or regulatory action, which adversely affects Owner's authority to continue its obligations under this Agreement, then this Agreement shall automatically terminate without penalty to Owner upon written notice to Contractor of such limitation or change in Owner's legal authority. 7. NOTICES Any notice required by this Agreement shall be in writing and delivered by certified or registered mail, return receipt requested to the following: Owner: Contractor: Orange County National Power Corporation Attn: Jeff Thompson Attn: Joel Cheek P.O. Box 8181 4541 Preslyn Drive Hillsborough,NC 27278 Raleigh,NC 27616 8. MISCELLANEOUS a. Duties and Obligations imposed by the Contract Documents shall be in addition to any Duties and Obligations imposed by state, federal or local law,rules,regulations and ordinances. b. No act or failure to act by the Owner or Contractor shall constitute a waiver of any right or duty granted them under the Contract Documents, nor shall any act or failure to act constitute any approval except as specifically agreed in writing. c. The Work shall be tested and inspected as required by the Contract Documents and as required by law. Unless prohibited by law the costs of all such tests and inspections related to state and federal codes such as ADA, Administrative, Electrical, Plumbing, Mechanical and Building Codes shall be borne by the Contractor. The costs for material and structural testing shall be conducted by an independent third party at the expense of the Owner. Delays related to any of the aforementioned tests and inspections shall not be grounds for delaying the completion of the work. If any such tests and inspections reveal deficiencies in the Work such that the Work does not comply with terms or requirements of the Contract Documents and/or the requirements of any code or law the Contractor is solely responsible for the cost of bringing such deficiencies into compliance with the terms of the Contract Documents and/or any code or law. d. Should the Owner reject any portion of the Work for failing to comply with the Contract Documents Contractor shall immediately, at Contractor's expense, correct the Work. Any such rejection may be made before or after substantial completion. If applicable, any additional expense borne by the Owner under this section shall be paid at Contractor's expense. Revised 2/17 5 DocuSign Envelope ID: B5986604-2420-4A6E-BD13-01F64E43BD25 e. The Contractor shall not assign any portion of this Agreement nor subcontract the Work in its entirety without the prior written consent of the Owner. f. All generators provided and installed pursuant to the terms of this Agreement shall be new generator units. No used or refurbished generator units shall be sold to the Owner or installed as part of this Agreement. Any generator unit discovered to be used and/or refurbished shall be replaced with a new generator unit, identical to the corresponding generator unit shown in Contractor's Custom Quote dated April 28, 2017, at Contractor's cost and expense, within thirty (30) days of Owner's request for replacement. The terms of this section 8f shall survive the expiration of this Agreement. 9. CONSEQUENTIAL DAMAGES a. Owner and Contractor mutually waive any claim against each other for consequential damages. Consequential Damages include: (i) Damages incurred by Owner for loss of use, income, financing, or business. (ii) Damages incurred by Contractor for office expenses, including personnel, loss of financing, profit, income, business, damage to reputation, or any other non-direct damages. 10. ENTIRE AGREEMENT All of the documents listed, referenced or described in this Agreement,the written Notice-to-Proceed, together with Modifications made or issued in accordance herewith are the Contract Documents, and the work, labor, materials, and completed construction required by the Contract Documents and all parts thereof is the Work. The Contract Documents constitute the entire agreement between Owner and Contractor. This Agreement may be amended only by written instrument signed by both parties. Modifications may be evidenced by facsimile signatures. If any provision of the Agreement or General Conditions shall be declared invalid or unenforceable,the remainder of the Agreement shall continue in full force and effect. [SIGNATURE PAGE TO FOLLOW] Revised 2/17 6 DocuSign Envelope ID: B5986604-2420-4A6E-BD13-01F64E43BD25 IN WITNESS WHEREOF, the Parties hereto have executed this Agreement as of the day and date first above written in a number of counterparts, each of which shall, without proof or accounting for other counterparts,be deemed an original contract. ORANGE COUNTY: CONTRACTOR: DocuSigned by: DocuSigned by: By jbin,ln,tt, tka"mt-IrSt By: 1(b�t,V'f 044 0637994 SE477... onnie ammersley, County Manager tleftWMtt �9�i�l xin�Ditdafilde Revised 2/17 7 DocuSign Envelope ID: B5986604-2420-4A6E-BD13-01F64E43BD25 4 4111111111111 GENERAC r.. NATIONAL POWER ,,,,,� {���` INDUSTRIAL now POWER w /yme yll r CUSTOM QUOTE Date: April 28, 2017 SITE NAME: Animal Services REV 6 Quote#: 0020098805 ATTN: Alan Dorman Reference: SD350 Diesel Generator We are pleased to offer our quotation for the referenced project via the CCPA Purchasing Program:. BASE CCPA GENERATOR UNIT—SD350 $42,405.00 BASE DIESEL GENERATOR BILL OF MATERIALS: Quantity 1 -Generac Industrial diesel engine-driven generator set with turbocharged/aftercooled 6-cylinder 12.9L engine,consisting of the following features and accessories: • Stationary Emergency-Standby rated • 350 kW Rating,wired for 277/480 VAC three phase,60 Hz • Permanent Magnet Excitation • UL2200 • EPA Certified • H-100 Control Panel o Meets NFPA 99 and 110 requirements o Temp Range-40 to 70 degrees C o Digital Microprocessor: • Two 4-line x 20 displays,full system status • 3 Phase sensing, +/-0.25%digital voltage regulation • RS232, RS485 and Canbus remote ports • Waterproof connections • All engine sensors are 4-20ma for minimal interference • Programmable I/O • Built-in PLC for special applications o Engine function monitoring and control: • Full range standby operation; programmable auto crank, Emergency Stop,Auto-Off-Manual switch • Isochronous Governor, +/-0.25%frequency regulation • Full system status on all AC output and engine function parameters • Service reminders,trending,fault history(alarm log) • I2T function for full generator protection • Selectable low-speed exercise o HTS transfer switch function monitoring and control o 2-wire start controls for any 2-wire transfer switch • Battery Charger, 10 Amp,NFPA 110 compliant,installed • Coolant Heater,2500W,240VAC • 36"693 Gallon Double-Wall UL142 Basetank o Mechanical fuel level indicator gauge o Electronic fuel level sender • Std set of 3 Manuals • Primary MLCB,80%rated thermal-magnetic o 600 Amp • 2-Year Standard Warranty • SD0350KG22125D18HPYY3 Quantity 1 -Freight Included Page 1 of 2 DocuSign Envelope ID: B5986604-2420-4A6E-BD13-D1F64E43BD25 r.. NATIONAL POWER ,,,,,� {���` INDUSTRIAL , now POWER C,FLARILL A It LOUPE RA AVE (f(r�rt��� �wPOiPTi:rfn;3VA,Al LIMNr 1111ddr, /ymeyll LINE ITEM OPTIONS/UPGRADES FROM CCPA BASE UNIT $29,675.00 • Standard Weather Protective Enclosure o Steel Construction o Industrial Grey Baked-On Powder Coat Finish o Critiacal Muffler Mounted Inside Enclosure • Lead Acid Battery,with rack, installed • Fuel Tank Emergency Vent • Open Transition Automatic Transfer Switch o 600 Amp,3 Pole,277/480 VAC three phase,60 Hz,with 2-Wire Start Circuit o Service Entrance Rated o Nema 3R Enclosure • Factory Authorized Start-up Animal Shelter Installation Scope of Work: Install 400kW Diesel Generator set and a 600A automatic transfer switch. Conduit,Wire, Fittings, Miscellaneous Material $19,875.00 Labor $19,289.00 Crane $11,096.00 Engineering Fee $ 2,804.00 TOTAL INSTALLATION BID $53.064.00 Included: • All Exterior conduits will be metal Excluded: • Civil Engineer Drawings Generator Sets Sized by Owner Generator bases(concrete or asphalt)and required rental equipment for installation provided by Owner. Diesel fuel for startup provided by Owner Required permitting provided by Owner FINAL CUSTOM PRICING (FOR SPECIFIC APPLICATION) Quantity 1 - SD350 DIESEL GENERATOR CCPA BASE COST(SD350): $42,405.00 CUSTOMER SPECIFIED UPGRADES & OPTIONS(AS LISTED ABOVE): $ 82,739.00 Sub-total for the above equipment(Not including any applicable tax): $125,144.00 Sincerely, Joel Cheek Joel Cheek National Power Corporation 919-861-6934 joel.cheek @natpow.com Page 2 of 2 DocuSign Envelope ID: B5986604-2420-4A6E-BD13-D1F64E43BD25 GENERAC r.. NATIONAL 11 POWER 45-4 {���` InINDUSTRIAL 45-4 now POWER C,FLARILL A It LOUPE RA AVE �wPOiPTi:rfn;3VA,Al LIMLA, (1 CUSTOM QUOTE Date: April, 28, 2017 SITE NAME: Cedar Grove QUOTE:0020098823 ATTN: Alan Dorman Reference: SD80 Diesel Generator REV 6 We are pleased to offer our quotation for the referenced project via the CCPA Purchasing Program:. BASE CCPA GENERATOR UNIT-SD80 $16,459.00 BASE DIESEL GENERATOR BILL OF MATERIALS: Quantity 1 -Generac Industrial diesel engine-driven generator set with turbocharged/aftercooled 4-cylinder 4.5L engine,consisting of the following features and accessories: • Stationary Emergency-Standby rated • 80 kW Rating,wired for 120/208 VAC three phase,60 Hz • UL2200 • EPA Certified • SCAQMD • H-100 Control Panel o Meets NFPA 99 and 110 requirements o Temp Range-40 to 70 degrees C o Digital Microprocessor: • Two 4-line x 20 displays,full system status • 3 Phase sensing, +/-0.25%digital voltage regulation • RS232, RS485 and Canbus remote ports • Waterproof connections • All engine sensors are 4-20ma for minimal interference • Programmable I/O • Built-in PLC for special applications o Engine function monitoring and control: • Full range standby operation; programmable auto crank, Emergency Stop,Auto-Off-Manual switch • Isochronous Governor, +/-0.25%frequency regulation • Full system status on all AC output and engine function parameters • Service reminders,trending,fault history(alarm log) • I2T function for full generator protection • Selectable low-speed exercise o HTS transfer switch function monitoring and control o 2-wire start controls for any 2-wire transfer switch • Battery Charger, 10 Amp,NFPA 110 compliant,installed • 110 AH,925 CCA Group 31 Batteries,with rack, installed • Coolant Heater,2000W,240VAC • 24 Hour Double-Wall UL142 Basetank o Mechanical fuel level indicator gauge o Electronic fuel level sender • Std set of 3 Manuals • Primary MLCB,80%rated thermal-magnetic o 300 Amp • Two Year Standard Warranty • 5D008000174.5D18HPYY3 Quantity 1 -Freight Included Page 1 of 2 DocuSign Envelope ID: B5986604-2420-4A6E-BD13-D1F64E43BD25 ENERAC 4t r.. NATIONAL di 11 ,�` POWER INDUSTRIAL n110, 1 LINE ITEM OPTIONS/UPGRADES FROM CCPA BASE UNIT $21,679.00 • Standard Weather Protective Enclosure o Steel Construction o Industrial Grey Baked-On Powder Coat Finish o Critiacal Muffler Mounted Inside Enclosure • Lead Acid Battery,with rack, installed • Fuel Tank Emergency Vent • Open Transition Automatic Transfer Switch o 800 Amp,3 Pole, 120/208 VAC three phase,60 Hz,with 2-Wire Start Circuit o Service Entrance Rated o Nema 3R Enclosure • Factory Authorized Start-up Cedar Grove Installation Scope of Work: Install 80kW Diesel Generator set and a 800A automatic transfer switch. Conduit,Wire, Fittings, Miscellaneous Material $6,305.00 Labor $11,929.00 Crane $4,546.00 Engineering Fee $4,091.00 TOTAL INSTALLATION BID $26.871.00 Included: • All Exterior conduits will be PVC • Kitchen panel on generator power Excluded: • Panel C-D-G will not be on generator power • Civil Engineer Drawings Generator Sets Sized by Owner Generator bases(concrete or asphalt)and required rental equipment for installation provided by Owner. Diesel fuel for startup provided by Owner Required permitting provided by Owner FINAL CUSTOM PRICING (FOR SPECIFIC APPLICATION) Quantity 1 - SD80 DIESEL GENERATOR CCPA BASE COST(SD80): $16,459.00 CUSTOMER SPECIFIED UPGRADES & OPTIONS(AS LISTED ABOVE): $48,550.00 Sub-total for the above equipment (Not including any applicable tax): $65,009.00 Sincerely, Joel Cheek Joel Cheek National Power Corporation 919-861-6934 joel.cheek @natpow.com Page 2 of 2 DocuSign Envelope ID: B5986604-2420-4A6E-BD13-01F64E43BD25 4 4111111111111 GENERAC r.. NATIONAL e P E P INDUSTRIAL 45,4 POWER w /ym yll r CUSTOM QUOTE Date: April 28, 2017 SITE NAME: Efland QUOTE: 0020091784 ATTN: Alan Dorman Reference: SD050 Diesel Generator REV 6 We are pleased to offer our quotation for the referenced project via the CCPA Purchasing Program:. BASE CCPA GENERATOR UNIT—SD050 $12,615.00 BASE DIESEL GENERATOR BILL OF MATERIALS: Quantity 1 -Generac Industrial diesel engine-driven generator set with turbocharged 4-cylinder 3.4L engine,consisting of the following features and accessories: • Stationary Emergency-Standby rated • 50 kW Rating,wired for 120/208 VAC three phase,60 Hz • Permanent Magnet Excitation • No Enclosure(open-set) • UL2200 • EPA Certified • SCAQMD • H-100 Control Panel o Meets NFPA 99 and 110 requirements o Temp Range-40 to 70 degrees C o Digital Microprocessor: • Two 4-line x 20 displays,full system status • 3 Phase sensing, +/-0.25%digital voltage regulation • RS232, RS485 and Canbus remote ports • Waterproof connections • All engine sensors are 4-20ma for minimal interference • Programmable I/O • Built-in PLC for special applications o Engine function monitoring and control: • Full range standby operation; programmable auto crank, Emergency Stop,Auto-Off-Manual switch • Isochronous Governor, +/-0.25%frequency regulation • Full system status on all AC output and engine function parameters • Service reminders,trending,fault history(alarm log) • I2T function for full generator protection • Selectable low-speed exercise o HTS transfer switch function monitoring and control o 2-wire start controls for any 2-wire transfer switch • Standard MLCB,80%rated thermal-magnetic o 200 Amp • Battery Charger,2.5 Amp, installed • Coolant Heater, 1500W, 120VAC • 24 Hour Double-Wall UL142 Basetank o Mechanical fuel level indicator gauge o Electronic fuel level sender • 3 Owner's Manuals • Standard 2-Year Limited Warranty • 5D005000163.4D18HPNN3 Quantity 1 -Freight Included Page 1 of 2 DocuSign Envelope ID: B5986604-2420-4A6E-BD13-D1F64E43BD25 GENERAC r.. NATION ,1�A, L POWER ,,,,,� {�� INDUSTRIAL , n1'11111111, POWER 1111 , / e LINE ITEM OPTIONS/UPGRADES FROM CCPA BASE UNIT $11,315.00 • Standard Weather Protective Enclosure o Steel Construction o Industrial Grey Baked-On Powder Coat Finish o Critiacal Muffler Mounted Inside Enclosure • Upgrade Battery Charger, 10 Amp,to Meet NFPA 110 • Lead Acid Battery,with rack, installed • Fuel Tank Emergency Vent • Transfer Switch o 200 Amp,3 Pole, 120/208 VAC three phase,60 Hz,with 2-Wire Start Circuit o Nema 3R Enclosure • Factory Authorized Start-up Efland Installation Scope of Work: Install 50kW Diesel Generator set and a 200A automatic transfer switch. Conduit,Wire, Fittings, Miscellaneous Material $2,784.00 Labor $8,305.00 Crane $ 1,364.00 Engineering Fee $2,728.00 TOTAL INSTALLATION BID $15.181.00 Included: • All Exterior conduits will be PVC Excluded: • Civil Engineer Drawings Generator Sets Sized by Owner Generator bases(concrete or asphalt)and required rental equipment for installation provided by Owner. Diesel fuel for startup provided by Owner Required permitting provided by Owner FINAL CUSTOM PRICING (FOR SPECIFIC APPLICATION) Quantity 1 - SD050 DIESEL GENERATOR CCPA BASE COST(SD050): $12,615.00 CUSTOMER SPECIFIED UPGRADES & OPTIONS(AS LISTED ABOVE): $ 26,496.00 Sub-total for the above equipment (Not including any applicable tax): $39,111.00 Sincerely, Joel Cheek Joel Cheek National Power Corporation 919-861-6934 joel.cheek©natpow.corn Page 2 of 2 DocuSign Envelope ID: B5986604-2420-4A6E-BD13-01F64E43BD25 4 4111111111111 GENERAC r.. NATIONAL POWER ,,,,,� {���` INDUSTRIAL now POWER 11wuw ( /yme yll r CUSTOM QUOTE Date: April 28, 2017 SITE NAME: Hillsborough Commons Quote#: 0020098867 ATTN: Alan Dorman Reference: SD300 Diesel Generator REV 6 We are pleased to offer our quotation for the referenced project via the CCPA Purchasing Program:. BASE CCPA GENERATOR UNIT—SD300 $35,410.00 BASE DIESEL GENERATOR BILL OF MATERIALS: Quantity 1 -Generac Industrial diesel engine-driven generator set with turbocharged/aftercooled 6-cylinder 12.5L engine,consisting of the following features and accessories: • Stationary Emergency-Standby rated • 300 kW Rating,wired for 277/480 VAC three phase,60 Hz • Permanent Magnet Excitation • UL2200 • EPA Certified • H-100 Control Panel o Meets NFPA 99 and 110 requirements o Temp Range-40 to 70 degrees C o Digital Microprocessor: • Two 4-line x 20 displays,full system status • 3 Phase sensing, +/-0.25%digital voltage regulation • RS232, RS485 and Canbus remote ports • Waterproof connections • All engine sensors are 4-20ma for minimal interference • Programmable I/O • Built-in PLC for special applications o Engine function monitoring and control: • Full range standby operation; programmable auto crank, Emergency Stop,Auto-Off-Manual switch • Isochronous Governor, +/-0.25%frequency regulation • Full system status on all AC output and engine function parameters • Service reminders,trending,fault history(alarm log) • I2T function for full generator protection • Selectable low-speed exercise o HTS transfer switch function monitoring and control o 2-wire start controls for any 2-wire transfer switch • Battery Charger, 10 Amp,NFPA 110 compliant,installed • Coolant Heater,2500W,240VAC • 24 Hour Double-Wall UL142 Basetank o Mechanical fuel level indicator gauge o Electronic fuel level sender • Std set of 3 Manuals • Primary MLCB,80%rated thermal-magnetic o 500 Amp • 2-Year Standard Warranty • SD0300KG22125D18HPYY3 Quantity 1 -Freight Included Page 1 of 2 DocuSign Envelope ID: B5986604-2420-4A6E-BD13-D1F64E43BD25 GENERAC r.. NATIONAL 11 POWEP ,,,,,� {���` INDUSTRIAL now POWER 1111 , / e LINE ITEM OPTIONS/UPGRADES FROM CCPA BASE UNIT $29,899.00 • Standard Weather Protective Enclosure o Steel Construction o Industrial Grey Baked-On Powder Coat Finish o Critiacal Muffler Mounted Inside Enclosure • Lead Acid Battery,with rack, installed • Fuel Tank Emergency Vent • Open Transition Automatic Transfer Switch o 600 Amp,3 Pole,277/480 VAC three phase,60 Hz,with 2-Wire Start Circuit o Service Entrance Rated o Nema 3R Enclosure o Five Year Warranty • Factory Authorized Start-up Hillsborough Commons Installation Scope of Work: Install 300kW Diesel Generator set and a 600A automatic transfer switch. Conduit,Wire, Fittings, Miscellaneous Material $11,998.00 Labor $15,616.00 Crane $11,669.00 Engineering Fee $ 2,824.00 TOTAL INSTALLATION BID $42.107.00 Included: • All Exterior conduits will be PVC • Both the 600A and the 400A MDP to be on the generator • Cutting and patching the side-walk at the rear of the building Excluded: • Civil Engineer Drawings Generator Sets Sized by Owner Generator bases(concrete or asphalt)and required rental equipment for installation provided by Owner. Diesel fuel for startup provided by Owner Required permitting provided by Owner FINAL CUSTOM PRICING (FOR SPECIFIC APPLICATION) Quantity 1 - SD300 DIESEL GENERATOR CCPA BASE COST(SD300): $35,410.00 CUSTOMER SPECIFIED UPGRADES & OPTIONS(AS LISTED ABOVE): $ 72,006.00 Sub-total for the above equipment(Not including any applicable tax): $107,416.00 Sincerely, Joel Cheek Joel Cheek National Power Corporation 919-861-6934 joel.cheek©natpow.corn Page 2 of 2 DocuSign Envelope ID: B5986604-2420-4A6E-BD13-01F64E43BD25 4 4111111111111 GENERAC NATIONAL POWER 45-4 {�I�` InINDUSTRIAL 45-4 now POWER 1111 yme yll r CUSTOM QUOTE Date: April 28, 2017 SITE NAME: RENA QUOTE: 0020091784 ATTN: Alan Dorman Reference: SD050 Diesel Generator REV 6 We are pleased to offer our quotation for the referenced project via the CCPA Purchasing Program:. BASE CCPA GENERATOR UNIT—SD050 $12,615.00 BASE DIESEL GENERATOR BILL OF MATERIALS: Quantity 1 -Generac Industrial diesel engine-driven generator set with turbocharged 4-cylinder 3.4L engine,consisting of the following features and accessories: • Stationary Emergency-Standby rated • 50 kW Rating,wired for 120/208 VAC three phase,60 Hz • Permanent Magnet Excitation • No Enclosure(open-set) • UL2200 • EPA Certified • SCAQMD • H-100 Control Panel o Meets NFPA 99 and 110 requirements o Temp Range-40 to 70 degrees C o Digital Microprocessor: • Two 4-line x 20 displays,full system status • 3 Phase sensing, +/-0.25%digital voltage regulation • RS232, RS485 and Canbus remote ports • Waterproof connections • All engine sensors are 4-20ma for minimal interference • Programmable I/O • Built-in PLC for special applications o Engine function monitoring and control: • Full range standby operation; programmable auto crank, Emergency Stop,Auto-Off-Manual switch • Isochronous Governor, +/-0.25%frequency regulation • Full system status on all AC output and engine function parameters • Service reminders,trending,fault history(alarm log) • I2T function for full generator protection • Selectable low-speed exercise o HTS transfer switch function monitoring and control o 2-wire start controls for any 2-wire transfer switch • Standard MLCB,80%rated thermal-magnetic o 200 Amp • Battery Charger,2.5 Amp, installed • Coolant Heater, 1500W, 120VAC • 24 Hour Double-Wall UL142 Basetank o Mechanical fuel level indicator gauge o Electronic fuel level sender • 3 Owner's Manuals • Standard 2-Year Limited Warranty • 5D005000163.4D18HPNN3 Quantity 1 -Freight Included Page 1 of 2 DocuSign Envelope ID: B5986604-2420-4A6E-BD13-D1F64E43BD25 GENERAC r.. NATIONAL POWER ,,,,,� INDUSTRIAL , POWER 1111 , / e • LINE ITEM OPTIONS/UPGRADES FROM CCPA BASE UNIT $11,315.00 • Standard Weather Protective Enclosure o Steel Construction o Industrial Grey Baked-On Powder Coat Finish o Critiacal Muffler Mounted Inside Enclosure • Upgrade Battery Charger, 10 Amp,to Meet NFPA 110 • Lead Acid Battery,with rack, installed • Fuel Tank Emergency Vent • Transfer Switch o 200 Amp,3 Pole, 120/208 VAC three phase,60 Hz,with 2-Wire Start Circuit o Nema 3R Enclosure • Factory Authorized Start-up Rena Installation Scope of Work Install 50kW Diesel Generator set and a 200A automatic transfer switch. Conduit,Wire, Fittings,Miscellaneous Material $ 3,433.00 Labor $10,296.00 Crane $ 1,364.00 Engineering Fee $ 2,728.00 TOTAL INSTALLATION BID $17.821.00 Included: • All Exterior conduits will be PVC • EMT interior of building Excluded: • Civil Engineer Drawings Generator Sets Sized by Owner Generator bases(concrete or asphalt)and required rental equipment for installation provided by Owner. Diesel fuel for startup provided by Owner Required permitting provided by Owner FINAL CUSTOM PRICING (FOR SPECIFIC APPLICATION) Quantity 1 - SD050 DIESEL GENERATOR CCPA BASE COST(SD050): $12,615.00 CUSTOMER SPECIFIED UPGRADES & OPTIONS(AS LISTED ABOVE): $ 29,136.00 Sub-total for the above equipment (Not including any applicable tax): $41,751.00 Sincerely, Joel Cheek Joel Cheek National Power Corporation 919-861-6934 joel.cheek @natpow.com Page 2 of 2 DocuSign Envelope ID: B5986604-2420-4A6E-BD13-01F64E43BD25 4 4111111111111 GENERAC r.. NATIONAL POWER ,,,,,� {���` INDUSTRIAL now POWER 11wuw ( /yme yll r CUSTOM QUOTE Date: April 28, 2017 SITE NAME: Passmore (at Triangle Sportsplex) QUOTE: 0020098825 ATTN: Alan Dorman Reference: SD200 Diesel Generator REV 6 We are pleased to offer our quotation for the referenced project via the CCPA Purchasing Program:. BASE CCPA GENERATOR UNIT—SD200 $30,075.00 BASE DIESEL GENERATOR BILL OF MATERIALS: Quantity 1 -Generac Industrial diesel engine-driven generator set with turbocharged/aftercooled 6-cylinder 8.7L engine,consisting of the following features and accessories: • Stationary Emergency-Standby rated • 200 kW Rating,wired for 277/480 VAC three phase,60 Hz • UL2200 • EPA Certified • SCAQMD • H-100 Control Panel o Meets NFPA 99 and 110 requirements o Temp Range-40 to 70 degrees C o Digital Microprocessor: • Two 4-line x 20 displays,full system status • 3 Phase sensing, +/-0.25%digital voltage regulation • RS232, RS485 and Canbus remote ports • Waterproof connections • All engine sensors are 4-20ma for minimal interference • Programmable I/O • Built-in PLC for special applications o Engine function monitoring and control: • Full range standby operation; programmable auto crank, Emergency Stop,Auto-Off-Manual switch • Isochronous Governor, +/-0.25%frequency regulation • Full system status on all AC output and engine function parameters • Service reminders,trending,fault history(alarm log) • I2T function for full generator protection • Selectable low-speed exercise o HTS transfer switch function monitoring and control o 2-wire start controls for any 2-wire transfer switch • Battery Charger, 10 Amp,NFPA 110 compliant,installed • 110 AH,925 CCA Group 31 Batteries,with rack, installed • Coolant Heater,2000W,240VAC • 24 Hour Double-Wall UL142 Basetank o Mechanical fuel level indicator gauge o Electronic fuel level sender • Std set of 3 Manuals • Primary MLCB,80%rated thermal-magnetic o 350 Amp • Two Year Standard Warranty • SD0200KG178.7D18HPYY3 Quantity 1 -Freight Included Page 1 of 2 DocuSign Envelope ID: B5986604-2420-4A6E-BD13-D1F64E43BD25 pA r.. NATIONAL 11 POWER ,,,,,� {���` INDUSTRIAL (f(r�rt��� now POWER C,FLARILL A It LOUPE RA AVE �wPOiPTi:rfn;3VA,Al LIMNr 1111ddr, /ymeyll LINE ITEM OPTIONS/UPGRADES FROM CCPA BASE UNIT $19,528.00 • Standard Weather Protective Enclosure o Steel Construction o Industrial Grey Baked-On Powder Coat Finish o Critiacal Muffler Mounted Inside Enclosure • Lead Acid Battery,with rack, installed • Fuel Tank Emergency Vent • Open Transition Automatic Transfer Switch o 400 Amp,3 Pole,277/480 VAC three phase,60 Hz,with 2-Wire Start Circuit o Service Entrance Rated o Nema 3R Enclosure • Factory Authorized Start-up Passmore Installation Scope of Work: Install 250kW Diesel Generator set and a 400A automatic transfer switch. Conduit,Wire, Fittings, Miscellaneous Material $29,765.00 Labor $24,524.00 Crane $ 1,591.00 Engineering Fee $ 8,182.00 TOTAL INSTALLATION BID $64.062.00 Included: • All Exterior conduits will be PVC, EMT interior of building Excluded: • Civil Engineer Drawings Generator Sets Sized by Owner Generator bases(concrete or asphalt)and required rental equipment for installation provided by Owner. Diesel fuel for startup provided by Owner Required permitting provided by Owner FINAL CUSTOM PRICING (FOR SPECIFIC APPLICATION) Quantity 1 - SD200 DIESEL GENERATOR CCPA BASE COST(SD200): $30,075.00 CUSTOMER SPECIFIED UPGRADES & OPTIONS(AS LISTED ABOVE): $ 83,590.00 Sub-total for the above equipment(Not including any applicable tax): $113,665.00 Sincerely, Joel Cheek Joel Cheek National Power Corporation 919-861-6934 joel.cheek©natpow.corn Page 2 of 2 DocuSign Envelope ID: B5986604-2420-4A6E-BD13-D1F64E43BD25 OP ID:AH ,a T RE CERTIFICATE OF LIABILITY INSURANCE DATE(MM/DD/YYYY) 06/13/2017 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER NAME:CONTACT Amy G. Hartley SNIPES INSURANCE SERVICE, INC PHONE g10-892-2121 FAX 910-892-5228 PO BOX 1165 (NC,No,Ext): (NC,No): DUNN, NC 28335 E-MAIL ADDRESS:amy @snipesins.com DAL SNIPES PRODUCER NATIO-3 CUSTOMER ID#: INSURER(S)AFFORDING COVERAGE NAIC# INSURED NATIONAL POWER CORPORATION INSURER A:CINCINNATI INSURANCE COMPANY 10677 4541 PRESLYN DRIVE INSURER B:CINCINNATI CASUALTY 28665 RALEIGH, NC 27616 INSURER C: INSURER D: INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUBR POLICY EFF POLICY EXP LIMITS LTR INSR WVD POLICY NUMBER (MM/DD/YYYY) (MM/DD/YYYY) GENERAL LIABILITY EACH OCCURRENCE $ 1,000,000 A X COMMERCIAL GENERAL LIABILITY X EPP 0392642 07/01/2016 07/01/2017 DAMAGE TO RENTED 100 000 PREMISES(Ea occurrence) $ CLAIMS-MADE X OCCUR MED EXP(Any one person) $ 5,000 X PER PROJ AGGRE PERSONAL&ADV INJURY $ 1,000,000 X XCU INCLUDED GENERAL AGGREGATE $ 2,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: PRODUCTS-COMP/OP AGG $ 2,000,000 POLICY X PRO LOC $ JECT AUTOMOBILE LIABILITY X COMBINED SINGLE LIMIT $ 1,000,000 (Ea accident) A X ANY AUTO EBA 0392642 07/01/2016 07/01/2017 BODILY INJURY(Per person) $ ALL OWNED AUTOS BODILY INJURY(Per accident) $ SCHEDULED AUTOS PROPERTY DAMAGE X HIRED AUTOS (PER ACCIDENT) $ X NON-OWNED AUTOS $ X UMBRELLA LIAB X OCCUR EACH OCCURRENCE $ 5,000,000 EXCESS LIAB CLAIMS-MADE AGGREGATE $ 5,000,000 A EPP 0392642 07/01/2016 07/01/2017 DEDUCTIBLE *FOLLOW F $ X RETENTION $ 0 $ WORKERS COMPENSATION WC STATU- OTH- AND EMPLOYERS'LIABILITY Y/N TORY LIMITS ER ANY PROPRIETOR/PARTNER/EXECUTIVE E.L.EACH ACCIDENT $ OFFICER/MEMBER EXCLUDED? N/A (Mandatory in NH) E.L.DISEASE-EA EMPLOYEE $ If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ A ERROR&OMISSIONS EPP 0392642 07/01/2016 07/01/2017 OCC/AGGR 1 mm/1 mm A Crime EPP 0392642 07/01/2016 07/01/2017 Empl Dis 500,000 DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES(Attach ACORD 101,Additional Remarks Schedule,if more space is required) ORANGE COUNTY IS AN ADDITIONAL INSURED FOR BOTH GENERAL LIABILITY AND AUTO LIABILITY AS REQUIRED BY WRITTEN CONTRACT PER CARRIER FORMS GA233 0207 AND AA4171 1105 CERTIFICATE HOLDER CANCELLATION ORANG-1 SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE ORANGE COUNTY THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. PO BOX 8181 HILLSBOROUGH, NC 27278 AUTHORIZED REPRESENTATIVE 7161, 441161"rie ©1988-2009 ACORD CORPORATION. All rights reserved. ACORD 25(2009/09) The ACORD name and logo are registered marks of ACORD DocuSign Envelope ID: B5986604-2420-4A6E-BD13-D1F64E43BD25 ' CERTIFICATE OF LIABILITY INSURANCE I DATE(MMIDD/YYYY) 06/13/17 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Aon Risk Services,Inc of Florida NAME: Aon Risk Services,Inc of Florida 1001 Brickell Bay Drive,Suite#1100 PHONE FAX Miami,FL 33131 4937 (NC,No,Ext):800-743-8130 (A/C,No):800-522-7514 EMAIL ADDRESS: ADP.COI.Center @Aon.com INSURER(S)AFFORDING COVERAGE NAIC# INSURER A: New Hampshire Ins Co 23841 INSURED INSURER B: ADP TotalSource FL XVI,Inc. 10200 Sunset Drive INSURER C: Miami,FL 33173 L/C/F INSURER D: National Power Corporation INSURER E: 4541 Preslyn Dr Raleigh,NC 27616 INSURER F: COVERAGES CERTIFICATE NUMBER: 1747662 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. LIMITS SHOWN ARE AS REQUESTED. INSR TYPE OF INSURANCE ADDL SUER POLICY NUMBER POLICY EFF POLICY EXP LIMITS LTR INSR WVD (MM/DD/YYYY) (MM/DD/YYYY) COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ DAMAGE TO RENTED CLAIMS-MADE OCCUR PREMISES(Ea occurrence) $ MED EXP(Any one person) $ PERSONAL&ADV INJURY $ GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ POLICY I I PROJECT n LOC PRODUCTS-COMP/OP AGG $ OTHER $ AUTOMOBILE LIABILITY (Ea accident)INGLE LIMIT $ ANY AUTO BODILY INJURY(Per person) $ OWNED SCHEDULED _AUTOS ONLY _AUTOS BODILY INJURY(Per accident) $ HIRED NON-OWNED PROPERTY DAMAGE AUTOS ONLY AUTOS ONLY (Per accident) $ $ UMBRELLA LIAB — EACH OCCURRENCE $ EXCESS LIAB CLAIMS-MADE AGGREGATE $ DEC I I RETENTION$ WORKERS COMPENSATION X PER OTH- A AND EMPLOYERS'LIABILITY Y/N WC 061145787 NC 07/01/16 07/01/17 STATUTE ER ANY PROPRIETOR/PARTNER/EXECUTIVE OFFICER/MEMBER EXCLUDED? N/A X E.L.EACH ACCIDENT $ 2,000,000 (Mandatory in NH) E.L.DISEASE-EA EMPLOYEE $ 2,000,000 If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ 2,000,000 DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached if more space is required) All worksite employees working for NATIONAL POWER CORPORATION,paid under ADP TOTALSOURCE,INC's payroll,are covered under the above stated policy. WAIVER OF SUBROGATION IN FAVOR OF CERTIFICATE HOLDER AS RESPECTS OF JOB PERFORMED BY NATIONAL POWER CORPORATION AS REQUIRED BY WRITTEN CONTRACT. CERTIFICATE HOLDER CANCELLATION Orange County SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE PO Box 8181 THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Hillsborough,NC 27278 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE ©1988-2015 ACORD CORPORATION.All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD DocuSign Envelope ID: B5986604-2420-4A6E-BD13-D1F64E43BD25 ' CERTIFICATE OF LIABILITY INSURANCE I DATE(MMIDD/YYYY) 06/13/17 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Aon Risk Services,Inc of Florida NAME: Aon Risk Services,Inc of Florida 1001 Brickell Bay Drive,Suite#1100 PHONE FAX Miami,FL 33131 4937 (NC,No,Ext):800-743-8130 (A/C,No):800-522-7514 EMAIL ADDRESS: ADP.COI.Center @Aon.com INSURER(S)AFFORDING COVERAGE NAIC# INSURER A: New Hampshire Ins Co 23841 INSURED INSURER B: ADP TotalSource FL XVI,Inc. 10200 Sunset Drive INSURER C: Miami,FL 33173 L/C/F INSURER D: National Power Corporation INSURER E: 4541 Preslyn Dr Raleigh,NC 27616 INSURER F: COVERAGES CERTIFICATE NUMBER: 1747663 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. LIMITS SHOWN ARE AS REQUESTED. INSR TYPE OF INSURANCE ADDL SUER POLICY NUMBER POLICY EFF POLICY EXP LIMITS LTR INSR WVD (MM/DD/YYYY) (MM/DD/YYYY) COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ DAMAGE TO RENTED CLAIMS-MADE OCCUR PREMISES(Ea occurrence) $ MED EXP(Any one person) $ PERSONAL&ADV INJURY $ GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ POLICY I I PROJECT n LOC PRODUCTS-COMP/OP AGG $ OTHER $ AUTOMOBILE LIABILITY (Ea accident)INGLE LIMIT $ ANY AUTO BODILY INJURY(Per person) $ OWNED SCHEDULED _AUTOS ONLY _AUTOS BODILY INJURY(Per accident) $ HIRED NON-OWNED PROPERTY DAMAGE AUTOS ONLY AUTOS ONLY (Per accident) $ $ UMBRELLA LIAB — EACH OCCURRENCE $ EXCESS LIAB CLAIMS-MADE AGGREGATE $ DEC I I RETENTION$ WORKERS COMPENSATION X PER OTH- A AND EMPLOYERS'LIABILITY Y/N WC 026167977 NC 07/01/17 07/01/18 STATUTE ER ANY PROPRIETOR/PARTNER/EXECUTIVE OFFICER/MEMBER EXCLUDED? N/A X E.L.EACH ACCIDENT $ 2,000,000 (Mandatory in NH) E.L.DISEASE-EA EMPLOYEE $ 2,000,000 If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ 2,000,000 DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached if more space is required) All worksite employees working for NATIONAL POWER CORPORATION,paid under ADP TOTALSOURCE,INC's payroll,are covered under the above stated policy. WAIVER OF SUBROGATION IN FAVOR OF CERTIFICATE HOLDER AS RESPECTS OF JOB PERFORMED BY NATIONAL POWER CORPORATION AS REQUIRED BY WRITTEN CONTRACT. CERTIFICATE HOLDER CANCELLATION Orange County SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE PO Box 8181 THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Hillsborough,NC 27278 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE ©1988-2015 ACORD CORPORATION.All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD